X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-049-25361"

(Created page with "== Well Details == {{049-25361-Details}} __TOC__ == Well Inspection Data == {{049-25361-inspection}} == Production Data == {{049-25361-production}} == Waste Data == {{049-2536...")
 
m
 
(17 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
__TOC__
 
== Well Details ==
 
== Well Details ==
{{049-25361-Details}}
+
{| class="wikitable welldetails" width="95%"
__TOC__
+
| Well ID: 37-049-25361
== Well Inspection Data ==
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.869116, -80.349086 | width=100% | height=100% }}
{{049-25361-inspection}}
+
|-
 +
| Country: United States
 +
|-
 +
| State: Pennsylvania
 +
|-
 +
| County: [[Erie_County,_Pennsylvania|Erie]]
 +
|-
 +
| Municipality: [[Elk Creek Township,_Erie_County,_Pennsylvania|Elk Creek Township]]
 +
|-
 +
| Operator Name: [[KASTLE RESOURCES ENTERPRISES INC]]
 +
|-
 +
| Well Pad ID:
 +
|-
 +
| Farm/Lease Name: GLAVIC UNIT 1
 +
|-
 +
| License Status: PLUGGED & ABANDONED
 +
|-
 +
| Spud Date:
 +
|-
 +
| Permit Date: 2009-11-17
 +
|-
 +
| Well Type: COMB. OIL&GAS
 +
|-
 +
| Unconventional Well: N
 +
|-
 +
| Configuration: Deviated Well
 +
|-
 +
| Conservation: Yes
 +
|-
 +
| Latitude: 41.869116
 +
|-
 +
| Longitude: -80.349086
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Date
 +
!scope="col" | Event
 +
|-
 +
| 2009-11-17
 +
| New Permit Application
 +
|-
 +
| 2009-12-01
 +
| Performed Spud Operation
 +
|-
 +
| 2009-12-26
 +
| Drilling Completion
 +
|-
 +
| 2010-02-09
 +
| Perforation
 +
|-
 +
| 2010-02-10
 +
| Performed Stimulation 
 +
|-
 +
| 2010-05-20
 +
| Drilling Completion
 +
|-
 +
| 2010-06-15
 +
| NEWLY DRILLED
 +
|-
 +
| 2011-06-13
 +
| FULLY PLUGGED
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources
 +
| date = 2020-02-27
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-02-27 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
 +
== Stimulation Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Stimulation Date
 +
!scope="col" | Phase Number
 +
!scope="col" | Chemical Agent
 +
!scope="col" | Volume (gal)
 +
!scope="col" | Treating Pressure (psi)
 +
!scope="col" | Breakdown Pressure (psi)
 +
|-
 +
| 2010-02-10
 +
| style="text-align: right;" |
 +
 
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Completion Reports - Stimulations
 +
| publisher = Pennsylvania Department of Conservation and Natural Resources
 +
| date = 2020-03-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2020-03-02 }}</ref>
 
== Production Data ==
 
== Production Data ==
{{049-25361-production}}
+
{| class="wikitable sortable" width="95%"
== Waste Data ==
+
!scope="col" | Period
{{049-25361-waste}}
+
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 +
|-
 +
| 2009
 +
| [[KASTLE RESOURCES ENTERPRISES INC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
| 2010
 +
| [[KASTLE RESOURCES ENTERPRISES INC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Waste Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator
 +
!scope="col" | Waste Type
 +
!scope="col" | Quantity
 +
!scope="col" | Disposal Method
 +
!scope="col" | Waste Facility ID
 +
|-
 +
|}-->
 +
 
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 +
|-
 +
| 1847319
 +
| Primary Facility
 +
| 2009-12-03
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1848046
 +
| Primary Facility
 +
| 2009-12-04
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1850006
 +
| Primary Facility
 +
| 2009-12-15
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1850010
 +
| Primary Facility
 +
| 2009-12-14
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1850539
 +
| Primary Facility
 +
| 2009-12-18
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1850858
 +
| Primary Facility
 +
| 2009-12-18
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1851758
 +
| Primary Facility
 +
| 2009-12-23
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1887010
 +
| Primary Facility
 +
| 2010-05-19
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
|
 +
|-
 +
| 1954904
 +
| Primary Facility
 +
| 2011-02-28
 +
| Routine/Complete Inspection
 +
| Violation(s) Noted
 +
|
 +
|-
 +
| 1955583
 +
| Primary Facility
 +
| 2011-03-08
 +
| Complaint Inspection
 +
| Violation(s) Noted
 +
| Today Jon Scott I completed a inspection of this site in response to a complaint received 2/28/2011 alleging the Glavic # 1 gas well was impacting the drinking water source. Upon arriving at the site I meet the complainant and completed the Water Supply Investigation Checklist.  Upon investigating I found the gas well site partially reclaimed, being unstable. The site had both surface water and ground water flowing across  bare earth, that had  pieces of pit liner, E&S fence, concrete and bentonite  mixed in to the dirt.  This water was pooling along side the access road, and several hemlock trees are dying in the area the water has pooled, and in the area of flow along side of the access road. The complainat's water source appears to be in line withe water flow; I suggested to the home owner that he not drink his water until we verify if it is safe. I collected a water sample for  a 942 series analysis, to determine if the gas well is impacting his source. I notified Kastle's Project Manager Scott Tipton, and setup a on-site meeting for 3/10/11.
 +
|-
 +
| 1956598
 +
| Primary Facility
 +
| 2011-03-10
 +
| Complaint Inspection
 +
| Violation(s) Noted
 +
| My inspection today was to visually check to see if water was running from the site  west across the access road into the stream. Upon inspection I found the water continues to run across the site carrying sediment and possible waste products, and pooling along the east side of the access road. The water was not overflowing thr access and running into the stream. Violations of 102.11 remain. I collected (3) water smapel to be run under the 942 series. One from the site and the others from pools of water that has run off the site. More info in my 3/10/11 inspection.
 +
|-
 +
| 1958930
 +
| Primary Facility
 +
| 2011-03-17
 +
| Complaint Inspection
 +
| Pending
 +
| Today Scott Lux and I met on-site with Kastle Rep¿s Scott Tipton and Kevin Saffell to review the apparent pollution event occurring in the area of this well site.  Upon examining the site and surrounding area, it was agreed that some type of pollutant is running off the site in the water and impacting/killing the trees that are in the flow path. The current thoughts are that when the site rock material was removed/reclaimed  in August 2010, contamination in the area was ¿stirred-up¿ and then flowed out of a tail drainage ditch (constructed at the same time) to the west and pooled along the access road. The pooled water then seeped through the ground and rock in the area flowing primarily to the south, towards the Sabol residence, impacting several trees along the way.  Mr Sabols¿ spring water source is directly in-line with the water flow.  A drinking water sample was collected.See my 3/17/2001 inspection report for more information.
 +
|-
 +
| 1991383
 +
| Primary Facility
 +
| 2011-07-26
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| Met on-site with Owner and sub contractor to review and discuss drill pit clean-up options. Explained to the owner/operator that he would either have to pump all fuilds out of the pit and take it and the liner to an approve waste site or dig a new pit and place the old liner and pit contents in it. I also explained i would ahve to see the old pit, after removing the material and before he back filled it.
 +
|-
 +
| 2002078
 +
| Primary Facility
 +
| 2011-09-08
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| Inspection to verify if the site reclaim work has been completed- upon inspection i found the gas well site reclaimed- with 90% of the ground suface cover with clover/grass- the access road is in good condition- the drainage culvert has been installed as required.
 +
|-
 +
| 2004625
 +
| Primary Facility
 +
| 2011-09-21
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| Today Scott Lux and I inspected this reclaimed site to determine if the restoration is complete. Upon inspeciton we found the site reclaimed as required. We did notice two small bare spots on the west side of the reclaimed site. Theses sies will be watched to see if the grass comes in as required.
 +
|-
 +
| 2007338
 +
| Primary Facility
 +
| 2011-09-28
 +
| Follow-up Inspection
 +
| Pending
 +
| Today's inspection was to check on the status of the revegation of  the barren areas of this reclaimed gas well site and to review the results of water and soil samples I had collected, with property owner Ken Sabol.  Upon isnpection I found the barren spot still did not have grass growing. I contacted Scott Tiption, of Kastle Resorces and explained that Kastle would have to remove the soil from this area and replace it with clean top soil, seed and mulch this fall or early next Spring. I will have to reinspect.
 +
|-
 +
| 2566306
 +
| Primary Facility
 +
| 2017-03-01
 +
| Administrative/File Review
 +
| No Violations Noted
 +
| Review of plugging certificate
 +
|-
 +
|}
 +
==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 +
|-
 +
| 1954904
 +
| 605925
 +
| 02/28/2011
 +
| 2011-02-28
 +
| 78.124 - Failure to submit plugging certificate 30 days after well plugged
 +
| Administrative
 +
|
 +
|-
 +
| 1955583
 +
| 606136
 +
| 03/08/2011
 +
| 2011-03-08
 +
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 +
| Administrative
 +
|
 +
|-
 +
| 1956598
 +
| 606371
 +
| 03/10/2011
 +
| 2011-03-10
 +
| 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation.
 +
| Administrative
 +
|
 +
|-
 +
|}
 +
==== Penalties Applied ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Violation ID
 +
!scope="col" | Penalty ID
 +
!scope="col" | Penalty Code
 +
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 +
|-
 +
| 605925
 +
| 268365
 +
| NOV - Notice of Violation
 +
| Comply/Closed
 +
|
 +
| 2011-04-06
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 +
[[Category:Pennsylvania Wells]]

Latest revision as of 16:17, 2 June 2020

Well Details

Well ID: 37-049-25361
Loading map...
Country: United States
State: Pennsylvania
County: Erie
Municipality: Elk Creek Township
Operator Name: KASTLE RESOURCES ENTERPRISES INC
Well Pad ID:
Farm/Lease Name: GLAVIC UNIT 1
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2009-11-17
Well Type: COMB. OIL&GAS
Unconventional Well: N
Configuration: Deviated Well
Conservation: Yes
Latitude: 41.869116
Longitude: -80.349086

For data sources see[1][2][3]

Well History

Date Event
2009-11-17 New Permit Application
2009-12-01 Performed Spud Operation
2009-12-26 Drilling Completion
2010-02-09 Perforation
2010-02-10 Performed Stimulation
2010-05-20 Drilling Completion
2010-06-15 NEWLY DRILLED
2011-06-13 FULLY PLUGGED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2010-02-10 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 KASTLE RESOURCES ENTERPRISES INC 0.00 0 0.00 0 0.00 0
2010 KASTLE RESOURCES ENTERPRISES INC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1847319 Primary Facility 2009-12-03 Drilling/Alteration No Violations Noted
1848046 Primary Facility 2009-12-04 Drilling/Alteration No Violations Noted
1850006 Primary Facility 2009-12-15 Drilling/Alteration No Violations Noted
1850010 Primary Facility 2009-12-14 Drilling/Alteration No Violations Noted
1850539 Primary Facility 2009-12-18 Drilling/Alteration No Violations Noted
1850858 Primary Facility 2009-12-18 Routine/Complete Inspection No Violations Noted
1851758 Primary Facility 2009-12-23 Drilling/Alteration No Violations Noted
1887010 Primary Facility 2010-05-19 Routine/Complete Inspection No Violations Noted
1954904 Primary Facility 2011-02-28 Routine/Complete Inspection Violation(s) Noted
1955583 Primary Facility 2011-03-08 Complaint Inspection Violation(s) Noted Today Jon Scott I completed a inspection of this site in response to a complaint received 2/28/2011 alleging the Glavic # 1 gas well was impacting the drinking water source. Upon arriving at the site I meet the complainant and completed the Water Supply Investigation Checklist. Upon investigating I found the gas well site partially reclaimed, being unstable. The site had both surface water and ground water flowing across bare earth, that had pieces of pit liner, E&S fence, concrete and bentonite mixed in to the dirt. This water was pooling along side the access road, and several hemlock trees are dying in the area the water has pooled, and in the area of flow along side of the access road. The complainat's water source appears to be in line withe water flow; I suggested to the home owner that he not drink his water until we verify if it is safe. I collected a water sample for a 942 series analysis, to determine if the gas well is impacting his source. I notified Kastle's Project Manager Scott Tipton, and setup a on-site meeting for 3/10/11.
1956598 Primary Facility 2011-03-10 Complaint Inspection Violation(s) Noted My inspection today was to visually check to see if water was running from the site west across the access road into the stream. Upon inspection I found the water continues to run across the site carrying sediment and possible waste products, and pooling along the east side of the access road. The water was not overflowing thr access and running into the stream. Violations of 102.11 remain. I collected (3) water smapel to be run under the 942 series. One from the site and the others from pools of water that has run off the site. More info in my 3/10/11 inspection.
1958930 Primary Facility 2011-03-17 Complaint Inspection Pending Today Scott Lux and I met on-site with Kastle Rep¿s Scott Tipton and Kevin Saffell to review the apparent pollution event occurring in the area of this well site. Upon examining the site and surrounding area, it was agreed that some type of pollutant is running off the site in the water and impacting/killing the trees that are in the flow path. The current thoughts are that when the site rock material was removed/reclaimed in August 2010, contamination in the area was ¿stirred-up¿ and then flowed out of a tail drainage ditch (constructed at the same time) to the west and pooled along the access road. The pooled water then seeped through the ground and rock in the area flowing primarily to the south, towards the Sabol residence, impacting several trees along the way. Mr Sabols¿ spring water source is directly in-line with the water flow. A drinking water sample was collected.See my 3/17/2001 inspection report for more information.
1991383 Primary Facility 2011-07-26 Follow-up Inspection No Violations Noted Met on-site with Owner and sub contractor to review and discuss drill pit clean-up options. Explained to the owner/operator that he would either have to pump all fuilds out of the pit and take it and the liner to an approve waste site or dig a new pit and place the old liner and pit contents in it. I also explained i would ahve to see the old pit, after removing the material and before he back filled it.
2002078 Primary Facility 2011-09-08 Follow-up Inspection No Violations Noted Inspection to verify if the site reclaim work has been completed- upon inspection i found the gas well site reclaimed- with 90% of the ground suface cover with clover/grass- the access road is in good condition- the drainage culvert has been installed as required.
2004625 Primary Facility 2011-09-21 Follow-up Inspection No Violations Noted Today Scott Lux and I inspected this reclaimed site to determine if the restoration is complete. Upon inspeciton we found the site reclaimed as required. We did notice two small bare spots on the west side of the reclaimed site. Theses sies will be watched to see if the grass comes in as required.
2007338 Primary Facility 2011-09-28 Follow-up Inspection Pending Today's inspection was to check on the status of the revegation of the barren areas of this reclaimed gas well site and to review the results of water and soil samples I had collected, with property owner Ken Sabol. Upon isnpection I found the barren spot still did not have grass growing. I contacted Scott Tiption, of Kastle Resorces and explained that Kastle would have to remove the soil from this area and replace it with clean top soil, seed and mulch this fall or early next Spring. I will have to reinspect.
2566306 Primary Facility 2017-03-01 Administrative/File Review No Violations Noted Review of plugging certificate

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1954904 605925 02/28/2011 2011-02-28 78.124 - Failure to submit plugging certificate 30 days after well plugged Administrative
1955583 606136 03/08/2011 2011-03-08 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative
1956598 606371 03/10/2011 2011-03-10 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
605925 268365 NOV - Notice of Violation Comply/Closed 2011-04-06

For data sources see[7]