X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-169-25458"

m
m
Line 9: Line 9:
 
| State: Ohio
 
| State: Ohio
 
|-
 
|-
| County: [[Wayne_County,_Ohio|Wayne]]
+
| County: <County>
 
|-
 
|-
| Municipality: [[Milton_Township,_Wayne_County,_Ohio|Milton Township]]
+
| Municipality: [[Milton Township,_Wayne_County,_Ohio|Milton Township]]
 
|-
 
|-
 
| Operator Name: [[MS PRODUCING LLC]]
 
| Operator Name: [[MS PRODUCING LLC]]

Revision as of 21:30, 14 August 2019

Well Details

Well ID: 34-169-25458
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality: Milton Township
Operator Name: MS PRODUCING LLC
Well Pad ID:
Farm/Lease Name: BOWMAN KENNETH L MARVIN # 3
License Status: Producing
License Date: 2002-09-25
Spud Date: 2002-10-12
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2002-10-19
Well Total Depth: 5610 ft
Configuration: Vertical
Latitude: 40.986610247
Longitude: -81.84708597

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-09-25 Proposed Formations:KNOX, Issued Date:9/25/2002, Expired Date:9/25/2003 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2002-10-09 Proposed Formations:KNOX, Issued Date:10/9/2002, Expired Date:10/9/2003 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW
Original Spud 2002-10-11 RBDMS Rec
Correction to Well 2002-10-18 CORRECTION TO X, Y COORDINATES: X= 2,180,255 AND Y= 481,552.
Reached Total Depth 2002-10-19 RBDMS Rec
Completion Report Received 2003-02-13 RBDMS Rec
Construction Permit Expires 2003-09-25 RBDMS Rec
Change of Owner 2013-01-07 Operator changed from 265, CSAPO LIMITED to 8423, C & C PRODUCING LLC
Change of Owner 2018-01-10 Operator changed from 8423, C & C PRODUCING LLC to 9842, MS PRODUCING LLC
Record Last Modified 2018-01-10 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-03-20 5562 5566 5

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 CSAPO LIMITED 53388 1128 365
2004 CSAPO LIMITED 11618 570 365
2005 CSAPO LIMITED 3956 320 365
2006 CSAPO LIMITED 2899 263 365
2007 CSAPO LIMITED 1575 435 365
2008 CSAPO LIMITED 2151 279 365
2009 CSAPO LIMITED 1252 120 365
2010 CSAPO LIMITED 694 173 365
2011 CSAPO LIMITED 568 168 365
2012 CSAPO LIMITED 456 281 366
2013 C & C PRODUCING LLC 449 178 365
2014 C & C PRODUCING LLC 360 201 365
2015 C & C PRODUCING LLC 347 90 365
2016 C & C PRODUCING LLC 359 191 365
2017 C & C PRODUCING LLC 304 159 365
2018 MS PRODUCING LLC 332 88 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 CSAPO LIMITED Brine 360 365
2004 CSAPO LIMITED Brine 5 365
2005 CSAPO LIMITED Brine 200 365
2006 CSAPO LIMITED Brine 138 365
2007 CSAPO LIMITED Brine 31 365
2008 CSAPO LIMITED Brine 55 365
2009 CSAPO LIMITED Brine 18 365
2010 CSAPO LIMITED Brine 40 365
2011 CSAPO LIMITED Brine 28 365
2012 CSAPO LIMITED Brine 26 366
2013 C & C PRODUCING LLC Brine 62 365
2014 C & C PRODUCING LLC Brine 38 365
2015 C & C PRODUCING LLC Brine 42 365
2016 C & C PRODUCING LLC Brine 106 365
2017 C & C PRODUCING LLC Brine 121 365
2018 MS PRODUCING LLC Brine 62 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
001220i305 2002-10-23 Production Wells No Violations Solidifing drilling pits in flood plain area. Service rig setting up over well. Rain 40 degrees.
0027778774 2002-10-09 Drill / Deepen / Reopen No Violations Called by Frank Csapo to inspect drilling pits in floodplain. Approved pit demensions of 6 depth and taper walls. Line pits with reenforced plastic liners. Pits are to be pumped, solidified and closed immediately after drilling the well. Location is being revised but Lat and Long readings are for new location. Sunny, dry 55 degrees. No tank battery demensions at this time.
0029578786 2002-10-21 Production Wells No Violations Flood plain location pumping drilling pits at this time. 60 degrees, sunny. Need pits solidified when fluid is removed.
0166225462 2015-05-21 Production Wells No Violations This pump jack well has no apparent problems or violations at this time.
0191872725 2018-03-19 Production Wells No Violations Inspected production well on 03/19/2018. The tank battery consists of 1-210 bbl steel tank, located within an earthen dike; 1-vertical separator and 1-meter box with a drip are located within a separate earthen dike nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0239653299 2014-05-14 Production Wells No Violations This pumping unit well appears to have no problems at time of inspection.
0389961739 2017-06-05 Production Wells No Violations Inspected production well on 06/05/2017. The tank battery consists of 1-210 bbl steel tank and 1-vertical separator, each located within separate earthen dikes. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
0617569264 2017-06-05 Preliminary Restoration No Violations Inspected production well on 06/05/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes.
0641312757 2015-11-02 Production Wells No Violations Inspected production well on 11/02/2015. The tank battery consists of 1-210 bbl steel tank located within an earthen dike; 1-vertical separator is located nearby. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1245442573 2016-08-10 Production Wells No Violations Inspected production well on 08/10/2016. The tank battery consists of 1-210 bbl steel tank and 1-vertical separator, each located within a separate earthen dike. The well is equipped with a pump jack with an electric motor. Well identification is clearly displayed at both the tank battery and the wellhead. No problems were noted at the time of the inspection.
1446151399 2013-05-24 Production Wells No Violations This pumping unit well appears to have no problems at this time.

For data sources see[9]

References