Line 11: Line 11:
 
| County: [[Carroll_County,_Ohio|Carroll]]
 
| County: [[Carroll_County,_Ohio|Carroll]]
 
|-
 
|-
| Municipality: [[Orange_Township,_Carroll_County,_Ohio|Orange Township]]
+
| Municipality: [[Orange Township,_Carroll_County,_Ohio|Orange Township]]
 
|-
 
|-
 
| Operator Name: [[ENERVEST OPERATING LLC]]
 
| Operator Name: [[ENERVEST OPERATING LLC]]

Revision as of 15:14, 15 August 2019

Well Details

Well ID: 34-019-20773
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Orange Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: LEEPER-RUMMEL-RIPPETH UNIT
License Status: Producing
License Date: 1974-05-01
Spud Date: 1974-05-04
Spud Drilling Contractor:
Final Drill Date: 1974-05-14
Well Total Depth: 5656 ft
Configuration: Vertical
Latitude: 40.441484966
Longitude: -81.24383744

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1974-05-01 133 QUAKER STATE OIL REF CORP GeoDate 5/1/74
Original Spud 1974-05-04
Completed 1974-05-14
Reached Total Depth 1974-05-14
Construction Permit Expires 1975-05-01
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 5/1/74
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5604 5644 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 3901 Bbl 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP 2486 783 0
1985 QUAKER STATE OIL REF CORP 2085 393 365
1986 QUAKER STATE OIL REF CORP 955 609 365
1987 QUAKER STATE OIL REF CORP 1660 913 365
1988 QUAKER STATE OIL REF CORP 2321 692 365
1989 QUAKER STATE OIL REF CORP 2311 717 365
1990 QUAKER STATE OIL REF CORP 2097 670 365
1991 QUAKER STATE OIL REF CORP 2175 572 365
1992 QUAKER STATE OIL REF CORP 1622 501 365
1993 QUAKER STATE OIL REF CORP 1452 425 365
1994 QUAKER STATE OIL REF CORP 1178 287 365
1995 BELDEN & BLAKE CORPORATION 392 476 137
1996 BELDEN & BLAKE CORPORATION 972 857 209
1997 BELDEN & BLAKE CORPORATION 762 850 308
1998 BELDEN & BLAKE CORPORATION 1002 478 194
1999 BELDEN & BLAKE CORPORATION 535 0 3
2000 BELDEN & BLAKE CORPORATION 478 350 319
2001 BELDEN & BLAKE CORPORATION 1269 527 354
2002 BELDEN & BLAKE CORPORATION 1172 569 353
2003 BELDEN & BLAKE CORPORATION 1373 416 361
2004 BELDEN & BLAKE CORPORATION 1014 467 355
2005 BELDEN & BLAKE CORPORATION 975 362 346
2006 BELDEN & BLAKE CORPORATION 392 266 346
2007 ENERVEST OPERATING LLC 3 334 365
2008 ENERVEST OPERATING LLC 15 197 365
2009 ENERVEST OPERATING LLC 296 224 365
2010 ENERVEST OPERATING LLC 423 180 365
2011 ENERVEST OPERATING LLC 654 132 0
2012 ENERVEST OPERATING LLC 325 233 366
2013 ENERVEST OPERATING LLC 471 253 365
2014 ENERVEST OPERATING LLC 981 213 365
2015 ENERVEST OPERATING LLC 890 169 365
2016 ENERVEST OPERATING LLC 640 89 366
2017 ENERVEST OPERATING LLC 1009 87 365
2018 ENERVEST OPERATING LLC 1240 93 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP Brine 0 0
1985 QUAKER STATE OIL REF CORP Brine 70 365
1986 QUAKER STATE OIL REF CORP Brine 400 365
1987 QUAKER STATE OIL REF CORP Brine 400 365
1988 QUAKER STATE OIL REF CORP Brine 387 365
1989 QUAKER STATE OIL REF CORP Brine 400 365
1990 QUAKER STATE OIL REF CORP Brine 420 365
1991 QUAKER STATE OIL REF CORP Brine 287 365
1992 QUAKER STATE OIL REF CORP Brine 260 365
1993 QUAKER STATE OIL REF CORP Brine 253 365
1994 QUAKER STATE OIL REF CORP Brine 140 365
1995 BELDEN & BLAKE CORPORATION Brine 95 137
1996 BELDEN & BLAKE CORPORATION Brine 124 209
1997 BELDEN & BLAKE CORPORATION Brine 422 308
1998 BELDEN & BLAKE CORPORATION Brine 192 194
1999 BELDEN & BLAKE CORPORATION Brine 8 3
2000 BELDEN & BLAKE CORPORATION Brine 79 319
2001 BELDEN & BLAKE CORPORATION Brine 152 354
2002 BELDEN & BLAKE CORPORATION Brine 128 353
2003 BELDEN & BLAKE CORPORATION Brine 151 361
2004 BELDEN & BLAKE CORPORATION Brine 158 355
2005 BELDEN & BLAKE CORPORATION Brine 194 346
2006 BELDEN & BLAKE CORPORATION Brine 84 346
2007 ENERVEST OPERATING LLC Brine 139 365
2008 ENERVEST OPERATING LLC Brine 52 365
2009 ENERVEST OPERATING LLC Brine 46 365
2010 ENERVEST OPERATING LLC Brine 30 365
2011 ENERVEST OPERATING LLC Brine 96
2012 ENERVEST OPERATING LLC Brine 93 366
2013 ENERVEST OPERATING LLC Brine 84 365
2014 ENERVEST OPERATING LLC Brine 37 365
2015 ENERVEST OPERATING LLC Brine 71 365
2016 ENERVEST OPERATING LLC Brine 57 366
2017 ENERVEST OPERATING LLC Brine 84 365
2018 ENERVEST OPERATING LLC Brine 59 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1115730272 2017-02-27 Production Wells No Violations The well is equipped with an electrically-driven pumpjack and was producing at the time of inspection. The tank battery shares production equipment with PN# 20771& 20772 consist of two 210 bbl production tanks, one vertical separator, one drip bottle , one digital meter,, one meter run, one horizontal separator, and one heater treater. One underground steel brine tank was located outisde of the dike surrounding the tank battery. The load line to the tanks production valve was equipped with locks and plugs. The tank battery shares a dike with the production equipment belonging to PN# 20797. Proper identification was posted at the well and tank battery.
1618107637 2017-07-18 Production Wells No Violations I followed up on this location after my request to the operator to repair the driveway at the location that the flowline was repaired during the week of 06/26/2017. The location of the incident appears to have been stabilized and is drivable. The production valves at the wellhead were in the open position. No violations were noted at the time of inspection.
1706340702 2017-07-03 Production Wells No Violations I conducted a status check in response to a flowline break that resulted in a gas release which occurred on 07/01/2017 and was reported to DOGRM Emergency Response. The failed flowline belonged to PN# 20772, but shares a common tank battery with this well. The ground has not yet been excavated at the location of the leak. The wells PN# (20772, 20773, 20771) were shut-in until Enervest could repair the damaged line. The well is equipped with an electrically-driven pumpjack. The tank battery is shared with Petrox PN # 20797 and Enervest PN#s (20772 and 20771) and identification was posted for all four wells. The tank battery consists of two 210 bbl production tanks labelled as belonging to Petrox and one 210 bbl production tank labelled as belonging to Enervest, two vertical separators, one horizontal separator, one heat treater, and three meter runs. Identification was posted at the well and tank battery. The lease road was stable

For data sources see[9]