Line 11: Line 11:
 
| County: [[Washington_County,_Ohio|Washington]]
 
| County: [[Washington_County,_Ohio|Washington]]
 
|-
 
|-
| Municipality: [[Muskingum_Township,_Washington_County,_Ohio|Muskingum Township]]
+
| Municipality: [[Muskingum Township,_Washington_County,_Ohio|Muskingum Township]]
 
|-
 
|-
 
| Operator Name: [[HISTORIC OWNER]]
 
| Operator Name: [[HISTORIC OWNER]]

Revision as of 14:45, 15 August 2019

Well Details

Well ID: 34-167-23792
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Muskingum Township
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: FORMA SCIENTIFIC INC
License Status: Historical Production Well
License Date: 1977-06-15
Spud Date: 1977-06-14
Spud Drilling Contractor:
Final Drill Date: 1977-07-13
Well Total Depth: 2400 ft
Configuration: Vertical
Latitude: 39.445773737
Longitude: -81.44353986

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1977-06-14
Completed 1977-07-13
Reached Total Depth 1977-07-13
Record Last Modified 2012-09-28

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1897 1900 9
2006-09-11 2239 2265 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3080 Bbl 80000

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0616986346 2008-09-23 Production Wells No Violations Inspection this day found well with no IDs, jack on well and is producing, has fence around jack, tank has good dike. Used for the factory.

For data sources see[5]

References