X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-119-26763"

m
m
Line 11: Line 11:
 
| County: [[Muskingum_County,_Ohio|Muskingum]]
 
| County: [[Muskingum_County,_Ohio|Muskingum]]
 
|-
 
|-
| Municipality: [[Newton Township,_Muskingum_County,_Ohio|Newton Township]]
+
| Municipality: [[Newton_Township,_Muskingum_County,_Ohio|Newton Township]]
 
|-
 
|-
 
| Operator Name: [[JOHNSON OIL & GAS LLC]]
 
| Operator Name: [[JOHNSON OIL & GAS LLC]]

Revision as of 00:29, 29 August 2019

Well Details

Well ID: 34-119-26763
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Newton Township
Operator Name: JOHNSON OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: COLUMBIA CEMENT CORP
License Status: Producing
License Date: 1983-09-20
Spud Date: 1983-11-26
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1983-12-01
Well Total Depth: 3460 ft
Configuration: Vertical
Latitude: 39.851002157
Longitude: -82.10999935

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-09-20 Issued Date 9/20/83 Expired Date 3/18/84 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03460 Proposed Drill Depth 03460
Original Spud 1983-11-26 CHG IN FTG. 10-1-83
Completed 1983-12-01 CHG IN FTG. 10-1-83
Reached Total Depth 1983-12-01 CHG IN FTG. 10-1-83
CO 1984-01-16 1278 CLYMAR, INC GeoDate 9/20/83
Completion Report Received 1984-01-30 CHG IN FTG. 10-1-83
Construction Permit Expires 1984-03-18 CHG IN FTG. 10-1-83
CO 1996-09-17 5512 NEWSTAR ENERGY USA INC GeoDate 9/20/83
Change of Owner 1999-10-12 Operator changed from 5512, NEWSTAR ENERGY USA INC to 5658, PORTER PETROLEUM
Change of Owner 1999-11-16 Operator changed from 5658, PORTER PETROLEUM to 5460, JOHNSON MIKE
Change of Owner 2019-03-26 Operator changed from 5460, JOHNSON MIKE to 10354, JOHNSON OIL & GAS LLC
Record Last Modified 2019-03-26 CHG IN FTG. 10-1-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3320 3370 0
2006-09-11 3324 3360 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 84000 Gal 90000 FRAC;H2O,SAND,ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 CLYMAR, INC 13983 1750 365
1987 FORAKER CLYDE M & ASSOC 8376 1155 365
1988 CLYMAR, INC 5049 772 365
1989 CLYMAR, INC 3084 549 365
1990 CLYMAR, INC 1723 313 365
1991 CLYMAR, INC 706 462 365
1992 CLYMAR, INC 822 399 365
1993 CLYMAR, INC 270 285 365
1994 CLYMAR, INC 118 234 365
1995 CLYMAR, INC 267 153 365
1996 NEWSTAR ENERGY USA INC 192 152 365
1997 NEWSTAR ENERGY USA INC 0 324 365
1999 JOHNSON MIKE 0 159 0
2000 JOHNSON MIKE 0 392 0
2001 JOHNSON MIKE 0 64 365
2002 JOHNSON MIKE 0 169 365
2003 JOHNSON MIKE 0 73 365
2004 JOHNSON MIKE 0 51 365
2005 JOHNSON MIKE 0 21 365
2006 JOHNSON MIKE 0 48 365
2007 JOHNSON MIKE 0 173 365
2008 JOHNSON MIKE 0 71 365
2009 JOHNSON MIKE 0 31 365
2010 JOHNSON MIKE 0 0 365
2011 JOHNSON MIKE 0 92 365
2012 JOHNSON MIKE 0 53 366
2013 JOHNSON MIKE 0 45 365
2014 JOHNSON MIKE 0 71 365
2015 JOHNSON MIKE 0 50 365
2016 JOHNSON MIKE 0 33 365
2017 JOHNSON MIKE 0 29 365
2018 JOHNSON MIKE 0 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 CLYMAR, INC Brine 430 365
1987 FORAKER CLYDE M & ASSOC Brine 299 365
1988 CLYMAR, INC Brine 320 365
1989 CLYMAR, INC Brine 150 365
1990 CLYMAR, INC Brine 160 365
1991 CLYMAR, INC Brine 70 365
1992 CLYMAR, INC Brine 70 365
1993 CLYMAR, INC Brine 100 365
1994 CLYMAR, INC Brine 100 365
1995 CLYMAR, INC Brine 75 365
1996 NEWSTAR ENERGY USA INC Brine 61 365
1997 NEWSTAR ENERGY USA INC Brine 82 365
1999 JOHNSON MIKE Brine 0
2000 JOHNSON MIKE Brine 0
2001 JOHNSON MIKE Brine 0 365
2002 JOHNSON MIKE Brine 0 365
2003 JOHNSON MIKE Brine 0 365
2004 JOHNSON MIKE Brine 0 365
2005 JOHNSON MIKE Brine 0 365
2006 JOHNSON MIKE Brine 0 365
2007 JOHNSON MIKE Brine 0 365
2008 JOHNSON MIKE Brine 0 365
2009 JOHNSON MIKE Brine 0 365
2010 JOHNSON MIKE Brine 0 365
2011 JOHNSON MIKE Brine 0 365
2012 JOHNSON MIKE Brine 0 366
2013 JOHNSON MIKE Brine 0 365
2014 JOHNSON MIKE Brine 0 365
2015 JOHNSON MIKE Brine 0 365
2016 JOHNSON MIKE Brine 0 365
2017 JOHNSON MIKE Brine 0 365
2018 JOHNSON MIKE Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL8314 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0054522588 2016-12-13 Production Wells No Violations The purpose of the inspection is due to a Compliance Follow-up to number 1259235552. The violations to this Compliance Action had been resolved.
0432700908 2014-05-29 Production Wells No Violations I stopped by and looked at the well and tank. The well and the tank have containment around them. The tank that was brought in is leaking thru heat tube. The Compliance Notice did not pass on the day of inspection. I called Mark Hines and he would have welder come in and weld shut.
0626928853 2017-02-02 Production Wells No Violations The purpose of the inspection is due to follow-
1259235552 2014-05-14 Production Wells Violations Noted Well is a producing well with Pumping unit powered by natural gas powered single piston motor. The rod annulus is open for oil production and the tubing annulus is open producing gas for pumping unit motor. There are 2-100 barrel tanks that are leaking at burner tubes and the tanks are decomposing at the bottom. There is a vertical separator that is not connected. There is large separator on a stand that is leaking brine down into containment. Quantabs were used that revealed the Chlorides were above 6775 parts per million. All the piping plumbed into the separator and tanks are leaking and decomposing. The containment that encompasses all equipment is measured by 96 in length and 24 in width. The dike wall measures at 3 across at the fullest point. The dike has been breached by a decomposing pipe and valve and by migration thru the containment walls. There was a brine scald area that measures at approximately 39 x 34. Identification is placed at the tanks but is unreadable. Remove all tanks and plumbing. Remove all contaminated soil and haul to landfill. Replace soil with good top soil. Reseed and mulch as per Best Management and Practices. Replumb and install good tanks. All manifests will be provided to the inspector upon request. Respond to call made by Patrick Shreve by 24 hrs. Company will have 48 hrs to resolve upon receipt of Compliance Notice. Failure to respond will incur in further enforcement action.
1401983028 2014-06-05 Production Wells No Violations I met Clay Johnson and Mark Hines at well site. They have a heater tube dripping and are going to have a welder come out and weld it. They will notify me when the welder is done. We also talked about getting other wells in the vicinity where the lines are not marked to identify them.
1510898055 2014-05-19 Production Wells No Violations The tanks have been picked up and moved and replaced by one 100 barrel tank. The location has been cleaned up. The tank has been diked up. They are still working on site. The contaminated soil has been hauled to Killbarger landfill.
1686095644 2014-05-20 Administrative Inspection No Violations Mark Hines called me on the status of the site. They are done. The pumper will install the identifications at the tanks. There will be a total of two haul tickets for the Killbarger landfill. He will provide at later date.
1903122605 2016-12-13 Production Wells Violations Noted

-100 barrel steel tank with no separator. There is an impoundment that encloses the tank site. The tank and or well needs identified. Immediately stop venting the gas and either affix to a sales line or install a legal flare tube or stack where the gas can be burned off. Company has 30 days to comply and get the issues remedied. Failure to comply may result in further enforcement action. If there are questions please contact Inspector Patrick Shreve at 740-630-6217.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1259235552 US-OH-106956 2017-01-04 Well operation causing pollution and contamination
1259235552 US-OH-106957 2017-01-04 Well insufficiently equipped to prevent escape of oil and gas
1259235552 US-OH-106958 2017-01-04 Failure to legibly identify well
1259235552 US-OH-106959 2017-01-04 Violation of tank spacing requirements
1259235552 US-OH-106960 2017-01-04 No SPCC dike/or failure to keep dike free of water or oil
1903122605 US-OH-119124 2017-03-08 Well insufficiently equipped to prevent escape of oil and gas
1903122605 US-OH-119125 2017-03-08 Failure to legibly identify well
1903122605 US-OH-119126 2017-03-08 Unlawful venting or flaring of gas

For data sources see[9]

References