X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-081-20405"

m
m
Line 11: Line 11:
 
| County: [[Jefferson_County,_Ohio|Jefferson]]
 
| County: [[Jefferson_County,_Ohio|Jefferson]]
 
|-
 
|-
| Municipality: [[Knox Township,_Jefferson_County,_Ohio|Knox Township]]
+
| Municipality: [[Knox_Township,_Jefferson_County,_Ohio|Knox Township]]
 
|-
 
|-
 
| Operator Name: [[FIRSTENERGY GENERATION LLC]]
 
| Operator Name: [[FIRSTENERGY GENERATION LLC]]

Revision as of 15:27, 31 August 2019

Well Details

Well ID: 34-081-20405
Loading map...
Country: United States
State: Ohio
County: Jefferson
Municipality: Knox Township
Operator Name: FIRSTENERGY GENERATION LLC
Well Pad ID:
Farm/Lease Name: ALEXANDER
License Status: Producing
License Date: 1976-11-19
Spud Date: 1976-11-15
Spud Drilling Contractor:
Final Drill Date: 1977-06-16
Well Total Depth: 1525 ft
Configuration: Vertical
Latitude: 40.496930336
Longitude: -80.69079650

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1976-11-15
CO 1976-11-19 2704 PARKS OIL INC GeoDate 11/19/76
Completed 1977-06-16
Reached Total Depth 1977-06-16
CO 1994-05-18 4820 STRIKER ROBERT E GeoDate 11/19/76
Change of Owner 2015-02-05 Operator changed from 4820, STRIKER ROBERT E to 9439, FIRSTENERGY GENERATION LLC
Record Last Modified 2015-02-05

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1412 1418 6

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 12000 Gal 5000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 0 411 0
1985 BELDEN & BLAKE CORPORATION 0 341 0
1986 BELDEN & BLAKE CORPORATION 0 247 365
1987 BELDEN & BLAKE CORPORATION 0 107 365
1994 STRIKER ROBERT E 0 160 365
1997 STRIKER ROBERT E 0 200 365
1999 STRIKER ROBERT E 0 25 30
2001 STRIKER ROBERT E 0 25 30
2002 STRIKER ROBERT E 0 30 30
2003 STRIKER ROBERT E 0 300 365
2004 STRIKER ROBERT E 0 365 365
2005 STRIKER ROBERT E 0 400 365
2006 STRIKER ROBERT E 0 500 365
2007 STRIKER ROBERT E 0 300 365
2008 STRIKER ROBERT E 0 532 365
2009 STRIKER ROBERT E 0 421 365
2010 STRIKER ROBERT E 0 251 365
2011 STRIKER ROBERT E 0 300 365
2012 STRIKER ROBERT E 0 382 366
2013 STRIKER ROBERT E 0 180 365
2014 STRIKER ROBERT E 0 45 90
2016 FIRSTENERGY GENERATION LLC 0 0 0
2017 FIRSTENERGY GENERATION LLC 0 0 0
2018 FIRSTENERGY GENERATION LLC 0 0 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 23 0
1986 BELDEN & BLAKE CORPORATION Brine 6 365
1987 BELDEN & BLAKE CORPORATION Brine 3 365
1994 STRIKER ROBERT E Brine 0 365
1997 STRIKER ROBERT E Brine 0 365
1999 STRIKER ROBERT E Brine 0 30
2001 STRIKER ROBERT E Brine 0 30
2002 STRIKER ROBERT E Brine 0 30
2003 STRIKER ROBERT E Brine 0 365
2004 STRIKER ROBERT E Brine 0 365
2005 STRIKER ROBERT E Brine 0 365
2006 STRIKER ROBERT E Brine 0 365
2007 STRIKER ROBERT E Brine 0 365
2008 STRIKER ROBERT E Brine 0 365
2009 STRIKER ROBERT E Brine 0 365
2010 STRIKER ROBERT E Brine 0 365
2011 STRIKER ROBERT E Brine 0 365
2012 STRIKER ROBERT E Brine 0 366
2013 STRIKER ROBERT E Brine 0 365
2014 STRIKER ROBERT E Brine 0 90
2016 FIRSTENERGY GENERATION LLC Brine 0 0
2017 FIRSTENERGY GENERATION LLC Brine 0 0
2018 FIRSTENERGY GENERATION LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0506866902 2016-08-12 Production Wells No Violations On the date of my inspection I found one 150 barrel tank and one 210 barrel tank. The well is equipped with a pumping unit, rods, 2.375 inch tubing and 4.5 inch tubing. A 2.375 inch pipe runs from the tubing into the 150 barrel tank. Production records end in 2014. There is no visible identification. I spoke with Josh from First Energy Generation LLC, he indicated he would post identification.
1501603950 2017-08-01 Production Wells No Violations On the date of my inspection I was accompanied by Paul Kish, senior environmental specialist with First Energy Corporation. The well is equipped with a pumping unit, rods, 2.375 inch tubing and 4.5 inch casing. There is a valve tied into the casing that is in the open position. A 2.375 inch production line runs from the tubing into a 210 barrel tank through a knock out drum at the top of the tank. There is no valve on the line from the tubing to the tank to shut the well in. There is a 2.375 inch line that runs down the hill to a second 210 barrel tank. Production records end in 2014. There is no identification on either of the tanks or at the wellhead. Paul indicated that First Energy is interested in plugging the well and will begin the process of applying for a permit to do so. They will also work on having identification signs created.
1523030776 2018-04-06 Production Wells No Violations On the day of my inspection I was accompanied by Paul Kist, First Energy representative. The well is equipped with a pumping unit, rods, 2.375 inch tubing and 4.5 inch casing. Casing valve is in the open position. A 2.375 inch production line runs from the tubing into a 210 barrel tank through a knock out drum at the top of the tank. There is no valve on the line from the tubing to the tank to shut the well in. There is a 2.375 inch line that runs down the hill to a second 210 barrel tank. Production records were submitted for 2016. There is no identification on either of the tanks or at the wellhead. First Energy is planning on plugging the well.
1619904543 2013-12-23 Production Wells No Violations On the day of my inspection I witnessed that there was a 150bbl tank and a 210bbl transfer tank. The well was equipped with 4.5 inch casing, 2 inch tubing, rods and a pumping unit. Production records were up to date and no identification was present. I made phone call to Robert E. Striker and advised him of findings and requested a follow-up phone call. He returned phone call and he stated that identification would be in place.
1829047088 2017-07-31 Production Wells No Violations I spoke with Paul Kish (330-436-1428) with First Energy about gaining access to this permit and 2 others on the property nearby. He indicated that he would be the contact regarding the plugging of these wells. He said that he would meet me at the property entrance and that we could go and see the wells on 8/1/17.

For data sources see[9]

References