If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-005-30381 | | Well ID: 37-005-30381 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.836610, -79.554152 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 17: | Line 17: | ||
| Well Pad ID: [[146142]] | | Well Pad ID: [[146142]] | ||
|- | |- | ||
− | | Farm/Lease Name: C H SNYDER CO UNIT | + | | Farm/Lease Name: C H SNYDER CO UNIT |
|- | |- | ||
− | | License Status: Plugged | + | | License Status: Plugged and Abandoned |
|- | |- | ||
− | | Spud Date: 2010-04- | + | | Spud Date: 2010-04-23 |
|- | |- | ||
| Permit Date: 2009-06-30 | | Permit Date: 2009-06-30 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Vertical Well | | Configuration: Vertical Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 40.836610 | | Latitude: 40.836610 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2009-06-30 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2010-04-21 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2010-05-01 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2010-07-01 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2013-05-15 | ||
+ | | NEWLY DRILLED | ||
+ | |- | ||
+ | | 2018-05-01 | ||
+ | | Begin Plugging | ||
+ | |- | ||
+ | | 2018-05-04 | ||
+ | | Finished Plugging | ||
+ | |- | ||
+ | | 2018-08-23 | ||
+ | | Fully Plugged | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
<!--== Fracking Activities == | <!--== Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 71: | Line 110: | ||
!scope="col" | Job Percentage by Mass | !scope="col" | Job Percentage by Mass | ||
!scope="col" | Mass Used (lb) | !scope="col" | Mass Used (lb) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
|- | |- | ||
|}--> | |}--> | ||
Line 184: | Line 234: | ||
| 2010 | | 2010 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 965.00 Bbl | | style="text-align: right;" | 965.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 191: | Line 241: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 220.00 Bbl | | style="text-align: right;" | 220.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 198: | Line 248: | ||
| 2011 | | 2011 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 180.00 Bbl | | style="text-align: right;" | 180.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 205: | Line 255: | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 160.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-155- | + | | 34-155-21438 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 80.00 Bbl |
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
− | | 34-155- | + | | 34-155-23584 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 94.00 Bbl | | style="text-align: right;" | 94.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 226: | Line 276: | ||
| 2014 | | 2014 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 93.00 Bbl | | style="text-align: right;" | 93.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 233: | Line 283: | ||
| 2015 | | 2015 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 93.00 Bbl | | style="text-align: right;" | 93.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 240: | Line 290: | ||
| 2016 | | 2016 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 93.00 Bbl | | style="text-align: right;" | 93.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 247: | Line 297: | ||
| 2017 | | 2017 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
+ | | style="text-align: right;" | 95.00 Bbl | ||
+ | | INJECTION DISPOSAL WELL | ||
+ | | 34-155-23223 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[SNYDER BROS INC]] | ||
+ | |||
| style="text-align: right;" | 95.00 Bbl | | style="text-align: right;" | 95.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL | ||
Line 254: | Line 311: | ||
| 2018 | | 2018 | ||
| [[SNYDER BROS INC]] | | [[SNYDER BROS INC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 15.00 Bbl | | style="text-align: right;" | 15.00 Bbl | ||
| INJECTION DISPOSAL WELL | | INJECTION DISPOSAL WELL |
Well ID: 37-005-30381 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.83661,"lon":-79.554152,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: East Franklin Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146142 | |
Farm/Lease Name: C H SNYDER CO UNIT | |
License Status: Plugged and Abandoned | |
Spud Date: 2010-04-23 | |
Permit Date: 2009-06-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.836610 | |
Longitude: -79.554152 |
Date | Event |
---|---|
2009-06-30 | New Permit Application |
2010-04-21 | Performed Spud Operation |
2010-05-01 | Drilling Completion |
2010-07-01 | Perforation |
2013-05-15 | NEWLY DRILLED |
2018-05-01 | Begin Plugging |
2018-05-04 | Finished Plugging |
2018-08-23 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SNYDER BROS INC | 25,316.00 | 143 | 0.00 | 0 | 0.00 | 0 |
2011 | SNYDER BROS INC | 29,621.00 | 292 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 26,830.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 20,420.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 15,953.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 14,045.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 15,037.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 11,410.00 | 352 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 2,759.00 | 110 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | SNYDER BROS INC | Produced Fluid | 965.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | SNYDER BROS INC | Produced Fluid | 220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | SNYDER BROS INC | Produced Fluid | 180.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | SNYDER BROS INC | Produced Fluid | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23584 |
2013 | SNYDER BROS INC | Produced Fluid | 94.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2015 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2016 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | SNYDER BROS INC | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 | |
2018 | SNYDER BROS INC | Produced Fluid | 15.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1800201 | Primary Facility | 2009-05-21 | Routine/Complete Inspection | No Violations Noted | Well staked, site not constructed at the time of the inspection. Met onsite with operator representatives Todd Kunselman and Doug Miller to review the proposed site and existing access road. The E&S plan as submitted should effectively minimize accelerated erosion & sedimentation, provided the erosion control measures are implemented and maintained properly. |
1882318 | Primary Facility | 2010-04-27 | Routine/Complete Inspection | No Violations Noted | Drill rig was on-site during the inspection. Drill pit appears to be in sound condition. Located the Site ID sign and E&S plan. E&S controls such as silt fence and rocked culverts have been installed. The operator has already seeded and mulched many of the disturbed areas. At this time, there are no signs of erosion or sedimentation on the access road or well site. |
1883728 | Primary Facility | 2010-04-26 | Drilling/Alteration | No Violations Noted | MARCELLUS - drilling/E&S ok/ID&pit ok |
1894959 | Primary Facility | 2010-06-29 | Complaint Inspection | No Violations Noted | shawn clark called said had oil taste in spring water, turned over to wqs |
1896395 | Primary Facility | 2010-06-30 | Complaint Inspection | No Violations Noted | Frac crews on-site at the time of the inspection. Site ID sign and E&S plan located. The pit appears to be in sound condition. No visible signs of a brine release or pit failure. No E&S concerns at this time. |
1919204 | Primary Facility | 2010-09-28 | Routine/Complete Inspection | No Violations Noted | Well is equipped for production. Tag located. Brine tanks appear to be in sound condition. The site was recently seeded & mulched. No E&S concerns at this time. |
2082730 | Primary Facility | 2012-07-12 | Site Restoration | No Violations Noted | At the time of inspection the well appeared to be drilled and equipped for production. The associated well apparatus, brine tank, and pump jack located onsite appear to be in sound condition. The site is restored and meets the 70% uniform vegetative coverage criteria. |
2448897 | Primary Facility | 2016-02-11 | Routine/Complete Inspection | No Violations Noted | Well tagged-in production. Well head casing-production equipment- 2-100 bbl tanks look ok. |
2725239 | Primary Facility | 2018-05-02 | Routine/Complete Inspection | No Violations Noted | Inspection conducted in response to electronic plugging notification submitted by operator. At time of inspection, rig on-site actively working on well. |
2727925 | Primary Facility | 2018-05-09 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | The operator has just finished plugging this well and the rig was gone at the time of this inspection. The well was cemented solid from the TD to surface and a monument with the well API number permanently affixed to it was set. |
2819944 | Primary Facility | 2018-12-27 | Site Restoration | No Violations Noted | Inspection conducted in response to a Post Plugging Site Restoration Report received by Department.
At time of inspection well is plugged. Monument present with permit number permanently affixed (photo #1). No E and S issues observed on site. Site appears to be returned to near original contours. Vegetation appears to have reached >70% uniform growth. This Restoration Report is approved. |
For data sources see[7]