| State: Ohio | | State: Ohio | ||
|- | |- | ||
− | | County: | + | | County: <County> |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Canaan Township,_Wayne_County,_Ohio|Canaan Township]] |
|- | |- | ||
| Operator Name: [[KENOIL LLC]] | | Operator Name: [[KENOIL LLC]] |
Well ID: 34-169-22040 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.951112981,"lon":-81.93524633,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: Canaan Township | |
Operator Name: KENOIL LLC | |
Well Pad ID: | |
Farm/Lease Name: FOLLOWAY JAMES E | |
License Status: Producing | |
License Date: 1981-02-24 | |
Spud Date: 1981-05-02 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-06-04 | |
Well Total Depth: 3320 ft | |
Configuration: Vertical | |
Latitude: 40.951112981 | |
Longitude: -81.93524633 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-02-24 | 627 KENOIL GeoDate 2/24/81 |
Original Spud | 1981-05-02 | R.I. R.L. CHG IN WELL # 2-26-81 |
Completed | 1981-06-04 | R.I. R.L. CHG IN WELL # 2-26-81 |
Reached Total Depth | 1981-06-04 | R.I. R.L. CHG IN WELL # 2-26-81 |
Record Last Modified | 2019-06-04 | R.I. R.L. CHG IN WELL # 2-26-81 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3176 | 3192 | 14 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 105000 Gal | 42000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | KENOIL LLC | 7515 | 2494 | 0 |
1985 | KENOIL LLC | 6732 | 1685 | 0 |
1986 | KENOIL LLC | 4564 | 925 | 365 |
1987 | KENOIL LLC | 1625 | 376 | 365 |
1988 | KENOIL LLC | 3632 | 1177 | 365 |
1989 | KENOIL LLC | 3765 | 1094 | 365 |
1990 | KENOIL LLC | 2735 | 756 | 365 |
1991 | KENOIL LLC | 3082 | 348 | 365 |
1992 | KENOIL LLC | 3234 | 394 | 365 |
1993 | KENOIL LLC | 3033 | 312 | 365 |
1994 | KENOIL LLC | 2109 | 271 | 0 |
1995 | KENOIL LLC | 3533 | 74 | 0 |
1996 | KENOIL LLC | 2954 | 241 | 0 |
1997 | KENOIL LLC | 1655 | 176 | 365 |
1998 | KENOIL LLC | 1890 | 108 | 365 |
1999 | KENOIL LLC | 1466 | 137 | 0 |
2000 | KENOIL LLC | 1180 | 67 | 365 |
2001 | KENOIL LLC | 1093 | 67 | 365 |
2002 | KENOIL LLC | 910 | 96 | 365 |
2003 | KENOIL LLC | 1107 | 34 | 365 |
2004 | KENOIL LLC | 962 | 39 | 365 |
2005 | KENOIL LLC | 854 | 107 | 365 |
2006 | KENOIL LLC | 859 | 177 | 365 |
2007 | KENOIL LLC | 958 | 272 | 365 |
2008 | KENOIL LLC | 929 | 424 | 365 |
2009 | KENOIL LLC | 480 | 226 | 365 |
2010 | KENOIL LLC | 590 | 171 | 365 |
2011 | KENOIL LLC | 735 | 157 | 0 |
2012 | KENOIL LLC | 576 | 188 | 366 |
2013 | KENOIL LLC | 574 | 150 | 365 |
2014 | KENOIL LLC | 484 | 208 | 365 |
2015 | KENOIL LLC | 414 | 151 | 365 |
2016 | KENOIL LLC | 512 | 249 | 365 |
2017 | KENOIL LLC | 459 | 240 | 365 |
2018 | KENOIL LLC | 426 | 166 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | KENOIL LLC | Brine | 0 | 0 |
1985 | KENOIL LLC | Brine | 70 | 0 |
1986 | KENOIL LLC | Brine | 0 | 365 |
1987 | KENOIL LLC | Brine | 0 | 365 |
1988 | KENOIL LLC | Brine | 0 | 365 |
1989 | KENOIL LLC | Brine | 0 | 365 |
1990 | KENOIL LLC | Brine | 145 | 365 |
1991 | KENOIL LLC | Brine | 160 | 365 |
1992 | KENOIL LLC | Brine | 33 | 365 |
1993 | KENOIL LLC | Brine | 13 | 365 |
1994 | KENOIL LLC | Brine | 15 | 0 |
1995 | KENOIL LLC | Brine | 0 | 0 |
1996 | KENOIL LLC | Brine | 0 | 0 |
1997 | KENOIL LLC | Brine | 6 | 365 |
1998 | KENOIL LLC | Brine | 15 | 365 |
1999 | KENOIL LLC | Brine | 0 | |
2000 | KENOIL LLC | Brine | 365 | |
2001 | KENOIL LLC | Brine | 0 | 365 |
2002 | KENOIL LLC | Brine | 0 | 365 |
2003 | KENOIL LLC | Brine | 0 | 365 |
2004 | KENOIL LLC | Brine | 10 | 365 |
2005 | KENOIL LLC | Brine | 0 | 365 |
2006 | KENOIL LLC | Brine | 0 | 365 |
2007 | KENOIL LLC | Brine | 47 | 365 |
2008 | KENOIL LLC | Brine | 37 | 365 |
2009 | KENOIL LLC | Brine | 0 | 365 |
2010 | KENOIL LLC | Brine | 0 | 365 |
2011 | KENOIL LLC | Brine | 0 | |
2012 | KENOIL LLC | Brine | 0 | 366 |
2013 | KENOIL LLC | Brine | 10 | 365 |
2014 | KENOIL LLC | Brine | 5 | 365 |
2015 | KENOIL LLC | Brine | 0 | 365 |
2016 | KENOIL LLC | Brine | 1 | 365 |
2017 | KENOIL LLC | Brine | 10 | 365 |
2018 | KENOIL LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0010113790 | 2018-08-28 | Production Wells | No Violations | Inspected production well on 08/28/2018. The tank battery consists of 2-100 bbl steel tanks, 1-1,600 gal plastic tank, 1-vertical separator, 1-drip, 1-meter box, and 1-meter with a drip and regulator, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, and a drip. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0461679838 | 2017-11-03 | Production Wells | No Violations | Inspected production well on 11/03/2017. The tank battery consists of 2-100 bbl steel tanks, 1-1,600 gal plastic tank, 1-vertical separator, 2-drips, 1-meter, and 1-meter box, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor, and a drip. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0489728290 | 2012-11-21 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
0537577578 | 2016-10-26 | Production Wells | No Violations | Inspected production well on 10/26/2016. The tank battery consists of 2-100 bbl steel tanks, 1-1,600 gal plastic tank, and 1-vertical separator, located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0946122385 | 2014-11-25 | Production Wells | No Violations | This is a pumping unit well. No apparent problems at time of inspection. |
1161785470 | 2013-11-14 | Production Wells | No Violations | This pumping unit well has no apparent problems at time of inspection. |
1858143958 | 2015-11-02 | Production Wells | No Violations | Inspected production well on 11/02/2015. The tank battery consists of 2-100 bbl steel tanks, 1-1,600 gal plastic tank, and 1-vertical separator located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
For data sources see[9]