X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-019-22327"

m
m
 
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-019-22327
 
| Well ID: 37-019-22327
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.947719, -79.871164 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 40.947719, -79.871164 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 2014-12-11
+
| Spud Date: 2014-12-12
 
|-
 
|-
 
| Permit Date: 2014-09-23
 
| Permit Date: 2014-09-23
 +
|-
 +
| Well Type: GAS
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
 
|-
 
|-
 
| Configuration: Horizontal Well
 
| Configuration: Horizontal Well
 +
|-
 +
| Conservation: No
 
|-
 
|-
 
| Latitude: 40.947719
 
| Latitude: 40.947719
Line 49: Line 53:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2014-09-23
 +
| New Permit Application
 +
|-
 +
| 2014-12-11
 +
| Performed Spud Operation
 +
|-
 +
| 2015-03-02
 +
| Drilling Completion
 +
|-
 +
| 2015-07-19
 +
| Perforation
 +
|-
 +
| 2016-01-06
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 
== Fracking Activities ==
 
== Fracking Activities ==
 
==== Fracking Jobs ====
 
==== Fracking Jobs ====
Line 62: Line 92:
 
| 2015-07-19
 
| 2015-07-19
 
| 2015-08-25
 
| 2015-08-25
| style="text-align: right;" | 5413
+
| style="text-align: right;" | 5,413
| style="text-align: right;" | 9,085,650.0
+
| style="text-align: right;" | 9,085,650
 
| style="text-align: right;" | 0
 
| style="text-align: right;" | 0
 
|-
 
|-
Line 276: Line 306:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-06-19 }}</ref>
 
  | accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 325: Line 366:
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| style="text-align: right;" | 179,238.67
+
| style="text-align: right;" | 179,409.76
 
| style="text-align: right;" | 267
 
| style="text-align: right;" | 267
 
| style="text-align: right;" | 0.00
 
| style="text-align: right;" | 0.00
Line 359: Line 400:
 
| 2014
 
| 2014
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
 
| style="text-align: right;" | 21.41 Tons
 
| style="text-align: right;" | 21.41 Tons
 
| LANDFILL
 
| LANDFILL
Line 366: Line 407:
 
| 2015
 
| 2015
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Drilling Fluid Waste (in Barrels)
+
| Drilling Fluid Waste
| style="text-align: right;" | 430.00 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| WMGR123SW005
 
|-
 
| 2015
 
| [[EM ENERGY PA LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
 
| style="text-align: right;" | 280.81 Bbl
 
| style="text-align: right;" | 280.81 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
Line 380: Line 414:
 
| 2015
 
| 2015
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Drill Cuttings (in Tons)
+
| Drill Cuttings
 
| style="text-align: right;" | 936.82 Tons
 
| style="text-align: right;" | 936.82 Tons
 
| LANDFILL
 
| LANDFILL
Line 387: Line 421:
 
| 2015
 
| 2015
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Drilling Fluid Waste
 +
| style="text-align: right;" | 430.00 Bbl
 +
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 +
| WMGR123SW005
 +
|-
 +
| 2015
 +
| [[EM ENERGY PA LLC]]
 +
| Fracing Fluid Waste
 
| style="text-align: right;" | 1,466.25 Bbl
 
| style="text-align: right;" | 1,466.25 Bbl
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
 
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
Line 394: Line 435:
 
| 2015
 
| 2015
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Fracing Fluid Waste (in Barrels)
+
| Fracing Fluid Waste
 
| style="text-align: right;" | 2,158.13 Bbl
 
| style="text-align: right;" | 2,158.13 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
Line 401: Line 442:
 
| 2016
 
| 2016
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Filter Socks (in Tons) RWC 812
+
| Filter Socks
 
| style="text-align: right;" | 0.04 Tons
 
| style="text-align: right;" | 0.04 Tons
 
| LANDFILL
 
| LANDFILL
Line 408: Line 449:
 
| 2016
 
| 2016
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Waste Water Treatment Sludge (in Tons) RWC 804
+
| Waste Water Treatment Sludge
 +
| style="text-align: right;" | 2.04 Tons
 +
| LANDFILL
 +
| 100585
 +
|-
 +
| 2016
 +
| [[EM ENERGY PA LLC]]
 +
| Waste Water Treatment Sludge
 
| style="text-align: right;" | 0.23 Tons
 
| style="text-align: right;" | 0.23 Tons
 
| LANDFILL
 
| LANDFILL
Line 415: Line 463:
 
| 2016
 
| 2016
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 6.25 Bbl
 
| style="text-align: right;" | 6.25 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123NW009
 
| WMGR123NW009
 
|-
 
|-
| 2016
+
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Waste Water Treatment Sludge (in Tons) RWC 804
+
| Waste Water Treatment Sludge
| style="text-align: right;" | 2.04 Tons
+
| style="text-align: right;" | 3.67 Tons
| LANDFILL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 100585
+
| 2014-541
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Other Oil & Gas Wastes
| style="text-align: right;" | 3,494.28 Bbl
+
| style="text-align: right;" | 12.50 Bbl
| REUSE (AT WELL PAD)
+
| RESIDUAL WASTE PROCESSING FACILITY
|  
+
| WMGR123SW005
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Other Oil & Gas Wastes
| style="text-align: right;" | 634.54 Bbl
+
| style="text-align: right;" | 33.25 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR123SW019
+
| WMGR123NW009
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 219.18 Bbl
+
| style="text-align: right;" | 634.54 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| RESIDUAL WASTE PROCESSING FACILITY
| PA0254185
+
| WMGR123SW019
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Other Oil & Gas Wastes (in Barrels) RWC 899
+
| Produced Fluid
| style="text-align: right;" | 33.25 Bbl
+
| style="text-align: right;" | 1,013.95 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR123NW009
+
| WMGR123SW005
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Other Oil & Gas Wastes (in Barrels) RWC 899
+
| Produced Fluid
| style="text-align: right;" | 12.50 Bbl
+
| style="text-align: right;" | 3,169.28 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| REUSE (AT WELL PAD)
| WMGR123SW005
+
|  
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Waste Water Treatment Sludge (in Tons) RWC 804
+
| Produced Fluid
| style="text-align: right;" | 3.67 Tons
+
| style="text-align: right;" | 219.18 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| 2014-541
+
| PA0254185
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 1,013.95 Bbl
+
| style="text-align: right;" | 3,279.23 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
| WMGR123SW005
+
| WMGR123NW009
 
|-
 
|-
 
| 2017
 
| 2017
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Other Oil & Gas Wastes (in Barrels) RWC 899
+
| Other Oil & Gas Wastes
 
| style="text-align: right;" | 4.15 Bbl
 
| style="text-align: right;" | 4.15 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123SW019
 
| WMGR123SW019
 
|-
 
|-
| 2017
+
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 3,279.23 Bbl
+
| style="text-align: right;" | 38.51 Bbl
| RESIDUAL WASTE PROCESSING FACILITY
+
| INJECTION DISPOSAL WELL
| WMGR123NW009
+
| 34-155-24063
 
|-
 
|-
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 625.01 Bbl
 
| style="text-align: right;" | 625.01 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
Line 499: Line 547:
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 
| style="text-align: right;" | 27.37 Bbl
 
| style="text-align: right;" | 27.37 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 506: Line 554:
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 109.65 Bbl
+
| style="text-align: right;" | 198.16 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-24079
+
| 34-099-23158
 
|-
 
|-
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 38.51 Bbl
+
| style="text-align: right;" | 109.65 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-155-24063
+
| 34-155-24079
 
|-
 
|-
 
| 2018
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 198.16 Bbl
 
| INJECTION DISPOSAL WELL
 
| 34-099-23158
 
|-
 
| 2018
 
| [[EM ENERGY PA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
 
| style="text-align: right;" | 285.50 Bbl
 
| style="text-align: right;" | 285.50 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
Line 534: Line 575:
 
| 2019
 
| 2019
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
 +
| style="text-align: right;" | 34.64 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-24063
 +
|-
 +
| 2019
 +
| [[EM ENERGY PA LLC]]
 +
| Produced Fluid
 
| style="text-align: right;" | 35.80 Bbl
 
| style="text-align: right;" | 35.80 Bbl
 
| REUSE (AT WELL PAD)
 
| REUSE (AT WELL PAD)
Line 541: Line 589:
 
| 2019
 
| 2019
 
| [[EM ENERGY PA LLC]]
 
| [[EM ENERGY PA LLC]]
| Produced Fluid (in Barrels) RWC 802
+
| Produced Fluid
| style="text-align: right;" | 34.64 Bbl
+
| style="text-align: right;" | 135.27 Bbl
| INJECTION DISPOSAL WELL
 
| 34-155-24063
 
|-
 
| 2019
 
| [[EM ENERGY PA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 102.77 Bbl
 
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
 
| 34-155-24079
 
| 34-155-24079

Latest revision as of 21:50, 21 May 2020

Well Details

Well ID: 37-019-22327
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Oakland Township
Operator Name: EM ENERGY PA LLC
Well Pad ID: 150798
Farm/Lease Name: URSA MINOR 11BH
License Status: Active
Spud Date: 2014-12-12
Permit Date: 2014-09-23
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.947719
Longitude: -79.871164

For data sources see[1][2][3]

Well History

Date Event
2014-09-23 New Permit Application
2014-12-11 Performed Spud Operation
2015-03-02 Drilling Completion
2015-07-19 Perforation
2016-01-06 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-07-19 2015-08-25 5,413 9,085,650 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 H015, Slickwater Schlumberger Corrosion Inhibitor, Scale Inhibitor, Acid, Breaker, Friction Reducer, Iron Control Agent, Myacide|TS GA 25, Fluid Loss Additive , Propping Agent Formaldehyde 50-00-0 0.00001000 0 0
Hexadec-1-ene 629-73-2 0.00023 0.00003000 0
Water (Including Mix Water Supplied by Client)* NA 0 87.0327 0
Acrylamide, 2-acrylamido-2-methylpropanesulfonic
acid, sodium salt polymer
38193-60-1 0.05644 0.00732 0
Fatty acids, tall-oil 61790-12-3 0.00262 0.00034 0
Trisodium ortho phosphate 7601-54-9 0.00604 0.00078 0
Thiourea, polymer with formaldehyde and 1-phenylethanone 68527-49-1 0.00217 0.00028 0
Sodium erythorbate 6381-77-7 0.00735 0.00095 0
Dodecamethylcyclohexasiloxane 540-97-6 0 0 0
Ammonium sulfate 7783-20-2 0.07646 0.00992 0
Ethylene Glycol 107-21-1 0.00172 0.00022 0
Quartz, Crystalline silica 14808-60-7 98.3986 12.7596 0
Urea 57-13-6 0.00371 0.00048 0
2-propenamid 79-06-1 0.00018 0.00002000 0
Decamethyl cyclopentasiloxane 541-02-6 0 0 0
Octamethylcyclotetrasiloxane 556-67-2 0.00001000 0 0
Siloxanes and silicones, dimethyl,
reaction products with silica
67762-90-7 0.00001000 0 0
Methanol 67-56-1 0.00376 0.00049 0
Glutaraldehyde 111-30-8 0.25441 0.03299 0
Tetrasodium ethylenediaminetetraacetate 64-02-8 0.0001 0.00001000 0
Sodium sulfate 7757-82-6 0.00087 0.00011 0
Alcohols, C14-15, ethoxylated (7EO) 68951-67-7 0.00103 0.00013 0
Ethanol, 2,2',2-nitrilotris-,
1,1',1
-tris(dihydrogen phosphate), sodium salt
68171-29-9 0.01374 0.00178 0
Dimethyl siloxanes and silicones 63148-62-9 0.00005000 0.00001000 0
Diammonium peroxidisulphate 7727-54-0 0.00724 0.00094 0
Propargyl alcohol 107-19-7 0.00068 0.00009000 0
Copper(II) sulfate 7758-98-7 0 0 0
Polymer of 2-acrylamido-2-methylpropanesulfonic
acid sodium salt and methyl acrylate
136793-29-8 0.00605 0.00078 0
1-Octadecene (C18) 112-88-9 0.00011 0.00001000 0
Silicon Dioxide 7631-86-9 0.00077 0.0001 0
Hydrochloric acid 7647-01-0 1.15489 0.14976 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 EM ENERGY PA LLC 0.00 0 0.00 0 0.00 0
2015 EM ENERGY PA LLC 165,058.91 67 0.00 0 709.19 67
2016 EM ENERGY PA LLC 493,406.11 364 0.00 0 990.26 364
2017 EM ENERGY PA LLC 297,936.78 350 0.00 0 802.35 350
2018 EM ENERGY PA LLC 179,409.76 267 0.00 0 452.99 267
2019 EM ENERGY PA LLC 10,615.35 13 0.00 0 133.19 13

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 EM ENERGY PA LLC Drill Cuttings 21.41 Tons LANDFILL 100585
2015 EM ENERGY PA LLC Drilling Fluid Waste 280.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2015 EM ENERGY PA LLC Drill Cuttings 936.82 Tons LANDFILL SWF 1025
2015 EM ENERGY PA LLC Drilling Fluid Waste 430.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 EM ENERGY PA LLC Fracing Fluid Waste 1,466.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2015 EM ENERGY PA LLC Fracing Fluid Waste 2,158.13 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EM ENERGY PA LLC Filter Socks 0.04 Tons LANDFILL 073 114 654
2016 EM ENERGY PA LLC Waste Water Treatment Sludge 2.04 Tons LANDFILL 100585
2016 EM ENERGY PA LLC Waste Water Treatment Sludge 0.23 Tons LANDFILL 100594
2016 EM ENERGY PA LLC Produced Fluid 6.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 EM ENERGY PA LLC Waste Water Treatment Sludge 3.67 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2017 EM ENERGY PA LLC Other Oil & Gas Wastes 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EM ENERGY PA LLC Other Oil & Gas Wastes 33.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 EM ENERGY PA LLC Produced Fluid 634.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 EM ENERGY PA LLC Produced Fluid 1,013.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 EM ENERGY PA LLC Produced Fluid 3,169.28 Bbl REUSE (AT WELL PAD)
2017 EM ENERGY PA LLC Produced Fluid 219.18 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2017 EM ENERGY PA LLC Produced Fluid 3,279.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 EM ENERGY PA LLC Other Oil & Gas Wastes 4.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EM ENERGY PA LLC Produced Fluid 38.51 Bbl INJECTION DISPOSAL WELL 34-155-24063
2018 EM ENERGY PA LLC Produced Fluid 625.01 Bbl REUSE (AT WELL PAD)
2018 EM ENERGY PA LLC Produced Fluid 27.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 EM ENERGY PA LLC Produced Fluid 198.16 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018 EM ENERGY PA LLC Produced Fluid 109.65 Bbl INJECTION DISPOSAL WELL 34-155-24079
2018 EM ENERGY PA LLC Produced Fluid 285.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 EM ENERGY PA LLC Produced Fluid 34.64 Bbl INJECTION DISPOSAL WELL 34-155-24063
2019 EM ENERGY PA LLC Produced Fluid 35.80 Bbl REUSE (AT WELL PAD)
2019 EM ENERGY PA LLC Produced Fluid 135.27 Bbl INJECTION DISPOSAL WELL 34-155-24079

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2330531 Primary Facility 2014-12-17 Routine/Partial Inspection No Violations Noted
2340054 Primary Facility 2015-01-28 Routine/Partial Inspection No Violations Noted
2346606 Primary Facility 2015-02-19 Routine/Partial Inspection No Violations Noted
2514174 Primary Facility 2016-08-24 Routine/Partial Inspection No Violations Noted
2601703 Primary Facility 2017-06-07 Routine/Partial Inspection No Violations Noted On site for a partial inspection.

Well has been drilled and completed. Well in production.

All production equipment on site. Production tanks on containment. GPUs on site. Gathering pipeline header on site.

Well tag in place.

Well development impoundment has been restored

All E/S controls in place, intact, and functioning. Good Vegetation growth noted.

2654667 Primary Facility 2017-10-31 Routine/Partial Inspection No Violations Noted On site for a routine partial inspection.

Well is drilled, completed, and in production. Well head protected by gate. Well tag in place. Tank battery and GPUs on secondary containment. A combustor and a gathering pipeline header on site. Wells and production equipment are fenced and locked. Site ID sign in place with drilling permits on site.

Site has been restored and PCSM plan and BMPs installed, intact, and functioning. Site is stabilized with vegetation growth. ESCGP has been NOT'd.

For data sources see[8]

References