X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-105-21653"

m
m
 
(3 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-105-21653
 
| Well ID: 37-105-21653
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.614718, -77.876531 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.614719, -77.876532 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Potter County, Pennsylvania|Potter]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Wharton Township, Potter County, Pennsylvania|Wharton Township]]
+
| State: Pennsylvania
 +
|-
 +
| County: [[Potter_County,_Pennsylvania|Potter]]
 +
|-
 +
| Municipality: [[Wharton Township,_Potter_County,_Pennsylvania|Wharton Township]]
 
|-
 
|-
 
| Operator Name: [[PA GEN ENERGY CO LLC]]
 
| Operator Name: [[PA GEN ENERGY CO LLC]]
 
|-
 
|-
| Well Pad ID: [[149058|149058]]
+
| Well Pad ID: [[149058]]
 
|-
 
|-
 
| Farm/Lease Name: PINE HILL PAD A 2415
 
| Farm/Lease Name: PINE HILL PAD A 2415
 
|-
 
|-
| First Permit Date: 2010-03-15
+
| License Status:  
|-
 
| Last Permit Date: 2010-03-15
 
 
|-
 
|-
| Spud Date: 2010-04-20
+
| Spud Date:  
 
|-
 
|-
| Unconventional: Yes
+
| Permit Date: 2010-03-15
 
|-
 
|-
| Horizontal: Yes
+
| Well Type: GAS
 
|-
 
|-
| Well Status: ACTIVE
+
| Unconventional Well: Y
 
|-
 
|-
| Violations: 0
+
| Configuration: Horizontal Well
 
|-
 
|-
| Latitude: 41.614718
+
| Conservation: No
 
|-
 
|-
| Longitude: -77.876531
+
| Latitude: 41.614719
 
|-
 
|-
 +
| Longitude: -77.876532
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Date
!scope="col" | GAS QUANTITY
+
!scope="col" | Event
!scope="col" | GAS PRODUCTION DAYS
 
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2010-3
+
| 2010-03-15
| style="text-align:right;" | 0.0
+
| New Permit Application
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2010-04-20
 +
| Performed Spud Operation
 
|-
 
|-
| 2010-2
+
| 2010-08-19
| style="text-align:right;" | 0.0
+
| Drilling Completion
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2011-03-04
 +
| DEVIATED
 
|-
 
|-
| 2010-2
+
|}
| style="text-align:right;" | 0.0
+
For data sources see<ref>{{cite web
| style="text-align:right;" | 0.0
+
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
| style="text-align:right;" | 0.0
+
| date = 2020-02-27
| style="text-align:right;" | 0.0
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
| style="text-align:right;" | 0.0
+
| accessdate = 2020-02-27 }}</ref>
| style="text-align:right;" | 0.0
+
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
 +
| 1
 +
| 2010-11-01
 +
| 2010-11-01
 +
| style="text-align: right;" | 6,200
 +
| style="text-align: right;" | 5,814,438
 +
| style="text-align: right;" |
 
|-
 
|-
| 2011-1
+
|}
| style="text-align:right;" | 245278.0
+
==== Fluid Composition Data ====
| style="text-align:right;" | 150.0
+
{| class="wikitable sortable" width="95%"
| style="text-align:right;" | 0.0
+
!scope="col" | Job Number
| style="text-align:right;" | 0.0
+
!scope="col" | Trade Name
| style="text-align:right;" | 0.0
+
!scope="col" | Supplier
| style="text-align:right;" | 0.0
+
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="19"| 1
 +
| rowspan="1"| Water*
 +
| rowspan="1"| PGE
 +
| rowspan="1"| Carrier/Base Fluid
 +
|
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 85.6132
 +
| style="text-align: right;" |
 
|-
 
|-
| 2011-2
+
|- valign="top"
| style="text-align:right;" | 192329.0
+
| rowspan="1"| KR-153SL
| style="text-align:right;" | 184.0
+
| rowspan="1"| Superior Well Services
| style="text-align:right;" | 0.0
+
| rowspan="1"| Biocide
| style="text-align:right;" | 0.0
+
| 2,2-Dibromo-3-nitrilo-propionamide
| style="text-align:right;" | 0.0
+
| 10222-01-2
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 20.0
 +
| style="text-align: right;" | 0.00176
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica (quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 12.98117
 +
| style="text-align: right;" |
 
|-
 
|-
| 2012-1
+
|- valign="top"
| style="text-align:right;" | 127182.0
+
| rowspan="1"| AI -2
| style="text-align:right;" | 182.0
+
| rowspan="1"| Superior Well Services
| style="text-align:right;" | 0.0
+
| rowspan="1"| Acid Inhibitor
| style="text-align:right;" | 0.0
+
| Glycol Ether
| style="text-align:right;" | 0.0
+
| 111-76-2
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| WFR-3B
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated Light Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.02344
 +
| style="text-align: right;" |
 
|-
 
|-
| 2012-2
+
|- valign="top"
| style="text-align:right;" | 100054.0
+
| rowspan="1"| Super TSC
| style="text-align:right;" | 180.0
+
| rowspan="1"| Superior Well Services
| style="text-align:right;" | 0.0
+
| rowspan="1"| Scale Inhibitor
| style="text-align:right;" | 0.0
+
| Propylene glycol
| style="text-align:right;" | 0.0
+
| 57-55-6
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.0051
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Acid, Hydrochloric (3)
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Solvent
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 3.0
 +
| style="text-align: right;" | 0.03925
 +
| style="text-align: right;" |
 
|-
 
|-
| 2013-1
+
|- valign="top"
| style="text-align:right;" | 99493.0
+
| rowspan="12"|  
| style="text-align:right;" | 181.0
+
| rowspan="12"|  
| style="text-align:right;" | 0.0
+
| rowspan="12"|  
| style="text-align:right;" | 0.0
+
| Polyethylene Glycol
| style="text-align:right;" | 0.0
+
| 25322-68-3
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00439
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
| Ethoxylated Alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00313
 +
| style="text-align: right;" |
 
|-
 
|-
| 2013-2
+
| 2-Phosphonobutane-1,2,4 tricarboxylic acid
| style="text-align:right;" | 92242.0
+
| 37971-36-1
| style="text-align:right;" | 181.0
+
| style="text-align: right;" | 10.0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00102
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Mineral Spirits
 +
| 8052-41-3
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00781
 +
| style="text-align: right;" |
 
|-
 
|-
| 2014-1
+
| Diethylene Glycol
| style="text-align:right;" | 74171.0
+
| 111-46-6
| style="text-align:right;" | 128.0
+
| style="text-align: right;" | 3.5
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00031
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Anionic copolymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00102
 +
| style="text-align: right;" |
 
|-
 
|-
| 2014-2
+
| Propylene Glycol
| style="text-align:right;" | 81047.0
+
| 57-55-6
| style="text-align:right;" | 178.0
+
| style="text-align: right;" | 25.0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.01954
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Anionic polymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00102
 +
| style="text-align: right;" |
 
|-
 
|-
| 2015-02
+
| Propargyl Alcohol
| style="text-align:right;" | 10753.0
+
| 107-19-7
| style="text-align:right;" | 28.0
+
| style="text-align: right;" | 30.0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00008000
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| Isopropyl Alcohol
 +
| 67-63-0
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2015-01
+
| Ethylene Glycol
| style="text-align:right;" | 11877.0
+
| 107-21-1
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 1.0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00878
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|-
+
| Proprietary Component
| 2015-03
+
| Proprietary
| style="text-align:right;" | 12213.0
+
| style="text-align: right;" | 7.0
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 0.00002000
| style="text-align:right;" | 0.0
+
| style="text-align: right;" |  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Production Report
+
  | title =FracFocus Fracking Chemicals Database
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| date = 2019-04-02
| date = 2015-05-26
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
+
  | accessdate = 2019-06-19 }}</ref>
  | accessdate = 2015-05-27 }}</ref>
+
<!--== Stimulation Data ==
== Waste Data ==
+
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator Name
!scope="col" | QUANTITY
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | UNITS
+
!scope="col" | Gas Production Days
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Oil Production Days
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Water Quantity (bbl)
!scope="col" | FACILITY CITY
+
!scope="col" | Water Production Days
!scope="col" | FACILITY STATE
+
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 437,607.00
 +
| style="text-align: right;" | 334
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 227,236.00
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 191,735.00
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 155,218.00
 +
| style="text-align: right;" | 306
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 136,751.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 117,456.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-3
+
| 2017
| DRILL CUTTINGS
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 257.43
+
| style="text-align: right;" | 104,229.00
| Tons
+
| style="text-align: right;" | 363
| ON SITE ENCAPSULATION
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
| ON SITE DISPOSAL PURSUANT TO 25 PA CODE 78.62
+
| style="text-align: right;" | 0.00
|  
+
| style="text-align: right;" | 0
| PA
 
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 93,818.00
 +
| style="text-align: right;" | 363
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-3
+
| 2019
| DRILLING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 33.33
+
| style="text-align: right;" | 82,970.00
| Bbl
+
| style="text-align: right;" | 314
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| style="text-align: right;" | 0.00
| PA0102784
+
| style="text-align: right;" | 0
| WASTE TREATMENT CORPORATION
+
| style="text-align: right;" | 0.00
| WARREN
+
| style="text-align: right;" | 0
| PA
 
 
|-
 
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2010-2
+
| 2010
| DRILL CUTTINGS
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 695.1
+
| Drill Cuttings
| Tons
+
| style="text-align: right;" | 695.10 Tons
 
| LANDFILL
 
| LANDFILL
 
| 100361
 
| 100361
| MCKEAN COUNTY LANDFILL
 
| KANE
 
| PA
 
 
|-
 
|-
|-
+
| 2010
| 2010-2
+
| [[PA GEN ENERGY CO LLC]]
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste
| style="text-align:right;" | 67.0
+
| style="text-align: right;" | 1,683.66 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| PA0101508
+
| PA0102784
| FLUID RECOVERY SERVICE FRANKLIN FACILITY
 
| FRANKLIN
 
| PA
 
|-
 
 
|-
 
|-
| 2010-2
+
| 2010
| DRILLING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1.0
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 7,819.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0102784
 
| PA0102784
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
|-
 
 
|-
 
|-
| 2010-2
+
| 2010
| FRACING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 464.0
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 464.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
| PA0101508
| FLUID RECOVERY SERVICE FRANKLIN FACILITY
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
|-
+
| 2010
| 2010-2
+
| [[PA GEN ENERGY CO LLC]]
| FRACING FLUID WASTE
+
| Produced Fluid
| style="text-align:right;" | 7.0
+
| style="text-align: right;" | 1,705.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| PA0102784
+
| PA0101508
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
|-
+
| 2010
| 2010-2
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Drilling Fluid Waste
| style="text-align:right;" | 1.0
+
| style="text-align: right;" | 67.00 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
| PA0101508
| FLUID RECOVERY SERVICE FRANKLIN FACILITY
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 128.72 Tons
 +
| ON SITE ENCAPSULATION
 +
|
 
|-
 
|-
| 2010-2
+
| 2010
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 748.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 748.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0102784
 
| PA0102784
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
|-
 
 
|-
 
|-
| 2011-1
+
| 2011
| FLOWBACK FRACTURING SAND
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 66.49
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 66.49 Tons
 
| LANDFILL
 
| LANDFILL
 
| NY # 02S17
 
| NY # 02S17
| HYLAND FACILITY ASSOCIATION
 
| ANGELICA
 
| NY
 
 
|-
 
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 6,068.19 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| UIC 45
 
|-
 
|-
| 2011-1
+
| 2011
| FLOWBACK FRACTURING SAND
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 100.29
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 100.29 Tons
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| 4835146
+
| 004835146
| MAX ENVIRONMENTAL
 
| PITTSBURGH
 
| PA
 
 
|-
 
|-
|-
+
| 2011
| 2011-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 3,403.37 Bbl
| Bbl
 
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
| PA0101508
| PA BRINE
 
|
 
| PA
 
 
|-
 
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 117.75 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-21076
 
|-
 
|-
| 2011-1
+
| 2011
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 708.46
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 227.56 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0102784
+
| 34-007-24355
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
|-
+
| 2011
| 2011-2
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 43.98
+
| style="text-align: right;" | 43.98 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-133-24096
 
| 34-133-24096
| GROSELLE INECTION WELL # 2
 
| GARRETTSVILLE
 
| OH
 
|-
 
|-
 
| 2011-2
 
| PRODUCED FLUID
 
| style="text-align:right;" | 227.56
 
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-007-24355
 
| MILLER & CO #3 (SWIW #28)
 
| GARRETTSVILLE
 
| OH
 
 
|-
 
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 708.46 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 
|-
 
|-
| 2011-2
+
| 2011
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 104.32
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 104.32 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| 34-099-23127
 
| 34-099-23127
| NORTHSTAR #1
 
| YOUNGSTOWN
 
| OH
 
|-
 
 
|-
 
|-
| 2011-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 6.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,037.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| UIC 45
+
| 34-155-21893
| RAY PANDER TRUCKING INC
 
| DIAMOND
 
| OH
 
 
|-
 
|-
|-
+
| 2012
| 2011-2
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 117.75
+
| style="text-align: right;" | 2,745.75 Bbl
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-133-21076
 
| SALTYS DISPOSAL - MYERS INECTION WELL #1
 
| PARIS
 
| OH
 
|-
 
|-
 
| 2012-1
 
| PRODUCED FLUID
 
| style="text-align:right;" | 419.75
 
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-151-23420
 
| BELDEN & BLAKE WELL # 2
 
| HARTVILLE
 
| OH
 
|-
 
|-
 
| 2012-1
 
| PRODUCED FLUID
 
| style="text-align:right;" | 1.0
 
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-23795
 
| 34-155-23795
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
|-
+
| 2012
| 2012-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 755.69
+
| style="text-align: right;" | 755.69 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
|
 
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
 
|  
 
|  
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 308.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 
|-
 
|-
| 2012-1
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 730.5
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 419.75 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21893
+
| 34-151-23420
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
|-
 
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 4.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 4,959.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR123NW005
 
| WMGR123NW005
| CARES MCKEAN WATER TRMT & RECYCLING FAC
 
| MOUNT JEWITT
 
| PA
 
|-
 
|-
 
| 2012-2
 
| PRODUCED FLUID
 
| style="text-align:right;" | 1.0
 
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-23795
 
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
|-
 
|-
 
| 2012-2
 
| PRODUCED FLUID
 
| style="text-align:right;" | 307.0
 
| Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-155-21893
 
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
|-
 
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 308.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 308.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21894
 
| 34-155-21894
| WOLF #2 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
|-
 
 
|-
 
|-
| 2012-2
+
| 2013
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 308.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 26.26 Bbl
| INJECTION DISPOSAL WELL
 
| 34-155-23203
 
| WOLF #4 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
|-
 
|-
 
| 2013-1
 
| PRODUCED FLUID
 
| style="text-align:right;" | 26.26
 
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-133-22523
 
| 34-133-22523
| MILLER #1 DISP WELL
 
| WINDHAM
 
| OH
 
 
|-
 
|-
|-
+
| 2013
| 2013-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 995.5
+
| style="text-align: right;" | 399.17 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23795
+
| 34-155-23203
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
|-
+
| 2013
| 2013-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 77.5
+
| style="text-align: right;" | 103.74 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-133-23614
 
| 34-133-23614
| PLUM CREEK #1 DISPOSAL WELL
 
| KENT
 
| OH
 
 
|-
 
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 27.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 
|-
 
|-
| 2013-1
+
| 2013
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 252.5
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 399.17 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21893
 
| 34-155-21893
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
|-
+
| 2013
| 2013-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 252.5
+
| style="text-align: right;" | 399.17 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21894
 
| 34-155-21894
| WOLF #2 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
|-
+
| 2013
| 2013-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 252.5
+
| style="text-align: right;" | 1,754.00 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23203
+
| 34-155-23795
| WOLF #4 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
|-
 
 
|-
 
|-
| 2013-2
+
| 2013
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 233.79
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 233.79 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-22403
 
| 34-155-22403
| ANNAROCK D-1
 
| FOWLER
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 264.73 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 
|-
 
|-
| 2013-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 27.5
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 264.73 Bbl
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
+
| INJECTION DISPOSAL WELL
| WMGR119
+
| 34-155-23203
| EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
|-
+
| 2014
| 2013-2
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 758.5
+
| style="text-align: right;" | 703.64 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-23795
 
| 34-155-23795
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 148.76 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21447
 
|-
 
|-
| 2013-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 26.24
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 28.76 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-133-23614
+
| 34-151-23420
| PLUM CREEK #1 DISPOSAL WELL
 
| KENT
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 237.51 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 
|-
 
|-
| 2013-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 146.67
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 264.73 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-21893
 
| 34-155-21893
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 250.05 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21438
 
|-
 
|-
| 2013-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 146.67
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 99.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21894
+
| 34-155-23759
| WOLF #2 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 50.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23732
 
|-
 
|-
| 2013-2
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 146.67
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 177.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23203
+
| 34-155-21447
| WOLF #4 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 75.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24078
 
|-
 
|-
| 2014-1
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 76.25
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 181.50 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| 34-155-22403
+
| WMGR123NC010
| ANNAROCK D-1
+
|-
| FOWLER
+
| 2015
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 794.50 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW011
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 52.50 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123
 
|-
 
|-
| 2014-1
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 367.62
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 160.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23795
+
| 34-155-21438
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 50.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW005
 
|-
 
|-
| 2014-1
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 145.83
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 26.25 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21893
+
| 34-007-21847
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
|-
+
| 2015
| 2014-1
+
| [[PA GEN ENERGY CO LLC]]
| PRODUCED FLUID
+
| Produced Fluid
| style="text-align:right;" | 145.83
+
| style="text-align: right;" | 25.00 Bbl
| Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21894
+
| 34-155-23759
| WOLF #2 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 753.25 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2014-1
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 145.83
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 157.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23203
+
| 34-155-23732
| WOLF #4 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 281.25 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW005
 
|-
 
|-
| 2014-2
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 161.26
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 10.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-22403
+
| 34-007-2-3097
| ANNAROCK D-1
 
| FOWLER
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,758.25 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW011
 
|-
 
|-
| 2014-2
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 28.76
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 10.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-151-23420
+
| 34-007-24355
| BELDEN & BLAKE WELL # 2
 
| HARTVILLE
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 10.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-2-3692
 
|-
 
|-
| 2014-2
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 250.05
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 10.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21438
+
| 34-007-2-3177
| KLEESE #1 (SWIW #18)
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 10.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-23262
 
|-
 
|-
| 2014-2
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 148.76
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 52.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21447
+
| 34-007-21847
| KLEESE #2 (SWIW #19)
+
|-
| VIENNA
+
| 2017
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,716.25 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
 +
| 2017
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 112.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 
|-
 
|-
| 2014-2
+
| 2017
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 50.0
+
| Other Oil & Gas Wastes
| Bbl
+
| style="text-align: right;" | 40.00 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-155-23732
+
| WMGR123NW011
| KLEESE #4 (SWIW #24)
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 282.50 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2018
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 99.5
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,450.00 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-155-23759
+
| WMGR123NW011
| KLEESE #5 (SWIW #25)
 
| TRUMBULL
 
| OH
 
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 27.50 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 
|-
 
|-
| 2014-2
+
| 2018
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 336.02
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 207.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-23795
+
| 34-007-21847
| PANDER #1 (SWIW #15)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 439.25 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D215BWAR
 
|-
 
|-
| 2014-2
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 118.9
+
| Other Oil & Gas Wastes
| Bbl
+
| style="text-align: right;" | 25.00 Bbl
| INJECTION DISPOSAL WELL
+
| REUSE (AT WELL PAD)
| 34-155-21893
+
|  
| WOLF #1 DISP WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 273.75 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2014-2
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 118.9
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 358.75 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-21894
+
| 34-007-21847
| WOLF #2 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 12.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D215BWAR
 
|-
 
|-
| 2014-2
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 118.9
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 137.50 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-155-23203
+
| WMGR123NW011
| WOLF #4 DISPOSAL WELL
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Waste Report
+
  | title =Oil and Gas Waste Reports
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-03-31
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-26 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
!scope="col" | VIOLATION CODE
+
!scope="col" | Inspection Comments
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
 
| 1907252
 
| 1907252
 +
| Primary Facility
 
| 2010-08-19
 
| 2010-08-19
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1928112
 
| 1928112
 +
| Primary Facility
 
| 2010-11-12
 
| 2010-11-12
 +
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
|
 
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2016934
 
| 2016934
 +
| Primary Facility
 
| 2011-11-02
 
| 2011-11-02
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
| An inspection was conducted at the Pine Hill Pad A  site on 11/2/11.  The E&S plan and site perimeter were observed.  The wells is production and the site was stable.  No violations were cited during this inspection.  - MRN
 
| An inspection was conducted at the Pine Hill Pad A  site on 11/2/11.  The E&S plan and site perimeter were observed.  The wells is production and the site was stable.  No violations were cited during this inspection.  - MRN
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2103018
 
| 2103018
 +
| Primary Facility
 
| 2012-09-12
 
| 2012-09-12
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2146946
 
| 2146946
 +
| Primary Facility
 
| 2013-03-11
 
| 2013-03-11
 +
| Site Restoration
 
| No Violations Noted
 
| No Violations Noted
| An inspection of the Pine Hill Pad A in Wharton township, Potter County was conducted on March 11, 2013 in response to a Well Site Restoration Reports received by the Department (for wells 1941, 2143, 2414 and 2415) .  The site was determined to meet the requirements of 25 Pa Code ᄃ102.22(a)(2) (i) Permanent Stabilization.  A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed.  The Restoration reports were deemed approved.  No violations were cited during this inspection.
+
| An inspection of the Pine Hill Pad A in Wharton township, Potter County was conducted on March 11, 2013 in response to a Well Site Restoration Reports received by the Department (for wells 1941, 2143, 2414 and 2415) .  The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization.  A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed.  The Restoration reports were deemed approved.  No violations were cited during this inspection.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 2364541
 
| 2364541
 +
| Primary Facility
 
| 2015-04-20
 
| 2015-04-20
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2461453
 +
| Primary Facility
 +
| 2016-03-04
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine inspection. Four wells have been drilled. Site is restored. Pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations cited. TLT
 +
|-
 +
| 2576298
 +
| Primary Facility
 +
| 2017-03-28
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
|  
+
|-
|  
+
| 2687479
 +
| Primary Facility
 +
| 2018-01-26
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of this inspection this well was in production. The wellhead assembly all fittings all flow lines and cellar area was tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area.
 +
|-
 +
| 2722136
 +
| Primary Facility
 +
| 2018-04-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Four wells have been drilled. The site is restored per the requirements of post-drilling restoration  The impervious area of the pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations were noted during this inspection
 +
|-
 +
| 2737870
 +
| Primary Facility
 +
| 2018-06-05
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of this inspection this well was in production.
 +
|-
 +
| 2802452
 +
| Primary Facility
 +
| 2018-11-09
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| Admin inspection for purpose of linking to a plugging COA.
 +
|-
 +
| 2823910
 +
| Primary Facility
 +
| 2019-01-09
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of this inspection this well was in production. The gauge was showing 400 pounds per square inch on the approximate 3" flow line. This well has the annular vents hard piped /plumbed to the waste/ production tanks that are in a steel walled containment. No violations were noted at this inspection.
 +
|-
 +
| 2834170
 +
| Primary Facility
 +
| 2019-01-30
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| The DEP conducted an incident inspection of PGE's Pine Hill 1941 Well Pad in Wharton Twp, Potter County on 1/30/2019 at 1215 hours. The inspection was conducted in response to a spill reported to the DEP Report hotline by Nathan Harris (PGE). It was reported that at approximately 0900 a vac truck that was moving produced water from a production tank had "collapsed". The tank was estimated to have had 25 barrels of liquid inside when it collapsed.
 +
 
 +
DEP WQS, Jonathan Pennings and I arrived onsite at 1215 hours. When we arrived the truck was still in place and crew was observed sucking up fluids from the pad surface. We observed the vac truck(see photo #1) and the impacted area (photo #2 & 14). Puddles and slush mixes were field measured with a PCSTestr returning readings ranging from ~2.0 ms/cm to ~15.0 ms/cm (see photos #3, 4 & 5).
 +
 
 +
We spoke with Erick Duzick (PGE Completions Engineer) onsite who explained the vac trucks relief valve was frozen solid which had caused the truck to create a vacuum which in ret
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Oil and Gas Historical Inspection Report
+
  | title =Oil and Gas Compliance Report
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| date = 2015-05-26
+
| date = 2019-05-20
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
+
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
  | accessdate = 2015-05-27 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 16:29, 15 May 2020

Well Details

Well ID: 37-105-21653
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Wharton Township
Operator Name: PA GEN ENERGY CO LLC
Well Pad ID: 149058
Farm/Lease Name: PINE HILL PAD A 2415
License Status:
Spud Date:
Permit Date: 2010-03-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.614719
Longitude: -77.876532

For data sources see[1][2][3]

Well History

Date Event
2010-03-15 New Permit Application
2010-04-20 Performed Spud Operation
2010-08-19 Drilling Completion
2011-03-04 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2010-11-01 2010-11-01 6,200 5,814,438

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water* PGE Carrier/Base Fluid 7732-18-5 100.0 85.6132
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilo-propionamide 10222-01-2 20.0 0.00176
Sand Superior Well Services Proppant Crystalline Silica (quartz) 14808-60-7 100.0 12.98117
AI -2 Superior Well Services Acid Inhibitor Glycol Ether 111-76-2 30.0 0.00008000
WFR-3B Superior Well Services Friction Reducer Hydrotreated Light Distillate 64742-47-8 30.0 0.02344
Super TSC Superior Well Services Scale Inhibitor Propylene glycol 57-55-6 50.0 0.0051
Acid, Hydrochloric (3) Superior Well Services Solvent Hydrochloric Acid 7647-01-0 3.0 0.03925
Polyethylene Glycol 25322-68-3 50.0 0.00439
Ethoxylated Alcohols 68551-12-2 4.0 0.00313
2-Phosphonobutane-1,2,4 tricarboxylic acid 37971-36-1 10.0 0.00102
Mineral Spirits 8052-41-3 10.0 0.00781
Diethylene Glycol 111-46-6 3.5 0.00031
Anionic copolymer Proprietary 10.0 0.00102
Propylene Glycol 57-55-6 25.0 0.01954
Anionic polymer Proprietary 10.0 0.00102
Propargyl Alcohol 107-19-7 30.0 0.00008000
Isopropyl Alcohol 67-63-0 30.0 0.00008000
Ethylene Glycol 107-21-1 1.0 0.00878
Proprietary Component Proprietary 7.0 0.00002000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 437,607.00 334 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 227,236.00 362 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 191,735.00 362 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 155,218.00 306 0.00 0 0.00 0
2015 PA GEN ENERGY CO LLC 136,751.00 365 0.00 0 0.00 0
2016 PA GEN ENERGY CO LLC 117,456.00 366 0.00 0 0.00 0
2017 PA GEN ENERGY CO LLC 104,229.00 363 0.00 0 0.00 0
2018 PA GEN ENERGY CO LLC 93,818.00 363 0.00 0 0.00 0
2019 PA GEN ENERGY CO LLC 82,970.00 314 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 PA GEN ENERGY CO LLC Drill Cuttings 695.10 Tons LANDFILL 100361
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 1,683.66 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 PA GEN ENERGY CO LLC Fracing Fluid Waste 7,819.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 PA GEN ENERGY CO LLC Fracing Fluid Waste 464.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 PA GEN ENERGY CO LLC Produced Fluid 1,705.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 67.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 PA GEN ENERGY CO LLC Drill Cuttings 128.72 Tons ON SITE ENCAPSULATION
2010 PA GEN ENERGY CO LLC Produced Fluid 748.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 PA GEN ENERGY CO LLC Fracturing Fluid Waste 66.49 Tons LANDFILL NY # 02S17
2011 PA GEN ENERGY CO LLC Produced Fluid 6,068.19 Bbl INJECTION DISPOSAL WELL UIC 45
2011 PA GEN ENERGY CO LLC Fracturing Fluid Waste 100.29 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 004835146
2011 PA GEN ENERGY CO LLC Produced Fluid 3,403.37 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 PA GEN ENERGY CO LLC Produced Fluid 117.75 Bbl INJECTION DISPOSAL WELL 34-133-21076
2011 PA GEN ENERGY CO LLC Produced Fluid 227.56 Bbl INJECTION DISPOSAL WELL 34-007-24355
2011 PA GEN ENERGY CO LLC Produced Fluid 43.98 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011 PA GEN ENERGY CO LLC Produced Fluid 708.46 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 PA GEN ENERGY CO LLC Produced Fluid 104.32 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2012 PA GEN ENERGY CO LLC Produced Fluid 1,037.50 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 PA GEN ENERGY CO LLC Produced Fluid 2,745.75 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 PA GEN ENERGY CO LLC Produced Fluid 755.69 Bbl REUSE OTHER THAN ROAD SPREADING
2012 PA GEN ENERGY CO LLC Produced Fluid 308.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012 PA GEN ENERGY CO LLC Produced Fluid 419.75 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 PA GEN ENERGY CO LLC Produced Fluid 4,959.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2012 PA GEN ENERGY CO LLC Produced Fluid 308.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 PA GEN ENERGY CO LLC Produced Fluid 26.26 Bbl INJECTION DISPOSAL WELL 34-133-22523
2013 PA GEN ENERGY CO LLC Produced Fluid 399.17 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 PA GEN ENERGY CO LLC Produced Fluid 103.74 Bbl INJECTION DISPOSAL WELL 34-133-23614
2013 PA GEN ENERGY CO LLC Produced Fluid 27.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 PA GEN ENERGY CO LLC Produced Fluid 399.17 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 PA GEN ENERGY CO LLC Produced Fluid 399.17 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 PA GEN ENERGY CO LLC Produced Fluid 1,754.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013 PA GEN ENERGY CO LLC Produced Fluid 233.79 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014 PA GEN ENERGY CO LLC Produced Fluid 264.73 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014 PA GEN ENERGY CO LLC Produced Fluid 264.73 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014 PA GEN ENERGY CO LLC Produced Fluid 703.64 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014 PA GEN ENERGY CO LLC Produced Fluid 148.76 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014 PA GEN ENERGY CO LLC Produced Fluid 28.76 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014 PA GEN ENERGY CO LLC Produced Fluid 237.51 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014 PA GEN ENERGY CO LLC Produced Fluid 264.73 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 PA GEN ENERGY CO LLC Produced Fluid 250.05 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 PA GEN ENERGY CO LLC Produced Fluid 99.50 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 PA GEN ENERGY CO LLC Produced Fluid 50.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2015 PA GEN ENERGY CO LLC Produced Fluid 177.50 Bbl INJECTION DISPOSAL WELL 34-155-21447
2015 PA GEN ENERGY CO LLC Produced Fluid 75.00 Bbl INJECTION DISPOSAL WELL 34-155-24078
2015 PA GEN ENERGY CO LLC Produced Fluid 181.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 PA GEN ENERGY CO LLC Produced Fluid 794.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 PA GEN ENERGY CO LLC Produced Fluid 52.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 PA GEN ENERGY CO LLC Produced Fluid 160.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 PA GEN ENERGY CO LLC Produced Fluid 50.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015 PA GEN ENERGY CO LLC Produced Fluid 26.25 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 PA GEN ENERGY CO LLC Produced Fluid 25.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2015 PA GEN ENERGY CO LLC Produced Fluid 753.25 Bbl REUSE OTHER THAN ROAD SPREADING
2015 PA GEN ENERGY CO LLC Produced Fluid 157.50 Bbl INJECTION DISPOSAL WELL 34-155-23732
2016 PA GEN ENERGY CO LLC Produced Fluid 281.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 PA GEN ENERGY CO LLC Produced Fluid 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016 PA GEN ENERGY CO LLC Produced Fluid 1,758.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 PA GEN ENERGY CO LLC Produced Fluid 10.50 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016 PA GEN ENERGY CO LLC Produced Fluid 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2016 PA GEN ENERGY CO LLC Produced Fluid 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2016 PA GEN ENERGY CO LLC Produced Fluid 10.50 Bbl INJECTION DISPOSAL WELL 34-007-23262
2016 PA GEN ENERGY CO LLC Produced Fluid 52.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2017 PA GEN ENERGY CO LLC Produced Fluid 1,716.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 PA GEN ENERGY CO LLC Produced Fluid 112.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 282.50 Bbl REUSE (AT WELL PAD)
2018 PA GEN ENERGY CO LLC Produced Fluid 1,450.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 PA GEN ENERGY CO LLC Produced Fluid 207.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 PA GEN ENERGY CO LLC Produced Fluid 439.25 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 25.00 Bbl REUSE (AT WELL PAD)
2019 PA GEN ENERGY CO LLC Produced Fluid 273.75 Bbl REUSE (AT WELL PAD)
2019 PA GEN ENERGY CO LLC Produced Fluid 358.75 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 12.50 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019 PA GEN ENERGY CO LLC Produced Fluid 137.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1907252 Primary Facility 2010-08-19 Drilling/Alteration No Violations Noted
1928112 Primary Facility 2010-11-12 Routine/Partial Inspection No Violations Noted
2016934 Primary Facility 2011-11-02 Routine/Complete Inspection No Violations Noted An inspection was conducted at the Pine Hill Pad A site on 11/2/11. The E&S plan and site perimeter were observed. The wells is production and the site was stable. No violations were cited during this inspection. - MRN
2103018 Primary Facility 2012-09-12 Routine/Complete Inspection No Violations Noted
2146946 Primary Facility 2013-03-11 Site Restoration No Violations Noted An inspection of the Pine Hill Pad A in Wharton township, Potter County was conducted on March 11, 2013 in response to a Well Site Restoration Reports received by the Department (for wells 1941, 2143, 2414 and 2415) . The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed. The Restoration reports were deemed approved. No violations were cited during this inspection.
2364541 Primary Facility 2015-04-20 Routine/Complete Inspection No Violations Noted
2461453 Primary Facility 2016-03-04 Routine/Complete Inspection No Violations Noted Routine inspection. Four wells have been drilled. Site is restored. Pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations cited. TLT
2576298 Primary Facility 2017-03-28 Routine/Complete Inspection No Violations Noted
2687479 Primary Facility 2018-01-26 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings all flow lines and cellar area was tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area.
2722136 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted Four wells have been drilled. The site is restored per the requirements of post-drilling restoration The impervious area of the pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations were noted during this inspection
2737870 Primary Facility 2018-06-05 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production.
2802452 Primary Facility 2018-11-09 Administrative/File Review No Violations Noted Admin inspection for purpose of linking to a plugging COA.
2823910 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The gauge was showing 400 pounds per square inch on the approximate 3" flow line. This well has the annular vents hard piped /plumbed to the waste/ production tanks that are in a steel walled containment. No violations were noted at this inspection.
2834170 Primary Facility 2019-01-30 Incident- Response to Accident or Event No Violations Noted The DEP conducted an incident inspection of PGE's Pine Hill 1941 Well Pad in Wharton Twp, Potter County on 1/30/2019 at 1215 hours. The inspection was conducted in response to a spill reported to the DEP Report hotline by Nathan Harris (PGE). It was reported that at approximately 0900 a vac truck that was moving produced water from a production tank had "collapsed". The tank was estimated to have had 25 barrels of liquid inside when it collapsed.

DEP WQS, Jonathan Pennings and I arrived onsite at 1215 hours. When we arrived the truck was still in place and crew was observed sucking up fluids from the pad surface. We observed the vac truck(see photo #1) and the impacted area (photo #2 & 14). Puddles and slush mixes were field measured with a PCSTestr returning readings ranging from ~2.0 ms/cm to ~15.0 ms/cm (see photos #3, 4 & 5).

We spoke with Erick Duzick (PGE Completions Engineer) onsite who explained the vac trucks relief valve was frozen solid which had caused the truck to create a vacuum which in ret

For data sources see[8]