{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-003-22145 | | Well ID: 37-003-22145 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.558072, -79.850550 | width=100% | height=100% }} |
|- | |- | ||
− | | | + | | Country: United States |
|- | |- | ||
− | | Municipality: [[Harmar Township, | + | | State: Pennsylvania |
+ | |- | ||
+ | | County: [[Allegheny_County,_Pennsylvania|Allegheny]] | ||
+ | |- | ||
+ | | Municipality: [[Harmar Township,_Allegheny_County,_Pennsylvania|Harmar Township]] | ||
|- | |- | ||
| Operator Name: [[MARCO DRILLING INC]] | | Operator Name: [[MARCO DRILLING INC]] | ||
Line 15: | Line 19: | ||
| Farm/Lease Name: DFGT PROPERTIES LLC 1-6 | | Farm/Lease Name: DFGT PROPERTIES LLC 1-6 | ||
|- | |- | ||
− | | | + | | License Status: |
|- | |- | ||
− | | | + | | Spud Date: |
|- | |- | ||
− | | | + | | Permit Date: 2010-10-13 |
|- | |- | ||
− | | | + | | Well Type: GAS |
|- | |- | ||
− | | | + | | Unconventional Well: N |
|- | |- | ||
− | | Well | + | | Configuration: Vertical Well |
|- | |- | ||
− | | | + | | Conservation: No |
|- | |- | ||
| Latitude: 40.558072 | | Latitude: 40.558072 | ||
|- | |- | ||
− | | Longitude: -79. | + | | Longitude: -79.850550 |
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Permits Issued Detail Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref><ref>{{cite web | ||
+ | | title = Spud Data Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-04-30 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-16 }}</ref><ref>{{cite web | ||
+ | | title = Oil and Gas Well Pad Report | ||
+ | |publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2019-05-20 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2010-10-13 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2010-11-15 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2010-11-22 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2010-12-09 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2012-10-19 | ||
+ | | NEWLY DRILLED | ||
|- | |- | ||
|} | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
+ | <!--== Fracking Activities == | ||
+ | ==== Fracking Jobs ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Job Start Date | ||
+ | !scope="col" | Job End Date | ||
+ | !scope="col" | True Vertical Depth (ft) | ||
+ | !scope="col" | Total Water Volume (gal) | ||
+ | !scope="col" | Total Non-Water Volume (gal) | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Fluid Composition Data ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Job Number | ||
+ | !scope="col" | Trade Name | ||
+ | !scope="col" | Supplier | ||
+ | !scope="col" | Purpose | ||
+ | !scope="col" | Ingredient Name | ||
+ | !scope="col" | CAS Number | ||
+ | !scope="col" | Additive Percentage by Mass | ||
+ | !scope="col" | Job Percentage by Mass | ||
+ | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator Name |
− | !scope="col" | | + | !scope="col" | Gas Quantity (mcf) |
− | !scope="col" | | + | !scope="col" | Gas Production Days |
− | !scope="col" | | + | !scope="col" | Oil Quantity (bbl) |
− | !scope="col" | | + | !scope="col" | Oil Production Days |
− | !scope="col" | | + | !scope="col" | Water Quantity (bbl) |
+ | !scope="col" | Water Production Days | ||
|- | |- | ||
− | | 2010 | + | | 2010 |
− | | style="text-align:right;" | 0. | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2011 | ||
+ | | [[MARCO DRILLING INC]] | ||
+ | | style="text-align: right;" | 3,055.60 | ||
+ | | style="text-align: right;" | 180 | ||
+ | | style="text-align: right;" | 269.10 | ||
+ | | style="text-align: right;" | 180 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2012 |
− | | style="text-align:right;" | | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 6,745.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 306.61 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2013 | ||
+ | | [[MARCO DRILLING INC]] | ||
+ | | style="text-align: right;" | 4,748.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 131.70 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2014 |
− | | style="text-align:right;" | | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | 365 | + | | style="text-align: right;" | 4,420.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 109.68 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2015 | ||
+ | | [[MARCO DRILLING INC]] | ||
+ | | style="text-align: right;" | 4,439.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 180.47 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2016 |
− | | style="text-align:right;" | | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | 365 | + | | style="text-align: right;" | 3,673.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 58364 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
+ | | 2017 | ||
+ | | [[MARCO DRILLING INC]] | ||
+ | | style="text-align: right;" | 3,905.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 82.00 | ||
+ | | style="text-align: right;" | 365 | ||
+ | | style="text-align: right;" | 0.00 | ||
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
− | | | + | | 2018 |
− | | style="text-align:right;" | | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | 365 | + | | style="text-align: right;" | 3,299.00 |
− | | style="text-align:right;" | 0. | + | | style="text-align: right;" | 365 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0 |
− | | style="text-align:right;" | | + | | style="text-align: right;" | 0.00 |
+ | | style="text-align: right;" | 0 | ||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Production Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Waste Data == | == Waste Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Period |
− | !scope="col" | | + | !scope="col" | Operator |
− | !scope="col" | | + | !scope="col" | Waste Type |
− | !scope="col" | | + | !scope="col" | Quantity |
− | !scope="col" | | + | !scope="col" | Disposal Method |
− | !scope="col" | | + | !scope="col" | Waste Facility ID |
− | |||
− | |||
− | |||
|- | |- | ||
− | | 2010 | + | | 2010 |
− | | | + | | [[MARCO DRILLING INC]] |
− | | style="text-align:right;" | 240. | + | | Produced Fluid |
− | + | | style="text-align: right;" | 240.00 Bbl | |
| ROAD SPREADING | | ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
− | | | + | | 2011 |
− | | | + | | [[MARCO DRILLING INC]] |
− | | | + | | Produced Fluid |
− | | style="text-align:right;" | 105. | + | | style="text-align: right;" | 105.00 Bbl |
− | |||
| ROAD SPREADING | | ROAD SPREADING | ||
| | | | ||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Waste Reports |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-03-31 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
== Inspection Data == | == Inspection Data == | ||
+ | ==== Inspections Performed ==== | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
− | !scope="col" | | + | !scope="col" | Inspection ID |
− | !scope="col" | | + | !scope="col" | Inspection Category |
− | !scope="col" | | + | !scope="col" | Inspection Date |
− | !scope="col" | | + | !scope="col" | Inspection Type |
− | !scope="col" | | + | !scope="col" | Inspection Result |
− | + | !scope="col" | Inspection Comments | |
− | !scope="col" | | ||
|- | |- | ||
| 1931316 | | 1931316 | ||
+ | | Primary Facility | ||
| 2010-11-24 | | 2010-11-24 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On November 24th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in construction. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | | On November 24th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in construction. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1933181 | | 1933181 | ||
+ | | Primary Facility | ||
| 2010-11-18 | | 2010-11-18 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| USE RIG # 7 IS DRILLING. APPALACHIAN CEMENTING 7". CEMENT RETURN ON 7". | | USE RIG # 7 IS DRILLING. APPALACHIAN CEMENTING 7". CEMENT RETURN ON 7". | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1933187 | | 1933187 | ||
+ | | Primary Facility | ||
| 2010-11-16 | | 2010-11-16 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| RIG DOWN FOR 9 5/8" CEMENT TIME. 5 BBL RETURN ON CEMENT. | | RIG DOWN FOR 9 5/8" CEMENT TIME. 5 BBL RETURN ON CEMENT. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1933558 | | 1933558 | ||
+ | | Primary Facility | ||
| 2010-12-07 | | 2010-12-07 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On December 7th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in production. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. A frac tank was moved in onsite. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | | On December 7th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in production. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. A frac tank was moved in onsite. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1933588 | | 1933588 | ||
+ | | Primary Facility | ||
| 2010-12-10 | | 2010-12-10 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On December 10th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The frac was completed. A swabbing rig was onsite. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | | On December 10th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The frac was completed. A swabbing rig was onsite. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1934069 | | 1934069 | ||
+ | | Primary Facility | ||
| 2010-11-24 | | 2010-11-24 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| USE RIG # 7 HAS MOVED FROM THE SITE. THE SITE IS CLEAN AND THE PIT LEVEL IS OK. | | USE RIG # 7 HAS MOVED FROM THE SITE. THE SITE IS CLEAN AND THE PIT LEVEL IS OK. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1937892 | | 1937892 | ||
+ | | Primary Facility | ||
| 2010-12-07 | | 2010-12-07 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| THE WELL IS BEING PREPARED FOR FRAC. FRAC TANK ON SITE. | | THE WELL IS BEING PREPARED FOR FRAC. FRAC TANK ON SITE. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1937896 | | 1937896 | ||
+ | | Primary Facility | ||
| 2010-12-14 | | 2010-12-14 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
− | | WELL COMPLETED WITH AN OPEN HOLE FRAC. | + | | WELL COMPLETED WITH AN OPEN HOLE FRAC. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1953933 | | 1953933 | ||
+ | | Primary Facility | ||
| 2011-01-18 | | 2011-01-18 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| WELL IS COMPLETE. SITE RESTORED. JACK IS SET. NO TANKS. | | WELL IS COMPLETE. SITE RESTORED. JACK IS SET. NO TANKS. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1957450 | | 1957450 | ||
+ | | Primary Facility | ||
| 2011-02-09 | | 2011-02-09 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
| SITE IS RESTORED. | | SITE IS RESTORED. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1960869 | | 1960869 | ||
+ | | Primary Facility | ||
| 2011-03-17 | | 2011-03-17 | ||
+ | | Drilling/Alteration | ||
| No Violations Noted | | No Violations Noted | ||
− | | JACK IS HOOKED UP. GAS LINE IIS NOT FINISHED. | + | | JACK IS HOOKED UP. GAS LINE IIS NOT FINISHED. |
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 1985393 | | 1985393 | ||
+ | | Primary Facility | ||
| 2011-06-09 | | 2011-06-09 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| On June 9th, 2011 I conducted a routine inspecion of the above site. The well was in production. A well tag was present. The access was in good condition. The site is restored. 2 tanks are present and surrounded by a dike. | | On June 9th, 2011 I conducted a routine inspecion of the above site. The well was in production. A well tag was present. The access was in good condition. The site is restored. 2 tanks are present and surrounded by a dike. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2124787 | | 2124787 | ||
+ | | Primary Facility | ||
| 2012-12-12 | | 2012-12-12 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| WELL MAINTAINED OIL AND GAS WELL. WELL IS IN AN OPEN STONED LOT. THE WELL SITE MATCHES THE LOT. | | WELL MAINTAINED OIL AND GAS WELL. WELL IS IN AN OPEN STONED LOT. THE WELL SITE MATCHES THE LOT. | ||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2165009 | | 2165009 | ||
+ | | Primary Facility | ||
| 2013-05-01 | | 2013-05-01 | ||
+ | | Routine/Complete Inspection | ||
| No Violations Noted | | No Violations Noted | ||
| A WELL MAINTAINED OIL AND GAS WELL WITH TWO DIKED TANKS. THE RESTORATION MATCHES THE PARKING LOT LOCATION. | | A WELL MAINTAINED OIL AND GAS WELL WITH TWO DIKED TANKS. THE RESTORATION MATCHES THE PARKING LOT LOCATION. | ||
− | |||
− | |||
− | |||
|- | |- | ||
|} | |} | ||
+ | <!--==== Violations Commited ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Inspection ID | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Violation Date | ||
+ | !scope="col" | Date Resolved | ||
+ | !scope="col" | Violation Code | ||
+ | !scope="col" | Violation Type | ||
+ | !scope="col" | Violation Comments | ||
+ | |- | ||
+ | |}--> | ||
+ | <!--==== Penalties Applied ==== | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Violation ID | ||
+ | !scope="col" | Penalty ID | ||
+ | !scope="col" | Penalty Code | ||
+ | !scope="col" | Penalty Status | ||
+ | !scope="col" | Penalty Date | ||
+ | !scope="col" | Enforcement Date | ||
+ | !scope="col" | Penalty Amount | ||
+ | !scope="col" | Amount Collected | ||
+ | |- | ||
+ | |}--> | ||
For data sources see<ref>{{cite web | For data sources see<ref>{{cite web | ||
− | | title = Oil and Gas | + | | title =Oil and Gas Compliance Report |
− | + | |publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2019-05-20 | |
− | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources |
− | | accessdate = | + | | accessdate = 2019-05-21 }}</ref> |
− | == References == | + | ==References== |
− | + | <references/> | |
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
− | [[Category:Wells]] | + | [[Category:Pennsylvania Wells]] |
Well ID: 37-003-22145 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.558072,"lon":-79.85055,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Allegheny | |
Municipality: Harmar Township | |
Operator Name: MARCO DRILLING INC | |
Well Pad ID: | |
Farm/Lease Name: DFGT PROPERTIES LLC 1-6 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-10-13 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.558072 | |
Longitude: -79.850550 |
Date | Event |
---|---|
2010-10-13 | New Permit Application |
2010-11-15 | Performed Spud Operation |
2010-11-22 | Drilling Completion |
2010-12-09 | Perforation |
2012-10-19 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | MARCO DRILLING INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | MARCO DRILLING INC | 3,055.60 | 180 | 269.10 | 180 | 0.00 | 0 |
2012 | MARCO DRILLING INC | 6,745.00 | 365 | 306.61 | 365 | 0.00 | 0 |
2013 | MARCO DRILLING INC | 4,748.00 | 365 | 131.70 | 365 | 0.00 | 0 |
2014 | MARCO DRILLING INC | 4,420.00 | 365 | 109.68 | 365 | 0.00 | 0 |
2015 | MARCO DRILLING INC | 4,439.00 | 365 | 180.47 | 365 | 0.00 | 0 |
2016 | MARCO DRILLING INC | 3,673.00 | 365 | 58364 | 365 | 0.00 | 0 |
2017 | MARCO DRILLING INC | 3,905.00 | 365 | 82.00 | 365 | 0.00 | 0 |
2018 | MARCO DRILLING INC | 3,299.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | MARCO DRILLING INC | Produced Fluid | 240.00 Bbl | ROAD SPREADING | |
2011 | MARCO DRILLING INC | Produced Fluid | 105.00 Bbl | ROAD SPREADING |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1931316 | Primary Facility | 2010-11-24 | Routine/Complete Inspection | No Violations Noted | On November 24th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in construction. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. |
1933181 | Primary Facility | 2010-11-18 | Drilling/Alteration | No Violations Noted | USE RIG # 7 IS DRILLING. APPALACHIAN CEMENTING 7". CEMENT RETURN ON 7". |
1933187 | Primary Facility | 2010-11-16 | Drilling/Alteration | No Violations Noted | RIG DOWN FOR 9 5/8" CEMENT TIME. 5 BBL RETURN ON CEMENT. |
1933558 | Primary Facility | 2010-12-07 | Routine/Complete Inspection | No Violations Noted | On December 7th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The well was not yet in production. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. A frac tank was moved in onsite. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. |
1933588 | Primary Facility | 2010-12-10 | Routine/Complete Inspection | No Violations Noted | On December 10th, 2010 I conducted a routine inspecion of the above site. Drilling was completed. The frac was completed. A swabbing rig was onsite. The access road was in good condition. A site ID sign and E&S plan were present. The pit appeared to be in good condition. The operator should continue to inspect the E&S controls routinely and after each runoff event until the site is restored and uniform 70% vegetative cover is achieved. |
1934069 | Primary Facility | 2010-11-24 | Drilling/Alteration | No Violations Noted | USE RIG # 7 HAS MOVED FROM THE SITE. THE SITE IS CLEAN AND THE PIT LEVEL IS OK. |
1937892 | Primary Facility | 2010-12-07 | Drilling/Alteration | No Violations Noted | THE WELL IS BEING PREPARED FOR FRAC. FRAC TANK ON SITE. |
1937896 | Primary Facility | 2010-12-14 | Drilling/Alteration | No Violations Noted | WELL COMPLETED WITH AN OPEN HOLE FRAC. |
1953933 | Primary Facility | 2011-01-18 | Drilling/Alteration | No Violations Noted | WELL IS COMPLETE. SITE RESTORED. JACK IS SET. NO TANKS. |
1957450 | Primary Facility | 2011-02-09 | Drilling/Alteration | No Violations Noted | SITE IS RESTORED. |
1960869 | Primary Facility | 2011-03-17 | Drilling/Alteration | No Violations Noted | JACK IS HOOKED UP. GAS LINE IIS NOT FINISHED. |
1985393 | Primary Facility | 2011-06-09 | Routine/Complete Inspection | No Violations Noted | On June 9th, 2011 I conducted a routine inspecion of the above site. The well was in production. A well tag was present. The access was in good condition. The site is restored. 2 tanks are present and surrounded by a dike. |
2124787 | Primary Facility | 2012-12-12 | Routine/Complete Inspection | No Violations Noted | WELL MAINTAINED OIL AND GAS WELL. WELL IS IN AN OPEN STONED LOT. THE WELL SITE MATCHES THE LOT. |
2165009 | Primary Facility | 2013-05-01 | Routine/Complete Inspection | No Violations Noted | A WELL MAINTAINED OIL AND GAS WELL WITH TWO DIKED TANKS. THE RESTORATION MATCHES THE PARKING LOT LOCATION. |
For data sources see[7]