X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-105-21683"

m
m
 
(13 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{| class="wikitable" width="95%"
+
{| class="wikitable welldetails" width="95%"
| Well ID: 42-105-21683
+
| Well ID: 37-105-21683
| style="width: 50%; height=100%; align=center" rowspan="14" | {{#display_map: 41.8468, -78.156469 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.8468, -78.156469 | width=100% | height=100% }}
 +
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 +
|-
 +
| County: [[Potter_County,_Pennsylvania|Potter]]
 
|-
 
|-
| County: [[Potter County, Pennsylvania|Potter]]
+
| Municipality: [[Pleasant Valley Township,_Potter_County,_Pennsylvania|Pleasant Valley Township]]
 
|-
 
|-
| Municipality: [[Pleasant Valley Township, Potter County, Pennsylvania|Pleasant Valley Township]]
+
| Operator Name: [[PA GEN ENERGY CO LLC]]
 
|-
 
|-
| Operator Name: [[PA GEN ENERGY CO LLC|PA GEN ENERGY CO LLC]]
+
| Well Pad ID: [[148343]]
 
|-
 
|-
| Farm/Lease Name: FISK HOLLOW PAD A 2449
+
| Farm/Lease Name: FISK HOLLOW - PAD A
 
|-
 
|-
| First Permit Date: 2010-06-02
+
| License Status:  
 
|-
 
|-
| Last Permit Date: 2010-06-02
+
| Spud Date:  
 
|-
 
|-
| Spud Date: 2010-07-04
+
| Permit Date: 2010-06-02
 
|-
 
|-
| Unconventional: Yes
+
| Well Type: GAS
 
|-
 
|-
| Horizontal: Yes
+
| Unconventional Well: Y
 
|-
 
|-
| Producing: Yes
+
| Configuration: Horizontal Well
 
|-
 
|-
| Violations: 1
+
| Conservation: No
 
|-
 
|-
 
| Latitude: 41.8468
 
| Latitude: 41.8468
 
|-
 
|-
 
| Longitude: -78.156469
 
| Longitude: -78.156469
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2010-06-02
 +
| New Permit Application
 +
|-
 +
| 2010-07-04
 +
| Performed Spud Operation
 +
|-
 +
| 2010-09-28
 +
| Drilling Completion
 +
|-
 +
| 2010-12-19
 +
| Perforation
 +
|-
 +
| 2011-03-04
 +
| DEVIATED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2010-11-30
 +
| 2010-11-30
 +
| style="text-align: right;" | 5,800
 +
| style="text-align: right;" | 6,165,461
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
__TOC__
+
==== Fluid Composition Data ====
== Well Inspection Data ==
 
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" | Job Number
!scope="col" | DATE
+
!scope="col" | Trade Name
!scope="col" | DESCRIPTION
+
!scope="col" | Supplier
!scope="col" | COMMENT
+
!scope="col" | Purpose
!scope="col" | VIOLATION ID
+
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 1946131
+
|- valign="top"
| 2011-01-27
+
| rowspan="19"| 1
| No Violations Noted
+
| rowspan="12"|
|  
+
| rowspan="12"|
|  
+
| rowspan="12"|
 +
| Propylene Glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 25.0
 +
| style="text-align: right;" | 0.02042
 +
| style="text-align: right;" |
 +
|-
 +
| Diethylene Glycol
 +
| 111-46-6
 +
| style="text-align: right;" | 3.5
 +
| style="text-align: right;" | 0.00032
 +
| style="text-align: right;" |
 +
|-
 +
| Anionic copolymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00104
 +
| style="text-align: right;" |
 +
|-
 +
| Ethoxylated Alcohols
 +
| 68551-12-2
 +
| style="text-align: right;" | 4.0
 +
| style="text-align: right;" | 0.00327
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene Glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 1.0
 +
| style="text-align: right;" | 0.00906
 +
| style="text-align: right;" |
 +
|-
 +
| Mineral Spirits
 +
| 8052-41-3
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00817
 +
| style="text-align: right;" |
 +
|-
 +
| Polyethylene Glycol
 +
| 25322-68-3
 +
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00453
 +
| style="text-align: right;" |
 +
|-
 +
| 2-Phosphonobutane-1,2,4 tricarboxylic acid
 +
| 37971-36-1
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00104
 +
| style="text-align: right;" |
 +
|-
 +
| Anionic polymer
 +
| Proprietary
 +
| style="text-align: right;" | 10.0
 +
| style="text-align: right;" | 0.00104
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropyl Alcohol
 +
| 67-63-0
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Component
 +
| Proprietary
 +
| style="text-align: right;" | 7.0
 +
| style="text-align: right;" | 0.00002000
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
| Propargyl Alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 
|-
 
|-
| 1972510
+
|- valign="top"
| 2011-05-12
+
| rowspan="1"| KR-153SL
| No Violations Noted
+
| rowspan="1"| Superior Well Services
|  
+
| rowspan="1"| Biocide
|  
+
| 2,2-Dibromo-3-nitrilo-propionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.0
 +
| style="text-align: right;" | 0.00181
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Acid, Hydrochloric (3)
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Solvent
 +
| Hydrochloric Acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 3.0
 +
| style="text-align: right;" | 0.04218
 +
| style="text-align: right;" |
 
|-
 
|-
| 2045184
+
|- valign="top"
| 2012-02-24
+
| rowspan="1"| Super TSC
| No Violations Noted
+
| rowspan="1"| Superior Well Services
| An inspection was conducted at the Fisk Hollow Pad A on Feb. 24, 2012.  The ground was frozen and snow covered.  The site ID sign and E&S plan and site perimeter were observed.  The collection systems for production fluid were also observed.  There were no erosion issues or leaks and spills detected.  No new violations were cited during this inspection. - MRN
+
| rowspan="1"| Scale Inhibitor
|  
+
| Propylene glycol
 +
| 57-55-6
 +
| style="text-align: right;" | 50.0
 +
| style="text-align: right;" | 0.00518
 +
| style="text-align: right;" |  
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| AI -2
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Acid Inhibitor
 +
| Glycol Ether
 +
| 111-76-2
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.00009000
 +
| style="text-align: right;" |
 
|-
 
|-
| 2106234
+
|- valign="top"
| 2012-10-10
+
| rowspan="1"| Water*
| No Violations Noted
+
| rowspan="1"| PGE
|  
+
| rowspan="1"| Carrier/Base Fluid
 
|  
 
|  
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 84.26914
 +
| style="text-align: right;" |
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Superior Well Services
 +
| rowspan="1"| Proppant
 +
| Crystalline Silica (quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.0
 +
| style="text-align: right;" | 14.22334
 +
| style="text-align: right;" |
 
|-
 
|-
| 2127877
+
|- valign="top"
| 2012-12-11
+
| rowspan="1"| WFR-3B
| Violation(s) Noted
+
| rowspan="1"| Superior Well Services
|  
+
| rowspan="1"| Friction Reducer
| 657137
+
| Hydrotreated Light Distillate
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.0
 +
| style="text-align: right;" | 0.02451
 +
| style="text-align: right;" |
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
<!--== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Operator Name
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Gas Quantity (mcf)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Gas Production Days
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Oil Quantity (bbl)
!scope="col" | OIL QUANTITY
+
!scope="col" | Oil Production Days
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" | Water Quantity (bbl)
|-
+
!scope="col" | Water Production Days
| 2012-2
 
| style="text-align:right;" | 161794.0
 
| style="text-align:right;" | 184.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2012-1
+
| 2011
| style="text-align:right;" | 198415.0
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 182.0
+
| style="text-align: right;" | 422,679.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 313
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 360,209.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-2
+
| 2013
| style="text-align:right;" | 240752.0
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 184.0
+
| style="text-align: right;" | 262,194.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 212,869.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2011-1
+
| 2015
| style="text-align:right;" | 181927.0
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 129.0
+
| style="text-align: right;" | 164,059.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 365
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 142,256.00
 +
| style="text-align: right;" | 366
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-2
+
| 2017
| style="text-align:right;" | 0.0
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 133,506.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 364
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| style="text-align: right;" | 123,622.00
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| 2010-3
+
| 2019
| style="text-align:right;" | 0.0
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 124,319.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 351
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
== Waste Data ==
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | TYPE
+
!scope="col" | Operator
!scope="col" | QUANTITY
+
!scope="col" | Waste Type
!scope="col" | UNITS
+
!scope="col" | Quantity
!scope="col" | DISPOSAL METHOD
+
!scope="col" | Disposal Method
!scope="col" | WASTE FACILITY PERMIT ID
+
!scope="col" | Waste Facility ID
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
| 2012-2
+
| 2010
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 60.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 273.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0101508
 +
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 67.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0101508
 +
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 251.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 +
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 6,642.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 +
|-
 +
| 2010
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Drill Cuttings
 +
| style="text-align: right;" | 605.53 Tons
 +
| LANDFILL
 +
| 100361
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 595.77 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-21076
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 883.11 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-007-24355
+
| 34-007-24355
| B & B OILFIELD SERVICE - MILLER & CO #3 (SWIW #28)
+
|-
| GARRETTSVILLE
+
| 2011
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 539.81 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 34-099-23127
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Fracturing Fluid Waste
 +
| style="text-align: right;" | 9.11 Tons
 +
| LANDFILL
 +
| 100361
 
|-
 
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Fracing Fluid Waste
 +
| style="text-align: right;" | 112.70 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 
|-
 
|-
| 2012-2
+
| 2011
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 242.0
+
| Fracturing Fluid Waste
| Bbl
+
| style="text-align: right;" | 27.43 Tons
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 004835146
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 4,108.57 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 13,098.93 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-151-23420
+
| UIC 45
| B & B WELL # 2 (BELDEN & BLAKE)
 
| HARTVILLE
 
| OH
 
 
|-
 
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Drilling Fluid Waste
 +
| style="text-align: right;" | 1,734.29 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| PA0102784
 +
|-
 +
| 2011
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 222.52 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-24096
 
|-
 
|-
| 2012-2
+
| 2011
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 566.0
+
| Fracing Fluid Waste
| Bbl
+
| style="text-align: right;" | 1,918.89 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| WMGR0123
+
| PA0101508
| HYDRO RECOVERY - BLOSSBURG
 
| BLOSSBURG
 
| PA
 
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,070.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21447
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 976.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 3,033.50 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21438
+
| 34-155-21893
| KLEESE #1 (SWIW #18) - KLEESE DEVELOPMENT ASSOCS
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 566.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1040.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,487.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21447
+
| 34-151-23420
| KLEESE #2 (SWIW #19) - KLEESE DEVELOPMENT ASSOCS
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,380.00 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| 525-1
 +
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 4,368.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23795
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 2748.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,036.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-23795
+
| 34-155-21438
| PANDER #1 (SWIW #15)
+
|-
| NEWTON FALLS
+
| 2012
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,851.42 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|  
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 60.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-24355
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1454.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,076.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-133-20525
+
| 34-155-21894
| PANDER RAY TRUCKING INC - BLAZEK #2 SWIW
 
| HIRAM
 
| OH
 
 
|-
 
|-
 +
| 2012
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,454.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-20525
 
|-
 
|-
| 2012-2
+
| 2012
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 135.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,076.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,169.31 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
 
|
 
|
 
 
|-
 
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,658.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23795
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 813.85 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 60.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23732
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 40.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-151-21198
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 80.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21438
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 58.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 813.85 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,366.57 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-151-23420
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 813.83 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21893
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 80.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-24355
 +
|-
 +
| 2013
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,210.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-20525
 +
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 152.79 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 
|-
 
|-
| 2012-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1076.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 236.67 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21893
+
| 34-155-23759
| WOLF #1 DISP WELL (PANDER RAY TRUCKING INC)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 673.41 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23732
 
|-
 
|-
| 2012-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1076.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 340.03 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21894
+
| 34-155-23196
| WOLF #2 DISPOSAL WELL (PANDER RAY TRUCKING INC)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,140.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2012-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1076.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 239.17 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-23203
+
| 34-155-23223
| WOLF #4 DISPOSAL WELL (PANDER RAY TRUCKING INC)
 
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 333.33 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21447
 
|-
 
|-
| 2010-2
+
| 2014
| DRILL CUTTINGS
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 605.53
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 2,021.00 Bbl
| LANDFILL
+
| INJECTION DISPOSAL WELL
| 100361
+
| 34-007-21847
| MCKEAN COUNTY LANDFILL/RUSTICK, LLC
 
| KANE
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 152.79 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21893
 
|-
 
|-
| 2010-2
+
| 2014
| DRILLING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 67.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 120.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0101508
+
| 34-151-23420
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 152.79 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-23203
 
|-
 
|-
| 2010-2
+
| 2014
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 273.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 275.83 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0101508
+
| 34-155-23795
| PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO
 
| FRANKLIN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 20.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-22403
 
|-
 
|-
| 2010-2
+
| 2014
| DRILLING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 6642.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 216.67 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| PA0102784
+
| 34-155-21438
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
 +
| 2014
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 280.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-133-20525
 
|-
 
|-
| 2010-2
+
| 2015
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 251.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 369.33 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| PA0102784
+
| WMGR123NC010
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 6.67 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21893
 
|-
 
|-
| 2011-1
+
| 2015
| FLOWBACK FRACTURING SAND
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 27.43
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 6.67 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| INJECTION DISPOSAL WELL
| 004835146
+
| 34-155-23203
| MAX ENVIRONMENTAL
 
| PITTSBURGH
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 6.67 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-155-21894
 
|-
 
|-
| 2011-1
+
| 2015
| FLOWBACK FRACTURING SAND
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 9.11
+
| Produced Fluid
| Tons
+
| style="text-align: right;" | 119.83 Bbl
| LANDFILL
+
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT)
| 100361
+
| WMGR123
| MCKEAN COUNTY LANDFILL/RUSTICK, LLC
 
| KANE
 
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,155.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-21847
 
|-
 
|-
| 2011-1
+
| 2015
| FRACING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1918.89
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 1,678.00 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| REUSE OTHER THAN ROAD SPREADING
| PA0101508
 
| PA BRINE
 
 
|  
 
|  
| PA
 
 
|-
 
|-
 +
| 2015
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,305.33 Bbl
 +
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW011
 
|-
 
|-
| 2011-1
+
| 2015
| DRILLING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1734.29
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 223.17 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 +
| WMGR123NW005
 +
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 102.33 Bbl
 +
| CENT WASTE TRT FAC NPDES DISCHARGE
 
| PA0102784
 
| PA0102784
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 7.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-23262
 +
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 7.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-2-3177
 +
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 70.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-21847
 +
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 7.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-2-3692
 
|-
 
|-
| 2011-1
+
| 2016
| FRACING FLUID WASTE
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 112.7
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 266.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| PA0102784
+
| WMGR123NW005
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
|-
 
 
|-
 
|-
| 2011-1
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 4108.57
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 3,446.50 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
| PA0102784
+
| WMGR123NW011
| WASTE TREATMENT CORPORATION
 
| WARREN
 
| PA
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 7.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-2-3097
 
|-
 
|-
| 2011-2
+
| 2016
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 883.11
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 7.00 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-007-24355
+
| 34-007-24355
| B & B OILFIELD SERVICE - MILLER & CO #3 (SWIW #28)
 
| GARRETTSVILLE
 
| OH
 
 
|-
 
|-
 +
| 2016
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 102.33 Bbl
 +
| CENT WASTE TRT FAC NPDES
 +
| PA0102784
 
|-
 
|-
| 2011-2
+
| 2017
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 539.81
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 3,155.68 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-42-099-23127
+
| WMGR123NW011
| NORTH STAR BRINE DISPOSAL
 
| YOUNGSTOWN
 
| OH
 
 
|-
 
|-
 +
| 2017
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Soil Contaminated by Oil & Gas Related Spills
 +
| style="text-align: right;" | 0.03 Tons
 +
| LANDFILL
 +
| 101397
 
|-
 
|-
| 2011-2
+
| 2017
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 13098.93
+
| Soil Contaminated by Oil
| Bbl
+
| style="text-align: right;" | 0.03 Tons
| INJECTION DISPOSAL WELL
+
| LANDFILL
| UIC 45
+
| 101397
| RAY PANDER TRUCKING INC
 
| DIAMOND
 
| OH
 
 
|-
 
|-
 +
| 2017
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 89.17 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW005
 
|-
 
|-
| 2011-2
+
| 2017
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 222.52
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 18.33 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-42-133-24096
+
| WMGR123NC010
| SALTYS DISPOSAL - GROSELLE INECTION WELL # 2
 
| GARRETTSVILLE
 
| OH
 
 
|-
 
|-
 +
| 2017
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 134.17 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
| 2011-2
+
| 2018
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 595.77
+
| Other Oil & Gas Wastes
| Bbl
+
| style="text-align: right;" | 45.00 Bbl
| INJECTION DISPOSAL WELL
+
| RESIDUAL WASTE PROCESSING FACILITY
| 34-42-133-21076
+
| WMGR123NW011
| SALTYS DISPOSAL - MYERS INECTION WELL #1
 
| PARIS
 
| OH
 
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 2,230.51 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 
|-
 
|-
| 2012-1
+
| 2018
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1245.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 395.01 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-151-23420
+
| 34-007-21847
| B & B WELL # 2 (BELDEN & BLAKE)
 
| HARTVILLE
 
| OH
 
 
|-
 
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 35.83 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NC010
 +
|-
 +
| 2018
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 544.15 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2012-1
+
| 2018
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 2380.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 154.16 Bbl
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
+
| RESIDUAL WASTE PROCESSING FACILITY
| 525-1
+
| WMGR123NW005
| BLAZEK PUMP AND WELL
 
| HIRAM
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 54.99 Bbl
 +
| REUSE (AT WELL PAD)
 +
|
 
|-
 
|-
| 2012-1
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 60.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 271.66 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21438
+
| 34-155-24079
| KLEESE #1 (SWIW #18) - KLEESE DEVELOPMENT ASSOCS
 
| VIENNA
 
| OH
 
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 1,084.84 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| PAS2D215BWAR
 
|-
 
|-
| 2012-1
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 30.0
+
| Produced Fluid
| Bbl
+
| style="text-align: right;" | 833.33 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-21447
+
| 34-007-21847
| KLEESE #2 (SWIW #19) - KLEESE DEVELOPMENT ASSOCS
+
|-
| VIENNA
+
| 2019
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 375.83 Bbl
 +
| REUSE (AT WELL PAD)
 +
|  
 
|-
 
|-
 +
| 2019
 +
| [[PA GEN ENERGY CO LLC]]
 +
| Other Oil & Gas Wastes
 +
| style="text-align: right;" | 12.50 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-007-21847
 
|-
 
|-
| 2012-1
+
| 2019
| PRODUCED FLUID
+
| [[PA GEN ENERGY CO LLC]]
| style="text-align:right;" | 1620.5
+
| Other Oil & Gas Wastes
| Bbl
+
| style="text-align: right;" | 3.33 Bbl
 
| INJECTION DISPOSAL WELL
 
| INJECTION DISPOSAL WELL
| 34-42-155-23795
+
| PAS2D215BWAR
| PANDER #1 (SWIW #15)
+
|-
| NEWTON FALLS
+
| 2019
| OH
+
| [[PA GEN ENERGY CO LLC]]
 +
| Produced Fluid
 +
| style="text-align: right;" | 220.00 Bbl
 +
| RESIDUAL WASTE PROCESSING FACILITY
 +
| WMGR123NW011
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Waste Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 +
| 1946131
 +
| Primary Facility
 +
| 2011-01-27
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 2012-1
+
| 1972510
| PRODUCED FLUID
+
| Primary Facility
| style="text-align:right;" | 1716.42
+
| 2011-05-12
| Bbl
+
| Routine/Partial Inspection
| REUSE OTHER THAN ROAD SPREADING
+
| No Violations Noted
 +
|
 +
|-
 +
| 2045184
 +
| Primary Facility
 +
| 2012-02-24
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| An inspection was conducted at the Fisk Hollow Pad A on Feb. 24, 2012.  The ground was frozen and snow covered.  The site ID sign and E&S plan and site perimeter were observed.  The collection systems for production fluid were also observed.  There were no erosion issues or leaks and spills detected.  No new violations were cited during this inspection. - MRN
 +
|-
 +
| 2106234
 +
| Primary Facility
 +
| 2012-10-10
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 2127877
 +
| Primary Facility
 +
| 2012-12-11
 +
| Follow-up Inspection
 +
| Violation(s) Noted
 
|  
 
|  
| REUSE FOR HYDRAULIC FRACTURING
+
|-
 +
| 2221377
 +
| Primary Facility
 +
| 2013-11-12
 +
| Routine/Partial Inspection
 +
| No Violations Noted
 +
| A routine partial inspection of the Fisk Hollow Pleasant Valley Pad A site in Pleasant Valley Township, Potter County was conducted on 11/12/13, 2013 in response to a Notice of Termination and Well Site Restoration Reports received by the Department.    The FH1949 (105-21302) well has been plugged.  Six other wells are in production.  The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization at this time.  A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed.  Other areas are stabilized with stone.  The Well Site Restoration Report will be approved at this time.  The approval of the Notice of Termination will be recommended.  No violations were cited during this inspection.
 +
|-
 +
| 2485769
 +
| Primary Facility
 +
| 2016-05-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 +
|-
 +
| 2529268
 +
| Primary Facility
 +
| 2016-10-13
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Routine inspection at Fisk Hollow Pleasant Valley Pad A. Site is stable, no erosion issues noted or evidence of spills/releases. TLT
 +
|-
 +
| 2556020
 +
| Primary Facility
 +
| 2017-01-26
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 
|  
 
|  
 
|-
 
|-
 +
| 2631715
 +
| Primary Facility
 +
| 2017-08-29
 +
| Incident- Response to Accident or Event
 +
| No Violations Noted
 +
| On 8/29/17 at 1014 hrs I conducted an inspection at the Fisk Hollow Pad A well site to follow up on a small spill (less than 1 barrel) that was reported by PGE. It was mostly cloudy and 59 degrees F.
 +
 +
On 8/24/17 Amber Oyler, PGE Environmental Manager, contacted the Department of Environmental Protection (DEP) to report that approximately 25 gallons of hydraulic oil had been released to the pad surface at the Fisk Hollow pad A well site. She stated that she was notified of the spill at 1030 hrs on 8/24/17 by personnel at the site. At that time, absorbent pads were being used to soak up standing liquid. She stated that affected pad material would be removed and sent for disposal.
 +
 +
On 8/25/17, Ms. Oyler provided an update by email and included a photo to document that the spill had been cleaned up.
 +
 +
During my inspection, I observed the well pad and spill area. A new area of gravel was observed on the well pad to the southwest of the compressor building. It was apparent that pad soil had been removed in the spil
 +
|-
 +
| 2699987
 +
| Primary Facility
 +
| 2018-02-20
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of this inspection this well was in production. The wellhead assembly ,all fittings, flow lines and the cellar were tested for gas. The results of this testing was that no gas was detected on the wellhead assembly or the well area.
 +
|-
 +
| 2733573
 +
| Primary Facility
 +
| 2018-05-18
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| At the time of this inspection this well was in production
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 2012-1
+
| 2127877
| PRODUCED FLUID
+
| 657137
| style="text-align:right;" | 1957.5
+
| 12/11/2012
| Bbl
+
| 2012-12-11
| INJECTION DISPOSAL WELL
+
| 201H - Failure to properly install the permit number, issued by the department, on a completed well.
| 34-42-155-21893
+
| Administrative
| WOLF #1 DISP WELL (PANDER RAY TRUCKING INC)
+
|  
| NEWTON FALLS
 
| OH
 
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 
==References==
 
==References==
{{Reflist}}
+
<references/>
 
 
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Latest revision as of 11:56, 2 June 2020

Well Details

Well ID: 37-105-21683
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Pleasant Valley Township
Operator Name: PA GEN ENERGY CO LLC
Well Pad ID: 148343
Farm/Lease Name: FISK HOLLOW - PAD A
License Status:
Spud Date:
Permit Date: 2010-06-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.8468
Longitude: -78.156469

For data sources see[1][2][3]

Well History

Date Event
2010-06-02 New Permit Application
2010-07-04 Performed Spud Operation
2010-09-28 Drilling Completion
2010-12-19 Perforation
2011-03-04 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2010-11-30 2010-11-30 5,800 6,165,461

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Propylene Glycol 57-55-6 25.0 0.02042
Diethylene Glycol 111-46-6 3.5 0.00032
Anionic copolymer Proprietary 10.0 0.00104
Ethoxylated Alcohols 68551-12-2 4.0 0.00327
Ethylene Glycol 107-21-1 1.0 0.00906
Mineral Spirits 8052-41-3 10.0 0.00817
Polyethylene Glycol 25322-68-3 50.0 0.00453
2-Phosphonobutane-1,2,4 tricarboxylic acid 37971-36-1 10.0 0.00104
Anionic polymer Proprietary 10.0 0.00104
Isopropyl Alcohol 67-63-0 30.0 0.00009000
Proprietary Component Proprietary 7.0 0.00002000
Propargyl Alcohol 107-19-7 30.0 0.00009000
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilo-propionamide 10222-01-2 20.0 0.00181
Acid, Hydrochloric (3) Superior Well Services Solvent Hydrochloric Acid 7647-01-0 3.0 0.04218
Super TSC Superior Well Services Scale Inhibitor Propylene glycol 57-55-6 50.0 0.00518
AI -2 Superior Well Services Acid Inhibitor Glycol Ether 111-76-2 30.0 0.00009000
Water* PGE Carrier/Base Fluid 7732-18-5 100.0 84.26914
Sand Superior Well Services Proppant Crystalline Silica (quartz) 14808-60-7 100.0 14.22334
WFR-3B Superior Well Services Friction Reducer Hydrotreated Light Distillate 64742-47-8 30.0 0.02451

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PA GEN ENERGY CO LLC 0.00 0 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 422,679.00 313 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 360,209.00 366 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 262,194.00 365 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 212,869.00 364 0.00 0 0.00 0
2015 PA GEN ENERGY CO LLC 164,059.00 365 0.00 0 0.00 0
2016 PA GEN ENERGY CO LLC 142,256.00 366 0.00 0 0.00 0
2017 PA GEN ENERGY CO LLC 133,506.00 364 0.00 0 0.00 0
2018 PA GEN ENERGY CO LLC 123,622.00 364 0.00 0 0.00 0
2019 PA GEN ENERGY CO LLC 124,319.00 351 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 PA GEN ENERGY CO LLC Produced Fluid 273.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 67.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010 PA GEN ENERGY CO LLC Produced Fluid 251.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 PA GEN ENERGY CO LLC Drilling Fluid Waste 6,642.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010 PA GEN ENERGY CO LLC Drill Cuttings 605.53 Tons LANDFILL 100361
2011 PA GEN ENERGY CO LLC Produced Fluid 595.77 Bbl INJECTION DISPOSAL WELL 34-133-21076
2011 PA GEN ENERGY CO LLC Produced Fluid 883.11 Bbl INJECTION DISPOSAL WELL 34-007-24355
2011 PA GEN ENERGY CO LLC Produced Fluid 539.81 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011 PA GEN ENERGY CO LLC Fracturing Fluid Waste 9.11 Tons LANDFILL 100361
2011 PA GEN ENERGY CO LLC Fracing Fluid Waste 112.70 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 PA GEN ENERGY CO LLC Fracturing Fluid Waste 27.43 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 004835146
2011 PA GEN ENERGY CO LLC Produced Fluid 4,108.57 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 PA GEN ENERGY CO LLC Produced Fluid 13,098.93 Bbl INJECTION DISPOSAL WELL UIC 45
2011 PA GEN ENERGY CO LLC Drilling Fluid Waste 1,734.29 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 PA GEN ENERGY CO LLC Produced Fluid 222.52 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011 PA GEN ENERGY CO LLC Fracing Fluid Waste 1,918.89 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 PA GEN ENERGY CO LLC Produced Fluid 1,070.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2012 PA GEN ENERGY CO LLC Produced Fluid 3,033.50 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012 PA GEN ENERGY CO LLC Produced Fluid 566.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012 PA GEN ENERGY CO LLC Produced Fluid 1,487.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012 PA GEN ENERGY CO LLC Produced Fluid 2,380.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 525-1
2012 PA GEN ENERGY CO LLC Produced Fluid 4,368.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 PA GEN ENERGY CO LLC Produced Fluid 1,036.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 PA GEN ENERGY CO LLC Produced Fluid 1,851.42 Bbl REUSE OTHER THAN ROAD SPREADING
2012 PA GEN ENERGY CO LLC Produced Fluid 60.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2012 PA GEN ENERGY CO LLC Produced Fluid 1,076.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012 PA GEN ENERGY CO LLC Produced Fluid 1,454.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2012 PA GEN ENERGY CO LLC Produced Fluid 1,076.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 PA GEN ENERGY CO LLC Produced Fluid 1,169.31 Bbl REUSE OTHER THAN ROAD SPREADING
2013 PA GEN ENERGY CO LLC Produced Fluid 2,658.33 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013 PA GEN ENERGY CO LLC Produced Fluid 813.85 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013 PA GEN ENERGY CO LLC Produced Fluid 60.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2013 PA GEN ENERGY CO LLC Produced Fluid 40.00 Bbl INJECTION DISPOSAL WELL 34-151-21198
2013 PA GEN ENERGY CO LLC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 PA GEN ENERGY CO LLC Produced Fluid 58.33 Bbl INJECTION DISPOSAL WELL 34-155-22403
2013 PA GEN ENERGY CO LLC Produced Fluid 813.85 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013 PA GEN ENERGY CO LLC Produced Fluid 1,366.57 Bbl INJECTION DISPOSAL WELL 34-151-23420
2013 PA GEN ENERGY CO LLC Produced Fluid 813.83 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 PA GEN ENERGY CO LLC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2013 PA GEN ENERGY CO LLC Produced Fluid 1,210.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2014 PA GEN ENERGY CO LLC Produced Fluid 152.79 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014 PA GEN ENERGY CO LLC Produced Fluid 236.67 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 PA GEN ENERGY CO LLC Produced Fluid 673.41 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014 PA GEN ENERGY CO LLC Produced Fluid 340.03 Bbl INJECTION DISPOSAL WELL 34-155-23196
2014 PA GEN ENERGY CO LLC Produced Fluid 1,140.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 PA GEN ENERGY CO LLC Produced Fluid 239.17 Bbl INJECTION DISPOSAL WELL 34-155-23223
2014 PA GEN ENERGY CO LLC Produced Fluid 333.33 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014 PA GEN ENERGY CO LLC Produced Fluid 2,021.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2014 PA GEN ENERGY CO LLC Produced Fluid 152.79 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 PA GEN ENERGY CO LLC Produced Fluid 120.00 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014 PA GEN ENERGY CO LLC Produced Fluid 152.79 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014 PA GEN ENERGY CO LLC Produced Fluid 275.83 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014 PA GEN ENERGY CO LLC Produced Fluid 20.00 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014 PA GEN ENERGY CO LLC Produced Fluid 216.67 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014 PA GEN ENERGY CO LLC Produced Fluid 280.00 Bbl INJECTION DISPOSAL WELL 34-133-20525
2015 PA GEN ENERGY CO LLC Produced Fluid 369.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 PA GEN ENERGY CO LLC Produced Fluid 6.67 Bbl INJECTION DISPOSAL WELL 34-155-21893
2015 PA GEN ENERGY CO LLC Produced Fluid 6.67 Bbl INJECTION DISPOSAL WELL 34-155-23203
2015 PA GEN ENERGY CO LLC Produced Fluid 6.67 Bbl INJECTION DISPOSAL WELL 34-155-21894
2015 PA GEN ENERGY CO LLC Produced Fluid 119.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 PA GEN ENERGY CO LLC Produced Fluid 1,155.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015 PA GEN ENERGY CO LLC Produced Fluid 1,678.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 PA GEN ENERGY CO LLC Produced Fluid 1,305.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 PA GEN ENERGY CO LLC Produced Fluid 223.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 PA GEN ENERGY CO LLC Produced Fluid 102.33 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0102784
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-23262
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2016 PA GEN ENERGY CO LLC Produced Fluid 70.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2016 PA GEN ENERGY CO LLC Produced Fluid 266.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 PA GEN ENERGY CO LLC Produced Fluid 3,446.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016 PA GEN ENERGY CO LLC Produced Fluid 7.00 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016 PA GEN ENERGY CO LLC Produced Fluid 102.33 Bbl CENT WASTE TRT FAC NPDES PA0102784
2017 PA GEN ENERGY CO LLC Produced Fluid 3,155.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 PA GEN ENERGY CO LLC Soil Contaminated by Oil & Gas Related Spills 0.03 Tons LANDFILL 101397
2017 PA GEN ENERGY CO LLC Soil Contaminated by Oil 0.03 Tons LANDFILL 101397
2017 PA GEN ENERGY CO LLC Produced Fluid 89.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 PA GEN ENERGY CO LLC Produced Fluid 18.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 134.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 45.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 2,230.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 PA GEN ENERGY CO LLC Produced Fluid 395.01 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 PA GEN ENERGY CO LLC Produced Fluid 35.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 PA GEN ENERGY CO LLC Produced Fluid 544.15 Bbl REUSE (AT WELL PAD)
2018 PA GEN ENERGY CO LLC Produced Fluid 154.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 54.99 Bbl REUSE (AT WELL PAD)
2019 PA GEN ENERGY CO LLC Produced Fluid 271.66 Bbl INJECTION DISPOSAL WELL 34-155-24079
2019 PA GEN ENERGY CO LLC Produced Fluid 1,084.84 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019 PA GEN ENERGY CO LLC Produced Fluid 833.33 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 PA GEN ENERGY CO LLC Produced Fluid 375.83 Bbl REUSE (AT WELL PAD)
2019 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 12.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019 PA GEN ENERGY CO LLC Other Oil & Gas Wastes 3.33 Bbl INJECTION DISPOSAL WELL PAS2D215BWAR
2019 PA GEN ENERGY CO LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1946131 Primary Facility 2011-01-27 Routine/Partial Inspection No Violations Noted
1972510 Primary Facility 2011-05-12 Routine/Partial Inspection No Violations Noted
2045184 Primary Facility 2012-02-24 Routine/Complete Inspection No Violations Noted An inspection was conducted at the Fisk Hollow Pad A on Feb. 24, 2012. The ground was frozen and snow covered. The site ID sign and E&S plan and site perimeter were observed. The collection systems for production fluid were also observed. There were no erosion issues or leaks and spills detected. No new violations were cited during this inspection. - MRN
2106234 Primary Facility 2012-10-10 Routine/Partial Inspection No Violations Noted
2127877 Primary Facility 2012-12-11 Follow-up Inspection Violation(s) Noted
2221377 Primary Facility 2013-11-12 Routine/Partial Inspection No Violations Noted A routine partial inspection of the Fisk Hollow Pleasant Valley Pad A site in Pleasant Valley Township, Potter County was conducted on 11/12/13, 2013 in response to a Notice of Termination and Well Site Restoration Reports received by the Department. The FH1949 (105-21302) well has been plugged. Six other wells are in production. The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization at this time. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed. Other areas are stabilized with stone. The Well Site Restoration Report will be approved at this time. The approval of the Notice of Termination will be recommended. No violations were cited during this inspection.
2485769 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted
2529268 Primary Facility 2016-10-13 Routine/Complete Inspection No Violations Noted Routine inspection at Fisk Hollow Pleasant Valley Pad A. Site is stable, no erosion issues noted or evidence of spills/releases. TLT
2556020 Primary Facility 2017-01-26 Routine/Complete Inspection No Violations Noted
2631715 Primary Facility 2017-08-29 Incident- Response to Accident or Event No Violations Noted On 8/29/17 at 1014 hrs I conducted an inspection at the Fisk Hollow Pad A well site to follow up on a small spill (less than 1 barrel) that was reported by PGE. It was mostly cloudy and 59 degrees F.

On 8/24/17 Amber Oyler, PGE Environmental Manager, contacted the Department of Environmental Protection (DEP) to report that approximately 25 gallons of hydraulic oil had been released to the pad surface at the Fisk Hollow pad A well site. She stated that she was notified of the spill at 1030 hrs on 8/24/17 by personnel at the site. At that time, absorbent pads were being used to soak up standing liquid. She stated that affected pad material would be removed and sent for disposal.

On 8/25/17, Ms. Oyler provided an update by email and included a photo to document that the spill had been cleaned up.

During my inspection, I observed the well pad and spill area. A new area of gravel was observed on the well pad to the southwest of the compressor building. It was apparent that pad soil had been removed in the spil

2699987 Primary Facility 2018-02-20 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly ,all fittings, flow lines and the cellar were tested for gas. The results of this testing was that no gas was detected on the wellhead assembly or the well area.
2733573 Primary Facility 2018-05-18 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2127877 657137 12/11/2012 2012-12-11 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative

For data sources see[8]

References