Well ID: 34-035-21878 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.469741656,"lon":-81.51988362,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Beachwood | |
Operator Name: PEP DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: CANTERBURY GOLF COURSE | |
License Status: Producing | |
License Date: 2006-01-06 | |
Spud Date: 2006-02-01 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 2006-02-11 | |
Well Total Depth: 3894 ft | |
Configuration: Directional | |
Latitude: 41.469741656 | |
Longitude: -81.51988362 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2006-01-05 | Proposed Formations:CLINTON, Issued Date:1/5/2006, Expired Date:1/5/2007 6:00:00 AM, Drilling unit acres:31.902, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2006-01-06 | Proposed Formations:CLINTON, Issued Date:1/6/2006, Expired Date:1/6/2007 6:00:00 AM, Drilling unit acres:49.33, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2006-02-01 | RBDMS Rec |
Completed | 2006-02-11 | RBDMS Rec |
Reached Total Depth | 2006-02-11 | RBDMS Rec |
Completion Report Received | 2006-12-06 | RBDMS Rec |
Construction Permit Expires | 2007-01-06 | RBDMS Rec |
Correction to Well | 2008-08-29 | CORRECTION TO TARGET INFORMATION, NEW FOOTAGE= 1137'NL & 1007'WL OF LOT 47; X= 2,267, 737, Y= 658, 050 AND ELEV. = 1125'. UNIT SIZE INCREASED TO 135.02 ACRES. |
Change of Owner | 2016-03-04 | Operator changed from 1198, PIPES PURSIE E to 9640, PEP DRILLING LLC |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2007-02-01 | 3688 | 3700 | 118 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 2650 Bbl | 15500 | 1000 GALLONS ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | PIPES PURSIE E | 33898 | 484 | 263 |
2007 | PIPES PURSIE E | 35431 | 281 | 365 |
2008 | PIPES PURSIE E | 24784 | 222 | 365 |
2009 | PIPES PURSIE E | 18763 | 155 | 365 |
2010 | PIPES PURSIE E | 14059 | 83 | 365 |
2011 | PIPES PURSIE E | 11580 | 58 | 365 |
2012 | PIPES PURSIE E | 10790 | 82 | 366 |
2013 | PIPES PURSIE E | 8948 | 87 | 365 |
2014 | PIPES PURSIE E | 8795 | 80 | 365 |
2016 | PEP DRILLING LLC | 4500 | 20 | 365 |
2017 | PEP DRILLING LLC | 3520 | 21 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | PIPES PURSIE E | Brine | 843 | 263 |
2007 | PIPES PURSIE E | Brine | 272 | 365 |
2008 | PIPES PURSIE E | Brine | 161 | 365 |
2009 | PIPES PURSIE E | Brine | 175 | 365 |
2010 | PIPES PURSIE E | Brine | 78 | 365 |
2011 | PIPES PURSIE E | Brine | 47 | 365 |
2012 | PIPES PURSIE E | Brine | 23 | 366 |
2013 | PIPES PURSIE E | Brine | 80 | 365 |
2014 | PIPES PURSIE E | Brine | 70 | 365 |
2016 | PEP DRILLING LLC | Brine | 0 | 365 |
2017 | PEP DRILLING LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0088739035 | 2017-08-31 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The wellhead plunger-lift unit and associated tank battery are located on the grounds of a golf course facility . At the time of this inspection, I observed the following: the well and tank battery chain-link enclosures were locked and secure. The battery is shared with the #1 and #3 wells, also located on the golf course facility. Fittings and connections were secure and free from signs of leakage or problems. The secondary containment was intact. I walked the areas surrounding the well and battery and found the natural greenscape to be free from signs of impact. |
0632446041 | 2014-06-19 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of regular site check and inspection activity. The well was completed on 12/06/2006. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located in a closed and locked chain-link enclosure. The 8 5/8 casing is valved to surface but not gauged. There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located southeast of the wellhead, behind the maintenance shop office. The battery is comprised of 3 steel 100-barrel production tanks, and a 3 horizontal separators, which are shared with the #2-1879 and #2-1881 units. The battery is located in a separate chain-link enclosure which is gated and locked. The load-outs are bull-plugged and locked. There is process safety equipment in use (carbon filter, low-pressure relief valve, and spark arrestor). The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area of the well is generally level with a slight topographic drop to the southeast. Surface drainage is towards a small creek which travserses the rear of the maintenance shop. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by entry to the Canterbury Golf Club off of Halburton Rd. There is no designated access routes or roadway for the well. Beyond the area cleared for the wellhead and tank battery, the area is occupied by the Canterbury Golf Club, the grounds of which are comprised of golf course and clubhouse. The wellhead and battery are located near the maintenance shop. The general landscaping and appearance of the well and battery is good and well maintained. |
0709281516 | 2006-12-03 | Drill / Deepen / Reopen | No Violations | surface |
1142960606 | 2009-11-12 | Production Wells | No Violations | no violation. |
1695323677 | 2006-02-13 | Drill / Deepen / Reopen | No Violations | making location |
1965877078 | 2006-11-14 | Preliminary Restoration | No Violations |
For data sources see[9]