X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-081-20381"

m
m
 
(13 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 081-20381
+
| Well ID: 37-081-20381
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.262119, -76.618794 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.262119, -76.618794 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 
|-
 
|-
| County: [[Lycoming County, Pennsylvania|Lycoming]]
+
| County: [[Lycoming_County,_Pennsylvania|Lycoming]]
 
|-
 
|-
| Municipality: [[Penn Township, Lycoming County, Pennsylvania|Penn Township]]
+
| Municipality: [[Penn Township,_Lycoming_County,_Pennsylvania|Penn Township]]
 
|-
 
|-
| Operator Name: [[EXCO RESOURCES PA LLC|EXCO RESOURCES PA LLC]]
+
| Operator Name: [[EXCO RESOURCES PA LLC]]
 +
|-
 +
| Well Pad ID: [[148667]]
 
|-
 
|-
 
| Farm/Lease Name: KENSINGER UNIT 11H
 
| Farm/Lease Name: KENSINGER UNIT 11H
 
|-
 
|-
| First Permit Date: 2010-10-15
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2011-06-28
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2011-05-24
+
| Permit Date: 2010-10-15
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 1
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.262119
 
| Latitude: 41.262119
 
|-
 
|-
 
| Longitude: -76.618794
 
| Longitude: -76.618794
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2010-10-15
 +
| New Permit Application
 +
|-
 +
| 2011-05-24
 +
| Performed Spud Operation
 +
|-
 +
| 2011-06-28
 +
| New Permit Application
 +
|-
 +
| 2011-11-13
 +
| Drilling Completion
 +
|-
 +
| 2012-03-20
 +
| Perforation
 +
|-
 +
| 2012-09-28
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2012-03-20
 +
| 2012-03-20
 +
| style="text-align: right;" | 7,009
 +
| style="text-align: right;" | 3,084,708
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="18"| 1
 +
| rowspan="1"| Sand (Proppant)
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Propping Agent
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 16.26
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="6"| DAP-901
 +
| rowspan="6"| Calfrac Well Services
 +
| rowspan="6"| Scale Inhibitor
 +
| Oxyalkylated polyamine
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00093000
 +
| style="text-align: right;" |
 +
|-
 +
| Amine salt
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00093000
 +
| style="text-align: right;" |
 +
|-
 +
| Phosphoric Acid ammonium salt
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00093000
 +
| style="text-align: right;" |
 +
|-
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00186000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00557000
 +
| style="text-align: right;" |
 +
|-
 +
| Organic phosphonate
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00557000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"|
 +
| rowspan="1"| Base Fluid
 +
| Water
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 82.77
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| DWP-944
 +
| rowspan="2"| Calfrac Well Services
 +
| rowspan="2"| Biocide
 +
| Polyethylene glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 70.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="6"| DAP-923
 +
| rowspan="6"| Calfrac Well Services
 +
| rowspan="6"| Acid Corrosion Inhibitor
 +
| Olefin
 +
|
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| Fatty Acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00043000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl Alcohol
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00014000
 +
| style="text-align: right;" |
 +
|-
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00085000
 +
| style="text-align: right;" |
 +
|-
 +
| Thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00043000
 +
| style="text-align: right;" |
 +
|-
 +
| Polyoxyalkylenes
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00043000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| DWP-612
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Friction Reducer
 +
| No Hazardous Materials
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.08
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Hydrochloric Acid
 +
| rowspan="1"| Calfrac Well Services
 +
| rowspan="1"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 35.00
 +
| style="text-align: right;" | 0.28
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2010
 +
| [[CHIEF OIL & GAS LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2011
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 218,365.00
 +
| style="text-align: right;" | 175
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 623,700.00
 +
| style="text-align: right;" | 351
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 605,955.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 487,396.00
 +
| style="text-align: right;" | 349
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2016
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 312,733.00
 +
| style="text-align: right;" | 275
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2017
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 356,681.00
 +
| style="text-align: right;" | 337
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2018
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 332,464.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 288,892.00
 +
| style="text-align: right;" | 363
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 +
|-
 +
| 2011
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 238.10 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0101508
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 3,557.70 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR119
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 590.42 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 30.72 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 71.95 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 109.52 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 440.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR119
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 1,310.00 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 438.08 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC009
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 219.04 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NC024
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 723.79 Bbl
 +
| STORAGE PENDING DISPOSAL OR REUSE
 +
|
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 3.97 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 1.19 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 547.60 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR119
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 547.54 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 54.80 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC024
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 99.70 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2015
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2015
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 55.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2017
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 100.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2018
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 200.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 31.60 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 283.90 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Well Inspection Data ==
+
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 
| 1987900
 
| 1987900
 +
| Primary Facility
 
| 2011-07-14
 
| 2011-07-14
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2011506
 
| 2011506
 +
| Primary Facility
 
| 2011-10-13
 
| 2011-10-13
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2021433
 
| 2021433
 +
| Primary Facility
 
| 2011-11-22
 
| 2011-11-22
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2022432
 
| 2022432
 +
| Primary Facility
 
| 2011-11-29
 
| 2011-11-29
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2030567
 
| 2030567
 +
| Primary Facility
 
| 2011-12-29
 
| 2011-12-29
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2034707
 
| 2034707
 +
| Primary Facility
 
| 2012-01-12
 
| 2012-01-12
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2056866
 
| 2056866
 +
| Primary Facility
 
| 2012-04-05
 
| 2012-04-05
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2065783
 
| 2065783
 +
| Primary Facility
 
| 2012-05-07
 
| 2012-05-07
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2072704
 
| 2072704
 +
| Primary Facility
 
| 2012-06-01
 
| 2012-06-01
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2076756
 
| 2076756
 +
| Primary Facility
 
| 2012-06-12
 
| 2012-06-12
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2077321
 
| 2077321
 +
| Primary Facility
 
| 2012-06-14
 
| 2012-06-14
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2081834
 
| 2081834
 +
| Primary Facility
 
| 2012-07-06
 
| 2012-07-06
 +
| Incident- Response to Accident or Event
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2092488
 
| 2092488
 +
| Primary Facility
 
| 2012-08-15
 
| 2012-08-15
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2094160
 
| 2094160
 +
| Primary Facility
 
| 2012-08-23
 
| 2012-08-23
 +
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2102370
 
| 2102370
 +
| Primary Facility
 
| 2012-09-06
 
| 2012-09-06
 +
| Administrative/File Review
 
| Viol(s) Noted &  Immediately Corrected
 
| Viol(s) Noted &  Immediately Corrected
 
|  
 
|  
| 649956
 
|-
 
 
|-
 
|-
 
| 2104862
 
| 2104862
 +
| Primary Facility
 
| 2012-09-27
 
| 2012-09-27
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2148028
 +
| Primary Facility
 +
| 2013-03-12
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
|}
+
| 2433765
== Production Data ==
+
| Primary Facility
{| class="wikitable sortable" width="95%"
+
| 2015-12-14
!scope="col" | PERIOD
+
| Routine/Complete Inspection
!scope="col" | GAS QUANTITY
+
| No Violations Noted
!scope="col" | GAS PRODUCTION DAYS
+
| Kensinger 11H
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2478327
| style="text-align:right;" | 214161.0
+
| Primary Facility
| style="text-align:right;" | 151.0
+
| 2016-04-19
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| At the time of the inspection, the Kensinger Unit 3H (081-20255), 6H (081-20388), 7H (08-20377), 8H (081-20378), 9H (081-20379), 10H (081-20380), and 11H (081-20381) wells were all in production.  The well site remains at its original size and has not been restored.  The Well Site Compliance Information Request reply (submitted 9/21/2015) states the well pad was reclaimed and the NOT will be submitted in 9/2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 2010.  According to the Department’s records, the wells onsite were drilled in 2010 and 2011 and completed in 2010 and 2012. The well pad remains at its original size although aerial photos indicate a pit was located onsite that has since been closed. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and is part of a larger disturbance.
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2550520
 +
| Primary Facility
 +
| 2017-01-05
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Kensinger 11H, Gravel-filled cellar, 9-5/8” x 5-1/2” annulus: 6% combustible gas/volume,
 +
top gauge: 445 psi.
 
|-
 
|-
| 2012-1
+
| 2563553
| style="text-align:right;" | 4204.0
+
| Primary Facility
| style="text-align:right;" | 24.0
+
| 2017-02-15
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| Routine Inspection; 2/15/2017.
| style="text-align:right;" | 0.0
+
The inspection was prompted when Bird Smith called on 2/13/2017 to report a produced water leak.  According to the call, approximately 12 barrels of produced water leaked from the Kensinger Unit 3H (081-20255) production tank into containment due to a frozen pipe.  Ice was covering the bottom of the containment at the time of the release. At the time of the inspection, seven wells (081-20255, 081-20388, 081-20377, 081-20378, 081-20379, 081-20380, 081-20381) were in production.  Field conductivity was 1,500 umhos/cm in containment on top of the ice just under the leak.  Under the ice, the water was 120 umhos/cm.  The area around the containment was frozen with snow but no evidence was found to suggest produced water left containment.  On 12/21/2016, the Department issued an ESCGP for this site for the first time.  I recommend implementing the PCSM/restoration plans for the site as soon as possible.  No Violations Noted.
 
|-
 
|-
 +
| 2799209
 +
| Primary Facility
 +
| 2018-11-06
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. No violations noted.
 
|-
 
|-
| 2011-2
+
|}
| style="text-align:right;" | 0.0
+
==== Violations Commited ====
| style="text-align:right;" | 0.0
+
{| class="wikitable sortable" width="95%"
| style="text-align:right;" | 0.0
+
!scope="col" | Inspection ID
| style="text-align:right;" | 0.0
+
!scope="col" | Violation ID
| style="text-align:right;" | 0.0
+
!scope="col" | Violation Date
| style="text-align:right;" | 0.0
+
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
|-
+
| 2102370
| 2011-1
+
| 649956
| style="text-align:right;" | 0.0
+
| 09/06/2012
| style="text-align:right;" | 0.0
+
| 2012-09-06
| style="text-align:right;" | 0.0
+
| 78.122 - Drillers Log not on site
| style="text-align:right;" | 0.0
+
| Administrative
| style="text-align:right;" | 0.0
+
| overdue well records
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2011-1
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2010-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
== Waste Data ==
+
==== Penalties Applied ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Violation ID
!scope="col" | TYPE
+
!scope="col" | Penalty ID
!scope="col" | QUANTITY
+
!scope="col" | Penalty Code
!scope="col" | UNITS
+
!scope="col" | Penalty Status
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Penalty Date
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Enforcement Date
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Penalty Amount
!scope="col" | FACILITY CITY
+
!scope="col" | Amount Collected
!scope="col" | FACILITY STATE
 
|-
 
| 2012-2
 
| PRODUCED FLUID
 
| style="text-align:right;" | 2355.16
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
| EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT)
 
| WILLIAMSPORT
 
| PA
 
 
|-
 
|-
|-
+
| 649956
| 2012-2
+
| 288863
| PRODUCED FLUID
+
| CACP - Consent Assessment of Civil Penalty
| style="text-align:right;" | 590.42
+
| Comply/Closed
| Bbl
+
| 2012-09-24
| REUSE OTHER THAN ROAD SPREADING
+
| 2012-09-24
|
+
| style="text-align: right;" | $12,500.00
| REUSE FOR HYDRAULIC FRACTURING
+
| style="text-align: right;" | $12,500.00
|
 
|  
 
|-
 
|-
 
| 2012-2
 
| PRODUCED FLUID
 
| style="text-align:right;" | 109.52
 
| Bbl
 
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
| PA
 
|-
 
|-
 
| 2011-2
 
| DRILLING FLUID WASTE
 
| style="text-align:right;" | 238.1
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| PA0101508
 
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
|-
 
|-
 
| 2012-1
 
| FRACING FLUID WASTE
 
| style="text-align:right;" | 440.0
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
| EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT)
 
| WILLIAMSPORT
 
| PA
 
|-
 
|-
 
| 2012-1
 
| PRODUCED FLUID
 
| style="text-align:right;" | 1202.54
 
| Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
| EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT)
 
| WILLIAMSPORT
 
| PA
 
|-
 
|-
 
| 2012-1
 
| DRILL CUTTINGS
 
| style="text-align:right;" | 71.95
 
| Tons
 
| LANDFILL
 
| 743884
 
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
|-
 
|-
 
| 2012-1
 
| FLOWBACK FRACTURING SAND
 
| style="text-align:right;" | 30.72
 
| Tons
 
| LANDFILL
 
| 743884
 
| PHOENIX RESOURCES LANDFILL
 
| WELLSBORO
 
| PA
 
|-
 
|-
 
| 2012-1
 
| FRACING FLUID WASTE
 
| style="text-align:right;" | 1310.0
 
| Bbl
 
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
| STORAGE PENDING DISPOSAL OR REUSE
 
|
 
| PA
 
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 23:52, 16 May 2020

Well Details

Well ID: 37-081-20381
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148667
Farm/Lease Name: KENSINGER UNIT 11H
License Status:
Spud Date:
Permit Date: 2010-10-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.262119
Longitude: -76.618794

For data sources see[1][2][3]

Well History

Date Event
2010-10-15 New Permit Application
2011-05-24 Performed Spud Operation
2011-06-28 New Permit Application
2011-11-13 Drilling Completion
2012-03-20 Perforation
2012-09-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-20 2012-03-20 7,009 3,084,708

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Calfrac Well Services Propping Agent Quartz 14808-60-7 100.00 16.26
DAP-901 Calfrac Well Services Scale Inhibitor Oxyalkylated polyamine 5.00 0.00093000
Amine salt 5.00 0.00093000
Phosphoric Acid ammonium salt 5.00 0.00093000
Ammonium chloride 12125-02-9 10.00 0.00186000
Methanol 67-56-1 30.00 0.00557000
Organic phosphonate 30.00 0.00557000
Water Base Fluid Water 100.00 82.77
DWP-944 Calfrac Well Services Biocide Polyethylene glycol 25322-68-3 70.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
DAP-923 Calfrac Well Services Acid Corrosion Inhibitor Olefin 5.00 0.00007000
Fatty Acids 30.00 0.00043000
Propargyl Alcohol 10.00 0.00014000
Methanol 67-56-1 60.00 0.00085000
Thiourea polymer 68527-49-1 30.00 0.00043000
Polyoxyalkylenes 30.00 0.00043000
DWP-612 Calfrac Well Services Friction Reducer No Hazardous Materials 100.00 0.08
Hydrochloric Acid Calfrac Well Services Acid Hydrochloric acid 7647-01-0 35.00 0.28

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 218,365.00 175 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 623,700.00 351 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 605,955.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 487,396.00 349 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 312,733.00 275 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 356,681.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 332,464.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 288,892.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 238.10 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 EXCO RESOURCES PA LLC Produced Fluid 3,557.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 590.42 Bbl REUSE OTHER THAN ROAD SPREADING
2012 EXCO RESOURCES PA LLC Fracturing Fluid Waste 30.72 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Drill Cuttings 71.95 Tons LANDFILL 301358
2012 EXCO RESOURCES PA LLC Produced Fluid 109.52 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 440.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 1,310.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 438.08 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid 219.04 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013 EXCO RESOURCES PA LLC Produced Fluid 723.79 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 3.97 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Drill Cuttings 1.19 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid 547.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 547.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 54.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 99.70 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 55.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 200.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 31.60 Bbl REUSE (AT WELL PAD)
2019 EXCO RESOURCES PA LLC Produced Fluid 283.90 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1987900 Primary Facility 2011-07-14 Drilling/Alteration No Violations Noted
2011506 Primary Facility 2011-10-13 Drilling/Alteration No Violations Noted
2021433 Primary Facility 2011-11-22 Drilling/Alteration No Violations Noted
2022432 Primary Facility 2011-11-29 Routine/Complete Inspection No Violations Noted
2030567 Primary Facility 2011-12-29 Routine/Complete Inspection No Violations Noted
2034707 Primary Facility 2012-01-12 Routine/Complete Inspection No Violations Noted
2056866 Primary Facility 2012-04-05 Routine/Complete Inspection No Violations Noted
2065783 Primary Facility 2012-05-07 Routine/Complete Inspection No Violations Noted
2072704 Primary Facility 2012-06-01 Drilling/Alteration No Violations Noted
2076756 Primary Facility 2012-06-12 Routine/Complete Inspection No Violations Noted
2077321 Primary Facility 2012-06-14 Routine/Complete Inspection No Violations Noted
2081834 Primary Facility 2012-07-06 Incident- Response to Accident or Event No Violations Noted
2092488 Primary Facility 2012-08-15 Routine/Complete Inspection No Violations Noted
2094160 Primary Facility 2012-08-23 Routine/Partial Inspection No Violations Noted
2102370 Primary Facility 2012-09-06 Administrative/File Review Viol(s) Noted & Immediately Corrected
2104862 Primary Facility 2012-09-27 Routine/Complete Inspection No Violations Noted
2148028 Primary Facility 2013-03-12 Routine/Complete Inspection No Violations Noted
2433765 Primary Facility 2015-12-14 Routine/Complete Inspection No Violations Noted Kensinger 11H
2478327 Primary Facility 2016-04-19 Routine/Complete Inspection No Violations Noted At the time of the inspection, the Kensinger Unit 3H (081-20255), 6H (081-20388), 7H (08-20377), 8H (081-20378), 9H (081-20379), 10H (081-20380), and 11H (081-20381) wells were all in production. The well site remains at its original size and has not been restored. The Well Site Compliance Information Request reply (submitted 9/21/2015) states the well pad was reclaimed and the NOT will be submitted in 9/2015. The Department has no record of an ESCGP issued for the site and no well permits have been issued for the site since 2010. According to the Department’s records, the wells onsite were drilled in 2010 and 2011 and completed in 2010 and 2012. The well pad remains at its original size although aerial photos indicate a pit was located onsite that has since been closed. I recommend you apply for an ESCGP-2 to cover this since it has not been restored and is part of a larger disturbance.
2550520 Primary Facility 2017-01-05 Routine/Complete Inspection No Violations Noted Kensinger 11H, Gravel-filled cellar, 9-5/8” x 5-1/2” annulus: 6% combustible gas/volume,

top gauge: 445 psi.

2563553 Primary Facility 2017-02-15 Routine/Complete Inspection No Violations Noted Routine Inspection; 2/15/2017.

The inspection was prompted when Bird Smith called on 2/13/2017 to report a produced water leak. According to the call, approximately 12 barrels of produced water leaked from the Kensinger Unit 3H (081-20255) production tank into containment due to a frozen pipe. Ice was covering the bottom of the containment at the time of the release. At the time of the inspection, seven wells (081-20255, 081-20388, 081-20377, 081-20378, 081-20379, 081-20380, 081-20381) were in production. Field conductivity was 1,500 umhos/cm in containment on top of the ice just under the leak. Under the ice, the water was 120 umhos/cm. The area around the containment was frozen with snow but no evidence was found to suggest produced water left containment. On 12/21/2016, the Department issued an ESCGP for this site for the first time. I recommend implementing the PCSM/restoration plans for the site as soon as possible. No Violations Noted.

2799209 Primary Facility 2018-11-06 Routine/Complete Inspection No Violations Noted Seven wells staged for production phase. Seven each water separators. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2102370 649956 09/06/2012 2012-09-06 78.122 - Drillers Log not on site Administrative overdue well records

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
649956 288863 CACP - Consent Assessment of Civil Penalty Comply/Closed 2012-09-24 2012-09-24 $12,500.00 $12,500.00

For data sources see[8]