If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(2 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-059-26438 | | Well ID: 37-059-26438 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 39.902792, -80.346328 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: LEWIS GH46EHS | | Farm/Lease Name: LEWIS GH46EHS | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
− | | Permit Date: | + | | Permit Date: 2014-03-07 |
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
| Latitude: 39.902792 | | Latitude: 39.902792 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2014-03-07 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2014-07-20 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2014-08-27 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2014-09-14 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2015-06-18 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2015-11-22 | ||
+ | | Performed Stimulation | ||
+ | |- | ||
+ | | 2016-01-29 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2016-04-28 | ||
+ | | DEVIATED | ||
+ | |- | ||
+ | | 2016-04-28 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
+ | == Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2015-11-22 | ||
+ | | 2015-12-01 | ||
+ | | style="text-align: right;" | 7,925 | ||
+ | | style="text-align: right;" | 8,169,660 | ||
+ | | style="text-align: right;" | 10,098 | ||
+ | |- | ||
+ | |} | ||
+ | ==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="38"| 1 | ||
+ | | rowspan="35"| | ||
+ | | rowspan="35"| | ||
+ | | rowspan="35"| Hazardous and Non-Hazardous Ingredients | ||
+ | | Olefins | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00009729 | ||
+ | | style="text-align: right;" | 76 | ||
+ | |- | ||
+ | | Ethyl alcohol | ||
+ | | 64-17-5 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000212494 | ||
+ | | style="text-align: right;" | 166 | ||
+ | |- | ||
+ | | Fatty acids, tall oil | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0231696 | ||
+ | | style="text-align: right;" | 181 | ||
+ | |- | ||
+ | | 2,7-Naphthalenedisulfonic acid,<br/> 5-(acetylamino) -4-hydroxy-3-[(2-methoxyphenyl)<br/> azo] -, disodium salt | ||
+ | | 6625-46-3 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | 0.00000256 | ||
+ | | style="text-align: right;" | 2 | ||
+ | |- | ||
+ | | Tributyl tetradecyl phosphonium chloride | ||
+ | | 81741-28-8 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00007681 | ||
+ | | style="text-align: right;" | 60 | ||
+ | |- | ||
+ | | Polyacrylate | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.047705 | ||
+ | | style="text-align: right;" | 37267 | ||
+ | |- | ||
+ | | Phosphoric acid | ||
+ | | 7664-38-2 | ||
+ | | style="text-align: right;" | 0.1 | ||
+ | | style="text-align: right;" | 0.00002176 | ||
+ | | style="text-align: right;" | 17 | ||
+ | |- | ||
+ | | Sobitan, mono-9-octadecenoate, (Z) | ||
+ | | 1338-43-8 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00541989 | ||
+ | | style="text-align: right;" | 4234 | ||
+ | |- | ||
+ | | Glutaraldehyde | ||
+ | | 111-30-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.00636715 | ||
+ | | style="text-align: right;" | 4974 | ||
+ | |- | ||
+ | | Fatty acid ester | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00541989 | ||
+ | | style="text-align: right;" | 4234 | ||
+ | |- | ||
+ | | Food red 10 | ||
+ | | 3734-67-6 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | 0.00000256 | ||
+ | | style="text-align: right;" | 2 | ||
+ | |- | ||
+ | | Polyacrylate | ||
+ | | Proprietary | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0325193 | ||
+ | | style="text-align: right;" | 25404 | ||
+ | |- | ||
+ | | Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.278689 | ||
+ | | style="text-align: right;" | 217711 | ||
+ | |- | ||
+ | | Telomer | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.0023784 | ||
+ | | style="text-align: right;" | 1858 | ||
+ | |- | ||
+ | | 2,7-Naphthalenedisulfonic acid,<br/> 3-hydroxy-4-[(4-sulfor-1-naphthalenyl)<br/> azo] -, trisodium salt | ||
+ | | 915-67-3 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | 0.00000256 | ||
+ | | style="text-align: right;" | 2 | ||
+ | |- | ||
+ | | Crystalline silica, quartz | ||
+ | | 14808-60-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 13.8642 | ||
+ | | style="text-align: right;" | 10,830,700.0 | ||
+ | |- | ||
+ | | Sodium polyacrylate | ||
+ | | 9003-04-7 | ||
+ | | style="text-align: right;" | 1 | ||
+ | | style="text-align: right;" | 0.000238096 | ||
+ | | style="text-align: right;" | 186 | ||
+ | |- | ||
+ | | Hydrotreated light petroleum distillate | ||
+ | | 64742-47-8 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0650387 | ||
+ | | style="text-align: right;" | 50808 | ||
+ | |- | ||
+ | | Hydrochloric acid | ||
+ | | 7647-01-0 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.0717412 | ||
+ | | style="text-align: right;" | 56044 | ||
+ | |- | ||
+ | | Sodium chloride | ||
+ | | 7647-14-5 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00541989 | ||
+ | | style="text-align: right;" | 4234 | ||
+ | |- | ||
+ | | Methanol | ||
+ | | 67-56-1 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.000462111 | ||
+ | | style="text-align: right;" | 361 | ||
+ | |- | ||
+ | | Ammonium chloride | ||
+ | | 12125-02-9 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.0162597 | ||
+ | | style="text-align: right;" | 12702 | ||
+ | |- | ||
+ | | Acrylic acid | ||
+ | | 79-10-7 | ||
+ | | style="text-align: right;" | 0.01 | ||
+ | | style="text-align: right;" | 0.00000256 | ||
+ | | style="text-align: right;" | 2 | ||
+ | |- | ||
+ | | Reaction product of acetophenone,<br/> formaldehyde, thiourea<br/> and oleic acid in dimethyl formamide | ||
+ | | 68527-49-1 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.000231696 | ||
+ | | style="text-align: right;" | 181 | ||
+ | |- | ||
+ | | Alcohols, C14-C15, ethoxylated | ||
+ | | 68951-67-7 | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0231696 | ||
+ | | style="text-align: right;" | 181 | ||
+ | |- | ||
+ | | Sodium sulfate | ||
+ | | 7757-82-6 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00126601 | ||
+ | | style="text-align: right;" | 989 | ||
+ | |- | ||
+ | | Ethylene glycol | ||
+ | | 107-21-1 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.014273 | ||
+ | | style="text-align: right;" | 11150 | ||
+ | |- | ||
+ | | Alcohols, C12-16, ethoxylated | ||
+ | | 68551-12-2 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.0108398 | ||
+ | | style="text-align: right;" | 8468 | ||
+ | |- | ||
+ | | Acetic acid | ||
+ | | 64-19-7 | ||
+ | | style="text-align: right;" | 60 | ||
+ | | style="text-align: right;" | 0.00557478 | ||
+ | | style="text-align: right;" | 4355 | ||
+ | |- | ||
+ | | Castor oil, ethoxylated | ||
+ | | 61791-12-6 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00541989 | ||
+ | | style="text-align: right;" | 4234 | ||
+ | |- | ||
+ | | Alkyl (C12-16) dimethylbenzylammonium chloride | ||
+ | | 68424-85-1 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.00106119 | ||
+ | | style="text-align: right;" | 829 | ||
+ | |- | ||
+ | | 9-Octadecenamide, n,n-bis-2(hydroxy-ethyl)-,(Z) | ||
+ | | 93-83-4 | ||
+ | | style="text-align: right;" | 5 | ||
+ | | style="text-align: right;" | 0.0108398 | ||
+ | | style="text-align: right;" | 8468 | ||
+ | |- | ||
+ | | Inorganic salt | ||
+ | | Confidential | ||
+ | | style="text-align: right;" | 30 | ||
+ | | style="text-align: right;" | 0.0325193 | ||
+ | | style="text-align: right;" | 25404 | ||
+ | |- | ||
+ | | Acetic anhydride | ||
+ | | 108-24-7 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 0.00929087 | ||
+ | | style="text-align: right;" | 7258 | ||
+ | |- | ||
+ | | Propargyl alcohol | ||
+ | | 107-19-7 | ||
+ | | style="text-align: right;" | 10 | ||
+ | | style="text-align: right;" | 0.00007809 | ||
+ | | style="text-align: right;" | 61 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| BE-9, FDP-M1075-12, FDP-S1176-15,<br/> FE-1A ACIDIZING COMPOSITION,<br/> HAI-OS ACID INHIBITOR,<br/> MC B-8614, PermVis VFR-10,<br/> SAND-COMMON WHITE-100<br/> MESH, SSA-2, SAND-PREMIUM WHITE-40/70, SCALECHEK LP-55 SCALE INHIBITOR | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Additive, Biocide, Corrosion Inhibitor, Friction Reducer, Proppant, Scale Inhibitor | ||
+ | | NA | ||
+ | | NA | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| HYDROCHLORIC ACID | ||
+ | | rowspan="1"| Halliburton | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | NA | ||
+ | | NA | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |- valign="top" | ||
+ | | rowspan="1"| Fresh Water | ||
+ | | rowspan="1"| Operator | ||
+ | | rowspan="1"| Base Fluid | ||
+ | | Fresh Water | ||
+ | | 7732-18-5 | ||
+ | | style="text-align: right;" | 100 | ||
+ | | style="text-align: right;" | 85.8505 | ||
+ | | style="text-align: right;" | 67,066,100.0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title =FracFocus Fracking Chemicals Database | ||
+ | | date = 2019-04-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-06-19 }}</ref> | ||
+ | == Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | | 2015-11-22 | ||
+ | | style="text-align: right;" | | ||
+ | |||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Completion Reports - Stimulations | ||
+ | | publisher = Pennsylvania Department of Conservation and Natural Resources | ||
+ | | date = 2020-03-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-03-02 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 107: | Line 453: | ||
| 2019 | | 2019 | ||
| [[CNX GAS CO LLC]] | | [[CNX GAS CO LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 835,242.52 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 365 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 124: | Line 470: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 129: | Line 476: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Drill Cuttings |
− | | | + | | style="text-align: right;" | 68.40 Tons |
− | | | + | | LANDFILL |
+ | | PAD059087072 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Drill Cuttings |
− | | | + | | style="text-align: right;" | 401.53 Tons |
− | | | + | | LANDFILL |
+ | | 100172 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Drilling Fluid Waste |
− | | | + | | style="text-align: right;" | 788.75 Bbl |
− | | | + | | LANDFILL |
+ | | PAD059087072 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Drilling Fluid Waste | |
− | + | | style="text-align: right;" | 1,288.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | 1, | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2014 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Drill Cuttings | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | | Drill Cuttings | ||
| style="text-align: right;" | 209.51 Tons | | style="text-align: right;" | 209.51 Tons | ||
| LANDFILL | | LANDFILL | ||
| 06-08438 | | 06-08438 | ||
|- | |- | ||
− | | 2014 | + | | 2014 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Drilling Fluid Waste | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Drilling Fluid Waste | ||
| style="text-align: right;" | 83.74 Bbl | | style="text-align: right;" | 83.74 Bbl | ||
| LANDFILL | | LANDFILL | ||
| 06-08438 | | 06-08438 | ||
|- | |- | ||
− | | | + | | 2015 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Fracing Fluid Waste | |
− | + | | style="text-align: right;" | 128.84 Bbl | |
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | Drill Cuttings | + | | [[CNX GAS CO LLC]] |
+ | | Drill Cuttings | ||
| style="text-align: right;" | 101.44 Tons | | style="text-align: right;" | 101.44 Tons | ||
| LANDFILL | | LANDFILL | ||
| PAD059087072 | | PAD059087072 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | Drilling Fluid Waste | + | | [[CNX GAS CO LLC]] |
+ | | Drilling Fluid Waste | ||
| style="text-align: right;" | 60.55 Bbl | | style="text-align: right;" | 60.55 Bbl | ||
| LANDFILL | | LANDFILL | ||
| PAD059087072 | | PAD059087072 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | Drilling Fluid Waste | + | | [[CNX GAS CO LLC]] |
+ | | Drilling Fluid Waste | ||
| style="text-align: right;" | 218.80 Bbl | | style="text-align: right;" | 218.80 Bbl | ||
| RESIDUAL WASTE TRANSFER FACILITY | | RESIDUAL WASTE TRANSFER FACILITY | ||
| 301071 | | 301071 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Fracturing Fluid Waste |
+ | | style="text-align: right;" | 8,995.07 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 22,950.29 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 137.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
+ | | 34-119-28780 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 879.16 Bbl | | style="text-align: right;" | 879.16 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 1,057.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28803 | | 34-119-28803 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | | | + | | style="text-align: right;" | 627.00 Bbl |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-013-20609 | | 34-013-20609 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 29.81 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28780 | | 34-119-28780 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 47.41 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28803 | | 34-119-28803 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 1,450.68 Bbl |
− | | | + | | SURFACE IMPOUNDMENT |
+ | | 95-7-37312-21 | ||
|- | |- | ||
− | | | + | | 2017 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 18.29 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-157-25511 |
|- | |- | ||
− | | | + | | 2017 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | | | + | | style="text-align: right;" | 1,636.58 Bbl |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | 1, | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 4,502.92 Bbl | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-10 | | 95-7-37312-10 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | + | | [[CNX GAS CO LLC]] | |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 1,645.90 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-19 | | 95-7-37312-19 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 2,147.73 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-17 | | 95-7-37312-17 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | + | | [[CNX GAS CO LLC]] | |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 354.47 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-16 | | 95-7-37312-16 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 73.33 Bbl | |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
− | | 95-7-37312- | + | | 95-7-37312-32 |
|- | |- | ||
− | | | + | | 2018 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 770.75 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-21 | | 95-7-37312-21 | ||
|- | |- | ||
− | | | + | | 2018 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 7.08 Bbl | |
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-013-20609 |
|- | |- | ||
− | | | + | | 2018 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 1,673.68 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28803 | | 34-119-28803 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 9.17 Bbl |
− | | | + | | CENT WASTE TRT FAC NPDES |
+ | | PA0095273 | ||
|- | |- | ||
− | | | + | | 2018 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 106.82 Bbl | |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | | REUSE | ||
| | | | ||
|- | |- | ||
− | | | + | | 2018 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 632.18 Bbl | |
− | |||
− | | | ||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | 18 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-17 | | 95-7-37312-17 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
+ | | Produced Fluid | ||
| style="text-align: right;" | 9.17 Bbl | | style="text-align: right;" | 9.17 Bbl | ||
− | | | + | | CENT WASTE TRT FAC NPDES DISCHARGE |
− | | | + | | PA0095273 |
|- | |- | ||
− | | | + | | 2018 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 6,325.11 Bbl | |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-19 | | 95-7-37312-19 | ||
|- | |- | ||
− | + | | 2018 | |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 130.80 Bbl | |
− | |||
− | |||
− | | 2018 | ||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28780 | | 34-119-28780 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 131.08 Bbl | | style="text-align: right;" | 131.08 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-157-25511 | | 34-157-25511 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 1,073.35 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 299.57 Bbl | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
− | | 95-7-37312- | + | | 95-7-37312-21 |
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 21.03 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28780 | | 34-119-28780 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 0.83 Bbl | |
− | | | + | | RESIDUAL WASTE PROCESSING FACILITY |
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | | | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Other Oil & Gas Wastes | |
− | + | | style="text-align: right;" | 0.21 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-21 | | 95-7-37312-21 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 1,953.31 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-19 | | 95-7-37312-19 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 240.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-17 | | 95-7-37312-17 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 315.43 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | | + | | Other Oil & Gas Wastes |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| style="text-align: right;" | 9.17 Bbl | | style="text-align: right;" | 9.17 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 7.76 Bbl | | style="text-align: right;" | 7.76 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-119-28803 | | 34-119-28803 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[CNX GAS CO LLC]] |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 18.33 Bbl | | style="text-align: right;" | 18.33 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Other Oil & Gas Wastes | |
− | | | + | | style="text-align: right;" | 27.50 Bbl |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | | ||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 1.83 Bbl | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-17 | | 95-7-37312-17 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 63.34 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
+ | | 34-157-25511 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | Other Oil & Gas Wastes | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 9.17 Bbl | ||
| SURFACE IMPOUNDMENT | | SURFACE IMPOUNDMENT | ||
| 95-7-37312-19 | | 95-7-37312-19 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | + | | [[CNX GAS CO LLC]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 38.62 Bbl | |
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW019 |
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | Produced Fluid | + | | [[CNX GAS CO LLC]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | REUSE | + | | style="text-align: right;" | 1,928.25 Bbl |
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
Line 1,144: | Line 866: | ||
| 2298838 | | 2298838 | ||
| Primary Facility | | Primary Facility | ||
− | | 07 | + | | 2014-07-14 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,151: | Line 873: | ||
| 2308643 | | 2308643 | ||
| Primary Facility | | Primary Facility | ||
− | | 09 | + | | 2014-09-19 |
| Drilling/Alteration | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,158: | Line 880: | ||
| 2356122 | | 2356122 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-25 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,165: | Line 887: | ||
| 2358862 | | 2358862 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-04 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,172: | Line 894: | ||
| 2363529 | | 2363529 | ||
| Primary Facility | | Primary Facility | ||
− | | 03 | + | | 2015-03-10 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,179: | Line 901: | ||
| 2387262 | | 2387262 | ||
| Primary Facility | | Primary Facility | ||
− | | 04 | + | | 2015-04-22 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,186: | Line 908: | ||
| 2411141 | | 2411141 | ||
| Primary Facility | | Primary Facility | ||
− | | 08 | + | | 2015-08-12 |
| Routine/Complete Inspection | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,193: | Line 915: | ||
| 2450885 | | 2450885 | ||
| Primary Facility | | Primary Facility | ||
− | | 12 | + | | 2015-12-29 |
| Incident- Response to Accident or Event | | Incident- Response to Accident or Event | ||
| No Violations Noted | | No Violations Noted | ||
Line 1,283: | Line 1,005: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==References== | ==References== | ||
<references/> | <references/> |
Well ID: 37-059-26438 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.902792,"lon":-80.346328,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Center Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 150845 | |
Farm/Lease Name: LEWIS GH46EHS | |
License Status: | |
Spud Date: | |
Permit Date: 2014-03-07 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 39.902792 | |
Longitude: -80.346328 |
Date | Event |
---|---|
2014-03-07 | New Permit Application |
2014-07-20 | Performed Spud Operation |
2014-08-27 | New Permit Application |
2014-09-14 | Drilling Completion |
2015-06-18 | Perforation |
2015-11-22 | Performed Stimulation |
2016-01-29 | Drilling Completion |
2016-04-28 | DEVIATED |
2016-04-28 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-11-22 | 2015-12-01 | 7,925 | 8,169,660 | 10,098 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Hazardous and Non-Hazardous Ingredients | Olefins | Confidential | 5 | 0.00009729 | 76 | ||
Ethyl alcohol | 64-17-5 | 1 | 0.000212494 | 166 | ||||
Fatty acids, tall oil | Confidential | 30 | 0.0231696 | 181 | ||||
2,7-Naphthalenedisulfonic acid, 5-(acetylamino) -4-hydroxy-3-[(2-methoxyphenyl) azo] -, disodium salt |
6625-46-3 | 0.01 | 0.00000256 | 2 | ||||
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00007681 | 60 | ||||
Polyacrylate | Confidential | 60 | 0.047705 | 37267 | ||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002176 | 17 | ||||
Sobitan, mono-9-octadecenoate, (Z) | 1338-43-8 | 5 | 0.00541989 | 4234 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00636715 | 4974 | ||||
Fatty acid ester | Confidential | 5 | 0.00541989 | 4234 | ||||
Food red 10 | 3734-67-6 | 0.01 | 0.00000256 | 2 | ||||
Polyacrylate | Proprietary | 30 | 0.0325193 | 25404 | ||||
Water | 7732-18-5 | 100 | 0.278689 | 217711 | ||||
Telomer | Confidential | 10 | 0.0023784 | 1858 | ||||
2,7-Naphthalenedisulfonic acid, 3-hydroxy-4-[(4-sulfor-1-naphthalenyl) azo] -, trisodium salt |
915-67-3 | 0.01 | 0.00000256 | 2 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 13.8642 | 10,830,700.0 | ||||
Sodium polyacrylate | 9003-04-7 | 1 | 0.000238096 | 186 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0650387 | 50808 | ||||
Hydrochloric acid | 7647-01-0 | 60 | 0.0717412 | 56044 | ||||
Sodium chloride | 7647-14-5 | 5 | 0.00541989 | 4234 | ||||
Methanol | 67-56-1 | 60 | 0.000462111 | 361 | ||||
Ammonium chloride | 12125-02-9 | 10 | 0.0162597 | 12702 | ||||
Acrylic acid | 79-10-7 | 0.01 | 0.00000256 | 2 | ||||
Reaction product of acetophenone, formaldehyde, thiourea and oleic acid in dimethyl formamide |
68527-49-1 | 30 | 0.000231696 | 181 | ||||
Alcohols, C14-C15, ethoxylated | 68951-67-7 | 30 | 0.0231696 | 181 | ||||
Sodium sulfate | 7757-82-6 | 5 | 0.00126601 | 989 | ||||
Ethylene glycol | 107-21-1 | 60 | 0.014273 | 11150 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 10 | 0.0108398 | 8468 | ||||
Acetic acid | 64-19-7 | 60 | 0.00557478 | 4355 | ||||
Castor oil, ethoxylated | 61791-12-6 | 5 | 0.00541989 | 4234 | ||||
Alkyl (C12-16) dimethylbenzylammonium chloride | 68424-85-1 | 5 | 0.00106119 | 829 | ||||
9-Octadecenamide, n,n-bis-2(hydroxy-ethyl)-,(Z) | 93-83-4 | 5 | 0.0108398 | 8468 | ||||
Inorganic salt | Confidential | 30 | 0.0325193 | 25404 | ||||
Acetic anhydride | 108-24-7 | 100 | 0.00929087 | 7258 | ||||
Propargyl alcohol | 107-19-7 | 10 | 0.00007809 | 61 | ||||
BE-9, FDP-M1075-12, FDP-S1176-15, FE-1A ACIDIZING COMPOSITION, HAI-OS ACID INHIBITOR, MC B-8614, PermVis VFR-10, SAND-COMMON WHITE-100 MESH, SSA-2, SAND-PREMIUM WHITE-40/70, SCALECHEK LP-55 SCALE INHIBITOR |
Halliburton | Additive, Biocide, Corrosion Inhibitor, Friction Reducer, Proppant, Scale Inhibitor | NA | NA | 0 | 0 | 0 | |
HYDROCHLORIC ACID | Halliburton | Base Fluid | NA | NA | 0 | 0 | 0 | |
Fresh Water | Operator | Base Fluid | Fresh Water | 7732-18-5 | 100 | 85.8505 | 67,066,100.0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-11-22 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 2,768,988.39 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CNX GAS CO LLC | 1,715,118.10 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 1,110,691.39 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 835,242.52 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CNX GAS CO LLC | Drill Cuttings | 68.40 Tons | LANDFILL | PAD059087072 |
2014 | CNX GAS CO LLC | Drill Cuttings | 401.53 Tons | LANDFILL | 100172 |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 788.75 Bbl | LANDFILL | PAD059087072 |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 1,288.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CNX GAS CO LLC | Drill Cuttings | 209.51 Tons | LANDFILL | 06-08438 |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 83.74 Bbl | LANDFILL | 06-08438 |
2015 | CNX GAS CO LLC | Fracing Fluid Waste | 128.84 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CNX GAS CO LLC | Drill Cuttings | 101.44 Tons | LANDFILL | PAD059087072 |
2015 | CNX GAS CO LLC | Drilling Fluid Waste | 60.55 Bbl | LANDFILL | PAD059087072 |
2015 | CNX GAS CO LLC | Drilling Fluid Waste | 218.80 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 301071 |
2016 | CNX GAS CO LLC | Fracturing Fluid Waste | 8,995.07 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 22,950.29 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 137.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2016 | CNX GAS CO LLC | Produced Fluid | 879.16 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2016 | CNX GAS CO LLC | Produced Fluid | 1,057.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2016 | CNX GAS CO LLC | Produced Fluid | 627.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 29.81 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2017 | CNX GAS CO LLC | Produced Fluid | 47.41 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,450.68 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017 | CNX GAS CO LLC | Produced Fluid | 18.29 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,636.58 Bbl | REUSE (AT WELL PAD) | |
2017 | CNX GAS CO LLC | Produced Fluid | 4,502.92 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,645.90 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017 | CNX GAS CO LLC | Produced Fluid | 2,147.73 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017 | CNX GAS CO LLC | Produced Fluid | 354.47 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-16 |
2017 | CNX GAS CO LLC | Produced Fluid | 73.33 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-32 |
2018 | CNX GAS CO LLC | Produced Fluid | 770.75 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Produced Fluid | 7.08 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,673.68 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | CNX GAS CO LLC | Produced Fluid | 9.17 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2018 | CNX GAS CO LLC | Produced Fluid | 106.82 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CNX GAS CO LLC | Produced Fluid | 632.18 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 9.17 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2018 | CNX GAS CO LLC | Produced Fluid | 6,325.11 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 130.80 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2018 | CNX GAS CO LLC | Produced Fluid | 131.08 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,073.35 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 299.57 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 21.03 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2019 | CNX GAS CO LLC | Produced Fluid | 0.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 0.21 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 1,953.31 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 240.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Produced Fluid | 315.43 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 9.17 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 7.76 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | CNX GAS CO LLC | Produced Fluid | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 27.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 1.83 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Produced Fluid | 63.34 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 9.17 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 38.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Produced Fluid | 1,928.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2298838 | Primary Facility | 2014-07-14 | Routine/Complete Inspection | No Violations Noted | Well not drilled, pre-spud inspection. |
2308643 | Primary Facility | 2014-09-19 | Drilling/Alteration | No Violations Noted | DRILLING OF TOP HOLE SETES COMPLETE. CEMENT DETAILS REVIEWED. WELL DRILLED TO KOP AT 7018'. |
2356122 | Primary Facility | 2015-03-25 | Routine/Complete Inspection | No Violations Noted | |
2358862 | Primary Facility | 2015-03-04 | Routine/Complete Inspection | No Violations Noted | Well drilled to TD. Well waiting to be fracked. |
2363529 | Primary Facility | 2015-03-10 | Routine/Complete Inspection | No Violations Noted | The well has been drilled to TD, and is waiting to be fracked. |
2387262 | Primary Facility | 2015-04-22 | Routine/Complete Inspection | No Violations Noted | Well drilled to TD. Well waiting for to be fractured. |
2411141 | Primary Facility | 2015-08-12 | Routine/Complete Inspection | No Violations Noted | The well is drilled to TD. Well awaiting hydraulic fracturing operations to recommence. |
2450885 | Primary Facility | 2015-12-29 | Incident- Response to Accident or Event | No Violations Noted | On 12/29/15, I performed an incident response inspection at GH46 site in response to an operator reported spill and made the following observations: |
2474696 | Primary Facility | 2016-04-13 | Compliance Evaluation | No Violations Noted | On 4/13/16, I performed a compliance evaluation inspection at the GH46 in relation to a spill from 12/29/15 and made the following observations:
•All required documents and signage were in place at the site. •Multiple bare areas of soil as well as areas of patchy or sparse vegetation were noted but did not appear to be related to the spill. No violation. •All 12 permitted wells were present and active at the time of inspection. No violation. •Many barrels of desiccant were found on site with no containment. No violation, containment is recommended. •Standing water in the vicinity of the related spill tested at 851¿s. No violation. Conclusion: •Initial remediation efforts detailed in the 15 day response appear to have been effective, a site characterization report is still required within 180 days of the spill date and further remediation may be required. |
2487460 | Primary Facility | 2016-05-10 | Routine/Complete Inspection | No Violations Noted | Well drilled to TD and completed. Well in flow back/ production operations. |
2489021 | Primary Facility | 2016-05-20 | Incident- Response to Accident or Event | In Compliance with Policy | On Thursday, May 19, 2016, a brine spill had occurred at the GH 46 Well Site located in Center Township, Greene County. The release occurred at an above ground storage tank (AST) that is connected to a series of salt dryers. A hose placed through a port at the top of the AST, to off-load material, continued to syphon brine from the tank when the hose was disconnected from the truck. It was estimated that approximately 60-70 barrels of brine was syphoned from the AST and into containment surrounding the tank. The containment was vacuumed out with a truck and the contents were placed back into the AST.
The release was completely contained and there was no impact to water or the ground surface. The incident has been determined to be In Compliance with Policy (ICP). No violations are being cited at this time. |
2493662 | Primary Facility | 2016-06-03 | Incident- Response to Accident or Event | In Compliance with Policy | On Friday, June 3, 2016, I was notified of a spill that had occurred at the GH 46 Well Site located in Center Township, Greene County. Salt from the drying units is placed into 55-gallon drums after reaching its effective capacity. The drums are staged on-site inside of secondary containment prior to off-site disposal. Rain water from multiple precipitation events had mixed with salt residue on the drums. The salt went back into solution and into the containment structure. Given the amount of precipitation at the time, the fluid inside containment overflowed the berm and stained the gravel. The stained gravel was scraped from the pad and disposed off-site. Soil conductivity readings were taken to determine the extent of excavation and confirmation samples were collected for analysis following the excavation. CNX Gas Company has since made arrangements to have the drums removed from the site and staged with their environmental contractor at a facility prior to disposal.
There was no impact to Waters of |
2493814 | Primary Facility | 2016-06-03 | Incident- Response to Accident or Event | In Compliance with Policy | A mist from a blowdown tank was released through a valve which impacted the well pad. It was estimated that approximately three gallons of product was inadvertently released through the valve which impacted an area of the well pad approximately 40 feet by 40 feet. The impacted gravel was scraped from the surface of the well pad for off-site disposal. |
2573116 | Primary Facility | 2017-03-20 | Routine/Complete Inspection | No Violations Noted | On Monday, March 20, 2017, I conducted a routine complete inspection of the GH-46 Gas Well Site located in Center Township, Greene County.
The Act 9 sign was clearly legible at the site entrance along Jacobs Run Road. A sign depicting gas well API numbers was also clearly posted at the site entrance and all required documentation was available on-site. The access road and the well pad were in good condition. The operator should continue their periodic monitoring program and perform all necessary maintenance to the access road and well pad upon identification. General site construction and PCSM controls were inspected and confirmed to have been completed according to the permitted site plans. The site is completely vegetated. Both filter sock and silt fence were observed in place in several areas surrounding the site and along the access road. The Filter sock and silt fence were also observed to require maintenance. The operator should evaluate site vegetation and whether the filter sock and silt fen |
For data sources see[9]