X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-073-23210"

m
m
Line 11: Line 11:
 
| County: [[Hocking_County,_Ohio|Hocking]]
 
| County: [[Hocking_County,_Ohio|Hocking]]
 
|-
 
|-
| Municipality: [[Ward Township,_Hocking_County,_Ohio|Ward Township]]
+
| Municipality: [[Ward_Township,_Hocking_County,_Ohio|Ward Township]]
 
|-
 
|-
 
| Operator Name: [[SCHMELZER PLUGGING LLC]]
 
| Operator Name: [[SCHMELZER PLUGGING LLC]]

Revision as of 14:55, 30 August 2019

Well Details

Well ID: 34-073-23210
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Ward Township
Operator Name: SCHMELZER PLUGGING LLC
Well Pad ID:
Farm/Lease Name: WICK DOUGLAS
License Status: Producing
License Date: 1987-06-04
Spud Date: 1987-07-22
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1987-09-04
Well Total Depth: 3215 ft
Configuration: Vertical
Latitude: 39.555671804
Longitude: -82.23623968

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1987-06-04 Issued Date 6/4/87 Expired Date 6/3/88 Acres 0000000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03215 Proposed Drill Depth 03215
Original Spud 1987-07-22
Completed 1987-09-04
Reached Total Depth 1987-09-04
CO 1987-10-01 285 WOODYARD DRILLING GeoDate 6/4/87
Completion Report Received 1987-11-16
Construction Permit Expires 1988-06-03
CO 1993-08-06 2573 JOHNSON M & GINGERICH M GeoDate 6/4/87
CO 1996-04-18 5460 JOHNSON MIKE GeoDate 6/4/87
Change of Owner 2014-04-30 Operator changed from 5460, JOHNSON MIKE to 8565, SCHMELZER PLUGGING LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3184 3210 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 FRAC'D

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 JOHNSON M & GINGERICH M 0 149 295
1994 JOHNSON M & GINGERICH M 0 229 365
1996 JOHNSON MIKE 0 247 365
1999 JOHNSON MIKE 0 19 0
2000 JOHNSON MIKE 0 48 0
2001 JOHNSON MIKE 0 72 365
2002 JOHNSON MIKE 0 154 365
2003 JOHNSON MIKE 0 103 365
2004 JOHNSON MIKE 0 38 365
2005 JOHNSON MIKE 0 55 365
2006 JOHNSON MIKE 0 52 365
2007 JOHNSON MIKE 0 202 365
2008 JOHNSON MIKE 0 307 365
2011 JOHNSON MIKE 0 231 365
2012 JOHNSON MIKE 0 229 366
2013 JOHNSON MIKE 0 161 365
2014 JOHNSON MIKE 0 0 114
2015 SCHMELZER PLUGGING LLC 0 332 365
2016 SCHMELZER PLUGGING LLC 0 273 365
2017 SCHMELZER PLUGGING LLC 0 416 360
2018 SCHMELZER PLUGGING LLC 0 271 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 JOHNSON M & GINGERICH M Brine 0 295
1994 JOHNSON M & GINGERICH M Brine 0 365
1996 JOHNSON MIKE Brine 0 365
1999 JOHNSON MIKE Brine 0
2000 JOHNSON MIKE Brine 0
2001 JOHNSON MIKE Brine 0 365
2002 JOHNSON MIKE Brine 0 365
2003 JOHNSON MIKE Brine 0 365
2004 JOHNSON MIKE Brine 0 365
2005 JOHNSON MIKE Brine 0 365
2006 JOHNSON MIKE Brine 0 365
2007 JOHNSON MIKE Brine 0 365
2008 JOHNSON MIKE Brine 0 365
2011 JOHNSON MIKE Brine 0 365
2012 JOHNSON MIKE Brine 0 366
2013 JOHNSON MIKE Brine 0 365
2014 JOHNSON MIKE Brine 114
2015 SCHMELZER PLUGGING LLC Brine 0 365
2016 SCHMELZER PLUGGING LLC Brine 0 365
2017 SCHMELZER PLUGGING LLC Brine 0 360
2018 SCHMELZER PLUGGING LLC Brine 0 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000014143 Preliminary Restoration No Violations PASSED Y WITNESSED 12/7/89 INSPECTOR DATE 12/0719/89 DATA FROM OLD VAX INFO
00001269i7 2001-01-16 Production Wells No Violations AN INSPECTION OF THE WELL REVEALED THAT THE COMPANY IS FLARING GAS OFF INTO THE AIR WITH OUT A CONTROL DEVISE OR OTHER MEANS OF CONTROL . GAS MUST BE FLARED IF VENTED INTO THE AIR . ALSO THE STUFFING BOX IS LEAKING ALLOWING OIL TO FLOW AROUND THE WELL HEAD , OILY SOIL AND GRAVEL NEEDS CLEANED UP AND STUFFING BOX FIXED. CHECK ID AND CORRECT IF NEEDED.
000PL16033 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0350985023 2003-10-21 Annular Disposal Violations Noted An inspection of the well site revealed no ID at well, no dike around well head or tank battery, creek running approx. 3ft from production tank and 10ft from well head. 10/21/03 FOLLOW-UP ON NOV, NON-COMPLIANCE, NO ACTION TO COMPLY WITH NOV. 12/23/03 In-Complaince.
0374928184 2003-12-23 Annular Disposal No Violations Follow-up on NOV, In-Compliance.
0439941334 2013-03-11 Production Wells Violations Noted Production well inspection, this well consists of 1-100 barrel tank and a pumping unit. There is no legible identification and the stuffing box needs repaired. A tributary of Monday creek if flowing 12 from the dike, it is starting to erode the dike.
0442571381 2009-05-21 Production Wells Violations Noted An inspection revealed unlawful venting of gas without the use of a flare and missing identification. It was also noted that the earthen dike placed around the 100 bbl tank did not contain a front wall for containment. A tributary of Monday Creek, Lost Run, was observed behind the tank location approximately 100 feet away. A second 100 bbl tank was observed near well location and found not connected to the well operation. The tank is located approximately 75 feet away from first tank. The valve on the bottom of this tank (load line) was found open and showed signs of leakage as approx 2 x 2 area of oil was observed. The tank was empty at the time of the inspection. Plastic lines found connected from well head, 4.5 casing were traced to area in the woods and within close proximity to the tributary. At the time of the inspection, the valve was closed at well head and lines were found cut. There were no connections observed from the tank to this location or routed to the well for annular disposal. Note: The well is located on property that had been mined for coal. Records indicate that no brine has been reported for this well from 1993 to 2008.
1042985024 2014-12-11 Production Wells No Violations Compliance notice follow-up. The well has a legible identification and the dike has been repaired. This satisfies the compliance notice.
1167400799 2007-11-23 Production Wells No Violations No violations were noted.
1887252188 2001-01-16 Production Wells No Violations FOLLOW UP TO NOV # 1269i7 AN INSPECTION OF THE WELL REVEALED THAT THE COMPANY IS FLARING GAS OFF INTO THE AIR WITH OUT A CONTROL DEVISE OR OTHER MEANS OF CONTROL . GAS MUST BE FLARED IF VENTED INTO THE AIR . ALSO THE STUFFING BOX IS LEAKING ALLOWING OIL TO FLOW AROUND THE WELL HE
1900713364 2009-07-22 Production Wells No Violations A follow-up inspection revealed compliance.
1966620448 2009-07-06 Production Wells No Violations A follow-up inspection revealed non-compliance. It was noted that a dike wall has been built for front section of dike. Contamination and pollution still exists around abandoned 100 bbl tank location. No pads observed.
2025728811 2006-12-12 Production Wells No Violations No violations were noted.
2069768924 2017-02-07 Production Wells No Violations Production well inspection. The well consists of a pumping unit and 1-100 barrel tank Accurate and legible identification was posted. No violations noted.
2137079268 2009-06-18 Production Wells No Violations A follow-up inspection revealed non-compliance. 1 pad was found placed on the ground surface at the abandoned tank location for oil.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0350985023 US-OH-123681 2003-09-09 Failure to legibly identify well
0350985023 US-OH-123682 2003-09-09 No SPCC dike/or failure to keep dike free of water or oil
0439941334 US-OH-124739 2013-03-25 Well operation causing pollution and contamination
0439941334 US-OH-124740 2013-03-25 Failure to legibly identify well
0442571381 US-OH-124765 2009-05-29 Well operation causing pollution and contamination
0442571381 US-OH-124766 2009-06-03 Failure to legibly identify well
0442571381 US-OH-124767 2009-05-29 No SPCC dike/or failure to keep dike free of water or oil
0442571381 US-OH-124768 2009-05-29 Unlawful venting or flaring of gas

For data sources see[9]

References