Well Details

Well ID: 34-127-25783
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Harrison Township
Operator Name: MIDWEST OIL & GAS
Well Pad ID:
Farm/Lease Name: PITCOCK-STATE OF OHIO
License Status: Producing
License Date: 1982-11-23
Spud Date: 1982-11-29
Spud Drilling Contractor: RON MORAN DRLG
Final Drill Date: 1983-01-04
Well Total Depth: 3566 ft
Configuration: Vertical
Latitude: 39.783130100
Longitude: -82.09187663

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-11-23 Issued Date 11/23/82 Expired Date 5/22/83 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03566 Proposed Drill Depth 03566
Original Spud 1982-11-29
Completed 1983-01-04
Reached Total Depth 1983-01-04
CO 1983-01-15 573 MIDWEST OIL & GAS GeoDate 11/23/82
Completion Report Received 1983-01-20
Construction Permit Expires 1983-05-22
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3475 3566 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 MIDWEST OIL & GAS 0 1312 365
1986 MIDWEST OIL & GAS 0 683 365
1987 MIDWEST OIL & GAS 0 471 365
1988 MIDWEST OIL & GAS 0 473 365
1989 MIDWEST OIL & GAS 0 341 365
2010 MIDWEST OIL & GAS 0 70 365
2011 MIDWEST OIL & GAS 0 72 365
2012 MIDWEST OIL & GAS 0 80 366

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 MIDWEST OIL & GAS Brine 0 365
1986 MIDWEST OIL & GAS Brine 0 365
1987 MIDWEST OIL & GAS Brine 0 365
1988 MIDWEST OIL & GAS Brine 35 365
1989 MIDWEST OIL & GAS Brine 0 365
2010 MIDWEST OIL & GAS Brine 150 365
2011 MIDWEST OIL & GAS Brine 85 365
2012 MIDWEST OIL & GAS Brine 80 366

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL7024 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0027401592 2013-12-31 Production Wells No Violations This well is capable of production. The well has a pumping unit on it with rods and 2 tubing in it. The production valve is open at the wellhead. The identification for this well is located at the tank pad. No violations at this time.
0119896892 2016-02-03 Production Wells No Violations I went out to this well to do a field inspection on it to see if it was leaking due to the evacuation of Crooksville in Perry County. This well is capable of production with all the production lines hooked up. The well is being used for Domestic use. There is no gas leaking at or around the well. There are no violations to report at this time.
0992069479 2018-10-15 Production Wells Violations Noted I was on location today to do a field inspection on this well. During the time of my inspection I was unable to locate any identification for this well. The well is required to have the identification posted either at the well or at the production tank. If there is more than one well producing into the same production tank the identification is required to be at both the well and the production tank. The identification must have the following on it. The owner, lease name, well number, permit number, county and emergency contact number.
1377338819 2017-12-14 Production Wells No Violations This well appears to be capable of production. The well has a pumping unit on it with rods and 2 inch diameter tubing in it. The production valve is open at the wellhead. The identification for this well is located at the tank pad. There are no violations at this time.
1868339823 2016-03-07 Production Wells No Violations I returned to this well to see if there were any leaks at the well. During my inspection I found all of the production lines are hooked up to the well. The well is being used for domestic gas. I did not find any gas leaks at this well during my inspection.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0992069479 US-OH-131389 2018-10-19 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References