If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
(One intermediate revision by the same user not shown) | |||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-125-27505 | | Well ID: 37-125-27505 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.178758, -79.976114 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: HAYWOOD 592444 | | Farm/Lease Name: HAYWOOD 592444 | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2014-10-28 | | Permit Date: 2014-10-28 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
| Latitude: 40.178758 | | Latitude: 40.178758 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2014-10-28 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2014-12-17 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2015-06-30 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2015-09-04 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2015-09-06 | ||
+ | | Performed Stimulation | ||
+ | |- | ||
+ | | 2016-04-15 | ||
+ | | DEVIATED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 95: | ||
| 2015-09-06 | | 2015-09-06 | ||
| 2015-09-17 | | 2015-09-17 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 7,742 |
− | | style="text-align: right;" | 7,590,070 | + | | style="text-align: right;" | 7,590,070 |
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
|- | |- | ||
Line 198: | Line 231: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | == Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | | 2015-09-06 | ||
+ | | style="text-align: right;" | | ||
+ | |||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | | style="text-align: right;" | 0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Completion Reports - Stimulations | ||
+ | | publisher = Pennsylvania Department of Conservation and Natural Resources | ||
+ | | date = 2020-03-02 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-03-02 }}</ref> | ||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 256: | Line 312: | ||
| 2019 | | 2019 | ||
| [[EQT PROD CO]] | | [[EQT PROD CO]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 485,586.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 308 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 273: | Line 329: | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
!scope="col" | Period | !scope="col" | Period | ||
+ | !scope="col" | Operator | ||
!scope="col" | Waste Type | !scope="col" | Waste Type | ||
!scope="col" | Quantity | !scope="col" | Quantity | ||
Line 278: | Line 335: | ||
!scope="col" | Waste Facility ID | !scope="col" | Waste Facility ID | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Drilling Fluid Waste |
− | | | + | | style="text-align: right;" | 1,210.00 Bbl |
− | | | + | | REUSE OTHER THAN ROAD SPREADING |
+ | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Fracturing Fluid Waste |
+ | | style="text-align: right;" | 34.43 Tons | ||
| LANDFILL | | LANDFILL | ||
− | | | + | | 101571 |
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | Drill Cuttings | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Drill Cuttings |
+ | | style="text-align: right;" | 888.91 Tons | ||
| LANDFILL | | LANDFILL | ||
| 100663 | | 100663 | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Fracing Fluid Waste | |
− | |||
− | |||
− | |||
− | |||
− | | Fracing Fluid Waste | ||
| style="text-align: right;" | 294.00 Bbl | | style="text-align: right;" | 294.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | 2015 | + | | 2015 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Drill Cuttings |
+ | | style="text-align: right;" | 397.00 Tons | ||
| LANDFILL | | LANDFILL | ||
− | | | + | | 100172 |
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | Produced Fluid | + | | [[EQT PROD CO]] |
+ | | Produced Fluid | ||
| style="text-align: right;" | 430.00 Bbl | | style="text-align: right;" | 430.00 Bbl | ||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2016 | + | | 2016 |
− | | Produced Fluid | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 6,148.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2017 |
− | + | | [[EQT PROD CO]] | |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 351.18 Bbl | |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Other Oil & Gas Wastes | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Other Oil & Gas Wastes | ||
| style="text-align: right;" | 390.00 Bbl | | style="text-align: right;" | 390.00 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 2.37 Bbl | | style="text-align: right;" | 2.37 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-031-27177 | | 34-031-27177 | ||
|- | |- | ||
− | | 2017 | + | | 2017 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 3,273.69 Bbl | |
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | + | | [[EQT PROD CO]] | |
− | | | + | | Produced Fluid |
− | + | | style="text-align: right;" | 46.11 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 40.87 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | Produced Fluid | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 3.34 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
+ | | 34-157-25511 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | Other Oil & Gas Wastes | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | 6. | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 6.67 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 5.90 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW019 |
|- | |- | ||
− | | 2018 | + | | 2018 |
− | + | | [[EQT PROD CO]] | |
− | | | + | | Other Oil & Gas Wastes |
− | + | | style="text-align: right;" | 0.95 Bbl | |
− | |||
− | |||
− | |||
− | | | ||
− | | style="text-align: right;" | 0. | ||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | Other Oil & Gas Wastes | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | 2. | + | | Other Oil & Gas Wastes |
− | | | + | | style="text-align: right;" | 2.38 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
+ | | ORDER 2016-415 | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | + | | [[EQT PROD CO]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 9.83 Bbl | |
− | + | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
− | | | ||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
− | | REUSE | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | + | | [[EQT PROD CO]] | |
− | + | | Other Oil & Gas Wastes | |
− | | | + | | style="text-align: right;" | 33.71 Bbl |
− | |||
− | |||
− | |||
− | | Other Oil & Gas Wastes | ||
− | | style="text-align: right;" | | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2018 | + | | 2018 |
− | | Produced Fluid | + | | [[EQT PROD CO]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 304.93 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | | style="text-align: right;" | | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 23.23 Bbl |
− | | | + | | SURFACE IMPOUNDMENT |
+ | | 95-7-37312-19 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[EQT PROD CO]] | |
− | + | | Other Oil & Gas Wastes | |
− | | | + | | style="text-align: right;" | 4.57 Bbl |
− | |||
− | |||
− | |||
− | | Other Oil & Gas Wastes | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align: right;" | | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | | + | | 2D0859721 |
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 40.71 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | | | + | | 2019 |
− | | Produced Fluid | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | REUSE | + | | style="text-align: right;" | 63.78 Bbl |
+ | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 19.95 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34- | + | | 34-167-29543 |
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Other Oil & Gas Wastes |
+ | | style="text-align: right;" | 165.00 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[EQT PROD CO]] | |
− | + | | Other Oil & Gas Wastes | |
− | + | | style="text-align: right;" | 5.24 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | | Other Oil & Gas Wastes | ||
− | | style="text-align: right;" | 5. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
| | | | ||
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
+ | | style="text-align: right;" | 5.09 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW019 |
|- | |- | ||
− | | | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 816.53 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
+ | | 2D0859721 | ||
|- | |- | ||
− | | | + | | 2019 |
− | + | | [[EQT PROD CO]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 37.86 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
| WMGR123SW005 | | WMGR123SW005 | ||
|- | |- | ||
− | + | | 2019 | |
− | + | | [[EQT PROD CO]] | |
− | + | | Other Oil & Gas Wastes | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | 2019 | ||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Other Oil & Gas Wastes | ||
| style="text-align: right;" | 57.14 Bbl | | style="text-align: right;" | 57.14 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-105-23619 | | 34-105-23619 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | Other Oil & Gas Wastes | + | | [[EQT PROD CO]] |
+ | | Other Oil & Gas Wastes | ||
| style="text-align: right;" | 10.48 Bbl | | style="text-align: right;" | 10.48 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-167-29543 | | 34-167-29543 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | | + | | style="text-align: right;" | 1.67 Bbl |
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
| | | | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | | style="text-align: right;" | | + | | Produced Fluid |
− | | REUSE AT | + | | style="text-align: right;" | 451.87 Bbl |
+ | | REUSE (AT WELL PAD) | ||
| | | | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | | | + | | [[EQT PROD CO]] |
− | + | | Produced Fluid | |
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
| style="text-align: right;" | 208.21 Bbl | | style="text-align: right;" | 208.21 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| 34-105-23619 | | 34-105-23619 | ||
|- | |- | ||
− | | 2019 | + | | 2019 |
− | + | | [[EQT PROD CO]] | |
− | + | | Produced Fluid | |
− | + | | style="text-align: right;" | 137.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | Produced Fluid | ||
− | | style="text-align: right;" | | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
− | | | + | | WMGR123SW010 |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
Line 820: | Line 638: | ||
| No Violations Noted | | No Violations Noted | ||
| On 7/31/15, I inspected the Harold Haywood site as a routine inspection and made the following observations: | | On 7/31/15, I inspected the Harold Haywood site as a routine inspection and made the following observations: | ||
+ | |- | ||
+ | | 2471489 | ||
+ | | Primary Facility | ||
+ | | 2015-12-11 | ||
+ | | Routine/Partial Inspection | ||
+ | | No Violations Noted | ||
+ | | On 12/11/15, I performed a routine partial inspection of the Harold Haywood Site in response to observed activity on the pad and made the following observations: | ||
+ | |||
|- | |- | ||
| 2549495 | | 2549495 | ||
Line 931: | Line 757: | ||
| No Violations Noted | | No Violations Noted | ||
| Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank. | | Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank. | ||
+ | |- | ||
+ | | 2863149 | ||
+ | | Primary Facility | ||
+ | | 2018-09-07 | ||
+ | | Administrative/File Review | ||
+ | | No Violations Noted | ||
+ | | On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found. | ||
|- | |- | ||
|} | |} |
Well ID: 37-125-27505 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.178758,"lon":-79.976114,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Carroll Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 148479 | |
Farm/Lease Name: HAYWOOD 592444 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-10-28 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.178758 | |
Longitude: -79.976114 |
Date | Event |
---|---|
2014-10-28 | New Permit Application |
2014-12-17 | Performed Spud Operation |
2015-06-30 | Drilling Completion |
2015-09-04 | Perforation |
2015-09-06 | Performed Stimulation |
2016-04-15 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-09-06 | 2015-09-17 | 7,742 | 7,590,070 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | MC MX 437-5 | Multi-Chem Group | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0568675 | 40476.2 |
Hydrochloric Acid (15%) | Keane Group | Acidizing | Hydrochloric acid | 7647-01-0 | 15 | 0.0345494 | 24591 | |
Water | Keane Group | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.989 | 63,339,200.0 | |
AI 250 | Keane Group | Acid corrosion inhibitor | Isopropyl alcohol | 67-63-0 | 40 | 0.000213014 | 151.616 | |
Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00005325 | 37.904 | ||||
Propargyl alcohol | 107-19-7 | 40 | 0.000213014 | 151.616 | ||||
Glycol ethers | 111-76-2 | 40 | 0.000213014 | 151.616 | ||||
Ethoxylated nonylphenol | 68412-54-4 | 13 | 0.00006923 | 49.275 | ||||
FFR760 | Keane Group | Friction reducer | Alkyl alcohol | Proprietary | 10 | 0.00579554 | 4125.06 | |
Hydrotrated light distillate | 64742-47-8 | 30 | 0.0173866 | 12375.2 | ||||
Oxyalkylated alcohol A | Proprietary | 5 | 0.00289777 | 2062.53 | ||||
Sand (Proppant) | Keane Group | Proppant | Silica substrate | 14808-60-7 | 100 | 10.603 | 7,546,820.0 | |
EC6330A | Keane Group | Scale inhibitor | Ethylene glycol | 107-21-1 | 5 | 0.00122332 | 870.713 | |
Sodium phosphate, tribasic | 7601-54-9 | 5 | 0.00122332 | 870.713 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-09-06 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 2,336,582.00 | 331 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 840,220.00 | 339 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 512,775.00 | 347 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 485,586.00 | 308 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Drilling Fluid Waste | 1,210.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracturing Fluid Waste | 34.43 Tons | LANDFILL | 101571 |
2015 | EQT PROD CO | Drill Cuttings | 888.91 Tons | LANDFILL | 100663 |
2015 | EQT PROD CO | Fracing Fluid Waste | 294.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drill Cuttings | 397.00 Tons | LANDFILL | 100172 |
2016 | EQT PROD CO | Produced Fluid | 430.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 6,148.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EQT PROD CO | Produced Fluid | 351.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 390.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 2.37 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2017 | EQT PROD CO | Produced Fluid | 3,273.69 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 46.11 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 40.87 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 3.34 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 6.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 5.90 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 0.95 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 2.38 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ORDER 2016-415 |
2018 | EQT PROD CO | Produced Fluid | 9.83 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 33.71 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Produced Fluid | 304.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 23.23 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 4.57 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 40.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 63.78 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 19.95 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 165.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 5.24 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 5.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Produced Fluid | 816.53 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2019 | EQT PROD CO | Produced Fluid | 37.86 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 57.14 Bbl | INJECTION DISPOSAL WELL | 34-105-23619 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 10.48 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Produced Fluid | 1.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019 | EQT PROD CO | Produced Fluid | 451.87 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 208.21 Bbl | INJECTION DISPOSAL WELL | 34-105-23619 |
2019 | EQT PROD CO | Produced Fluid | 137.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2330918 | Primary Facility | 2014-12-22 | Drilling/Alteration | No Violations Noted | Himes Diversified auger rig |
2344622 | Primary Facility | 2015-02-17 | Drilling/Alteration | No Violations Noted | Alpha Hunter Rig #4 |
2383731 | Primary Facility | 2015-06-30 | Drilling/Alteration | No Violations Noted | Savanna Drilling Rig #803 |
2395342 | Primary Facility | 2015-07-31 | Routine/Complete Inspection | No Violations Noted | On 7/31/15, I inspected the Harold Haywood site as a routine inspection and made the following observations: |
2471489 | Primary Facility | 2015-12-11 | Routine/Partial Inspection | No Violations Noted | On 12/11/15, I performed a routine partial inspection of the Harold Haywood Site in response to observed activity on the pad and made the following observations: |
2549495 | Primary Facility | 2016-12-06 | Routine/Partial Inspection | No Violations Noted | On 12/6/16, I performed a routine partial inspection of the Harold Haywood in response to observed activity on site and made the following observations:
•A drilling rig was being constructed on site at the time of inspection. •A large panel had been set on the pad near the juncture of the pad and access road with a chemical container, multiple metal drums, and multiple pieces of oil covered equipment. A small amount of oil had reached the pad surface. The situation was pointed out to site personnel and was then promptly remediated including removal of all visibly impacted pad material. No violation. •A coil of hose was also found off containment dripping oily material to the pad surface and was promptly removed. No violation. |
2552990 | Primary Facility | 2016-12-16 | Follow-up Inspection | No Violations Noted | On December 16, 2016 I performed a follow up inspection at the Howard Haywood site in response to concerns noted in a previous inspection (ID: 2549486) of the site on 12/6/16 and made the following observations:
•On 12/6/16 multiple issues with containment and minor spills were noted to site personnel and immediately remediated. •Near the junction of the site access road and the pad a large metal plate had been placed so that it was crushing and compromising the containment around multiple pallets of chemicals marked “AES Drilling Fluids”. Multiple other empty chemical storage containers were also found without any containment. This is a violation of 58 Pa. C.S. § 3218.2(d) for failing to provide containment with at least 110% capacity on regulated substances. •A spill of more than ten gallons of antifreeze was found off of containment near the drill rig. The situation was immediately communicated to site personnel for remediation. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code |
2586078 | Primary Facility | 2017-04-24 | Routine/Partial Inspection | No Violations Noted | On 4/24/17 a RTPT inspection was conducted of the Harold Haywood site. The following was observed.
>Multiple areas along the access road bear sparse or patchy vegetation increasing risk of erosion. No violation, remediation recommended. >A topsoil pile near the pad entrance is only partially stabilized with straw. No violation, remediation recommended. > Drilling activity was concluded at the time of inspection and removal of drilling and completion equipment was underway. > The AST remained on site at time of inspection. |
2688453 | Primary Facility | 2018-01-30 | Routine/Complete Inspection | No Violations Noted | On 1/30/18 a routine complete of the Haywood Pad was conducted, the following was observed:
>>Substantial equipment was found stored around the site including multiple lifts and vehicles as well as numerous lights, generators, and tanks. An above ground storage tank was found on site as well. Most equipment had adequate secondary containment. Some stored equipment did not, any leaked or spilled fluids would constitute a violation. >>Wells on site appeared to be in various stages of completion with no rig on site. |
2698954 | Primary Facility | 2017-09-05 | Administrative/File Review | No Violations Noted | On 9/5/17 an administrative inspection related to the Harold Haywood was conducted regarding test results related to complaint ID 328174. No evidence was found in the sample results suggesting impact to the water supply by oil and gas activity. |
2722530 | Primary Facility | 2018-03-27 | Complaint Inspection | No Violations Noted | On 3/27/18 a complaint inspection was conducted in relation to the Harold Haywood Well Site in response to CTS ID: 332966. Sample 3401-071 was collected for chemistry and biological analysis. |
2767171 | Primary Facility | 2018-08-15 | Routine/Partial Inspection | No Violations Noted | On 8/15/18 a routine partial inspection of the Harold Haywood Site was conducted in response to increased activity at the pad. The following was observed:
>>The site was in drilling phase at the time of inspection. High activity was noted on the pad. A drilling rig was active on site at the time of inspection. >>Multiple containers of contaminated equipment were found off containment resulting in minor impacts to the pad. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents pollution to the ground and Waters of the Commonwealth. Any equipment with the potential to cause pollution including equipment contaminated with petroleum residues should be placed and stored on containment. Runoff from improperly stored equipment will result in violations. >>Staining found on the pad near the office trailer suspected to be petroleum based (material was hydrophobic and greasy). This constitutes a viola |
2790085 | Primary Facility | 2018-05-01 | Administrative/File Review | No Violations Noted | On 5/1/18 an administrative inspection related to the Haywood site was conducted to analyze results from sample 3401071 related to complaint ID 332966 collected on 3/27/18. Sample analysis found that while the water did not meet state drinking water standards no clear indicators of oil and gas impact were present. |
2805685 | Primary Facility | 2018-11-02 | Incident- Response to Accident or Event | No Violations Noted | On 11/2/18 a complaint inspection of the Harold Haywood well site was conducted in response an operator reported spill. The following was observed:
>>On 10/31/18 an EQT representative reported that 15 gallons of "impaired water" was spilled to the pad. >>At the time of inspection an operator representative reported that the standing water along the bottom of the AST was found to have very high conductivity during a routine check. The impacted water was pumped out. Field testing of standing water at the time of inspection found water at the site of the initial spill remained impacted with conductivity reading at roughly 1040us. Per the representative the standing water at the time of inspection was believed to be rain water from storms after the initial spill. The impacted water at the time inspection was substantially greater than the 15 gallons initially reported and was in addition to the initial spill. This constitutes a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the opera |
2831182 | Primary Facility | 2019-01-22 | Compliance Evaluation | No Violations Noted | On 1/22/19 a compliance evaluation inspection of the Harold Haywood Well Site was conducted in response to violations recorded on 11/2/18 and 12/16/16. The following was observed:
>>No apparent residual impact related to spill violations from either date were observed. Containment around the AST on site may conceal further impact. No violation. >>Violations related to non-GPU containment were remediated around time of 12/16/16 inspection and addressed with the operator at the time. >>GPUs on site continued to lack containment at the time of inspection including on units installed post 10/2016. Violations ongoing. |
2845207 | Primary Facility | 2019-02-19 | Routine/Complete Inspection | No Violations Noted | Well and pad appear to be in good condition. There are 8 flow back tanks on site and 1 large water tank. |
2863149 | Primary Facility | 2018-09-07 | Administrative/File Review | No Violations Noted | On 9/7/18 an administrative inspection related to the Harold Haywood Pad was conducted to analyze sample and case information pertaining to a water supply complaint (CTS ID: 332966). No evidence of impact was found. |
For data sources see[9]