X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-033-26680"

m (Wiki moved page 033-26680 to 42-033-26680)
m
 
(14 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 033-26680
+
| Well ID: 37-033-26680
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.170092, -78.449767 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.170093, -78.449767 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Clearfield County, Pennsylvania|Clearfield]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Lawrence Township, Clearfield County, Pennsylvania|Lawrence Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[EOG RESOURCES INC|EOG RESOURCES INC]]
+
| County: [[Clearfield_County,_Pennsylvania|Clearfield]]
 +
|-
 +
| Municipality: [[Lawrence Township,_Clearfield_County,_Pennsylvania|Lawrence Township]]
 +
|-
 +
| Operator Name: [[SENECA RESOURCES CO LLC]]
 +
|-
 +
| Well Pad ID: [[147214]]
 
|-
 
|-
 
| Farm/Lease Name: PUNXSUTAWNEY HUNTING CLUB 7H
 
| Farm/Lease Name: PUNXSUTAWNEY HUNTING CLUB 7H
 
|-
 
|-
| First Permit Date: 2008-07-11
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2009-07-28
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2009-08-05
+
| Permit Date: 2008-07-11
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 1
+
| Conservation: No
 
|-
 
|-
| Latitude: 41.170092
+
| Latitude: 41.170093
 
|-
 
|-
 
| Longitude: -78.449767
 
| Longitude: -78.449767
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2008-07-11
 +
| New Permit Application
 +
|-
 +
| 2009-07-28
 +
| Permit Renewal Application
 +
|-
 +
| 2009-08-05
 +
| Performed Spud Operation
 +
|-
 +
| 2009-10-09
 +
| Drilling Completion
 +
|-
 +
| 2009-10-20
 +
| Perforation
 +
|-
 +
| 2010-11-16
 +
| DEVIATED
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Well Inspection Data ==
+
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 1822528
+
|}-->
| 2009-08-13
 
| No Violations Noted
 
| The following items were noted during the inspection: 
 
-Met with Mr. Jason Craft, Tool Pusher
 
-Conductor pipe set at 41'.
 
-Drilling contractor,  Dallas Morris Rig # 8 moving in and rigging up.
 
  
|  
+
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 
|-
 
|-
 +
|}-->
 +
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 1824533
+
| 2008
| 2009-08-13
+
| [[EOG RESOURCES INC]]
| No Violations Noted
+
| style="text-align: right;" | 0.00
| Site inspected with OGI Bruce Jankura. There is no activity on site at this time.  Conductor pipe has been set.  All disturbed areas have been seeded and mulched with about 55% vegetation already grown back in.  Site has brush row reinforced with line of silt fence surrounding parameter.  All E&S control BMPs have been installed properly and are working adequately.  The pit is constructed and lined properly. Liner appears sound with no visible cuts or punctures.  More than 2ft of freeboard is being maintained.  Site Sign and E&S Plan are up the road from site.
+
| style="text-align: right;" | 0
|  
+
| style="text-align: right;" | 0.00
|-
+
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1833342
+
| 2009
| 2009-09-30
+
| [[EOG RESOURCES INC]]
| No Violations Noted
+
| style="text-align: right;" | 0.00
| Site inspected with OGI Supervisor, Bruce Jankura. Drilling was in progress.
+
| style="text-align: right;" | 0
-met on site with John Stedman, Drilling Consultant
+
| style="text-align: right;" | 0.00
-Pit has been closed and drilling was been done on pitless system.  Water was removed from cuttings by a dryer and cuttings were discharged into a container to be hauled off to a landfill later.
+
| style="text-align: right;" | 0
-drill cuttings had consistency of clay, but normally come out as a powder. recent rain dampened them up.
+
| style="text-align: right;" | 0.00
-E&S controls remain in place and adequate. vegetation on disturbed areas has returned to about 15%
+
| style="text-align: right;" | 0
-water from access road is being directed onto site and could potentially create problems
 
 
 
|  
 
 
|-
 
|-
 +
| 2010
 +
| [[EOG RESOURCES INC]]
 +
| style="text-align: right;" | 278,652.19
 +
| style="text-align: right;" | 225
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1834891
+
| 2011
| 2009-09-30
+
| [[EOG RESOURCES INC]]
| No Violations Noted
+
| style="text-align: right;" | 283,536.00
| The following items were noted during the inspection: 
+
| style="text-align: right;" | 365
-Drilling contractor, HWD Rig #4 drilling at 10,749'.  
+
| style="text-align: right;" | 0.00
-met w/ John Stedman, Drilling Consultant, and toured location .
+
| style="text-align: right;" | 0
-Pitless drilling opertion in effect.
+
| style="text-align: right;" | 0.00
-Liner material under tank areaa.
+
| style="text-align: right;" | 0
-Site sign and E & S plan were on site.
 
-E&S BMPs were in place and working adequately.
 
 
 
|  
 
 
|-
 
|-
 +
| 2012
 +
| [[EOG RESOURCES INC]]
 +
| style="text-align: right;" | 228,877.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1852735
+
| 2013
| 2009-12-29
+
| [[EOG RESOURCES INC]]
| Violation(s) Noted
+
| style="text-align: right;" | 173,063.00
| Conducted Inspection with WQS Jessica Miller and WQS Heather Agosta.
+
| style="text-align: right;" | 361
Drilling is completed and a digital meter is connected to well.
+
| style="text-align: right;" | 0.00
Production equipment is on location but not connected to well.
+
| style="text-align: right;" | 0
Frac Tanks are on location.
+
| style="text-align: right;" | 0.00
Service Rig is on location, and there is a trailer backed up to the well head.
+
| style="text-align: right;" | 0
Site ID sign located above location is ripped and nonlegible.
 
 
 
| 578685
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| style="text-align: right;" | 154,287.97
 +
| style="text-align: right;" | 360
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1854541
+
| 2015
| 2010-01-05
+
| [[EOG RESOURCES INC]]
| No Violations Noted
+
| style="text-align: right;" | 139,363.96
| Drilling is completed and a digital meter is connected to well.
+
| style="text-align: right;" | 365
Production equipment is on location, but not connected to well.
+
| style="text-align: right;" | 0.00
Frac Tanks are on location.
+
| style="text-align: right;" | 0
Site ID sign located above location has been replaced.
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[EOG RESOURCES INC]]
 +
| style="text-align: right;" | 115,821.23
 +
| style="text-align: right;" | 309
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1884382
+
| 2017
| 2010-05-12
+
| [[SENECA RESOURCES CO LLC]]
| No Violations Noted
+
| style="text-align: right;" | 99,933.64
| Production well in line with digital meter.
+
| style="text-align: right;" | 311
|  
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[SENECA RESOURCES CO LLC]]
 +
| style="text-align: right;" | 109,619.68
 +
| style="text-align: right;" | 359
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 1954458
+
| 2019
| 2011-03-02
+
| [[SENECA RESOURCES CO LLC]]
| No Violations Noted
+
| style="text-align: right;" | 120,471.52
|  
+
| style="text-align: right;" | 344
|  
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Waste Type
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Quantity
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Disposal Method
!scope="col" | OIL QUANTITY
+
!scope="col" | Waste Facility ID
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2010
| style="text-align:right;" | 105076.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 184.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 4,050.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2010
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 8,350.50 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0101508
 
|-
 
|-
| 2012-1
+
| 2010
| style="text-align:right;" | 123801.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 182.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 2,099.50 Bbl
| style="text-align:right;" | 0.0
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| style="text-align:right;" | 0.0
+
| PA0023213
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2010
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 25.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 
|-
 
|-
| 2011-2
+
| 2011
| style="text-align:right;" | 134876.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 184.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 856.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-133-24096
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2011
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,046.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-049-23127
 
|-
 
|-
| 2011-1
+
| 2011
| style="text-align:right;" | 148660.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 181.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 6,051.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2011
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 108.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0023213
 
|-
 
|-
| 2010-2
+
| 2011
| style="text-align:right;" | 203963.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 184.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 2,795.00 Bbl
| style="text-align:right;" | 0.0
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| style="text-align:right;" | 0.0
+
| PA0101508
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2011
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 389.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 34-099-23127
 
|-
 
|-
| 2010-3
+
| 2011
| style="text-align:right;" | 149378.38
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 83.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 95.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-121-23995
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2011
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 604.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0095273
 
|-
 
|-
| 2009-0
+
| 2012
| style="text-align:right;" | 0.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 0.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 404.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-155-23584
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2012
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 4,288.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2008-0
+
| 2012
| style="text-align:right;" | 0.0
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 0.0
+
| Produced Fluid
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 190.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-155-21893
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 2012
== Waste Data ==
+
| [[EOG RESOURCES INC]]
{| class="wikitable sortable" width="95%"
+
| Produced Fluid
!scope="col" | PERIOD
+
| style="text-align: right;" | 1,139.00 Bbl
!scope="col" | TYPE
+
| INJECTION DISPOSAL WELL
!scope="col" | QUANTITY
+
| 34-155-23795
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 190.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 190.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-151-23420
 
| 34-151-23420
| B & B WELL # 2 (BELDEN & BLAKE)
 
| HARTVILLE
 
| OH
 
 
|-
 
|-
 +
| 2012
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 93.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21438
 +
|-
 +
| 2012
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,118.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 804.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 804.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 525-1
 
| 525-1
| BLAZEK PUMP AND WELL
 
| HIRAM
 
| OH
 
 
|-
 
|-
 +
| 2012
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 803.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-22038
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 93.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 94.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21438
+
| 34-155-23795
| KLEESE #1 (SWIW #18) - KLEESE DEVELOPMENT ASSOCS
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 592.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-20114
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 404.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 210.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23584
+
| 34-133-21076
| KOONTZ #1 DISPOSAL WELL
+
|-
| WARREN
+
| 2013
| OH
+
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 220.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|  
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 41.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23732
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 547.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 204.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23795
+
| 34-155-23759
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 43.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 803.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 105.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-007-22038
+
| 34-155-21447
| PAROBEK #2 (SWIW #12)
 
|
 
| OH
 
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 43.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 173.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 976.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| STORAGE PENDING DISPOSAL OR REUSE
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 396.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21438
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 1118.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 515.40 Bbl
| STORAGE PENDING DISPOSAL OR REUSE
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
|
+
| WMGR123SW018
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
| PA
 
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 207.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 190.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 43.33 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21893
 
| 34-155-21893
| WOLF #1 DISP WELL (PANDER RAY TRUCKING INC)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2013
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 104.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-24096
 
|-
 
|-
| 2010-3
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 3942.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 399.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| INJECTION DISPOSAL WELL
|  
+
| 34-155-21438
| FRAC WATER REUSE
+
|-
|  
+
| 2014
| PA
+
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 305.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-20114
 +
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 633.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23759
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 940.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23732
 
|-
 
|-
| 2010-3
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 4035.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 440.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| STORAGE PENDING DISPOSAL OR REUSE
| PA0101508
+
|  
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 629.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23795
 
|-
 
|-
| 2010-3
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 1395.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 107.50 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0023213
+
| 34-133-20525
| RIDGWAY BOROUGH SEWAGE TREATMENT PLANT
 
| RIDGWAY
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 315.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 
|-
 
|-
| 2010-3
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 50.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 310.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0102784
+
| 34-155-24078
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 105.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-21076
 
|-
 
|-
| 2010-2
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 6333.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 659.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0101508
+
| 34-155-21447
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 221.63 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21893
 
|-
 
|-
| 2010-2
+
| 2014
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 2079.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 190.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR DRILLING OR PLUGGING
 
|
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 221.63 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 +
|-
 +
| 2014
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 221.63 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 +
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 210.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-24096
 +
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 105.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21447
 +
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 105.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24078
 
|-
 
|-
| 2010-2
+
| 2015
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 1402.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 52.50 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0023213
+
| 34-155-2-3794
| RIDGWAY BOROUGH SEWAGE TREATMENT PLANT
 
| RIDGWAY
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 476.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23795
 
|-
 
|-
| 2011-1
+
| 2015
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 389.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 105.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| 34-099-23127
+
| 34-155-21438
| NORTH STAR BRINE DISPOSAL
 
| YOUNGSTOWN
 
| OH
 
 
|-
 
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,182.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23196
 
|-
 
|-
| 2011-1
+
| 2015
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 2795.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 210.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0101508
+
| 34-155-21893
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 210.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 
|-
 
|-
| 2011-1
+
| 2015
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 604.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 210.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0095273
+
| 34-155-21894
| PA BRINE TRT INC - JOSEPHINE PLT, INDIANA COUNTY
 
| JOSEPHINE
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 105.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23759
 
|-
 
|-
| 2011-1
+
| 2015
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 2717.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 2,101.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| INJECTION DISPOSAL WELL
|
+
| 34-155-22403
| REUSE OF BRINE TO FRAC A WELL
 
|  
 
|
 
 
|-
 
|-
 +
| 2016
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 37.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-2-3794
 
|-
 
|-
| 2011-1
+
| 2016
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 108.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 105.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0023213
+
| 34-155-22403
| RIDGWAY BOROUGH SEWAGE TREATMENT PLANT
 
| RIDGWAY
 
| PA
 
 
|-
 
|-
 +
| 2016
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 35.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 
|-
 
|-
| 2011-1
+
| 2016
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 95.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 37.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-121-23995
+
| 34-155-23795
| WARREN DRILLING CO #1 (SWIW #6) HUNTER DISPOSAL
 
| DEXTER CITY
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 322.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24063
 
|-
 
|-
| 2011-2
+
| 2016
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 856.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 2,601.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-133-24096
+
| 34-133-24462
| GROSELLE #2 - SALTYS DISPOSAL WELLS LP
 
| GARRETTSVILLE
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 35.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 
|-
 
|-
| 2011-2
+
| 2016
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 2046.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 35.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-049-23127
+
| 34-155-21893
| NORTH STAR
+
|-
| YOUNGSTOWN
+
| 2017
| OH
+
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 10.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC003
 
|-
 
|-
 +
| 2017
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,158.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
| 2011-2
+
| 2017
| PRODUCED FLUID
+
| [[EOG RESOURCES INC]]
| style="text-align:right;" | 3334.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 396.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| STORAGE PENDING DISPOSAL OR REUSE
 
|  
 
|  
| REUSE OF BRINE TO FRAC A WELL
+
|-
 +
| 2017
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 440.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 +
|-
 +
| 2017
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 112.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 +
|-
 +
| 2017
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 804.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24063
 +
|-
 +
| 2017
 +
| [[EOG RESOURCES INC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 210.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-24462
 +
|-
 +
| 2018
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,325.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 +
|-
 +
| 2018
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 105.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
 
|-
 
|-
 +
| 2018
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 310.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24099
 
|-
 
|-
| 2012-1
+
| 2018
| PRODUCED FLUID
+
| [[SENECA RESOURCES CO LLC]]
| style="text-align:right;" | 592.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,232.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC003
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-23795
 
| 34-155-23795
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 120.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24079
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 180.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24099
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 350.00 Bbl
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| WMGR123NC039
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,510.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
| 2012-1
+
| 2019
| PRODUCED FLUID
+
| [[SENECA RESOURCES CO LLC]]
| style="text-align:right;" | 4115.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 430.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 275.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC003
 +
|-
 +
| 2019
 +
| [[SENECA RESOURCES CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 375.00 Bbl
 +
| REUSE (AT WELL PAD)
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 1822528
 +
| Primary Facility
 +
| 2009-08-13
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| The following items were noted during the inspection:
 +
|-
 +
| 1824533
 +
| Primary Facility
 +
| 2009-08-13
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Site inspected with OGI Bruce Jankura. There is no activity on site at this time.  Conductor pipe has been set.  All disturbed areas have been seeded and mulched with about 55% vegetation already grown back in.  Site has brush row reinforced with line of silt fence surrounding parameter.  All E&S control BMPs have been installed properly and are working adequately.  The pit is constructed and lined properly. Liner appears sound with no visible cuts or punctures.  More than 2ft of freeboard is being maintained.  Site Sign and E&S Plan are up the road from site.
 +
|-
 +
| 1833342
 +
| Primary Facility
 +
| 2009-09-30
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| Site inspected with OGI Supervisor, Bruce Jankura. Drilling was in progress.
 +
|-
 +
| 1834891
 +
| Primary Facility
 +
| 2009-09-30
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| The following items were noted during the inspection:
 +
|-
 +
| 1852735
 +
| Primary Facility
 +
| 2009-12-29
 +
| Routine/Complete Inspection
 +
| Violation(s) Noted
 +
| Conducted Inspection with WQS Jessica MIller and WQS Heather Agosta.
 +
|-
 +
| 1854541
 +
| Primary Facility
 +
| 2010-01-05
 +
| Compliance Evaluation
 +
| No Violations Noted
 +
| Drilling is completed and a digital meter is connected to well.
 +
|-
 +
| 1884382
 +
| Primary Facility
 +
| 2010-05-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Production well in line with digital meter.
 +
|-
 +
| 1954458
 +
| Primary Facility
 +
| 2011-03-02
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2707267
 +
| Primary Facility
 +
| 2018-03-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| The weather is 43 Deg. F and sunny at time of inspection. Routine inspection of Seneca Resources Corp., Punxsutawney Hunting Club Pad, Well # 7H on March 19, 2018. There is 1 producing well on this pad.
 +
Annular vent (7-5/8" x 4-1/2") is closed and not vented, plumed to the tank. Pressure gauge on the top of the xmas tree reads 128 PSI, casing pressure gauge reads 507 PSI. 0% combustible gas was detected at the annulus or in the area immediately surrounding the well. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized.
 +
Seneca Resources Corp. Representative ¿ Stephen ¿Gus¿ Simpson, Roustabout Foreman.
 +
DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.
 +
|-
 +
| 2851532
 +
| Primary Facility
 +
| 2019-02-21
 +
| Routine/Partial/Aerial Inspection
 +
| No Violations Noted
 +
| The weather is 34 Deg. F and sunny at time of inspection. Routine inspection of Seneca Resources Corp., D16-PHC-M Pad, Well # 7H on February 21, 2019. There is 1 active well on this pad.
 +
This well is open and producing at the time of inspection. Annular vent (7-5/8" x 4-1/2") is open and plumed to the tank. 0% combustible gas was detected in the area immediately surrounding the well. Production tubing pressure is 133 PSI, backside casing pressure 287 PSI. Production processing equipment on location includes 1 production water tank, 1 gas processing unit, measurement equipment ¿ orifice meter stations. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized.
 +
Seneca Resources Corp. Representative - Stephen Gus Simpson, Roustabout Foreman.
 +
DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 1852735
 +
| 578685
 +
| 12/29/2009
 +
| 2009-12-29
 +
| 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling
 +
| Administrative
 +
| See Insp ID 1854541 done 1/5/10, site permit sign posted, past viol closed.
 +
|-
 +
|}
 +
==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
| 578685
 +
| 254113
 +
| NOV - Notice of Violation
 +
| Comply/Closed
 
|  
 
|  
 +
| 2010-01-05
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 14:13, 14 May 2020

Well Details

Well ID: 37-033-26680
Loading map...
Country: United States
State: Pennsylvania
County: Clearfield
Municipality: Lawrence Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 147214
Farm/Lease Name: PUNXSUTAWNEY HUNTING CLUB 7H
License Status:
Spud Date:
Permit Date: 2008-07-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.170093
Longitude: -78.449767

For data sources see[1][2][3]

Well History

Date Event
2008-07-11 New Permit Application
2009-07-28 Permit Renewal Application
2009-08-05 Performed Spud Operation
2009-10-09 Drilling Completion
2009-10-20 Perforation
2010-11-16 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2008 EOG RESOURCES INC 0.00 0 0.00 0 0.00 0
2009 EOG RESOURCES INC 0.00 0 0.00 0 0.00 0
2010 EOG RESOURCES INC 278,652.19 225 0.00 0 0.00 0
2011 EOG RESOURCES INC 283,536.00 365 0.00 0 0.00 0
2012 EOG RESOURCES INC 228,877.00 366 0.00 0 0.00 0
2013 EOG RESOURCES INC 173,063.00 361 0.00 0 0.00 0
2014 EOG RESOURCES INC 154,287.97 360 0.00 0 0.00 0
2015 EOG RESOURCES INC 139,363.96 365 0.00 0 0.00 0
2016 EOG RESOURCES INC 115,821.23 309 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 99,933.64 311 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 109,619.68 359 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 120,471.52 344 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 EOG RESOURCES INC Produced Fluid 4,050.00 Bbl REUSE OTHER THAN ROAD SPREADING
2010 EOG RESOURCES INC Produced Fluid 8,350.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 EOG RESOURCES INC Produced Fluid 2,099.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0023213
2010 EOG RESOURCES INC Produced Fluid 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 EOG RESOURCES INC Produced Fluid 856.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011 EOG RESOURCES INC Produced Fluid 2,046.00 Bbl INJECTION DISPOSAL WELL 34-049-23127
2011 EOG RESOURCES INC Produced Fluid 6,051.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EOG RESOURCES INC Produced Fluid 108.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0023213
2011 EOG RESOURCES INC Produced Fluid 2,795.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 EOG RESOURCES INC Produced Fluid 389.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011 EOG RESOURCES INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2011 EOG RESOURCES INC Produced Fluid 604.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 EOG RESOURCES INC Produced Fluid 404.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2012 EOG RESOURCES INC Produced Fluid 4,288.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EOG RESOURCES INC Produced Fluid 190.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 EOG RESOURCES INC Produced Fluid 1,139.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 EOG RESOURCES INC Produced Fluid 190.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 EOG RESOURCES INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 EOG RESOURCES INC Produced Fluid 1,118.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EOG RESOURCES INC Produced Fluid 804.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 525-1
2012 EOG RESOURCES INC Produced Fluid 803.00 Bbl INJECTION DISPOSAL WELL 34-007-22038
2013 EOG RESOURCES INC Produced Fluid 94.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013 EOG RESOURCES INC Produced Fluid 592.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2013 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2013 EOG RESOURCES INC Produced Fluid 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EOG RESOURCES INC Produced Fluid 41.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2013 EOG RESOURCES INC Produced Fluid 204.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2013 EOG RESOURCES INC Produced Fluid 43.33 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2013 EOG RESOURCES INC Produced Fluid 43.33 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 EOG RESOURCES INC Produced Fluid 976.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EOG RESOURCES INC Produced Fluid 396.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 EOG RESOURCES INC Produced Fluid 515.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 EOG RESOURCES INC Produced Fluid 207.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2013 EOG RESOURCES INC Produced Fluid 43.33 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 EOG RESOURCES INC Produced Fluid 104.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2014 EOG RESOURCES INC Produced Fluid 399.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 EOG RESOURCES INC Produced Fluid 305.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2014 EOG RESOURCES INC Produced Fluid 633.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 EOG RESOURCES INC Produced Fluid 940.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 EOG RESOURCES INC Produced Fluid 440.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2014 EOG RESOURCES INC Produced Fluid 629.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014 EOG RESOURCES INC Produced Fluid 107.50 Bbl INJECTION DISPOSAL WELL 34-133-20525
2014 EOG RESOURCES INC Produced Fluid 315.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014 EOG RESOURCES INC Produced Fluid 310.00 Bbl INJECTION DISPOSAL WELL 34-155-24078
2014 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2014 EOG RESOURCES INC Produced Fluid 659.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014 EOG RESOURCES INC Produced Fluid 221.63 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 EOG RESOURCES INC Produced Fluid 190.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EOG RESOURCES INC Produced Fluid 221.63 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014 EOG RESOURCES INC Produced Fluid 221.63 Bbl INJECTION DISPOSAL WELL 34-155-21894
2015 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2015 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2015 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-24078
2015 EOG RESOURCES INC Produced Fluid 52.50 Bbl INJECTION DISPOSAL WELL 34-155-2-3794
2015 EOG RESOURCES INC Produced Fluid 476.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2015 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 EOG RESOURCES INC Produced Fluid 1,182.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2015 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2015 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2015 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2015 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2015 EOG RESOURCES INC Produced Fluid 2,101.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2016 EOG RESOURCES INC Produced Fluid 37.50 Bbl INJECTION DISPOSAL WELL 34-155-2-3794
2016 EOG RESOURCES INC Produced Fluid 105.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2016 EOG RESOURCES INC Produced Fluid 35.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2016 EOG RESOURCES INC Produced Fluid 37.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2016 EOG RESOURCES INC Produced Fluid 322.00 Bbl INJECTION DISPOSAL WELL 34-155-24063
2016 EOG RESOURCES INC Produced Fluid 2,601.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2016 EOG RESOURCES INC Produced Fluid 35.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2016 EOG RESOURCES INC Produced Fluid 35.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2017 SENECA RESOURCES CO LLC Produced Fluid 10.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2017 SENECA RESOURCES CO LLC Produced Fluid 1,158.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 EOG RESOURCES INC Produced Fluid 396.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 SENECA RESOURCES CO LLC Produced Fluid 440.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 112.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 EOG RESOURCES INC Produced Fluid 804.00 Bbl INJECTION DISPOSAL WELL 34-155-24063
2017 EOG RESOURCES INC Produced Fluid 210.00 Bbl INJECTION DISPOSAL WELL 34-133-24462
2018 SENECA RESOURCES CO LLC Produced Fluid 2,325.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 105.00 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 310.00 Bbl INJECTION DISPOSAL WELL 34-155-24099
2018 SENECA RESOURCES CO LLC Produced Fluid 1,232.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2019 SENECA RESOURCES CO LLC Produced Fluid 120.00 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 SENECA RESOURCES CO LLC Produced Fluid 180.00 Bbl INJECTION DISPOSAL WELL 34-155-24099
2019 SENECA RESOURCES CO LLC Produced Fluid 350.00 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 2,510.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 430.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2019 SENECA RESOURCES CO LLC Produced Fluid 275.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 375.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1822528 Primary Facility 2009-08-13 Drilling/Alteration No Violations Noted The following items were noted during the inspection:
1824533 Primary Facility 2009-08-13 Drilling/Alteration No Violations Noted Site inspected with OGI Bruce Jankura. There is no activity on site at this time. Conductor pipe has been set. All disturbed areas have been seeded and mulched with about 55% vegetation already grown back in. Site has brush row reinforced with line of silt fence surrounding parameter. All E&S control BMPs have been installed properly and are working adequately. The pit is constructed and lined properly. Liner appears sound with no visible cuts or punctures. More than 2ft of freeboard is being maintained. Site Sign and E&S Plan are up the road from site.
1833342 Primary Facility 2009-09-30 Drilling/Alteration No Violations Noted Site inspected with OGI Supervisor, Bruce Jankura. Drilling was in progress.
1834891 Primary Facility 2009-09-30 Drilling/Alteration No Violations Noted The following items were noted during the inspection:
1852735 Primary Facility 2009-12-29 Routine/Complete Inspection Violation(s) Noted Conducted Inspection with WQS Jessica MIller and WQS Heather Agosta.
1854541 Primary Facility 2010-01-05 Compliance Evaluation No Violations Noted Drilling is completed and a digital meter is connected to well.
1884382 Primary Facility 2010-05-12 Routine/Complete Inspection No Violations Noted Production well in line with digital meter.
1954458 Primary Facility 2011-03-02 Routine/Complete Inspection No Violations Noted
2707267 Primary Facility 2018-03-19 Routine/Complete Inspection No Violations Noted The weather is 43 Deg. F and sunny at time of inspection. Routine inspection of Seneca Resources Corp., Punxsutawney Hunting Club Pad, Well # 7H on March 19, 2018. There is 1 producing well on this pad.

Annular vent (7-5/8" x 4-1/2") is closed and not vented, plumed to the tank. Pressure gauge on the top of the xmas tree reads 128 PSI, casing pressure gauge reads 507 PSI. 0% combustible gas was detected at the annulus or in the area immediately surrounding the well. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. Seneca Resources Corp. Representative ¿ Stephen ¿Gus¿ Simpson, Roustabout Foreman. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2851532 Primary Facility 2019-02-21 Routine/Partial/Aerial Inspection No Violations Noted The weather is 34 Deg. F and sunny at time of inspection. Routine inspection of Seneca Resources Corp., D16-PHC-M Pad, Well # 7H on February 21, 2019. There is 1 active well on this pad.

This well is open and producing at the time of inspection. Annular vent (7-5/8" x 4-1/2") is open and plumed to the tank. 0% combustible gas was detected in the area immediately surrounding the well. Production tubing pressure is 133 PSI, backside casing pressure 287 PSI. Production processing equipment on location includes 1 production water tank, 1 gas processing unit, measurement equipment ¿ orifice meter stations. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. Seneca Resources Corp. Representative - Stephen Gus Simpson, Roustabout Foreman. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1852735 578685 12/29/2009 2009-12-29 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative See Insp ID 1854541 done 1/5/10, site permit sign posted, past viol closed.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
578685 254113 NOV - Notice of Violation Comply/Closed 2010-01-05

For data sources see[7]

References