X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-035-22066"

m
m
Line 11: Line 11:
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
| County: [[Cuyahoga_County,_Ohio|Cuyahoga]]
 
|-
 
|-
| Municipality: [[Gates Mills Village,_Cuyahoga_County,_Ohio|Gates Mills Village]]
+
| Municipality: [[Gates Mills,_Cuyahoga_County,_Ohio|Gates Mills]]
 
|-
 
|-
 
| Operator Name: [[PIN OAK ENERGY PARTNERS LLC]]
 
| Operator Name: [[PIN OAK ENERGY PARTNERS LLC]]
Line 33: Line 33:
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Latitude: <Latitude>
+
| Latitude: 41.552295865
 
|-
 
|-
 
| Longitude: -81.40880844
 
| Longitude: -81.40880844

Revision as of 20:49, 30 August 2019

Well Details

Well ID: 34-035-22066
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Gates Mills
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: BOGOMOLNY UNIT
License Status: Producing
License Date: 2008-09-02
Spud Date: 2008-11-13
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2008-11-19
Well Total Depth: 3430 ft
Configuration: Vertical
Latitude: 41.552295865
Longitude: -81.40880844

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-02 Proposed Formations:CLINTON, Issued Date:9/2/2008, Expired Date:9/2/2009 6:00:00 AM, Drilling unit acres:42.1998, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2008-10-03 ADDED X,Y COORDINATE TO DATABASE: X= 2,298,670 AND Y= 688,849.
Reached Total Depth 2008-11-19 LOG TD TAKEN FROM CASED HOLE; COULD NOT GET OPEN-HOLE LOG TO BOTTOM
Completion Report Received 2009-01-13 LOG TD TAKEN FROM CASED HOLE; COULD NOT GET OPEN-HOLE LOG TO BOTTOM
Correction to Well 2009-07-10 UNIT SIZE DECREASED TO 25.4998 ACRES.
Construction Permit Expires 2009-09-02 LOG TD TAKEN FROM CASED HOLE; COULD NOT GET OPEN-HOLE LOG TO BOTTOM
Change of Owner 2019-05-30 Operator changed from 169, JAMES R SMAIL INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2019-05-30 LOG TD TAKEN FROM CASED HOLE; COULD NOT GET OPEN-HOLE LOG TO BOTTOM

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-01-26 3237 3255 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 73000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 JAMES R SMAIL INC 1745 617 0
2010 JAMES R SMAIL INC 11347 955 365
2011 JAMES R SMAIL INC 58296 1434 365
2012 JAMES R SMAIL INC 33657 647 366
2013 JAMES R SMAIL INC 26228 395 365
2014 JAMES R SMAIL INC 20128 259 365
2015 JAMES R SMAIL INC 24527 233 365
2016 JAMES R SMAIL INC 26235 234 365
2017 JAMES R SMAIL INC 12837 74 365
2018 JAMES R SMAIL INC 19161 119 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 JAMES R SMAIL INC Brine 1690 0
2010 JAMES R SMAIL INC Brine 1237 365
2011 JAMES R SMAIL INC Brine 1837 365
2012 JAMES R SMAIL INC Brine 1941 366
2013 JAMES R SMAIL INC Brine 1947 365
2014 JAMES R SMAIL INC Brine 1407 365
2015 JAMES R SMAIL INC Brine 1911 365
2016 JAMES R SMAIL INC Brine 1708 365
2017 JAMES R SMAIL INC Brine 1212 365
2018 JAMES R SMAIL INC Brine 1495 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0146560125 2017-03-13 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection. At the time of this inspection I observed the following: a wellhead with pump jack system and associated tank battery in separate enclosures which were locked and secure. The valves and connections at both the well and battery were secure and free from signs of leakage. Process safety equipment was present. ID signage was present and accurate. The areas surrounding the well and battery were comprised of fringe areas of shrubbery and grass on a moderate hillslope that drops off to the west towards the Chagrin River, located 1,000 feet to the west. I walked the surrounding areas and found no signs of impacts or degradation. Access to the well and battery was afforded by a dedicated, gravel-paved access road, with a locked access gate. The access road was sound and well drained with no wash-outs or other erosional deficits.
0335196564 2011-12-27 UrbanPreliminary Restoration No Violations On 12/27/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
1026951345 2008-11-18 Drill / Deepen / Reopen No Violations cementing 4.5 casing in
1226155626 2013-02-25 UrbanProduction Wells No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 enclosure. The tank battery is comprised of 1 100-barrel (BBL) tank, 10 BBL poly tank, mechanical separator, and associated piping and appurtenances enclosed in an 8 enclosure. The system is equipped with production safety equipment required by 1509:9-9-05. The loadout lines are locked and the secondary containment is good. I did not observe any leaks, releases, or problems.

For data sources see[9]

References