Revision as of 08:14, 15 August 2019

Well Details

Well ID: 34-129-20220
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Wayne Township
Operator Name: LAYLINE OIL AND GAS LLC
Well Pad ID:
Farm/Lease Name: J STEVENSON
License Status: Producing
License Date: 2019-05-28
Spud Date: 2008-01-03
Spud Drilling Contractor: BOWMAN DRILLING
Final Drill Date: 2008-01-10
Well Total Depth: 2494 ft
Configuration: Vertical
Latitude: 39.570669019
Longitude: -82.99996273

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-28 Proposed Formations:TRENTON/ROSE RUN, Issued Date:12/28/2007, Expired Date:12/27/2008 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-10
Completion Report Received 2008-04-18
Change of Owner 2013-10-07 Operator changed from 6091, OHIO ENERGY ASSETS, INC. to 9177, DART OIL & GAS OHIO LLC
Change of Owner 2018-05-22 Operator changed from 9177, DART OIL & GAS OHIO LLC to 10136, LAYLINE OIL AND GAS LLC
APP 2019-05-28 Proposed Formations:ROSE RUN, Issued Date:5/28/2019, Expired Date:5/27/2021 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2019-06-04
Construction Permit Expires 2021-05-27

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 NOT PERFED OR TREATED

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 OHIO ENERGY ASSETS, INC. 0 0 69
2009 OHIO ENERGY ASSETS, INC. 0 31 20
2010 OHIO ENERGY ASSETS, INC. 0 166 132
2011 OHIO ENERGY ASSETS, INC. 0 50 0
2012 OHIO ENERGY ASSETS, INC. 0 44 70
2013 OHIO ENERGY ASSETS, INC. 0 63 122
2014 DART OIL & GAS OHIO LLC 0 62 177
2015 DART OIL & GAS OHIO LLC 0 0 0
2016 DART OIL & GAS OHIO LLC 0 0 0
2017 DART OIL & GAS OHIO LLC 0 56 1
2018 LAYLINE OIL AND GAS LLC 0 0 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 OHIO ENERGY ASSETS, INC. Brine 2055 69
2009 OHIO ENERGY ASSETS, INC. Brine 175 20
2010 OHIO ENERGY ASSETS, INC. Brine 2316 132
2011 OHIO ENERGY ASSETS, INC. Brine 3429
2012 OHIO ENERGY ASSETS, INC. Brine 1427 70
2013 OHIO ENERGY ASSETS, INC. Brine 1342 122
2014 DART OIL & GAS OHIO LLC Brine 1873 177
2015 DART OIL & GAS OHIO LLC Brine 0 0
2016 DART OIL & GAS OHIO LLC Brine 0 0
2017 DART OIL & GAS OHIO LLC Brine 0 1
2018 LAYLINE OIL AND GAS LLC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0048984912 2019-04-29 Production Wells No Violations My inspection revealed this well has been issued a plugging permit. I spoke with the owner of this well who stated the well should be plugged by 6.1.19.
0068811907 2008-01-05 Drill / Deepen / Reopen No Violations - Was contacted by operator on Friday 1/4/ 2008 that they plan to set surface casing about 8:00 PM on 1/04/2008. No phone call received by 8:00 AM Saturday 1/05 went to location. Drill crew hadnt reached depth, driller was using fluid to drill with and conductor had dropped down hole. Crew will set oversize conductor and continue to drill.
0092598085 2018-12-26 Production Wells No Violations My inspection revealed this well consisted of a wellhead with tubing. The valves on the casing and the tubing were in the closed position. The well is connected to a tank battery. The well does not have a pumping unit and is not capable of production.

The well is currently incapable of production. The well owner, LAYLINE OIL AND GAS LLC shall submit a written plugging schedule to Kip Thompson at 5880 Memory Road, Zanesville Ohio 43701 within 30 days, per OAC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.

0097019722 2018-01-30 Production Wells No Violations I received a request to determine if this well met the requirements for 1509.062, Temporary inactive status. The well meets conditions set forth under 1509.062(B) 1-7 and 1509.062(A) 1-2. The well consists of a wellhead with tubing rods and 2-210 barrel tanks. The valves are shut off on the casing and also the tubing. The valve on the production line near the wellhead is shut off. I informed Beth Oswald with Dart Oil&Gas of the need to empty the tanks and production lines when and if the well is approved for temporary inactive status.
0215278568 2018-04-24 Production Wells No Violations My inspection revealed the well consists of a 4.5 inch diameter wellhead with tubing and rods. There is no pumping unit associated with this well. Legible identification was posted.
0243086432 2010-08-10 Production Wells No Violations - pump jack operating while on site. ID on tank.
0310533835 2013-07-03 Production Wells No Violations - The operator is doing repairs to the pu8mp unit, pump unit back into service while on site.
0326997702 2009-03-31 Production Wells No Violations - Pump unit not operating while on site. ID on tank.
0453424219 2017-03-03 Production Wells No Violations Production well inspection. The well consists of a pumping unit and tank battery. The tanks are surrounded by a dike and consists of 4-210 barrel tanks. No violations were noted.
1199894986 2008-01-06 Drill / Deepen / Reopen No Violations - On site for surface cementing of 7 inch casing. Hole was drilled to depth of 786. New 7 inch casing used in well, joint were 42.15 in length. Total casing in well with landing joint 768. Formation Cementing Inc. cementing contactor.

- 190 feet of 9 5/8 conductor casing set in well, 9 5/8 casing dropped about 40 feet down hole operator place 11 3/4 conductor casing from surface to over top of 9 5/8 casing.

1200488577 2008-01-10 Drill / Deepen / Reopen No Violations - On site for drilling progress, at current time well depth is 2240 feet. Operator plans to reach TD today. Weather light rain temp 40s time 3:30PM.
1200492726 2008-01-16 Drill / Deepen / Reopen No Violations Drilling completed rig off site, area rough graded and one pit still open.

- GPS well N 39.57074 W 083.00005 Acc. 9

1204040344 2008-02-21 Drill / Deepen / Reopen No Violations - Service rig on location, working on well to put into production. Met with Joe Melville owner of well. One pit sit remains open, will close when service rig moves of location. Area has been graded in the past month and lease road into well also graded.
1257450057 2009-10-27 Production Wells No Violations - Pump jack not operating while on site. ID on tank and well.
1260045551 2008-04-08 Preliminary Restoration No Violations - Operator on site filling in ditch that contains flow line from pump jack to tanks. Area has been graded and pump unit in place. ID on tank. Well will be put into production today.
1291743066 2010-12-07 Production Wells No Violations - ID on well and tank. Pump jack not operating while on site. Water meter removed.

- Tank dike area clean and free of water, Weather partly sunny Temp 15 windy

1293288733 2012-08-08 Production Wells No Violations - pump jack operating while on site. ID on tank and well.

- Water meter reading 380030 gallons = 9,048 barrels

1368361191 2011-06-30 Production Wells No Violations - Pump jack operating while on site, ID on well and tank, Dike area free of debris. Water meter reading 304370 gallons = 7,246 barrels.
1378493510 2019-01-24 Production Wells No Violations My inspection revealed this well is incapable of production. The well consists of a wellhead with tubing and rods. The well was cited for 12B, well shall be plugged. I have been in contact with well owner Layline Oil And Gas. I have received a plugging plan and they are applying for a plugging permit.
1522343319 2013-01-24 Production Wells No Violations - ID on tank, tank dike area free of water and debris.

- Pump unit not operating while on site. - Weather condition partly sunny temp 15

1554370510 2009-06-10 Production Wells No Violations - ID on tank and well, pump jack not operating while on site.
1601341766 2008-09-11 Production Wells No Violations - Pump unit not operating while on site. ID on tank.
1643922996 2015-05-27 Production Wells No Violations Production well inspection. The well is being serviced. No pumping unit on the well. I will respect at a later date to check the status of the well.
1837858644 2008-06-11 Production Wells Violations Noted - New tank in place no ID, pump unit operating while on site. Met with operator employee and asked to have ID place on well and tank.
1948194352 2014-09-23 Production Wells No Violations - Inspection, ID on well and tank

- Pump unit not operating while on site. - Dike area free of debris, five 210 barrel tanks in dike area which are shared with well 34-129-20036. -

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1837858644 US-OH-118349 2008-06-23 Failure to legibly identify well

For data sources see[8]