Line 11: Line 11:
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
| Municipality: Mayfield Township
+
| Municipality: [[Gates Mills Village,_Cuyahoga_County,_Ohio|Gates Mills Village]]
 
|-
 
|-
 
| Operator Name: [[OHIO VALLEY ENERGY SYSTEM CORP]]
 
| Operator Name: [[OHIO VALLEY ENERGY SYSTEM CORP]]
Line 33: Line 33:
 
| Configuration: Directional
 
| Configuration: Directional
 
|-
 
|-
| Latitude: 41.519625178
+
| Latitude: <Latitude>
 
|-
 
|-
 
| Longitude: -81.40612043
 
| Longitude: -81.40612043

Revision as of 10:09, 14 August 2019

Well Details

Well ID: 34-035-21888
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Gates Mills Village
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name: GMV TOWN HALL
License Status: Producing
License Date: 2006-03-02
Spud Date: 2006-06-05
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-06-12
Well Total Depth: 3408 ft
Configuration: Directional
Latitude: <Latitude>
Longitude: -81.40612043

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-03-02 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/2/2006, Expired Date:3/2/2007 6:00:00 AM, Drilling unit acres:23, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2006-03-17 ADDED TARGET INFORMATION TO PERMIT. TARGET INFORMATION: 550'NL & 390'WL OF LOT 1, TRACT 3; X= 2,299,945; Y= 676,935; ELEV.= 720'.
Original Spud 2006-06-05 RBDMS Rec
Completed 2006-06-12 RBDMS Rec
Reached Total Depth 2006-06-12 RBDMS Rec
Correction to Well 2006-08-18 CORRECTION TO TARGET INFORMATION: FOOTAGE = 515'NL & 420'WL OF LOT 1, TRACT 3; X= NO CHANGE; Y= 676,970. (AS DRILLED PLAT FOR A DIRECTIONAL DRILL)
Completion Report Received 2006-08-21 RBDMS Rec
Construction Permit Expires 2007-03-02 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-11-21 3187 3266 77

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2214 Bbl 60000 500 GALLONS MUD ACID & 500 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEM CORP 0 34 55
2007 OHIO VALLEY ENERGY SYSTEM CORP 17148 163 357
2008 OHIO VALLEY ENERGY SYSTEM CORP 42294 87 365
2009 OHIO VALLEY ENERGY SYSTEM CORP 14753 45 365
2010 OHIO VALLEY ENERGY SYSTEM CORP 27124 120 365
2011 OHIO VALLEY ENERGY SYSTEM CORP 53884 124 365
2012 OHIO VALLEY ENERGY SYSTEM CORP 32570 40 366
2013 OHIO VALLEY ENERGY SYSTEM CORP 28727 44 365
2014 OHIO VALLEY ENERGY SYSTEM CORP 22502 47 365
2015 OHIO VALLEY ENERGY SYSTEM CORP 17050 47 365
2016 OHIO VALLEY ENERGY SYSTEM CORP 14387 7 365
2017 OHIO VALLEY ENERGY SYSTEM CORP 12024 38 365
2018 OHIO VALLEY ENERGY SYSTEM CORP 10252 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 OHIO VALLEY ENERGY SYSTEM CORP Brine 2170 55
2007 OHIO VALLEY ENERGY SYSTEM CORP Brine 74 357
2008 OHIO VALLEY ENERGY SYSTEM CORP Brine 128 365
2009 OHIO VALLEY ENERGY SYSTEM CORP Brine 82 365
2010 OHIO VALLEY ENERGY SYSTEM CORP Brine 191 365
2011 OHIO VALLEY ENERGY SYSTEM CORP Brine 246 365
2012 OHIO VALLEY ENERGY SYSTEM CORP Brine 110 366
2013 OHIO VALLEY ENERGY SYSTEM CORP Brine 178 365
2014 OHIO VALLEY ENERGY SYSTEM CORP Brine 152 365
2015 OHIO VALLEY ENERGY SYSTEM CORP Brine 82 365
2016 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEM CORP Brine 72 365
2018 OHIO VALLEY ENERGY SYSTEM CORP Brine 35 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0034792305 2006-11-16 Preliminary Restoration No Violations
0075970821 2018-06-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection. At the time of this inspection, the fittings and connections at the wellhead and battery were secure with the following exception: the lubricator at the wellhead was leaking a small amount of grease, and required routine maintenance. Tank lids were closed and secure. Load-lines were locked and secure. The chart record was active. Production reports were current. Enclosure gates were locked. I walked the areas surrounding the well and battery and found normal conditions of the extant greenscape. I notified Ohio Valley Energy about the need for maintenance at the wellhead.
0163499838 2006-02-16 Drill / Deepen / Reopen No Violations site inspection.
0219834330 2006-06-05 Drill / Deepen / Reopen No Violations Rig move on digging pits
0408622816 2006-06-09 Drill / Deepen / Reopen No Violations drilling 2067
0415306731 2008-10-22 Production Wells No Violations clean-up
0522283025 2008-10-23 Production Wells No Violations follow -upSpill was in tank battery area Tanks removed and gravel removed and replaced then tanks were reset fence replaced case closed.
0528249192 2015-08-25 UrbanProduction Wells No Violations On site with ODNR staff Terry Whitehair, Scott King and Steve Irwin. Tank battery fence was in good repair. Man door was locked. Equipment inside of the tank battery was clean and no indication of leaks. Poly tank and low profile production tank are anchored to cement barriers inside of the battery. Well ran a cycle during inspection. Well was fenced and the man door was locked. Plunger lift assembly was in good repair.
0611060254 2006-06-08 Drill / Deepen / Reopen No Violations drilling 1500 met rick s on site to go over site condition.
1049045239 2006-06-06 Drill / Deepen / Reopen No Violations Surface job Gates Mills.
1150726917 2006-06-07 Drill / Deepen / Reopen No Violations topped off outside casing with cement.
1224620861 2008-10-21 Production Wells No Violations Well is a rabbit well. Low profile 100BBL and a poly tank in battery. Mechanical separator. On site at the request of inspector Norburt. Two inch plug at the bottom of the brine production tank was removed, possible vandalism. Approximately 10 BBLs of brine was spilled and 3 BBLs of oil. Battery man door was locked at the time of inspection. Pictures taken, oil and brine release cut a ditch in the side of the dike and the floor of the battery. Dike did not breach. Over spray on the outside of the dike will need cleaned. Brine and oil leak sprayed the tank battery fence. Operator is currently on there way to start clean up. Man door on the well head was locked. Permit number needs added to the ID sign. Operator is planning on removing tanks and removing soil from the battery Wednesday.
1236214367 2014-08-13 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 06/12/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead and surrounding area are free of signs of leaks or other impacts. The wellhead and battery are located adjacent to the Gates Mill Fire Station, town hall, and maintenance garage. Access to the wellhead and battery are via the asphalt-paved entry to the maintenance garage area from River Road. The battery is comprised of 1 steel 50-barrel low-boy production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-out is bull-plugged. The secondary containment at the battery appears well maintained. Process safety equipment is present. I did not observe any signs or evidence of leakage, spills, or problems. The ID placards at the wellhead and battery are in good condition.
1307024598 2011-02-28 Production Wells No Violations
1339777167 2006-06-06 Drill / Deepen / Reopen No Violations surface and site check needs orange fencing on south side .
1600995613 2017-05-23 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and tank battery is separate board-on-board enclosures located adjacent to the city hall and maintenance buildings. The battery elements are comprised of one 100-barrel steel production tank and one plastic brine tank, and separator unit with associated connections and production appurtenances. The load-lines were plugged, locked and secure. The tank lids were closed and sealed. There was secondary containment which was intact with dry interior and free from signs of spills or leakage. Spark arrestor, low-pressure relief valve, and carbon filter were present and well maintained. ID signage was present and complete. Areas around the wellhead were comprise of turf grass lawn. The battery is located at the edge of the driveway and parking area for the maintenance garage. I walked the areas surrounding the wellhead and battery and found no signs of impact or problems.
1736260548 2011-04-04 Production Wells No Violations Well location and tank battery are in good repair.
1845949600 2010-11-02 Production Wells No Violations No violation.
1856250289 2008-11-04 Production Wells No Violations violation corrected
1982843380 2013-10-22 UrbanProduction Wells No Violations The producing unit consists of a mechanical plunger lift unit and above-ground storage tank (AST) battery. The battery is comprised of 1 50-barrel steel production tanks, 1 50-barrel poly brine tank, Dominion metering run, and separator unit. The battery and wellhead are enclosed in separate board-on-board fences. The load-outs are bull-plugged. The ID and secondary containment are good. The unit is fitted with carbon canister, low-pressure relief valve, and spark arrestor. Gates are locked. Lease road is in good condition. No problems noted.

For data sources see[9]