Line 297: Line 297:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 302: Line 303:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-S01
+
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,965.60 Bbl
 
| style="text-align: right;" | 1,965.60 Bbl
Line 308: Line 310:
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2012-S01
+
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 126.00 Bbl
 
| style="text-align: right;" | 126.00 Bbl
Line 314: Line 317:
 
|  
 
|  
 
|-
 
|-
| 2012-S02
+
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracing Fluid Waste (in Barrels)
 +
| style="text-align: right;" | 163.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2012
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 0.73 Tons
 
| style="text-align: right;" | 0.73 Tons
Line 320: Line 331:
 
| 100419
 
| 100419
 
|-
 
|-
| 2012-S02
+
| 2013
| Fracing Fluid Waste (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 163.00 Bbl
+
| Fracturing Fluid Waste (in Tons)
| REUSE OTHER THAN ROAD SPREADING
+
| style="text-align: right;" | 4.90 Tons
|  
+
| LANDFILL
 +
| 100419
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 23.56 Tons
 +
| LANDFILL
 +
| 073 114 654
 
|-
 
|-
| 2013-S01
+
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 3,707.50 Bbl
 
| style="text-align: right;" | 3,707.50 Bbl
Line 332: Line 352:
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2013-S01
+
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123SW001
 +
|-
 +
| 2013
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 17,823.60 Bbl
 
| style="text-align: right;" | 17,823.60 Bbl
Line 338: Line 366:
 
|  
 
|  
 
|-
 
|-
| 2013-S01
+
| 2013
| Fracturing Fluid Waste (in Tons)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 4.90 Tons
 
| LANDFILL
 
| 100419
 
|-
 
| 2013-S01
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 3.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123SW001
 
|-
 
| 2013-S01
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 3,381.00 Bbl
+
| style="text-align: right;" | 8,908.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2013-S02
+
| 2013
| Fracturing Fluid Waste (in Tons)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 23.56 Tons
 
| LANDFILL
 
| 073 114 654
 
|-
 
| 2013-S02
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 180.00 Bbl
 
| style="text-align: right;" | 180.00 Bbl
Line 368: Line 380:
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2013-S02
+
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 5,527.00 Bbl
+
| style="text-align: right;" | 2,247.34 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2014-S01
+
| 2014
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 380: Line 394:
 
| 34-121-23995
 
| 34-121-23995
 
|-
 
|-
| 2014-S01
+
| 2015
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 1,258.67 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2014-S02
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 988.67 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2015-S01
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 678.33 Bbl
+
| style="text-align: right;" | 1,051.66 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-S02
+
| 2016
| Produced Fluid (in Barrels)
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 373.33 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2016-S01
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 508.67 Bbl
+
| style="text-align: right;" | 583.67 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2016-S02
+
| 2016
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 408.02 Bbl
 
| style="text-align: right;" | 408.02 Bbl
Line 416: Line 415:
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2016-S02
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 75.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2017-M01
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 73.67 Bbl
+
| style="text-align: right;" | 158.33 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
|-
 
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 73.33 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
|-
 
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 40.00 Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2017-M04
+
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 37.67 Bbl
+
| style="text-align: right;" | 183.67 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
|-
 
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 3,360.00 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
|-
 
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2017-M07
+
| 2017
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 38.00 Bbl
+
| style="text-align: right;" | 3,435.67 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW001
 
| WMGR123SW001
 
|-
 
|-
| 2017-M08
+
| 2017
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 38.33 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 43.33 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M10
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 36.67 Bbl
+
| style="text-align: right;" | 73.34 Bbl
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2017-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2017-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
| 2018-M01
+
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 39.17 Bbl
 
| style="text-align: right;" | 39.17 Bbl
Line 500: Line 450:
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2018-M01
+
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 40.00 Bbl
+
| style="text-align: right;" | 298.00 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
| 2018-M02
+
| 2018
 +
| [[CHEVRON APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 37.33 Bbl
+
| style="text-align: right;" | 153.34 Bbl
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
| 2018-M03
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 37.33 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 80.00 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M05
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| style="text-align: right;" | 33.33 Bbl
Line 536: Line 471:
 
| WMGR123SW005
 
| WMGR123SW005
 
|-
 
|-
| 2018-M06
+
| 2019
| Produced Fluid (in Barrels) RWC 802
+
| [[CHEVRON APPALACHIA LLC]]
| style="text-align: right;" | 36.67 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 33.33 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2018-M11
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 76.67 Bbl
 
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|
 
|-
 
| 2019-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 36.67 Bbl
 
| REUSE (AT WELL PAD)
 
|
 
|-
 
| 2019-M03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
| style="text-align: right;" | 76.67 Bbl
+
| style="text-align: right;" | 113.34 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
 
|  
 
|  

Revision as of 03:59, 21 August 2019

Well Details

Well ID: 37-051-24490
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Springhill Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 147956
Farm/Lease Name: CHICO UNIT 1H
License Status: Active
Spud Date: 2011-10-05
Permit Date: 2012-02-10
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 39.746956
Longitude: -79.858581

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-11-14 2012-11-14 7086.00 4,324,225.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Biocide EC 6116A Nalco Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30.00 0.00745000
Dibromoacetonitrile 3252-43-5 5.00 0.00124000
Polyethylene glycol 25322-68-3 60.00 0.01
ASP 900 Nalco Friction Reducer Ammonium sulfate 7783-20-2 30.00
Proppant (lbs) Proppant 8.00 8.75
EC6486A Nalco Scale Inhibitor Ethylene glycol 107-21-1 30.00 0.00746000
EC6673W Nalco Iron Control Ethylene glycol 107-21-1 30.00 0.00699000
Clean Volume (gals) Carrier/Base Fluid 92.01 100.00
WG-36 GELLING AGENT Halliburton Energy Services Water Viscosifier Guar gum 9000-30-0 100.00 0.00233000
GBW-30 BREAKER Halliburton Energy Services Gel Breaker Carbohydrates 95.00 0.00007000
Hemicellulase enzyme 9012-54-8 15.00 0.00001000
7.5 Hcl Acid Used to open perfs Hydrochloric acid 7647-01-0 7.50 0.30

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 693,033.00 275 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 653,173.00 365 0.00 0 0.00 0
2015 CHEVRON APPALACHIA LLC 466,370.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 396,227.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 320,615.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 248,267.00 334 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 60,840.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 1,965.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2012 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 126.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 163.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 0.73 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 4.90 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 23.56 Tons LANDFILL 073 114 654
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 3,707.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 3.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 17,823.60 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 8,908.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 180.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 2,247.34 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 45.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 1,051.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 583.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 408.02 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 158.33 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 183.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 3,435.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 73.34 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 39.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 298.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 153.34 Bbl REUSE (AT WELL PAD)
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 113.34 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2104999 Primary Facility 2012-10-04 Routine/Complete Inspection No Violations Noted Site ID sign in place, E&S plan, permits, and PPC plan in box, Three wells drilled-not fraced yet. E&S in place and functioning. Well label on 1H and site id sign for 2H need permit numbers changed to reflect correct numbers.
2124993 Primary Facility 2012-12-11 Routine/Complete Inspection No Violations Noted ID sign up, wells labeled, E&S in place and functioning.
2141150 Primary Facility 2013-02-21 Administrative/File Review In Compliance with Policy Operator self reported leak of motor oil from truck. Approx. .012 gallons of motor oil dripped to the ground. The operator reported and cleaned up the spill in compliance with the current Departments spill policy.
2184881 Primary Facility 2013-07-18 Site Restoration No Violations Noted Site restoration extension requested by operator until 12/13/13. Site stable and 90% reclaimed at this time. Request approved.
2357536 Primary Facility 2015-04-01 Site Restoration No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been restored as outlined in the PCSM plan. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2384351 Primary Facility 2015-06-26 Routine/Complete Inspection No Violations Noted On 06/26/15 at approximately 1345 hours I conducted a routine complete inspection of the Chico Unit. The Act 9 sign was in place. The site was very well vegetated. There were no signs of accelerated erosion observed. The wells appeared to be in good condition. There were no violations noted at the time of inspection.
2561647 Primary Facility 2017-02-06 Routine/Complete Inspection No Violations Noted

On 02/06/17 at approximately 1245 hours I conducted a routine complete inspection of the Chico Unit. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection.

2668428 Primary Facility 2017-11-30 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. There were no violations observed at the time of inspection.
2741844 Primary Facility 2018-06-01 Routine/Complete Inspection No Violations Noted The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and there were no signs of erosion observed. The production equipment appeared to be in good condition. There were no violations observed at the time of inspection.

For data sources see[7]