Line 11: | Line 11: | ||
| County: [[Mahoning_County,_Ohio|Mahoning]] | | County: [[Mahoning_County,_Ohio|Mahoning]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Ellsworth Township,_Mahoning_County,_Ohio|Ellsworth Township]] |
|- | |- | ||
| Operator Name: [[ENERGY RESOURCES OF AMERICA IN]] | | Operator Name: [[ENERGY RESOURCES OF AMERICA IN]] |
Well ID: 34-099-20532 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.990329419,"lon":-80.82547102,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Ellsworth Township | |
Operator Name: ENERGY RESOURCES OF AMERICA IN | |
Well Pad ID: | |
Farm/Lease Name: HENDRICKS PAUL M | |
License Status: Producing | |
License Date: 1975-06-23 | |
Spud Date: 1975-09-01 | |
Spud Drilling Contractor: | |
Final Drill Date: 1976-04-05 | |
Well Total Depth: 5404 ft | |
Configuration: Vertical | |
Latitude: 40.990329419 | |
Longitude: -80.82547102 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1975-06-23 | 773 FORTUNE GAS & OIL GeoDate 6/23/75 |
Original Spud | 1975-09-01 | |
Completed | 1976-04-05 | |
Reached Total Depth | 1976-04-05 | |
CO | 1994-10-06 | 4939 ENERGY RESOURCES AMERICA GeoDate 6/23/75 |
Record Last Modified | 2019-06-04 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5240 | 5358 | 42 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 79000 Gal | 74000 | |||
ACID | 0 | 300 Gal | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1497458076 | 2017-06-12 | Production Wells | Violations Noted | The purpose of my inspection was to conduct a status check on well #2-0532. RBDMS indicated the owner was current with reporting production. Lease access was over a graveled road that was in good repair. The well location was overgrown with vegetation. No identification was present at the well head. The 4.5 production casing was equipped with a plunger lift assembly. No audible or visual leaks were observed. Production valves were in the open position. The tank battery consisted of one (1) horizontal separator, one (1) 100 bbl production tank and one (1) 50 bbl brine tank. The separator was in good repair. No audible or visual leaks were detected. A current 7 day production chart was in the meter house. An earthen dike that was stable and free of fluid was constructed around tanks. Mature vegetation was growing on and within the dike. Correct and legible identification was present on the tank body. The load line valve was closed and was not plugged. The drain line valve was closed and not plugged. The valve had leaked production fluid onto the ground. The fluid did not appear fresh, live or mobile at the time of inspection. The hatch lid was closed. Energy Resources of America shall post correct and legible identification at the well head. Tank valves within the battery shall be secured with bull plugs. Vegetation at the well head and tank battery shall be maintained consistent with reasonably prudent operations. Compliance activities shall be completed within thirty (30) days of receipt of this notice. |
1597246758 | 2017-12-13 | Production Wells | No Violations | The purpose of my inspection was to follow-up on compliance notice # 1497458076. At the time of inspection correct and legible identification was posted at the tank battery. Bull plugs were installed in the tank valves. No further action was necessary. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1497458076 | US-OH-114036 | 2017-12-26 | 9-9-02 | General Safety |
1497458076 | US-OH-114037 | 2017-12-26 | 9-9-05(A)10 | Failure to legibly identify well |
1497458076 | US-OH-114038 | 2017-12-26 | 9-9-05(D) | Failure to have required locks, bull plugs |