X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-081-20717"

m
m
 
(10 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 42-081-20717
+
| Well ID: 37-081-20717
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.283697, -76.589688 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.283697, -76.589689 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 
|-
 
|-
| County: [[Lycoming County, Pennsylvania|Lycoming]]
+
| County: [[Lycoming_County,_Pennsylvania|Lycoming]]
 
|-
 
|-
| Municipality: [[Penn Township, Lycoming County, Pennsylvania|Penn Township]]
+
| Municipality: [[Penn Township,_Lycoming_County,_Pennsylvania|Penn Township]]
 
|-
 
|-
| Operator Name: [[EXCO RESOURCES PA LLC|EXCO RESOURCES PA LLC]]
+
| Operator Name: [[EXCO RESOURCES PA LLC]]
 +
|-
 +
| Well Pad ID: [[148239]]
 
|-
 
|-
 
| Farm/Lease Name: DOEBLER UNIT 2H
 
| Farm/Lease Name: DOEBLER UNIT 2H
 
|-
 
|-
| First Permit Date: 2011-10-17
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2011-10-17
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2011-11-09
+
| Permit Date: 2011-10-17
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: None
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.283697
 
| Latitude: 41.283697
 
|-
 
|-
| Longitude: -76.589688
+
| Longitude: -76.589689
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2011-10-17
 +
| New Permit Application
 +
|-
 +
| 2011-11-09
 +
| Performed Spud Operation
 +
|-
 +
| 2013-01-21
 +
| Drilling Completion
 +
|-
 +
| 2013-08-07
 +
| Perforation
 +
|-
 +
| 2014-03-14
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2013-08-07
 +
| 2013-08-28
 +
| style="text-align: right;" | 7,297
 +
| style="text-align: right;" | 3,860,010
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="10"| 1
 +
| rowspan="1"| Water
 +
| rowspan="1"| Operator
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 84.7562
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FR-66
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Friction Reducer
 +
| Hydrotreated light petroleum distaillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.02749
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Scalechek LP-65 Scale Inhibitor
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Scale Inhabitor
 +
| Ammonium chloride
 +
| 12125-02-9
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.00195
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| LCA-1
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Solvent
 +
| Paraffinic solvent
 +
| Proprietary
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 0.00214
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| SAND-PREMIUM WHITE
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 12.3767
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| SSA-2
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica, quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 2.10025
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| BE-9
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Biocide
 +
| Tributyl tetradecyl phosphonium chloride
 +
| 81741-28-8
 +
| style="text-align: right;" | 30
 +
| style="text-align: right;" | 0.02749
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FE ACID-<10% HCL
 +
| rowspan="1"| Halliburton
 +
| rowspan="1"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.0633
 +
| style="text-align: right;" | 0
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| HAI-OS ACID INHIBITOR
 +
| rowspan="2"| Halliburton
 +
| rowspan="2"| Corrosion Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00061
 +
| style="text-align: right;" | 0
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10
 +
| style="text-align: right;" | 0.0001
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2011
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 1,016,984.00
 +
| style="text-align: right;" | 360
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2015
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 715,080.00
 +
| style="text-align: right;" | 349
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2016
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 472,654.00
 +
| style="text-align: right;" | 277
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2017
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 510,103.00
 +
| style="text-align: right;" | 337
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2018
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 469,139.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| style="text-align: right;" | 415,876.00
 +
| style="text-align: right;" | 363
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 +
|-
 +
| 2012
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 623.44 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 350.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NC024
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 689.26 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NC024
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,459.10 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 5,800.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 534.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 29.50 Tons
 +
| LANDFILL
 +
| 301358
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 54.76 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2013
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,095.68 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC009
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 220.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR119
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 219.10 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC024
 +
|-
 +
| 2014
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 439.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC010
 +
|-
 +
| 2015
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2016
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 110.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 +
|-
 +
| 2016
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 165.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2017
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 155.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2018
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 40.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2018
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 122.90 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 235.80 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D205BCLE
 +
|-
 +
| 2019
 +
| [[EXCO RESOURCES PA LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 25.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Inspection ID
!scope="col" | DATE
+
!scope="col" | Inspection Category
!scope="col" | DESCRIPTION
+
!scope="col" | Inspection Date
!scope="col" | COMMENT
+
!scope="col" | Inspection Type
!scope="col" | VIOLATION ID
+
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 
| 2012633
 
| 2012633
 +
| Primary Facility
 
| 2011-10-20
 
| 2011-10-20
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2034062
 
| 2034062
 +
| Primary Facility
 
| 2012-01-12
 
| 2012-01-12
 +
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2062926
 
| 2062926
 +
| Primary Facility
 
| 2012-04-25
 
| 2012-04-25
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2067471
 
| 2067471
 +
| Primary Facility
 
| 2012-05-11
 
| 2012-05-11
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2077297
 
| 2077297
 +
| Primary Facility
 
| 2012-06-14
 
| 2012-06-14
 +
| Follow-up Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2092261
 
| 2092261
 +
| Primary Facility
 
| 2012-08-16
 
| 2012-08-16
 +
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2098767
 
| 2098767
 +
| Primary Facility
 
| 2012-09-11
 
| 2012-09-11
 +
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2098794
 
| 2098794
 +
| Primary Facility
 
| 2012-09-05
 
| 2012-09-05
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
|
 
 
|  
 
|  
|-
 
 
|-
 
|-
 
| 2117182
 
| 2117182
 +
| Primary Facility
 
| 2012-11-20
 
| 2012-11-20
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2123226
 
| 2123226
 +
| Primary Facility
 
| 2012-12-06
 
| 2012-12-06
 +
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
|
 
|-
 
 
|-
 
|-
 
| 2125968
 
| 2125968
 +
| Primary Facility
 
| 2012-12-21
 
| 2012-12-21
 +
| Complaint Inspection
 
| No Violations Noted
 
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2151239
 +
| Primary Facility
 +
| 2013-03-27
 +
| Drilling/Alteration
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
|}
+
| 2198891
== Production Data ==
+
| Primary Facility
{| class="wikitable sortable" width="95%"
+
| 2013-08-26
!scope="col" | PERIOD
+
| Routine/Complete Inspection
!scope="col" | GAS QUANTITY
+
| No Violations Noted
!scope="col" | GAS PRODUCTION DAYS
+
|  
!scope="col" | CONDENSATE QUANTITY
 
!scope="col" | CONDENSATE PRODUCTION DAYS
 
!scope="col" | OIL QUANTITY
 
!scope="col" | OIL PRODUCTION DAYS
 
 
|-
 
|-
| 2012-2
+
| 2575309
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2017-03-20
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| I entered the site at 09:40, in response to a spill notification phone call I received from Bird Smith (EXCO) at 08:20 this morning. Mr. Smith reported that
| style="text-align:right;" | 0.0
+
approximately 56 barrels of produced water were released to containment from the bottom valve on the Doebler 3H (081-20718) produced water tank. The
 +
release was caused when the produced water froze in the valve and dislodged the gasket. At the time of the inspection, the Doebler 1-5H (081-20454, 081-
 +
20717, 081-20718, 081-20719, 081-20720) wells were in production. Water was actively leaking from the bottom valve on the production tank for the Doebler
 +
3H well but the vac-truck driver/operator was onsite vacuuming water from the containment. Snow was covering the ground around the containment and I
 +
found no evidence that any produced water had leaked out of the containment. Field conductivity of produced water in the containment was between 1650-
 +
1995 umhos/cm at several locations. The conductivity of the produced water is significantly lower than expecte
 
|-
 
|-
 +
| 2800849
 +
| Primary Facility
 +
| 2018-11-08
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Five wells staged for production phase. Five each water separators.  No leaks detected from production equipment. No violations noted.
 
|-
 
|-
| 2012-1
+
| 2845618
| style="text-align:right;" | 0.0
+
| Primary Facility
| style="text-align:right;" | 0.0
+
| 2019-02-27
| style="text-align:right;" | 0.0
+
| Routine/Complete Inspection
| style="text-align:right;" | 0.0
+
| No Violations Noted
| style="text-align:right;" | 0.0
+
| Five wells staged for production phase. Five each water separators. No leaks detected from production equipment. No violations noted.
| style="text-align:right;" | 0.0
 
|-
 
|-
 
| 2011-2
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 
|}
 
|}
== Waste Data ==
+
<!--==== Violations Commited ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Inspection ID
!scope="col" | TYPE
+
!scope="col" | Violation ID
!scope="col" | QUANTITY
+
!scope="col" | Violation Date
!scope="col" | UNITS
+
!scope="col" | Date Resolved
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Violation Code
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Violation Type
!scope="col" | WASTE FACILITY NAME
+
!scope="col" | Violation Comments
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-1
+
|}-->
| DRILL CUTTINGS
+
<!--==== Penalties Applied ====
| style="text-align:right;" | 623.44
+
{| class="wikitable sortable" width="95%"
| Tons
+
!scope="col" | Violation ID
| LANDFILL
+
!scope="col" | Penalty ID
| 743884
+
!scope="col" | Penalty Code
| PHOENIX RESOURCES LANDFILL
+
!scope="col" | Penalty Status
| WELLSBORO
+
!scope="col" | Penalty Date
| PA
+
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
|}
+
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 00:37, 17 May 2020

Well Details

Well ID: 37-081-20717
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148239
Farm/Lease Name: DOEBLER UNIT 2H
License Status:
Spud Date:
Permit Date: 2011-10-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.283697
Longitude: -76.589689

For data sources see[1][2][3]

Well History

Date Event
2011-10-17 New Permit Application
2011-11-09 Performed Spud Operation
2013-01-21 Drilling Completion
2013-08-07 Perforation
2014-03-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-08-07 2013-08-28 7,297 3,860,010

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Operator Carrier/Base Fluid Water 7732-18-5 100 84.7562 0
FR-66 Halliburton Friction Reducer Hydrotreated light petroleum distaillate 64742-47-8 30 0.02749 0
Scalechek LP-65 Scale Inhibitor Halliburton Scale Inhabitor Ammonium chloride 12125-02-9 10 0.00195 0
LCA-1 Halliburton Solvent Paraffinic solvent Proprietary 100 0.00214 0
SAND-PREMIUM WHITE Halliburton Proppant Crystalline Silica, quartz 14808-60-7 100 12.3767 0
SSA-2 Halliburton Proppant Crystalline Silica, quartz 14808-60-7 100 2.10025 0
BE-9 Halliburton Biocide Tributyl tetradecyl phosphonium chloride 81741-28-8 30 0.02749 0
FE ACID-<10% HCL Halliburton Acid Hydrochloric acid 7647-01-0 10 0.0633 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Methanol 67-56-1 60 0.00061 0
Propargyl alcohol 107-19-7 10 0.0001 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 1,016,984.00 360 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 715,080.00 349 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 472,654.00 277 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 510,103.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 469,139.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 415,876.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EXCO RESOURCES PA LLC Drill Cuttings 623.44 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 350.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013 EXCO RESOURCES PA LLC Produced Fluid 689.26 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013 EXCO RESOURCES PA LLC Produced Fluid 1,459.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 5,800.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 534.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 29.50 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid 54.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 EXCO RESOURCES PA LLC Produced Fluid 1,095.68 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2014 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 219.10 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 439.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 EXCO RESOURCES PA LLC Produced Fluid 165.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 155.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 40.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 122.90 Bbl REUSE (AT WELL PAD)
2019 EXCO RESOURCES PA LLC Produced Fluid 235.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 25.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2012633 Primary Facility 2011-10-20 Drilling/Alteration No Violations Noted
2034062 Primary Facility 2012-01-12 Drilling/Alteration No Violations Noted
2062926 Primary Facility 2012-04-25 Routine/Complete Inspection No Violations Noted
2067471 Primary Facility 2012-05-11 Routine/Complete Inspection No Violations Noted
2077297 Primary Facility 2012-06-14 Follow-up Inspection No Violations Noted
2092261 Primary Facility 2012-08-16 Routine/Partial Inspection No Violations Noted
2098767 Primary Facility 2012-09-11 Routine/Partial Inspection No Violations Noted
2098794 Primary Facility 2012-09-05 Routine/Complete Inspection No Violations Noted
2117182 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2123226 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted
2125968 Primary Facility 2012-12-21 Complaint Inspection No Violations Noted
2151239 Primary Facility 2013-03-27 Drilling/Alteration No Violations Noted
2198891 Primary Facility 2013-08-26 Routine/Complete Inspection No Violations Noted
2575309 Primary Facility 2017-03-20 Routine/Complete Inspection No Violations Noted I entered the site at 09:40, in response to a spill notification phone call I received from Bird Smith (EXCO) at 08:20 this morning. Mr. Smith reported that

approximately 56 barrels of produced water were released to containment from the bottom valve on the Doebler 3H (081-20718) produced water tank. The release was caused when the produced water froze in the valve and dislodged the gasket. At the time of the inspection, the Doebler 1-5H (081-20454, 081- 20717, 081-20718, 081-20719, 081-20720) wells were in production. Water was actively leaking from the bottom valve on the production tank for the Doebler 3H well but the vac-truck driver/operator was onsite vacuuming water from the containment. Snow was covering the ground around the containment and I found no evidence that any produced water had leaked out of the containment. Field conductivity of produced water in the containment was between 1650- 1995 umhos/cm at several locations. The conductivity of the produced water is significantly lower than expecte

2800849 Primary Facility 2018-11-08 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. Five each water separators. No leaks detected from production equipment. No violations noted.
2845618 Primary Facility 2019-02-27 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. Five each water separators. No leaks detected from production equipment. No violations noted.

For data sources see[8]

References