Well ID: 34-155-23381 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.302453915,"lon":-80.80023259,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Bazetta Township | |
Operator Name: DUSTIN ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: PROKOP | |
License Status: Producing | |
License Date: 1990-11-28 | |
Spud Date: 1991-01-25 | |
Spud Drilling Contractor: MOHAWK DRLG | |
Final Drill Date: 1991-02-01 | |
Well Total Depth: 4556 ft | |
Configuration: Vertical | |
Latitude: 41.302453915 | |
Longitude: -80.80023259 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1990-11-10 | |
CO | 1990-11-28 | 2135 DUSTIN ENERGY INC GeoDate 11/28/90 |
Oil and Gas | 1990-11-28 | Issued Date 11/28/90 Expired Date 11/28/91 Acres 0061406 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04556 Proposed Drill Depth 04556 |
Completed | 1991-02-01 | |
Reached Total Depth | 1991-02-01 | |
Completion Report Received | 1991-09-26 | |
Construction Permit Expires | 1991-11-28 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4313 | 4460 | 0 |
2006-09-11 | 4353 | 4406 | 42 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 64000 | 30000 | FARC W/64M GAL WATER AND 300 SX | ||
ACID | 0 | 500 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | DUSTIN ENERGY INC | 0 | 0 | 365 |
1992 | DUSTIN ENERGY INC | 29373 | 262 | 304 |
1993 | DUSTIN ENERGY INC | 24902 | 105 | 365 |
1994 | DUSTIN ENERGY INC | 12555 | 37 | 120 |
1995 | DUSTIN ENERGY INC | 12429 | 30 | 120 |
1996 | DUSTIN ENERGY INC | 14841 | 134 | 180 |
1997 | DUSTIN ENERGY INC | 15475 | 38 | 270 |
1998 | DUSTIN ENERGY INC | 11687 | 42 | 245 |
1999 | DUSTIN ENERGY INC | 14145 | 0 | 365 |
2000 | DUSTIN ENERGY INC | 5922 | 0 | 194 |
2001 | DUSTIN ENERGY INC | 8815 | 53 | 365 |
2002 | DUSTIN ENERGY INC | 5200 | 0 | 365 |
2003 | DUSTIN ENERGY INC | 494 | 0 | 365 |
2004 | DUSTIN ENERGY INC | 10681 | 0 | 365 |
2005 | DUSTIN ENERGY INC | 8136 | 46 | 365 |
2006 | DUSTIN ENERGY INC | 8736 | 0 | 365 |
2007 | DUSTIN ENERGY INC | 8296 | 0 | 365 |
2008 | DUSTIN ENERGY INC | 17021 | 14 | 365 |
2009 | DUSTIN ENERGY INC | 15909 | 0 | 365 |
2010 | DUSTIN ENERGY INC | 14469 | 0 | 365 |
2011 | DUSTIN ENERGY INC | 16830 | 0 | 365 |
2012 | DUSTIN ENERGY INC | 15065 | 0 | 366 |
2013 | DUSTIN ENERGY INC | 12378 | 0 | 365 |
2014 | DUSTIN ENERGY INC | 11443 | 0 | 365 |
2015 | DUSTIN ENERGY INC | 12715 | 0 | 365 |
2016 | DUSTIN ENERGY INC | 14227 | 0 | 365 |
2017 | DUSTIN ENERGY INC | 11458 | 0 | 365 |
2018 | DUSTIN ENERGY INC | 12980 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | DUSTIN ENERGY INC | Brine | 1140 | 365 |
1992 | DUSTIN ENERGY INC | Brine | 211 | 304 |
1993 | DUSTIN ENERGY INC | Brine | 30 | 365 |
1994 | DUSTIN ENERGY INC | Brine | 6 | 120 |
1995 | DUSTIN ENERGY INC | Brine | 22 | 120 |
1996 | DUSTIN ENERGY INC | Brine | 13 | 180 |
1997 | DUSTIN ENERGY INC | Brine | 11 | 270 |
1998 | DUSTIN ENERGY INC | Brine | 16 | 245 |
1999 | DUSTIN ENERGY INC | Brine | 2 | 365 |
2000 | DUSTIN ENERGY INC | Brine | 18 | 194 |
2001 | DUSTIN ENERGY INC | Brine | 12 | 365 |
2002 | DUSTIN ENERGY INC | Brine | 7 | 365 |
2003 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2004 | DUSTIN ENERGY INC | Brine | 20 | 365 |
2005 | DUSTIN ENERGY INC | Brine | 48 | 365 |
2006 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2007 | DUSTIN ENERGY INC | Brine | 40 | 365 |
2008 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2009 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2010 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2011 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2012 | DUSTIN ENERGY INC | Brine | 0 | 366 |
2013 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2014 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2015 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2016 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2017 | DUSTIN ENERGY INC | Brine | 0 | 365 |
2018 | DUSTIN ENERGY INC | Brine | 52 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0102977810 | 2002-10-23 | Preliminary Restoration | No Violations | Meets requirements. |
0682139156 | 2004-02-20 | Preliminary Restoration | No Violations | Restoration approved . |
1395241295 | 2014-03-19 | UrbanProduction Wells | No Violations | My inspection found the well in production. The well was equipped with a plunger lift unit. A domestic gas line came off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 30 barrel brine tank, and a separator. The dike was slightly weathered; however, it meets containment requirements. An identification sign was staked into the berm of the dike. The information on the identification sign was highly faded. There was a bull plug on the load line. The lease road was in stable condition. The well was placed into production prior to House Bill 278. I called Dustin Energy and instructed the owner to fix the identification sign. Bill stated the information would be corrected immediately. |
For data sources see[9]