If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Geauga_County,_Ohio|Geauga]] | | County: [[Geauga_County,_Ohio|Geauga]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Bainbridge Township,_Geauga_County,_Ohio|Bainbridge Township]] |
|- | |- | ||
| Operator Name: [[SUMMIT PETROLEUM INC]] | | Operator Name: [[SUMMIT PETROLEUM INC]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: <Latitude> |
|- | |- | ||
| Longitude: -81.36635930 | | Longitude: -81.36635930 |
Well ID: 34-055-20469 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.34918983,"lon":-81.3663593,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Bainbridge Township | |
Operator Name: SUMMIT PETROLEUM INC | |
Well Pad ID: | |
Farm/Lease Name: SEAWORLD ETAL | |
License Status: Producing | |
License Date: 1983-10-24 | |
Spud Date: 1983-10-29 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 1983-11-04 | |
Well Total Depth: 3940 ft | |
Configuration: Vertical | |
Latitude: <Latitude> | |
Longitude: -81.36635930 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1983-03-14 | Issued Date 3/14/83 Expired Date 9/10/83 Acres 0516490 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1983-10-24 | 277 ATWOOD ENERGY INC GeoDate 10/24/83 |
Oil and Gas | 1983-10-24 | Issued Date 10/24/83 Expired Date 4/21/84 Acres 0516490 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03940 Proposed Drill Depth 03940 |
Original Spud | 1983-10-29 | R.I. 10-29-83 |
Completed | 1983-11-04 | R.I. 10-29-83 |
Reached Total Depth | 1983-11-04 | R.I. 10-29-83 |
CO | 1983-11-25 | 277 ATWOOD ENERGY INC GeoDate 3/14/83 |
Completion Report Received | 1983-11-25 | R.I. 10-29-83 |
Construction Permit Expires | 1984-04-21 | R.I. 10-29-83 |
CO | 1995-07-18 | 4205 TRANSFUEL RESOURCES CO GeoDate 10/24/83 |
CO | 1995-10-27 | 213 LOMAK OPERATING CO GeoDate 10/24/83 |
Change of Owner | 2000-06-27 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2001-08-29 | Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 2026, SUMMIT PETROLEUM INC |
Last Compliance Report | 2013-09-12 | R.I. 10-29-83 |
Record Last Modified | 2017-08-18 | R.I. 10-29-83 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3728 | 3840 | 0 |
2006-09-11 | 3770 | 3832 | 14 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 86000 Gal | 60000 | FRAC;86MG H2O,60M# SD,190MCF N2 | ||
N2 | 0 | 190 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ATWOOD ENERGY INC | 60114 | 938 | 0 |
1985 | ATWOOD ENERGY INC | 16781 | 281 | 0 |
1986 | ATWOOD ENERGY INC | 11358 | 266 | 365 |
1987 | ATWOOD ENERGY INC | 9804 | 173 | 365 |
1988 | ATWOOD ENERGY INC | 8151 | 86 | 365 |
1989 | ATWOOD ENERGY INC | 7045 | 186 | 365 |
1990 | ATWOOD ENERGY INC | 11955 | 169 | 365 |
1991 | ATWOOD ENERGY INC | 9493 | 175 | 365 |
1992 | ATWOOD RESOURCES INC | 8195 | 158 | 365 |
1993 | ATWOOD RESOURCES INC | 7281 | 92 | 365 |
1995 | TRANSFUEL RESOURCES CO | 3608 | 0 | 270 |
1996 | RANGE OPERATING COMPANY | 3619 | 82 | 365 |
1997 | RANGE OPERATING COMPANY | 4888 | 46 | 365 |
1998 | RANGE OPERATING COMPANY | 4997 | 80 | 365 |
1999 | RANGE RESOURCES-APPALACHIA LLC | 782 | 0 | 92 |
2000 | RANGE RESOURCES-APPALACHIA LLC | 2267 | 37 | 365 |
2001 | SUMMIT PETROLEUM INC | 633 | 42 | 365 |
2002 | SUMMIT PETROLEUM INC | 9272 | 87 | 365 |
2003 | SUMMIT PETROLEUM INC | 2817 | 24 | 365 |
2004 | SUMMIT PETROLEUM INC | 2940 | 63 | 365 |
2005 | SUMMIT PETROLEUM INC | 2901 | 116 | 365 |
2006 | SUMMIT PETROLEUM INC | 2701 | 31 | 365 |
2007 | SUMMIT PETROLEUM INC | 2673 | 103 | 365 |
2008 | SUMMIT PETROLEUM INC | 3077 | 38 | 365 |
2009 | SUMMIT PETROLEUM INC | 3090 | 91 | 365 |
2010 | SUMMIT PETROLEUM INC | 2481 | 37 | 365 |
2011 | SUMMIT PETROLEUM INC | 3039 | 75 | 365 |
2012 | SUMMIT PETROLEUM INC | 2367 | 67 | 366 |
2013 | SUMMIT PETROLEUM INC | 2438 | 78 | 365 |
2014 | SUMMIT PETROLEUM INC | 2463 | 37 | 365 |
2015 | SUMMIT PETROLEUM INC | 2226 | 52 | 365 |
2016 | SUMMIT PETROLEUM INC | 2204 | 70 | 365 |
2017 | SUMMIT PETROLEUM INC | 2054 | 71 | 365 |
2018 | SUMMIT PETROLEUM INC | 1560 | 49 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ATWOOD ENERGY INC | Brine | 0 | 0 |
1985 | ATWOOD ENERGY INC | Brine | 200 | 0 |
1986 | ATWOOD ENERGY INC | Brine | 210 | 365 |
1987 | ATWOOD ENERGY INC | Brine | 70 | 365 |
1988 | ATWOOD ENERGY INC | Brine | 70 | 365 |
1989 | ATWOOD ENERGY INC | Brine | 230 | 365 |
1990 | ATWOOD ENERGY INC | Brine | 340 | 365 |
1991 | ATWOOD ENERGY INC | Brine | 100 | 365 |
1992 | ATWOOD RESOURCES INC | Brine | 75 | 365 |
1993 | ATWOOD RESOURCES INC | Brine | 50 | 365 |
1995 | TRANSFUEL RESOURCES CO | Brine | 0 | 270 |
1996 | RANGE OPERATING COMPANY | Brine | 0 | 365 |
1997 | RANGE OPERATING COMPANY | Brine | 205 | 365 |
1998 | RANGE OPERATING COMPANY | Brine | 365 | |
1999 | RANGE OPERATING COMPANY | Brine | 64 | 273 |
2000 | RANGE RESOURCES-APPALACHIA LLC | Brine | 50 | 365 |
2001 | SUMMIT PETROLEUM INC | Brine | 0 | 365 |
2002 | SUMMIT PETROLEUM INC | Brine | 76 | 365 |
2003 | SUMMIT PETROLEUM INC | Brine | 8 | 365 |
2004 | SUMMIT PETROLEUM INC | Brine | 0 | 365 |
2005 | SUMMIT PETROLEUM INC | Brine | 75 | 365 |
2006 | SUMMIT PETROLEUM INC | Brine | 64 | 365 |
2007 | SUMMIT PETROLEUM INC | Brine | 71 | 365 |
2008 | SUMMIT PETROLEUM INC | Brine | 96 | 365 |
2009 | SUMMIT PETROLEUM INC | Brine | 105 | 365 |
2010 | SUMMIT PETROLEUM INC | Brine | 90 | 365 |
2011 | SUMMIT PETROLEUM INC | Brine | 78 | 365 |
2012 | SUMMIT PETROLEUM INC | Brine | 106 | 366 |
2013 | SUMMIT PETROLEUM INC | Brine | 142 | 365 |
2014 | SUMMIT PETROLEUM INC | Brine | 43 | 365 |
2015 | SUMMIT PETROLEUM INC | Brine | 72 | 365 |
2016 | SUMMIT PETROLEUM INC | Brine | 68 | 365 |
2017 | SUMMIT PETROLEUM INC | Brine | 57 | 365 |
2018 | SUMMIT PETROLEUM INC | Brine | 81 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0500851796 | 2013-05-23 | UrbanProduction Wells | No Violations | My inspection found the well to be equipped with a concoil wellhead. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBLpoly brine tank, and a mechanical separator. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition. |
0785601278 | 2005-11-15 | Annular Disposal | No Violations | no AD |
0885749378 | 2017-02-17 | UrbanProduction Wells | No Violations | During this inspection, it was observed that the well was equipped with a Concoil plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well was submitted in 2015. The tank battery consisted of 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations observed. |
1034691846 | 2011-11-09 | Annular Disposal | No Violations | Well is in good repair. No annular disposal noted. |
1212199398 | 2017-06-07 | Annular Disposal | No Violations | At the time of this inspection, the well was equipped with a Concoil plunger lift assembly and no annualar disposal was present. |
1262880116 | 2010-01-07 | Production Wells | No Violations | Well head is in good repair. Fence is up, identification sign is up. Guard rail is around the well head. Man door to the well is locked. Tank battery has a 100BBL tank and a poly tank in it. Man door was not locked to the tank battery. Lock was in place. Locked after inspection. Mechanical separator tank spacing is not with the limits of ORC 1509. Tank is too close to the separator. |
1532441176 | 2018-07-24 | UrbanProduction Wells | No Violations | During this inspection, it was observed that the well was equipped with a Concoil plunger lift assembly. The gate valve on the tubing and the valve on the 2 inch flow line off of the tubing was open. The well was fenced and locked. Reported production for this well was current. The tank battery consisted of 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery. Lease access was stable. No violations observed. |
1590585417 | 2015-01-15 | UrbanProduction Wells | No Violations | My inspection found the chain link fence around the wellhead needs to be repaired. No other changes to the location since my last inspection. I contacted Alan, a supervisor with Summit Petroleum about the repairs. |
For data sources see[9]