If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-081-20378 | | Well ID: 37-081-20378 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 41.262086, -76.618892 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: KENSINGER UNIT 8H | | Farm/Lease Name: KENSINGER UNIT 8H | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2010-10-15 | | Permit Date: 2010-10-15 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: No | ||
|- | |- | ||
| Latitude: 41.262086 | | Latitude: 41.262086 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2010-10-15 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2011-05-24 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2011-06-20 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2012-03-04 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2012-09-22 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2012-09-28 | ||
+ | | REWORKED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 95: | ||
| 2012-03-04 | | 2012-03-04 | ||
| 2012-03-04 | | 2012-03-04 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,537 |
− | | style="text-align: right;" | 4,469,808 | + | | style="text-align: right;" | 4,469,808 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
|- | |- | ||
Line 222: | Line 255: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 316: | Line 360: | ||
| 2019 | | 2019 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 238,382.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 363 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 341: | Line 385: | ||
| 2011 | | 2011 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
| style="text-align: right;" | 586.20 Bbl | | style="text-align: right;" | 586.20 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 348: | Line 392: | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 2,009.36 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | WMGR119 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 770.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR119 | | WMGR119 | ||
Line 362: | Line 406: | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 657.12 Bbl | | style="text-align: right;" | 657.12 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 369: | Line 413: | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Fracturing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 7.57 Tons |
− | | | + | | LANDFILL |
− | | | + | | 301358 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Drill Cuttings |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 7.25 Tons |
− | | | + | | LANDFILL |
− | | | + | | 301358 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 1,642.00 Bbl |
− | | | + | | STORAGE PENDING DISPOSAL OR REUSE |
− | | | + | | |
|- | |- | ||
| 2013 | | 2013 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 326.18 Bbl | | style="text-align: right;" | 326.18 Bbl | ||
| STORAGE PENDING DISPOSAL OR REUSE | | STORAGE PENDING DISPOSAL OR REUSE | ||
Line 397: | Line 441: | ||
| 2013 | | 2013 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Fracturing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 3.96 Tons |
− | | | + | | LANDFILL |
− | | | + | | 301358 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Drill Cuttings | + | | Drill Cuttings |
| style="text-align: right;" | 1.19 Tons | | style="text-align: right;" | 1.19 Tons | ||
| LANDFILL | | LANDFILL | ||
Line 411: | Line 455: | ||
| 2013 | | 2013 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 242.84 Bbl | | style="text-align: right;" | 242.84 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 418: | Line 462: | ||
| 2013 | | 2013 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 109.50 Bbl |
− | | | + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) |
− | | | + | | WMGR119 |
|- | |- | ||
| 2014 | | 2014 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 432: | Line 476: | ||
| 2014 | | 2014 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 100.10 Bbl | | style="text-align: right;" | 100.10 Bbl | ||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
Line 439: | Line 483: | ||
| 2015 | | 2015 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 446: | Line 490: | ||
| 2016 | | 2016 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 110.00 Bbl | | style="text-align: right;" | 110.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 453: | Line 497: | ||
| 2018 | | 2018 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 150.00 Bbl | | style="text-align: right;" | 150.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 460: | Line 504: | ||
| 2018 | | 2018 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 71.70 Bbl | | style="text-align: right;" | 71.70 Bbl | ||
| RESIDUAL WASTE PROCESSING FACILITY | | RESIDUAL WASTE PROCESSING FACILITY | ||
Line 467: | Line 511: | ||
| 2019 | | 2019 | ||
| [[EXCO RESOURCES PA LLC]] | | [[EXCO RESOURCES PA LLC]] | ||
− | | Produced Fluid ( | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 21.00 Bbl |
+ | | REUSE (AT WELL PAD) | ||
+ | | | ||
+ | |- | ||
+ | | 2019 | ||
+ | | [[EXCO RESOURCES PA LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 54.50 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
| PAS2D205BCLE | | PAS2D205BCLE |
Well ID: 37-081-20378 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.262086,"lon":-76.618892,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 148667 | |
Farm/Lease Name: KENSINGER UNIT 8H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-10-15 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.262086 | |
Longitude: -76.618892 |
Date | Event |
---|---|
2010-10-15 | New Permit Application |
2011-05-24 | Performed Spud Operation |
2011-06-20 | New Permit Application |
2012-03-04 | Perforation |
2012-09-22 | Drilling Completion |
2012-09-28 | REWORKED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-03-04 | 2012-03-04 | 6,537 | 4,469,808 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | DAP-923 | Calfrac Well Services | Acid Corrosion Inhibitor | Methanol | 67-56-1 | 60.00 | 0.00073000 | |
Propargyl Alcohol | 10.00 | 0.00012000 | ||||||
Fatty Acids | 30.00 | 0.00037000 | ||||||
Polyoxyalkylenes | 30.00 | 0.00037000 | ||||||
Thiourea polymer | 68527-49-1 | 30.00 | 0.00037000 | |||||
Olefin | 5.00 | 0.00006000 | ||||||
Water | Base Fluid | Water | 100.00 | 85.42 | ||||
DAP-901 | Calfrac Well Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00186000 | ||
Organic phosphonate | 30.00 | 0.00558000 | ||||||
Methanol | 67-56-1 | 30.00 | 0.00558000 | |||||
Oxyalkylated polyamine | 5.00 | 0.00093000 | ||||||
Phosphoric Acid ammonium salt | 5.00 | 0.00093000 | ||||||
Amine salt | 5.00 | 0.00093000 | ||||||
DWP-612 | Calfrac Well Services | Friction Reducer | No Hazardous Materials | 100.00 | 0.08 | |||
Sand (Proppant) | Calfrac Well Services | Propping Agent | Quartz | 14808-60-7 | 100.00 | 13.74 | ||
DWP-944 | Calfrac Well Services | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 40.00 | 0.01 | ||
Polyethylene glycol | 25322-68-3 | 70.00 | 0.02 | |||||
Hydrochloric Acid | Calfrac Well Services | Acid | Hydrochloric acid | 7647-01-0 | 35.00 | 0.24 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 232,355.00 | 175 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 930,740.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 715,321.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 478,191.00 | 349 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 307,128.00 | 278 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 321,686.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 281,577.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 238,382.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 586.20 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 2,009.36 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 770.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 657.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 7.57 Tons | LANDFILL | 301358 |
2012 | EXCO RESOURCES PA LLC | Drill Cuttings | 7.25 Tons | LANDFILL | 301358 |
2012 | EXCO RESOURCES PA LLC | Fracing Fluid Waste | 1,642.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 326.18 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 3.96 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Drill Cuttings | 1.19 Tons | LANDFILL | 301358 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 242.84 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 109.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 100.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2016 | EXCO RESOURCES PA LLC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 150.00 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2018 | EXCO RESOURCES PA LLC | Produced Fluid | 71.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 21.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 54.50 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1987897 | Primary Facility | 2011-07-14 | Drilling/Alteration | No Violations Noted | |
2003915 | Primary Facility | 2011-09-19 | Drilling/Alteration | No Violations Noted | |
2011495 | Primary Facility | 2011-10-13 | Drilling/Alteration | No Violations Noted | |
2021430 | Primary Facility | 2011-11-22 | Drilling/Alteration | No Violations Noted | |
2022429 | Primary Facility | 2011-11-29 | Routine/Complete Inspection | No Violations Noted | |
2030560 | Primary Facility | 2011-12-29 | Routine/Complete Inspection | No Violations Noted | |
2034692 | Primary Facility | 2012-01-12 | Routine/Complete Inspection | No Violations Noted | |
2056711 | Primary Facility | 2012-04-02 | Routine/Partial Inspection | No Violations Noted | |
2056871 | Primary Facility | 2012-04-05 | Routine/Complete Inspection | No Violations Noted | |
2065777 | Primary Facility | 2012-05-07 | Routine/Complete Inspection | No Violations Noted | |
2072715 | Primary Facility | 2012-06-01 | Drilling/Alteration | No Violations Noted | |
2076751 | Primary Facility | 2012-06-12 | Routine/Complete Inspection | No Violations Noted | |
2077318 | Primary Facility | 2012-06-14 | Routine/Complete Inspection | No Violations Noted | |
2081829 | Primary Facility | 2012-07-06 | Incident- Response to Accident or Event | No Violations Noted | |
2092484 | Primary Facility | 2012-08-15 | Routine/Complete Inspection | No Violations Noted | |
2094157 | Primary Facility | 2012-08-23 | Routine/Partial Inspection | No Violations Noted | |
2104856 | Primary Facility | 2012-09-27 | Routine/Complete Inspection | No Violations Noted | |
2148025 | Primary Facility | 2013-03-12 | Routine/Complete Inspection | No Violations Noted | |
2433757 | Primary Facility | 2015-12-14 | Routine/Complete Inspection | No Violations Noted | Kensinger 8H |
2478323 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, the Kensinger Unit 3H (081-20255), 6H (081-20388), 7H (08-20377), 8H (081-20378), 9H (081-20379), 10H (081-20380), and 11H (081-20381) wells were all in production. The well site remains at its original size and has not been restored. The Well Site Compliance Information Request reply (submitted 9/21/2015) states the well pad was reclaimed and the NOT will be submitted in 9/2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 2010. According to the Department’s records, the wells onsite were drilled in 2010 and 2011 and completed in 2010 and 2012. The well pad remains at its original size although aerial photos indicate a pit was located onsite that has since been closed. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and is part of a larger disturbance. |
2550516 | Primary Facility | 2017-01-05 | Routine/Complete Inspection | No Violations Noted | Kensinger 8H, Gravel-filled cellar, no combustible gas detected, top gauge: 328 psi. |
2563547 | Primary Facility | 2017-02-15 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 2/15/2017.
The inspection was prompted when Bird Smith called on 2/13/2017 to report a produced water leak. According to the call, approximately 12 barrels of produced water leaked from the Kensinger Unit 3H (081-20255) production tank into containment due to a frozen pipe. Ice was covering the bottom of the containment at the time of the release. At the time of the inspection, seven wells (081-20255, 081-20388, 081-20377, 081-20378, 081-20379, 081-20380, 081-20381) were in production. Field conductivity was 1,500 umhos/cm in containment on top of the ice just under the leak. Under the ice, the water was 120 umhos/cm. The area around the containment was frozen with snow but no evidence was found to suggest produced water left containment. On 12/21/2016, the Department issued an ESCGP for this site for the first time. I recommend implementing the PCSM/restoration plans for the site as soon as possible. No Violations Noted. |
2799192 | Primary Facility | 2018-11-06 | Routine/Complete Inspection | No Violations Noted | Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. No violations noted. |
For data sources see[8]