If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 113: | Line 113: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 118: | Line 119: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2011 | + | | 2011 |
+ | | [[CHESAPEAKE APPALACHIA LLC]] | ||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 109.00 Bbl | | style="text-align: right;" | 109.00 Bbl | ||
Line 124: | Line 126: | ||
| | | | ||
|- | |- | ||
− | | 2012 | + | | 2012 |
− | | | + | | [[CHESAPEAKE APPALACHIA LLC]] |
− | |||
− | |||
− | |||
− | |||
− | |||
| Drilling Fluid Waste (in Barrels) | | Drilling Fluid Waste (in Barrels) | ||
| style="text-align: right;" | 1,304.00 Bbl | | style="text-align: right;" | 1,304.00 Bbl | ||
Line 136: | Line 133: | ||
| | | | ||
|- | |- | ||
− | | 2012 | + | | 2012 |
+ | | [[CHESAPEAKE APPALACHIA LLC]] | ||
| Produced Fluid (in Barrels) | | Produced Fluid (in Barrels) | ||
| style="text-align: right;" | 130.00 Bbl | | style="text-align: right;" | 130.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
+ | |- | ||
+ | | 2012 | ||
+ | | [[CHESAPEAKE APPALACHIA LLC]] | ||
+ | | Drill Cuttings (in Tons) | ||
+ | | style="text-align: right;" | 1,150.43 Tons | ||
+ | | LANDFILL | ||
+ | | THR029 | ||
|- | |- | ||
|} | |} |
Well ID: 37-131-20229 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.531219,"lon":-76.115575,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wyoming | |
Municipality: Forkston Township | |
Operator Name: CHESAPEAKE APPALACHIA LLC | |
Well Pad ID: 148313 | |
Farm/Lease Name: FALCONERO N WYO 2H | |
License Status: Plugged OG Well | |
Spud Date: 2011-12-27 | |
Permit Date: 2011-12-08 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.531219 | |
Longitude: -76.115575 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHESAPEAKE APPALACHIA LLC | Drilling Fluid Waste (in Barrels) | 109.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHESAPEAKE APPALACHIA LLC | Drilling Fluid Waste (in Barrels) | 1,304.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHESAPEAKE APPALACHIA LLC | Produced Fluid (in Barrels) | 130.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHESAPEAKE APPALACHIA LLC | Drill Cuttings (in Tons) | 1,150.43 Tons | LANDFILL | THR029 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2031872 | Primary Facility | 2011-12-28 | Drilling/Alteration | No Violations Noted | United drilling on site working. Started yesterday at 12 noon. |
2039267 | Primary Facility | 2012-02-01 | Drilling/Alteration | No Violations Noted | NOMAC 42, Comp. Man - Josh Bradford, checked drillers log - at 752' |
2042780 | Primary Facility | 2012-02-14 | Drilling/Alteration | No Violations Noted | NOMAC 42, Comp Man - Tommy Thompson, Ben Burel |
2046448 | Primary Facility | 2012-02-22 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Ri g has moved off site. No comp. Man on site. Cellar is open - 2 pressure guages w/ 0 psi. Water in cellar - no bubbles. Still moving tanks & equipment off site. |
2049601 | Primary Facility | 2012-03-05 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Well has been plugged. Cellar still open. I had called because casing had been cut off quite deep and permit number was not on cap. A steel I-beam was welded on to extend to about 3' below the surface of the restored grade. A plate w/ well # and name was welded on top ( see Photos) They will now move ahead w/ site restoration. |
2051928 | Primary Facility | 2012-03-20 | Routine/Complete Inspection | No Violations Noted | |
2052987 | Primary Facility | 2012-03-22 | Follow-up Inspection | No Violations Noted | |
2053062 | Primary Facility | 2012-03-23 | Administrative/File Review | No Violations Noted | Information regarding transfer of fill. |
2090793 | Primary Facility | 2012-08-08 | Site Restoration | No Violations Noted | 3 cellars full of water. Well has been plugged. No site restoration has been done. |
2102523 | Primary Facility | 2012-09-26 | Administrative/File Review | No Violations Noted | Received and reviewed Fill Characterization Report. |
2535887 | Primary Facility | 2016-11-14 | Administrative/File Review | No Violations Noted | |
2653022 | Primary Facility | 2017-10-26 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine Inspection of a plugged gas well. The well was never completed and plugged. The plugged well is now cut, capped, and buried below grade. I walked the field where the pad used to be, and checked above well location. No obvious issues were observed. No combustible gas detected. |
For data sources see[6]