If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Washington_County,_Ohio|Washington]] | | County: [[Washington_County,_Ohio|Washington]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Adams Township,_Washington_County,_Ohio|Adams Township]] |
|- | |- | ||
| Operator Name: [[BIEHL ALVIN]] | | Operator Name: [[BIEHL ALVIN]] |
Well ID: 34-167-25354 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.551157484,"lon":-81.53537133,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Washington | |
Municipality: Adams Township | |
Operator Name: BIEHL ALVIN | |
Well Pad ID: | |
Farm/Lease Name: BIEHL ALVIN & DELMAR | |
License Status: Domestic Well | |
License Date: 1980-02-25 | |
Spud Date: 1980-03-17 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-03-20 | |
Well Total Depth: 1938 ft | |
Configuration: Vertical | |
Latitude: 39.551157484 | |
Longitude: -81.53537133 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-02-25 | 2125 EASTERN PETROLEUM CO GeoDate 2/25/80 |
Original Spud | 1980-03-17 | PERMIT EXPIRED CHANGED STATUS FROM PR TO DM PER TRANSFER FROM G-R CONTRACTING, INC. ON 12/30/2014 CM. |
Completed | 1980-03-20 | PERMIT EXPIRED CHANGED STATUS FROM PR TO DM PER TRANSFER FROM G-R CONTRACTING, INC. ON 12/30/2014 CM. |
Reached Total Depth | 1980-03-20 | PERMIT EXPIRED CHANGED STATUS FROM PR TO DM PER TRANSFER FROM G-R CONTRACTING, INC. ON 12/30/2014 CM. |
CO | 1993-01-20 | 1619 BROWN PHILLIP OIL & GAS GeoDate 2/25/80 |
Change of Owner | 2002-06-10 | Operator changed from 1619, BROWN PHILLIP H JR. CORPORATIO to 952, G-R CONTRACTING INC |
Change of Owner | 2014-12-30 | Operator changed from 952, G-R CONTRACTING INC to 9409, BIEHL ALVIN |
Record Last Modified | 2019-06-04 | PERMIT EXPIRED CHANGED STATUS FROM PR TO DM PER TRANSFER FROM G-R CONTRACTING, INC. ON 12/30/2014 CM. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1842 | 1848 | 6 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 43000 Gal | 35000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0468010925 | 2014-12-03 | Exempt Well Pre Transfer | No Violations | Performed an inspection on this well in response to a request from ODNR DOGRM Bonding Section. Upon inspection, it was observed that this well is equipped for both domestic and production use. The well consists of an electrically powered pumping unit standing over 7 surface casing, 4.5 intermediate casing, and 2.375 tubing. The valve on the 4.5 casing is in the open position and runs into a domestic regulator, a drip, and out to Mr. Alvin Biehls residence on Laurel Ridge Road. The valve on the 2.275 tubing is also open and runs to a 2 poly flow line which runs to the tank battery near the road. The tank battery consists of 2 mechanical separators, (2) 100 bbl production tanks, and a meter run. The separators and the meter run are bypassed and the flow lines run directly into the tanks. The identification information posted on the tanks is from G-R Contracting, Inc. I spoke with the landowner, Mr. Delmar Biehl, in person and told him that new IDs must be posted at the well head and tank battery with new ownership information once the well is transferred into his and/or his brothers name. No significant violations were observed on this location that would prevent the transfer of ownership. |
1216217287 | 2008-07-15 | Production Wells | No Violations | Inspection this day found jack that was capable but no tanks, no IDs. Closest tanks are not for this well and landowner not home to help clarify. |
For data sources see[9]