X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-015-20992"

m
m
 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-015-20992
 
| Well ID: 37-015-20992
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.772875, -76.207047 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.772875, -76.207047 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Bradford County, Pennsylvania|Bradford]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Stevens Township, Bradford County, Pennsylvania|Stevens Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[SOUTHWESTERN ENERGY PROD CO|SOUTHWESTERN ENERGY PROD CO]]
+
| County: [[Bradford_County,_Pennsylvania|Bradford]]
 
|-
 
|-
| Well Pad ID: [[149204]]
+
| Municipality: [[Stevens Township,_Bradford_County,_Pennsylvania|Stevens Township]]
 +
|-
 +
| Operator Name: [[SWN PROD CO LLC]]
 +
|-
 +
| Well Pad ID: [[150454]]
 
|-
 
|-
 
| Farm/Lease Name: ROBINSON FERGUSON G U 3H
 
| Farm/Lease Name: ROBINSON FERGUSON G U 3H
 
|-
 
|-
| First Permit Date: 2010-07-13
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2010-07-13
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2010-07-22
+
| Permit Date: 2010-07-13
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: None
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.772875
 
| Latitude: 41.772875
 
|-
 
|-
 
| Longitude: -76.207047
 
| Longitude: -76.207047
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2010-07-13
 +
| New Permit Application
 +
|-
 +
| 2010-07-22
 +
| Performed Spud Operation
 +
|-
 +
| 2010-11-30
 +
| DEVIATED
 
|-
 
|-
 
|}
 
|}
__TOC__
+
For data sources see<ref>{{cite web
== Inspection Data ==
+
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2011-01-11
 +
| 2011-01-11
 +
| style="text-align: right;" | 6,381
 +
| style="text-align: right;" | 5,455,581
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="28"| 1
 +
| rowspan="2"| Mesh Sand
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Proppant
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 8.64
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="5"| A264 Corrosion Inhibitor
 +
| rowspan="5"| Schlumberger
 +
| rowspan="5"| Corrosion Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00068000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00017000
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic Alcohols, Ethoxylated #1
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00051000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic Acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00051000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Hydrochloric Acid 7.5
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Acidizing
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 7.50
 +
| style="text-align: right;" | 0.06
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Breaker J218
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Friction Reducer
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Peroxydisulfuric acid, diammonium salt
 +
| 7727-54-0
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00084000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| L058
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Iron Stabilizer
 +
| Sodium erythorbate
 +
| 6381-77-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00055000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Biodegrable Starch Loosefill
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Gelling Agent
 +
| Carbohydrate Polymer
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00091000
 +
| style="text-align: right;" |
 +
|-
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Green-Cide 25G
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Bactericide
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 25.00
 +
| style="text-align: right;" | 0.00565000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| B-315
 +
| rowspan="3"| Schlumberger
 +
| rowspan="3"| Friction Reducer
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic Alcohol Glycol Ether
 +
|
 +
| style="text-align: right;" | 1.50
 +
| style="text-align: right;" | 0.00140000
 +
| style="text-align: right;" |
 +
|-
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.02
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Diagnostic Tracer
 +
| rowspan="1"| ProTechnics
 +
| rowspan="1"| Diagnostic
 +
| Sodium Salt
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00008000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| Scale Inhibitor B317
 +
| rowspan="3"| Schlumberger
 +
| rowspan="3"| Scale Inhibitor
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00057000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2008500
 
| 2011-10-05
 
| No Violations Noted
 
| Well is drilled and in prod.  Cellar is not filled in, has about 6" water.  No bubbles.  Dave Bowman (Southwestern) on site, will be pulling rathole pipe tomorrow.  Well tag, just sign with well name and number, no permit number, etc.  Site looks good.
 
 
|  
 
|  
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Trisodium phosphate
 +
| 7601-54-9
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00057000
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Salt
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Formation Inhibitor
 +
| Calcium chloride
 +
| 10043-52-4
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00130000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2122907
 
| 2012-10-16
 
| No Violations Noted
 
| Cellar filled with gravel.  5 1/2 casing pressure = 539.92 psi.  Tubing pressure = 647.18psi.
 
 
|  
 
|  
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="2"| Slickwater
 +
| rowspan="2"| Southwestern Energy
 +
| rowspan="2"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 
|-
 
|-
| 2142788
+
| Mix Water
| 2013-01-22
 
| No Violations Noted
 
| Well fract and in production.  Cellar filled with water and frozen.  (6-8" snow on ground)
 
 
|  
 
|  
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 90.31
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| 2012-2
+
| 2010
| style="text-align:right;" | 818024.0
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 183.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2011
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 1,883,049.00
 +
| style="text-align: right;" | 310
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2012
| style="text-align:right;" | 986456.0
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 179.0
+
| style="text-align: right;" | 1,804,480.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 362
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2013
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| style="text-align: right;" | 1,119,669.00
 +
| style="text-align: right;" | 351
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2014
| style="text-align:right;" | 1140314.0
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 177.0
+
| style="text-align: right;" | 918,563.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2015
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 700,809.00
 +
| style="text-align: right;" | 338
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2016
| style="text-align:right;" | 742735.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 133.0
+
| style="text-align: right;" | 632,006.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 366
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| style="text-align: right;" | 504,721.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2018
| style="text-align:right;" | 0.0
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 408,010.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
|-
+
| 2019
| 2010-3
+
| [[SWN PROD CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 455,755.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 360
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-1
+
| 2012
| FLOWBACK FRACTURING SAND
+
| [[SOUTHWESTERN ENERGY PROD CO]]
| style="text-align:right;" | 1.0
+
| Fracturing Fluid Waste
| Tons
+
| style="text-align: right;" | 1.00 Tons
 
| LANDFILL
 
| LANDFILL
 
| 101247
 
| 101247
| KEYSTONE SANITARY LANDFILL
+
|-
| DUNMORE
+
| 2013
| PA
+
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 793.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2014
 +
| [[SOUTHWESTERN ENERGY PROD CO]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,683.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2015
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,138.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 503.66 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123NC018
 +
|-
 +
| 2016
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 145.83 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 39.66 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 55.33 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 153.82 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 18.33 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2017
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 14.16 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 40.00 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 330.83 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 109.77 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 54.99 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 66.66 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Spent Lubricant Waste
 +
| style="text-align: right;" | 18.33 Bbl
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| 101532
 +
|-
 +
| 2018
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 246.30 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 20.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC035
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Spent Lubricant Waste
 +
| style="text-align: right;" | 18.33 Bbl
 +
| RESIDUAL WASTE TRANSFER FACILITY
 +
| 101532
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 282.33 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 67.58 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 95-16-65420-013
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 33.66 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 111.67 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 +
|-
 +
| 2019
 +
| [[SWN PROD CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 18.33 Bbl
 +
| SURFACE IMPOUNDMENT
 +
| 826342
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 2008500
 +
| Primary Facility
 +
| 2011-10-05
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well is drilled and in prod.  Cellar is not filled in, has about 6" water.  No bubbles.  Dave Bowman (Southwestern) on site, will be pulling rathole pipe tomorrow.  Well tag, just sign with well name and number, no permit number, etc.  Site looks good.
 +
|-
 +
| 2122907
 +
| Primary Facility
 +
| 2012-10-16
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Cellar filled with gravel.  5 1/2 casing pressure = 539.92 psi.  Tubing pressure = 647.18psi.
 +
|-
 +
| 2142788
 +
| Primary Facility
 +
| 2013-01-22
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Well fract and in production.  Cellar filled with water and frozen.  (6-8" snow on ground)
 +
|-
 +
| 2160444
 +
| Primary Facility
 +
| 2013-04-22
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2358647
 +
| Primary Facility
 +
| 2015-04-02
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2473462
 +
| Primary Facility
 +
| 2016-04-07
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2618313
 +
| Primary Facility
 +
| 2017-07-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| On July 19, 2017, the Department conducted a routine inspection at the SWN Production Company, LLC, GU-H-Pad in Stevens Township, Bradford County.  Andrew Hobbins, Water Quality Specialist, represented the Department.  A crew was on site during the inspection working to install a compressor. 
 +
 +
The site sign, E & S plan and weekly inspection logs were on site and available for review.  The slopes of the pad were well vegetated and no erosion issues were observed.  PCSM has not been addressed at the site.  The site has been re-permitted as an ESCGP-2 and PCSM has been proposed to be installed this month.  The area in which the bio-infiltration berm is to be installed was observed to be mowed and staked out, but has not yet been installed.
 +
 +
Six wells were in production during the inspection.  The wells were labeled and no bubbling was observed in the well cellars.  Two production tanks and six GPUs were on site.  No staining or puddles were observed on the pad surface.  A compressor was being installed on the
 +
|-
 +
| 2665423
 +
| Primary Facility
 +
| 2017-11-14
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| On November 14, the Department conducted a incident response inspection at the SWN Production Company GU-H-Pad in Stevens Township, Bradford County.  Andrew Hobbins and Jonathan Sassi represented the Department.  Mike Demming was on site for SWN. 
 +
 +
The Department was notified on 11/13/2017 by Steve Moyer, Regulatory Supervisor, that SWN discovered a spill on the GU-H-Pad.  The material spilled was injection water which is a mixture of freshwater and methanol at an 8:2 ratio.  The ratio of methanol to freshwater was significantly less than 8:2 which caused the injection water to freeze due to cold weather.  The freezing caused a fitting to fail and injection water spilled onto secondary containment.  The secondary containment around the injection water tank had a structural defect at one corner that allowed the fluid to escape and spill onto the well pad surface.  Approximately 2000 gallons was released from the tank, 1500 gallons of which made it onto the well pad surface.
 +
 +
SWN immediately contracted Resou
 +
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
|}-->
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 11:44, 21 May 2020

Well Details

Well ID: 37-015-20992
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Stevens Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150454
Farm/Lease Name: ROBINSON FERGUSON G U 3H
License Status:
Spud Date:
Permit Date: 2010-07-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.772875
Longitude: -76.207047

For data sources see[1][2][3]

Well History

Date Event
2010-07-13 New Permit Application
2010-07-22 Performed Spud Operation
2010-11-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-01-11 2011-01-11 6,381 5,455,581

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Mesh Sand Schlumberger Proppant Quartz 14808-60-7 100.00 8.64
A264 Corrosion Inhibitor Schlumberger Corrosion Inhibitor Methanol 67-56-1 40.00 0.00068000
Propargyl alcohol 107-19-7 10.00 0.00017000
Aliphatic Alcohols, Ethoxylated #1 30.00 0.00051000
Aliphatic Acids 30.00 0.00051000
Hydrochloric Acid 7.5 Schlumberger Acidizing
Hydrochloric acid 7647-01-0 7.50 0.06
Breaker J218 Schlumberger Friction Reducer
Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00084000
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100.00 0.00055000
Biodegrable Starch Loosefill Schlumberger Gelling Agent Carbohydrate Polymer 100.00 0.00091000
Green-Cide 25G Schlumberger Bactericide
Glutaraldehyde 111-30-8 25.00 0.00565000
B-315 Schlumberger Friction Reducer
Aliphatic Alcohol Glycol Ether 1.50 0.00140000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Diagnostic Tracer ProTechnics Diagnostic Sodium Salt 10.00 0.00008000
Scale Inhibitor B317 Schlumberger Scale Inhibitor Ethylene glycol 107-21-1 5.00 0.00057000
Trisodium phosphate 7601-54-9 5.00 0.00057000
Salt Schlumberger Formation Inhibitor Calcium chloride 10043-52-4 100.00 0.00130000
Slickwater Southwestern Energy Carrier/Base Fluid
Mix Water 100.00 90.31

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2011 SOUTHWESTERN ENERGY PROD CO 1,883,049.00 310 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 1,804,480.00 362 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 1,119,669.00 351 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 918,563.00 364 0.00 0 0.00 0
2015 SWN PROD CO LLC 700,809.00 338 0.00 0 0.00 0
2016 SWN PROD CO LLC 632,006.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 504,721.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 408,010.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 455,755.00 360 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 1.00 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 793.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,683.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 1,138.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 503.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 145.83 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 39.66 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 55.33 Bbl SURFACE IMPOUNDMENT 826342
2017 SWN PROD CO LLC Produced Fluid 153.82 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 18.33 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Other Oil & Gas Wastes 14.16 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 40.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 330.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 109.77 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 54.99 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 66.66 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Spent Lubricant Waste 18.33 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2018 SWN PROD CO LLC Other Oil & Gas Wastes 246.30 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Spent Lubricant Waste 18.33 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2019 SWN PROD CO LLC Produced Fluid 282.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 67.58 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 33.66 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 111.67 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 18.33 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2008500 Primary Facility 2011-10-05 Routine/Complete Inspection No Violations Noted Well is drilled and in prod. Cellar is not filled in, has about 6" water. No bubbles. Dave Bowman (Southwestern) on site, will be pulling rathole pipe tomorrow. Well tag, just sign with well name and number, no permit number, etc. Site looks good.
2122907 Primary Facility 2012-10-16 Routine/Complete Inspection No Violations Noted Cellar filled with gravel. 5 1/2 casing pressure = 539.92 psi. Tubing pressure = 647.18psi.
2142788 Primary Facility 2013-01-22 Routine/Complete Inspection No Violations Noted Well fract and in production. Cellar filled with water and frozen. (6-8" snow on ground)
2160444 Primary Facility 2013-04-22 Incident- Response to Accident or Event No Violations Noted
2358647 Primary Facility 2015-04-02 Routine/Complete Inspection No Violations Noted
2473462 Primary Facility 2016-04-07 Routine/Complete Inspection No Violations Noted
2618313 Primary Facility 2017-07-19 Routine/Complete Inspection No Violations Noted On July 19, 2017, the Department conducted a routine inspection at the SWN Production Company, LLC, GU-H-Pad in Stevens Township, Bradford County. Andrew Hobbins, Water Quality Specialist, represented the Department. A crew was on site during the inspection working to install a compressor.

The site sign, E & S plan and weekly inspection logs were on site and available for review. The slopes of the pad were well vegetated and no erosion issues were observed. PCSM has not been addressed at the site. The site has been re-permitted as an ESCGP-2 and PCSM has been proposed to be installed this month. The area in which the bio-infiltration berm is to be installed was observed to be mowed and staked out, but has not yet been installed.

Six wells were in production during the inspection. The wells were labeled and no bubbling was observed in the well cellars. Two production tanks and six GPUs were on site. No staining or puddles were observed on the pad surface. A compressor was being installed on the

2665423 Primary Facility 2017-11-14 Incident- Response to Accident or Event No Violations Noted On November 14, the Department conducted a incident response inspection at the SWN Production Company GU-H-Pad in Stevens Township, Bradford County. Andrew Hobbins and Jonathan Sassi represented the Department. Mike Demming was on site for SWN.

The Department was notified on 11/13/2017 by Steve Moyer, Regulatory Supervisor, that SWN discovered a spill on the GU-H-Pad. The material spilled was injection water which is a mixture of freshwater and methanol at an 8:2 ratio. The ratio of methanol to freshwater was significantly less than 8:2 which caused the injection water to freeze due to cold weather. The freezing caused a fitting to fail and injection water spilled onto secondary containment. The secondary containment around the injection water tank had a structural defect at one corner that allowed the fluid to escape and spill onto the well pad surface. Approximately 2000 gallons was released from the tank, 1500 gallons of which made it onto the well pad surface.

SWN immediately contracted Resou

For data sources see[8]

References