If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-105-21239 | | Well ID: 37-105-21239 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 41.713909, -78.151608 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: WARRANT 3914 1906 | | Farm/Lease Name: WARRANT 3914 1906 | ||
|- | |- | ||
− | | License Status: | + | | License Status: INACTIVE |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2006-07-07 | | Permit Date: 2006-07-07 | ||
+ | |- | ||
+ | | Well Type: OIL | ||
|- | |- | ||
| Unconventional Well: N | | Unconventional Well: N | ||
|- | |- | ||
| Configuration: Vertical Well | | Configuration: Vertical Well | ||
+ | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
| Latitude: 41.713909 | | Latitude: 41.713909 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2006-07-07 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2006-10-05 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2006-10-10 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2007-08-23 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
<!--== Fracking Activities == | <!--== Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 71: | Line 98: | ||
!scope="col" | Job Percentage by Mass | !scope="col" | Job Percentage by Mass | ||
!scope="col" | Mass Used (lb) | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
|- | |- | ||
|}--> | |}--> | ||
Line 114: | Line 152: | ||
| 2009 | | 2009 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 4362.13 |
| style="text-align: right;" | 365 | | style="text-align: right;" | 365 | ||
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
Line 185: | Line 223: | ||
|- | |- | ||
| 2017 | | 2017 | ||
− | | | + | | style="text-align: right;" | |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 194: | Line 232: | ||
|- | |- | ||
| 2018 | | 2018 | ||
− | | | + | | style="text-align: right;" | |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 220: | Line 258: | ||
| 2010 | | 2010 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 100.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0101508 | | PA0101508 | ||
Line 227: | Line 265: | ||
| 2010 | | 2010 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 233.75 Bbl | | style="text-align: right;" | 233.75 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 234: | Line 272: | ||
| 2010 | | 2010 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 101.75 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0101508 |
|- | |- | ||
| 2010 | | 2010 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 200.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0102784 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 80.95 Bbl | | style="text-align: right;" | 80.95 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 255: | Line 293: | ||
| 2011 | | 2011 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
| style="text-align: right;" | 15.48 Bbl | | style="text-align: right;" | 15.48 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 262: | Line 300: | ||
| 2012 | | 2012 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Drilling Fluid Waste | + | | Produced Fluid |
+ | | style="text-align: right;" | 238.45 Bbl | ||
+ | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
+ | | PA0101508 | ||
+ | |- | ||
+ | | 2012 | ||
+ | | [[PA GEN ENERGY CO LLC]] | ||
+ | | Drilling Fluid Waste | ||
| style="text-align: right;" | 473.25 Bbl | | style="text-align: right;" | 473.25 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| PA0102784 | | PA0102784 | ||
|- | |- | ||
− | | | + | | 2013 |
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 33.33 Bbl |
− | | | + | | CENT WASTE TRT FAC NPDES |
− | | | + | | PA0102784 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | | + | | Servicing Fluid |
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
− | | | + | | PA0101508 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 288.76 Bbl | | style="text-align: right;" | 288.76 Bbl | ||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
Line 290: | Line 335: | ||
| 2013 | | 2013 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Servicing Fluid | + | | Servicing Fluid |
+ | | style="text-align: right;" | 33.33 Bbl | ||
+ | | CENT WASTE TRT FAC NPDES | ||
+ | | PA0101508 | ||
+ | |- | ||
+ | | 2013 | ||
+ | | [[PA GEN ENERGY CO LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 288.76 Bbl | ||
+ | | CENT WASTE TRT FAC NPDES | ||
+ | | PA0101508 | ||
+ | |- | ||
+ | | 2013 | ||
+ | | [[PA GEN ENERGY CO LLC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 33.33 Bbl | | style="text-align: right;" | 33.33 Bbl | ||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
− | | | + | | PA0102784 |
|- | |- | ||
| 2014 | | 2014 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 126.67 Bbl | | style="text-align: right;" | 126.67 Bbl | ||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
Line 304: | Line 363: | ||
| 2014 | | 2014 | ||
| [[PA GEN ENERGY CO LLC]] | | [[PA GEN ENERGY CO LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
+ | | style="text-align: right;" | 164.05 Bbl | ||
+ | | CENT WASTE TRT FAC NPDES | ||
+ | | PA0101508 | ||
+ | |- | ||
+ | | 2014 | ||
+ | | [[PA GEN ENERGY CO LLC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 164.05 Bbl | | style="text-align: right;" | 164.05 Bbl | ||
| CENT WASTE TRT FAC NPDES DISCHARGE | | CENT WASTE TRT FAC NPDES DISCHARGE | ||
| PA0101508 | | PA0101508 | ||
+ | |- | ||
+ | | 2014 | ||
+ | | [[PA GEN ENERGY CO LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 126.67 Bbl | ||
+ | | CENT WASTE TRT FAC NPDES | ||
+ | | PA0102784 | ||
|- | |- | ||
|} | |} |
Well ID: 37-105-21239 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.713909,"lon":-78.151608,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Keating Township | |
Operator Name: MINARD RUN OIL CO | |
Well Pad ID: | |
Farm/Lease Name: WARRANT 3914 1906 | |
License Status: INACTIVE | |
Spud Date: | |
Permit Date: 2006-07-07 | |
Well Type: OIL | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.713909 | |
Longitude: -78.151608 |
Date | Event |
---|---|
2006-07-07 | New Permit Application |
2006-10-05 | Performed Spud Operation |
2006-10-10 | Drilling Completion |
2007-08-23 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2006 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2007 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | PA GEN ENERGY CO LLC | 4,869.11 | 365 | 0.76 | 365 | 0.00 | 0 |
2009 | PA GEN ENERGY CO LLC | 4362.13 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | PA GEN ENERGY CO LLC | 7,268.75 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | PA GEN ENERGY CO LLC | 3,239.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | PA GEN ENERGY CO LLC | 3,202.75 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | PA GEN ENERGY CO LLC | 6,981.33 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | PA GEN ENERGY CO LLC | 6,189.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 | |
2018 | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | PA GEN ENERGY CO LLC | Produced Fluid | 233.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010 | PA GEN ENERGY CO LLC | Produced Fluid | 101.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 200.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | PA GEN ENERGY CO LLC | Produced Fluid | 80.95 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 15.48 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2012 | PA GEN ENERGY CO LLC | Produced Fluid | 238.45 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2012 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 473.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2013 | PA GEN ENERGY CO LLC | Produced Fluid | 33.33 Bbl | CENT WASTE TRT FAC NPDES | PA0102784 |
2013 | PA GEN ENERGY CO LLC | Servicing Fluid | 33.33 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2013 | PA GEN ENERGY CO LLC | Produced Fluid | 288.76 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2013 | PA GEN ENERGY CO LLC | Servicing Fluid | 33.33 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2013 | PA GEN ENERGY CO LLC | Produced Fluid | 288.76 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2013 | PA GEN ENERGY CO LLC | Produced Fluid | 33.33 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0102784 |
2014 | PA GEN ENERGY CO LLC | Produced Fluid | 126.67 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0102784 |
2014 | PA GEN ENERGY CO LLC | Produced Fluid | 164.05 Bbl | CENT WASTE TRT FAC NPDES | PA0101508 |
2014 | PA GEN ENERGY CO LLC | Produced Fluid | 164.05 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2014 | PA GEN ENERGY CO LLC | Produced Fluid | 126.67 Bbl | CENT WASTE TRT FAC NPDES | PA0102784 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2155314 | Primary Facility | 2013-04-10 | Routine/Partial Inspection | No Violations Noted | |
2423921 | Primary Facility | 2015-10-27 | Routine/Complete Inspection | No Violations Noted | |
2609269 | Primary Facility | 2017-06-12 | Routine/Complete Inspection | No Violations Noted | |
2648864 | Primary Facility | 2017-10-17 | Routine/Complete Inspection | No Violations Noted | On 10/17/17 at 1310 hrs I conducted an inspection of the Warrant 3914 1906 well site. No one was present at the site. It was sunny and 57 degrees F.
The well was drilled by the Pennsylvania General Energy Co. (PGE) in 2006 and transferred to the Minard Run Oil Company on 3/23/17. The well was tagged. According to DEP records, the well was in production between 2008 - 2014; it has been on inactive status since 12/23/15. The site is restored and permanently stabilized as per 25 Pa Code Section 102.22(a). A Well Site Restoration Report (WSRR) was received on 11/6/13 and acknowledged on 11/15/13. No violations were cited during the inspection. I departed the location at 1345 hrs. TLT |
2685854 | Primary Facility | 2018-01-23 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was not in production. The wellhead assembly all fittings and flow lines were tested for gas. The results of this testing was no gas was detected on the wellhead assembly or the well area. |
For data sources see[7]