If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Columbiana_County,_Ohio|Columbiana]] | | County: [[Columbiana_County,_Ohio|Columbiana]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Butler_Township,_Columbiana_County,_Ohio|Butler Township]] |
|- | |- | ||
| Operator Name: [[EVERFLOW EASTERN PTNS L P]] | | Operator Name: [[EVERFLOW EASTERN PTNS L P]] | ||
Line 33: | Line 33: | ||
| Configuration: Vertical | | Configuration: Vertical | ||
|- | |- | ||
− | | Latitude: | + | | Latitude: 40.836527903 |
|- | |- | ||
| Longitude: -80.88249365 | | Longitude: -80.88249365 |
Well ID: 34-029-21477 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.836527903,"lon":-80.88249365,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Butler Township | |
Operator Name: EVERFLOW EASTERN PTNS L P | |
Well Pad ID: | |
Farm/Lease Name: RHODES | |
License Status: Producing | |
License Date: 1988-12-09 | |
Spud Date: 1988-12-27 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1989-01-04 | |
Well Total Depth: 6105 ft | |
Configuration: Vertical | |
Latitude: 40.836527903 | |
Longitude: -80.88249365 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1988-12-09 | Issued Date 12/9/88 Expired Date 12/9/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06105 Proposed Drill Depth 06105 |
Original Spud | 1988-12-26 | |
Completed | 1989-01-04 | |
Reached Total Depth | 1989-01-04 | |
CO | 1989-01-23 | 84 EVERFLOW EASTERN PTNS L P GeoDate 12/9/88 |
Completion Report Received | 1989-01-25 | |
Construction Permit Expires | 1989-12-09 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5818 | 5972 | 0 |
2006-09-11 | 5860 | 5970 | 50 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 122000 Gal | 70000 | FRAC:SAND/WATER |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1481726496 | 2016-10-25 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check on well # 2-1477. A review of RDBMS indicates the operator is current with reporting production. The well location is within an agricultural field that is stable. Correct and legible identification is present at the well head. The 8.625 surface casing is below grade. The 4.5 production casing is equipped with a plunger lift assembly. The Demco gate valve is in the closed position. No audible or visual leaks were detected. A domestic supply connection is present. Production equipment for well # 2-1477 is within an earthen dike that is shared with #2-1478 and #2-1503. The dike is stable and sufficient for containment. A heavy gauge wire fence is erected around the perimeter. Correct and legible identification for all wells produced through the battery is present on the fence. Equipment contained within the dike consists of two (2) horizontal separators, one (1) vertical separator and one (1) 100 bbl production tank. The separator specific to well # 2-1477 is not identified. Both horizontal separators remained in good repair. No audible or visual leaks were detected. Neither unit contained a current production chart. Production valves were in the closed position. I will contact the Owner to have the separator specific to well #2-1477 identified. |
For data sources see[9]