Well Details

Well ID: 34-099-23149
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Poland Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: ZIMMERMAN
License Status: Producing
License Date: 2011-04-25
Spud Date: 2011-07-31
Spud Drilling Contractor: G & G DRLG
Final Drill Date: 2011-08-02
Well Total Depth: 5855 ft
Configuration: Vertical
Latitude: 41.059617239
Longitude: -80.54788555

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-04-25 Proposed Formations:CLINTON/MEDINA, Issued Date:4/25/2011, Expired Date:4/24/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-08-02
Completion Report Received 2011-09-27
Construction Permit Expires 2012-04-24
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-08 5585 5641 69
2011-12-08 5730 5736 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-08-15 H2O 15 83050 Gal 60000 Universal Well Services Inc. 82 perforations, 13 perf balls dropped. No significant pressure change throughout fracturing procedure.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
0 0 0
2011 BOCOR HOLDINGS, LLC 376 0 127
2012 BOCOR HOLDINGS, LLC 8658 0 366
2013 BOCOR HOLDINGS, LLC 3511 0 365
2014 BOCOR HOLDINGS, LLC 2953 0 365
2015 BOCOR HOLDINGS, LLC 1891 0 368
2016 BOCOR HOLDINGS, LLC 1483 0 365
2017 BOCOR HOLDINGS, LLC 1416 0 365
2018 BOCOR HOLDINGS, LLC 1038 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 BOCOR HOLDINGS, LLC Brine 630 127
2012 BOCOR HOLDINGS, LLC Brine 325 366
2013 BOCOR HOLDINGS, LLC Brine 340 365
2014 BOCOR HOLDINGS, LLC Brine 170 365
2015 BOCOR HOLDINGS, LLC Brine 165 368
2016 BOCOR HOLDINGS, LLC Brine 146 365
2017 BOCOR HOLDINGS, LLC Brine 58 365
2018 BOCOR HOLDINGS, LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0017612493 2011-09-13 Preliminary Restoration No Violations Still grading out top soil, very muddy. Chain link fencing around well head and tank battery, ID sign posted. Still needs seeded. Does not pass Preliminary Restoration at this time.
0701829882 2011-08-02 Drill / Deepen / Reopen No Violations G&H Rig # 91 not drilling, hooking up BOP. Loading pits. Witnessed BOP test - pressured up to 360 psi at 14:54, held for 15 minutes, showed 340 psi at 15:09. No leaks or spills. No violations at this time.
0754814357 2011-08-23 Preliminary Restoration No Violations Pits closed but mounds of top soil still surround location. Crew is on site constructing tank battery and running production line. Does not pass Preliminary Restoration at this time.
0850137557 2011-08-11 Preliminary Restoration No Violations Pits still open, top soil berms and orange fences around pits. Crew moving frac tanks onto location. No violations at this time.
1227712089 2011-10-13 Preliminary Restoration No Violations All top soil graded out but not seeded. Area to be planted with agricultural crops per restoration plan. Chain link fencing installed around well head and tank battery and ID sign posted. Locking tube gate installed at lease road entrance. This site passes Preliminary Restoration.
1312485055 2011-08-04 Drill / Deepen / Reopen No Violations G&H Rig #91 drilling on air, at a depth of 3896. Permit properly displayed in doghouse and at lease road entrance. H2S gas detector on rig, 300 bbl brine in pit. Walked site. Pit liners in good condition. No leaks or spills. No violations at this time.
1313752075 2011-08-15 Completion Testing No Violations On site to witness frac job. Pit liners in good condition. Universal Well Service conducting frac job. No fluid returns from annulus observed during or after frac job. No leaks or spills. No violations at this time.
1417182919 2011-08-01 Drill / Deepen / Reopen No Violations G&H Rig #91 drilling on fluid. At depth of 280. Permit properly displayed in doghouse and at lease road entrance. H2S gas detector on rig. Security fence in place around pits. Walked site. Pit liners in good condition. Silt fence in place along west side of location. No leaks or spills. No violations at this time.
1528994163 2018-06-11 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-3149. On 6/08/2018 a local resident reported a gas release from the tank battery. ODNR-DOGRM Emergency operations and response coordinator Fred Romeo responded to the incident with local fire personnel. RBDMS indicated reported production was current. Access to the well and tank battery remained drivable and stable. The well was located within a locked chain-link fence enclosure. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. The master gate valve was closed. No leaks were observed. A gauge fitted to the tubing string indicated 180 psi. A domestic supply connection was present. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure was present on top of the dike. Equipment on location consisted of one (1) mechanical separator, one (1) 140 bbl production tank and one (1) 50 bbl poly brine tank. The separator was shut in. At the time of my inspection, I did not witness any impact from the gas release. The production tank remained in good repair and contained correct identification. Valves were closed, locked and plugged. The hatch lid of the tank remained unbolted and removed from the tank body. The poly brine tank remained in good repair. The inlet valve was closed. I will contact Bocor Holdings to determine the status of repairs and source of failure.

For data sources see[9]