X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-055-20469"

m
m
Line 11: Line 11:
 
| County: [[Geauga_County,_Ohio|Geauga]]
 
| County: [[Geauga_County,_Ohio|Geauga]]
 
|-
 
|-
| Municipality: [[Bainbridge_Township,_Geauga_County,_Ohio|Bainbridge Township]]
+
| Municipality: [[Bainbridge Township,_Geauga_County,_Ohio|Bainbridge Township]]
 
|-
 
|-
 
| Operator Name: [[SUMMIT PETROLEUM INC]]
 
| Operator Name: [[SUMMIT PETROLEUM INC]]
Line 33: Line 33:
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: 41.349189830
+
| Latitude: <Latitude>
 
|-
 
|-
 
| Longitude: -81.36635930
 
| Longitude: -81.36635930

Revision as of 23:21, 14 August 2019

Well Details

Well ID: 34-055-20469
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Bainbridge Township
Operator Name: SUMMIT PETROLEUM INC
Well Pad ID:
Farm/Lease Name: SEAWORLD ETAL
License Status: Producing
License Date: 1983-10-24
Spud Date: 1983-10-29
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1983-11-04
Well Total Depth: 3940 ft
Configuration: Vertical
Latitude: <Latitude>
Longitude: -81.36635930

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-03-14 Issued Date 3/14/83 Expired Date 9/10/83 Acres 0516490 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1983-10-24 277 ATWOOD ENERGY INC GeoDate 10/24/83
Oil and Gas 1983-10-24 Issued Date 10/24/83 Expired Date 4/21/84 Acres 0516490 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03940 Proposed Drill Depth 03940
Original Spud 1983-10-29 R.I. 10-29-83
Completed 1983-11-04 R.I. 10-29-83
Reached Total Depth 1983-11-04 R.I. 10-29-83
CO 1983-11-25 277 ATWOOD ENERGY INC GeoDate 3/14/83
Completion Report Received 1983-11-25 R.I. 10-29-83
Construction Permit Expires 1984-04-21 R.I. 10-29-83
CO 1995-07-18 4205 TRANSFUEL RESOURCES CO GeoDate 10/24/83
CO 1995-10-27 213 LOMAK OPERATING CO GeoDate 10/24/83
Change of Owner 2000-06-27 Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2001-08-29 Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 2026, SUMMIT PETROLEUM INC
Last Compliance Report 2013-09-12 R.I. 10-29-83
Record Last Modified 2017-08-18 R.I. 10-29-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3728 3840 0
2006-09-11 3770 3832 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 86000 Gal 60000 FRAC;86MG H2O,60M# SD,190MCF N2
N2 0 190 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 ATWOOD ENERGY INC 60114 938 0
1985 ATWOOD ENERGY INC 16781 281 0
1986 ATWOOD ENERGY INC 11358 266 365
1987 ATWOOD ENERGY INC 9804 173 365
1988 ATWOOD ENERGY INC 8151 86 365
1989 ATWOOD ENERGY INC 7045 186 365
1990 ATWOOD ENERGY INC 11955 169 365
1991 ATWOOD ENERGY INC 9493 175 365
1992 ATWOOD RESOURCES INC 8195 158 365
1993 ATWOOD RESOURCES INC 7281 92 365
1995 TRANSFUEL RESOURCES CO 3608 0 270
1996 RANGE OPERATING COMPANY 3619 82 365
1997 RANGE OPERATING COMPANY 4888 46 365
1998 RANGE OPERATING COMPANY 4997 80 365
1999 RANGE RESOURCES-APPALACHIA LLC 782 0 92
2000 RANGE RESOURCES-APPALACHIA LLC 2267 37 365
2001 SUMMIT PETROLEUM INC 633 42 365
2002 SUMMIT PETROLEUM INC 9272 87 365
2003 SUMMIT PETROLEUM INC 2817 24 365
2004 SUMMIT PETROLEUM INC 2940 63 365
2005 SUMMIT PETROLEUM INC 2901 116 365
2006 SUMMIT PETROLEUM INC 2701 31 365
2007 SUMMIT PETROLEUM INC 2673 103 365
2008 SUMMIT PETROLEUM INC 3077 38 365
2009 SUMMIT PETROLEUM INC 3090 91 365
2010 SUMMIT PETROLEUM INC 2481 37 365
2011 SUMMIT PETROLEUM INC 3039 75 365
2012 SUMMIT PETROLEUM INC 2367 67 366
2013 SUMMIT PETROLEUM INC 2438 78 365
2014 SUMMIT PETROLEUM INC 2463 37 365
2015 SUMMIT PETROLEUM INC 2226 52 365
2016 SUMMIT PETROLEUM INC 2204 70 365
2017 SUMMIT PETROLEUM INC 2054 71 365
2018 SUMMIT PETROLEUM INC 1560 49 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 ATWOOD ENERGY INC Brine 0 0
1985 ATWOOD ENERGY INC Brine 200 0
1986 ATWOOD ENERGY INC Brine 210 365
1987 ATWOOD ENERGY INC Brine 70 365
1988 ATWOOD ENERGY INC Brine 70 365
1989 ATWOOD ENERGY INC Brine 230 365
1990 ATWOOD ENERGY INC Brine 340 365
1991 ATWOOD ENERGY INC Brine 100 365
1992 ATWOOD RESOURCES INC Brine 75 365
1993 ATWOOD RESOURCES INC Brine 50 365
1995 TRANSFUEL RESOURCES CO Brine 0 270
1996 RANGE OPERATING COMPANY Brine 0 365
1997 RANGE OPERATING COMPANY Brine 205 365
1998 RANGE OPERATING COMPANY Brine 365
1999 RANGE OPERATING COMPANY Brine 64 273
2000 RANGE RESOURCES-APPALACHIA LLC Brine 50 365
2001 SUMMIT PETROLEUM INC Brine 0 365
2002 SUMMIT PETROLEUM INC Brine 76 365
2003 SUMMIT PETROLEUM INC Brine 8 365
2004 SUMMIT PETROLEUM INC Brine 0 365
2005 SUMMIT PETROLEUM INC Brine 75 365
2006 SUMMIT PETROLEUM INC Brine 64 365
2007 SUMMIT PETROLEUM INC Brine 71 365
2008 SUMMIT PETROLEUM INC Brine 96 365
2009 SUMMIT PETROLEUM INC Brine 105 365
2010 SUMMIT PETROLEUM INC Brine 90 365
2011 SUMMIT PETROLEUM INC Brine 78 365
2012 SUMMIT PETROLEUM INC Brine 106 366
2013 SUMMIT PETROLEUM INC Brine 142 365
2014 SUMMIT PETROLEUM INC Brine 43 365
2015 SUMMIT PETROLEUM INC Brine 72 365
2016 SUMMIT PETROLEUM INC Brine 68 365
2017 SUMMIT PETROLEUM INC Brine 57 365
2018 SUMMIT PETROLEUM INC Brine 81 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0500851796 2013-05-23 UrbanProduction Wells No Violations My inspection found the well to be equipped with a concoil wellhead. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of a 100 BBL production tank, a 50 BBLpoly brine tank, and a mechanical separator. The proper identification is located on the tank battery and the wellhead. The lease road is in stable condition.
0785601278 2005-11-15 Annular Disposal No Violations no AD
0885749378 2017-02-17 UrbanProduction Wells No Violations During this inspection, it was observed that the well was equipped with a Concoil plunger lift assembly and the valves on the wellhead were open. The well was fenced and locked. The last reported production for this well was submitted in 2015. The tank battery consisted of 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The tank valves were equipped with flat plugs. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the tank battery. Lease access was stable. No violations observed.
1034691846 2011-11-09 Annular Disposal No Violations Well is in good repair. No annular disposal noted.
1212199398 2017-06-07 Annular Disposal No Violations At the time of this inspection, the well was equipped with a Concoil plunger lift assembly and no annualar disposal was present.
1262880116 2010-01-07 Production Wells No Violations Well head is in good repair. Fence is up, identification sign is up. Guard rail is around the well head. Man door to the well is locked. Tank battery has a 100BBL tank and a poly tank in it. Man door was not locked to the tank battery. Lock was in place. Locked after inspection. Mechanical separator tank spacing is not with the limits of ORC 1509. Tank is too close to the separator.
1532441176 2018-07-24 UrbanProduction Wells No Violations During this inspection, it was observed that the well was equipped with a Concoil plunger lift assembly. The gate valve on the tubing and the valve on the 2 inch flow line off of the tubing was open. The well was fenced and locked. Reported production for this well was current. The tank battery consisted of 100 BBL production tank, one 50 BBL poly brine tank and a mechanical separator. The valves on the separator were open and the chart showed production. The tank battery was diked and fenced with a locked man door. The proper, legible signage was located at the well and tank battery. Lease access was stable. No violations observed.
1590585417 2015-01-15 UrbanProduction Wells No Violations My inspection found the chain link fence around the wellhead needs to be repaired. No other changes to the location since my last inspection. I contacted Alan, a supervisor with Summit Petroleum about the repairs.

For data sources see[9]

References