X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-117-21051"

m
m
 
(6 intermediate revisions by the same user not shown)
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-21051
 
| Well ID: 37-117-21051
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.719666, -77.120511 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.719667, -77.120511 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Tioga County, Pennsylvania|Tioga]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Covington Township, Tioga County, Pennsylvania|Covington Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[SWEPI LP|SWEPI LP]]
+
| County: [[Tioga_County,_Pennsylvania|Tioga]]
 +
|-
 +
| Municipality: [[Covington Township,_Tioga_County,_Pennsylvania|Covington Township]]
 +
|-
 +
| Operator Name: [[SWEPI LP]]
 
|-
 
|-
 
| Well Pad ID: [[149447]]
 
| Well Pad ID: [[149447]]
Line 15: Line 19:
 
| Farm/Lease Name: TORPY & VAN ORDER INC 574 1V
 
| Farm/Lease Name: TORPY & VAN ORDER INC 574 1V
 
|-
 
|-
| First Permit Date: 2010-12-07
+
| License Status: PLUGGED & ABANDONED
 
|-
 
|-
| Last Permit Date: 2010-12-07
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2011-01-19
+
| Permit Date: 2010-12-07
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: No
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Vertical Well
 
|-
 
|-
| Violations: None
+
| Conservation: No
 
|-
 
|-
| Latitude: 41.719666
+
| Latitude: 41.719667
 
|-
 
|-
 
| Longitude: -77.120511
 
| Longitude: -77.120511
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2010-12-07
 +
| New Permit Application
 +
|-
 +
| 2011-01-19
 +
| Performed Spud Operation
 +
|-
 +
| 2011-02-25
 +
| Drilling Completion
 +
|-
 +
| 2011-09-07
 +
| Drilling Completion
 +
|-
 +
| 2012-12-12
 +
| NEWLY DRILLED
 +
|-
 +
| 2013-10-09
 +
| FULLY PLUGGED
 
|-
 
|-
 
|}
 
|}
== Inspection Data ==
+
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 1951182
+
|}-->
| 2011-02-16
+
 
| No Violations Noted
+
<!--== Stimulation Data ==
|  
+
{| class="wikitable sortable" width="95%"
|  
+
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 
|-
 
|-
|}
+
|}-->
 +
 
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-2
+
| 2010
| style="text-align:right;" | 0.0
+
| [[EAST RESOURCES MGMT LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2012
| style="text-align:right;" | 0.0
+
| [[SWEPI LP]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[SWEPI LP]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
|}
| style="text-align:right;" | 0.0
+
For data sources see<ref>{{cite web
| style="text-align:right;" | 0.0
+
| title =Oil and Gas Production Reports
| style="text-align:right;" | 0.0
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| style="text-align:right;" | 0.0
+
| date = 2019-03-31
| style="text-align:right;" | 0.0
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
| style="text-align:right;" | 0.0
+
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 
|-
 
|-
 +
|}-->
 +
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
| 2011-1
+
| 1951182
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2011-02-16
| style="text-align:right;" | 0.0
+
| Drilling/Alteration
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2182061
 +
| Primary Facility
 +
| 2013-07-09
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2010-2
+
| 2501812
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2016-07-13
| style="text-align:right;" | 0.0
+
| Site Restoration
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| 2 Marcellus Shale wells on this pad; 1 is plugged.  Recommending approval of NOT.
| style="text-align:right;" | 0.0
+
|-
 +
| 2518358
 +
| Primary Facility
 +
| 2016-09-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Inspection of SWEPI’s Torpy & Van Order Inc 574 pad in Covington Twp, Tioga County conducted September 12, 2016 at approximately 12:00 pm. There were 2 wells on the pad at the time of inspection; the 1V (Plugged 9/7/11) and the 3H (Regulatory Inactive Status). The 1V is plugged and capped off with blanked spool with a needle valve (shut-in) on the cap. The 3H is shut in with a lower master valve and cap atop production casing spool/tubing hanger. The cellar was filled with gravel and there were (4) total vent pipes plumbed to surface coming up through the gravel. There were (2) 2” vent pipes assumed to be backside of the production casing (9 5/8” x 5 ½”) annulus. One of these vent pipes was shut-in, while the other was 90’d downward into a bucket. A field reading with an Altair 5x gas meter placed next to the vent outlet showed 100% LEL 66% Methane. The other (2) remaining smaller vent pipes I assume to be the intermediate csg’s annulus (1 ½” vent) and the surface casing’s annulus (1” vent). No gas was prese
 +
|-
 +
| 2562587
 +
| Primary Facility
 +
| 2017-02-15
 +
| Plugging(Includes Plugged/Mined Through)
 +
| No Violations Noted
 +
| Routine inspection of SWEPI’s Torpy Van Order 574 1V (117-21051) plugged gas well conducted February 15, 2017 at 12:30 pm. At the time of inspection; the well cellar was buried with gravel, ice and water on top; no bubbling. Casinghead and night cap were on the well, above grade. There was a needle valve on the night cap, shut in. I put on a 0-160 PSI gauge and opened the valve; no pressure. I opened the bleeder on my pressure gauge and heard some minimal flow. I checked flow with a ½” pipe nipple and balloon. The balloon inflated, but wasn’t enough flow/pressure to blow up the balloon or blow it off the pipe nipple, even after waiting 5 minutes. Shut the needle valve back in and left location.
 
|-
 
|-
 
|}
 
|}
== Waste Data ==
+
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Violation ID
!scope="col" | TYPE
+
!scope="col" | Penalty ID
!scope="col" | QUANTITY
+
!scope="col" | Penalty Code
!scope="col" | UNITS
+
!scope="col" | Penalty Status
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Penalty Date
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Enforcement Date
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Penalty Amount
!scope="col" | FACILITY CITY
+
!scope="col" | Amount Collected
!scope="col" | FACILITY STATE
+
|-
|}
+
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 01:55, 16 May 2020

Well Details

Well ID: 37-117-21051
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Covington Township
Operator Name: SWEPI LP
Well Pad ID: 149447
Farm/Lease Name: TORPY & VAN ORDER INC 574 1V
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2010-12-07
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.719667
Longitude: -77.120511

For data sources see[1][2][3]

Well History

Date Event
2010-12-07 New Permit Application
2011-01-19 Performed Spud Operation
2011-02-25 Drilling Completion
2011-09-07 Drilling Completion
2012-12-12 NEWLY DRILLED
2013-10-09 FULLY PLUGGED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 0.00 0 0.00 0 0.00 0
2011 SWEPI LP 0.00 0 0.00 0 0.00 0
2012 SWEPI LP 0.00 0 0.00 0 0.00 0
2013 SWEPI LP 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1951182 Primary Facility 2011-02-16 Drilling/Alteration No Violations Noted
2182061 Primary Facility 2013-07-09 Routine/Complete Inspection No Violations Noted
2501812 Primary Facility 2016-07-13 Site Restoration No Violations Noted 2 Marcellus Shale wells on this pad; 1 is plugged. Recommending approval of NOT.
2518358 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted Inspection of SWEPI’s Torpy & Van Order Inc 574 pad in Covington Twp, Tioga County conducted September 12, 2016 at approximately 12:00 pm. There were 2 wells on the pad at the time of inspection; the 1V (Plugged 9/7/11) and the 3H (Regulatory Inactive Status). The 1V is plugged and capped off with blanked spool with a needle valve (shut-in) on the cap. The 3H is shut in with a lower master valve and cap atop production casing spool/tubing hanger. The cellar was filled with gravel and there were (4) total vent pipes plumbed to surface coming up through the gravel. There were (2) 2” vent pipes assumed to be backside of the production casing (9 5/8” x 5 ½”) annulus. One of these vent pipes was shut-in, while the other was 90’d downward into a bucket. A field reading with an Altair 5x gas meter placed next to the vent outlet showed 100% LEL 66% Methane. The other (2) remaining smaller vent pipes I assume to be the intermediate csg’s annulus (1 ½” vent) and the surface casing’s annulus (1” vent). No gas was prese
2562587 Primary Facility 2017-02-15 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of SWEPI’s Torpy Van Order 574 1V (117-21051) plugged gas well conducted February 15, 2017 at 12:30 pm. At the time of inspection; the well cellar was buried with gravel, ice and water on top; no bubbling. Casinghead and night cap were on the well, above grade. There was a needle valve on the night cap, shut in. I put on a 0-160 PSI gauge and opened the valve; no pressure. I opened the bleeder on my pressure gauge and heard some minimal flow. I checked flow with a ½” pipe nipple and balloon. The balloon inflated, but wasn’t enough flow/pressure to blow up the balloon or blow it off the pipe nipple, even after waiting 5 minutes. Shut the needle valve back in and left location.

For data sources see[6]

References