If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-081-20421 | | Well ID: 37-081-20421 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="15" | {{#display_map: 41.257827, -76.516008 | width=100% | height=100% }} |
|- | |- | ||
| County: [[Lycoming County, Pennsylvania|Lycoming]] | | County: [[Lycoming County, Pennsylvania|Lycoming]] | ||
Line 9: | Line 9: | ||
| Municipality: [[Jordan Township, Lycoming County, Pennsylvania|Jordan Township]] | | Municipality: [[Jordan Township, Lycoming County, Pennsylvania|Jordan Township]] | ||
|- | |- | ||
− | | Operator Name: [[ | + | | Operator Name: [[XTO ENERGY INC]] |
+ | |- | ||
+ | | Well Pad ID: | ||
+ | |- | ||
+ | | Farm/Lease Name: SHANER 8507H | ||
|- | |- | ||
| First Permit Date: 2010-12-01 | | First Permit Date: 2010-12-01 | ||
Line 15: | Line 19: | ||
| Last Permit Date: 2010-12-01 | | Last Permit Date: 2010-12-01 | ||
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Unconventional: Yes | | Unconventional: Yes | ||
|- | |- | ||
| Horizontal: Yes | | Horizontal: Yes | ||
+ | |- | ||
+ | | Well Status: ACTIVE | ||
|- | |- | ||
| Violations: 16 | | Violations: 16 | ||
Line 28: | Line 34: | ||
|- | |- | ||
|} | |} | ||
+ | == Production Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | GAS QUANTITY | ||
+ | !scope="col" | GAS PRODUCTION DAYS | ||
+ | !scope="col" | CONDENSATE QUANTITY | ||
+ | !scope="col" | CONDENSATE PRODUCTION DAYS | ||
+ | !scope="col" | OIL QUANTITY | ||
+ | !scope="col" | OIL PRODUCTION DAYS | ||
+ | |- | ||
+ | | 2010-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2010-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-1 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |- | ||
+ | | 2011-2 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | | style="text-align:right;" | 0.0 | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Production Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production | ||
+ | | accessdate = 2015-05-27 }}</ref> | ||
+ | == Waste Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | PERIOD | ||
+ | !scope="col" | TYPE | ||
+ | !scope="col" | QUANTITY | ||
+ | !scope="col" | UNITS | ||
+ | !scope="col" | DISPOSAL METHOD | ||
+ | !scope="col" | WASTE FACILITY PERMIT ID | ||
+ | !scope="col" | WASTE FACILITY NAME | ||
+ | !scope="col" | FACILITY CITY | ||
+ | !scope="col" | FACILITY STATE | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Oil and Gas Historical Waste Report | ||
+ | | publisher = [[Pennsylvania Department of Environmental Protection]] | ||
+ | | date = 2015-05-26 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste | ||
+ | | accessdate = 2015-05-26 }}</ref> | ||
== Inspection Data == | == Inspection Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 35: | Line 111: | ||
!scope="col" | COMMENT | !scope="col" | COMMENT | ||
!scope="col" | VIOLATION ID | !scope="col" | VIOLATION ID | ||
+ | !scope="col" | VIOLATION CODE | ||
+ | !scope="col" | VIOLATION_COMMENT | ||
|- | |- | ||
| 1957465 | | 1957465 | ||
| 2011-03-08 | | 2011-03-08 | ||
| No Violations Noted | | No Violations Noted | ||
+ | | | ||
+ | | | ||
| | | | ||
| | | | ||
Line 48: | Line 128: | ||
| | | | ||
| 609456 | | 609456 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | | ||
|- | |- | ||
|- | |- | ||
Line 55: | Line 137: | ||
| | | | ||
| 609457 | | 609457 | ||
+ | | CSL401CAUSPL - Polluting substance(s) allowed to discharge into Waters of the Commonwealth | ||
+ | | Sediment pollution to waters of the Commonwealth | ||
|- | |- | ||
|- | |- | ||
Line 60: | Line 144: | ||
| 2011-05-31 | | 2011-05-31 | ||
| No Violations Noted | | No Violations Noted | ||
+ | | | ||
+ | | | ||
| | | | ||
| | | | ||
Line 69: | Line 155: | ||
| | | | ||
| 623529 | | 623529 | ||
+ | | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | ||
+ | | Erosion gully, W side road runs approx 1000'. No rock lining, no E&S apparent. E&S BMPs are not in place to minimize the potential for accelerated erosion. | ||
|- | |- | ||
|- | |- | ||
Line 76: | Line 164: | ||
| | | | ||
| 623530 | | 623530 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Access road, E side, rock-lined ditch. Toward base of road, ditch broken and extends into another erosion feature, perhaps a pre-existing ditch or intermittent stream. Erosion feature is choked with gravel and sediment from the road. E&S BMPs not maint. | ||
|- | |- | ||
|- | |- | ||
Line 83: | Line 173: | ||
| | | | ||
| 623531 | | 623531 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Gravel is piled up on the site boundary. Appears to have been scraped of the road. | ||
|- | |- | ||
|- | |- | ||
Line 90: | Line 182: | ||
| | | | ||
| 623532 | | 623532 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Gravel and sediment are choking ditch that moves of f to the west toward a stream that flows south. Stream located off western boundary of the site. | ||
|- | |- | ||
|- | |- | ||
Line 97: | Line 191: | ||
| | | | ||
| 625429 | | 625429 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Follow-up from inspection on 10-26-11. Erosion and sedimentation controls not in place on gully to west side of access road, approx 1000' long. | ||
|- | |- | ||
|- | |- | ||
Line 104: | Line 200: | ||
| | | | ||
| 625430 | | 625430 | ||
+ | | 401CLS - Discharge of pollultional material to waters of Commonwealth. | ||
+ | | muddy water coursing down the west side gully to the access road was entering UNT | ||
|- | |- | ||
|- | |- | ||
Line 111: | Line 209: | ||
| | | | ||
| 627329 | | 627329 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Erosion is not being minimized on east side of access road near top of hill. | ||
|- | |- | ||
|- | |- | ||
Line 118: | Line 218: | ||
| | | | ||
| 627330 | | 627330 | ||
+ | | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
+ | | Failure to maintain -- this citation is consistent with the inspection form. Culverts are blocked with sediment. There is a growing erosion feature coming from the edge of the rock apron. | ||
|- | |- | ||
|- | |- | ||
Line 125: | Line 227: | ||
| | | | ||
| 627331 | | 627331 | ||
+ | | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | ||
+ | | Drawing needed for location on east side of access road where water jumped to natural trench. | ||
|- | |- | ||
|- | |- | ||
Line 132: | Line 236: | ||
| | | | ||
| 629792 | | 629792 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(i). Failure to depict topographic features -- natural trench to the east of access road. | ||
|- | |- | ||
|- | |- | ||
Line 139: | Line 245: | ||
| | | | ||
| 629792 | | 629792 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(i). Failure to depict topographic features -- natural trench to the east of access road. | ||
|- | |- | ||
|- | |- | ||
Line 146: | Line 254: | ||
| | | | ||
| 629793 | | 629793 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(v) Failure to describe and depict waters of the Commonwealth -- natural ditch not shown on E&S plan. | ||
|- | |- | ||
|- | |- | ||
Line 153: | Line 263: | ||
| | | | ||
| 629793 | | 629793 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(v) Failure to describe and depict waters of the Commonwealth -- natural ditch not shown on E&S plan. | ||
|- | |- | ||
|- | |- | ||
Line 160: | Line 272: | ||
| | | | ||
| 629794 | | 629794 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(i). Failure to depict topographical features. UNT to West of location not depicted. | ||
|- | |- | ||
|- | |- | ||
Line 167: | Line 281: | ||
| | | | ||
| 629794 | | 629794 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(i). Failure to depict topographical features. UNT to West of location not depicted. | ||
|- | |- | ||
|- | |- | ||
Line 174: | Line 290: | ||
| | | | ||
| 629795 | | 629795 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(v) Failure to describe and depict waters that may receive run-off. UNT to the west of the access road not depicted on E&S plan. | ||
|- | |- | ||
|- | |- | ||
Line 181: | Line 299: | ||
| | | | ||
| 629795 | | 629795 | ||
+ | | 102.4INADPLN - E&S Plan not adequate | ||
+ | | 102.4(b)5(v) Failure to describe and depict waters that may receive run-off. UNT to the west of the access road not depicted on E&S plan. | ||
|- | |- | ||
|- | |- | ||
Line 188: | Line 308: | ||
| | | | ||
| 629796 | | 629796 | ||
+ | | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | ||
+ | | Previous inspection report 11/16/11, 2021872 requested angineered plan modification to address natural trench. Modified plan or notice of modification not received by DEP | ||
|- | |- | ||
|- | |- | ||
Line 195: | Line 317: | ||
| | | | ||
| 629796 | | 629796 | ||
+ | | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | ||
+ | | Previous inspection report 11/16/11, 2021872 requested angineered plan modification to address natural trench. Modified plan or notice of modification not received by DEP | ||
|- | |- | ||
|} | |} | ||
− | + | For data sources see<ref>{{cite web | |
− | { | + | | title = Oil and Gas Historical Inspection Report |
− | + | | publisher = [[Pennsylvania Department of Environmental Protection]] | |
− | + | | date = 2015-05-26 | |
− | + | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections | |
− | + | | accessdate = 2015-05-27 }}</ref> | |
− | + | == References == | |
− | + | {{reflist}} | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | | | ||
− | | | ||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | ==References== | ||
− | {{ | ||
− | |||
__NOEDITSECTION__ | __NOEDITSECTION__ | ||
[[Category:Wells]] | [[Category:Wells]] |
Well ID: 37-081-20421 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.257827,"lon":-76.516008,"icon":""}]} |
County: Lycoming | |
Municipality: Jordan Township | |
Operator Name: XTO ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: SHANER 8507H | |
First Permit Date: 2010-12-01 | |
Last Permit Date: 2010-12-01 | |
Spud Date: | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 16 | |
Latitude: 41.257827 | |
Longitude: -76.516008 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1957465 | 2011-03-08 | No Violations Noted | ||||
1968086 | 2011-04-19 | Violation(s) Noted | 609456 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | ||
1968086 | 2011-04-19 | Violation(s) Noted | 609457 | CSL401CAUSPL - Polluting substance(s) allowed to discharge into Waters of the Commonwealth | Sediment pollution to waters of the Commonwealth | |
1978155 | 2011-05-31 | No Violations Noted | ||||
2015239 | 2011-10-26 | Violation(s) Noted | 623529 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Erosion gully, W side road runs approx 1000'. No rock lining, no E&S apparent. E&S BMPs are not in place to minimize the potential for accelerated erosion. | |
2015239 | 2011-10-26 | Violation(s) Noted | 623530 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Access road, E side, rock-lined ditch. Toward base of road, ditch broken and extends into another erosion feature, perhaps a pre-existing ditch or intermittent stream. Erosion feature is choked with gravel and sediment from the road. E&S BMPs not maint. | |
2015239 | 2011-10-26 | Violation(s) Noted | 623531 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Gravel is piled up on the site boundary. Appears to have been scraped of the road. | |
2015239 | 2011-10-26 | Violation(s) Noted | 623532 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Gravel and sediment are choking ditch that moves of f to the west toward a stream that flows south. Stream located off western boundary of the site. | |
2021877 | 2011-11-16 | Violation(s) & Outstanding Violations | 625429 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Follow-up from inspection on 10-26-11. Erosion and sedimentation controls not in place on gully to west side of access road, approx 1000' long. | |
2021877 | 2011-11-16 | Violation(s) & Outstanding Violations | 625430 | 401CLS - Discharge of pollultional material to waters of Commonwealth. | muddy water coursing down the west side gully to the access road was entering UNT | |
2028173 | 2011-12-06 | Violation(s) & Outstanding Violations | 627329 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Erosion is not being minimized on east side of access road near top of hill. | |
2028173 | 2011-12-06 | Violation(s) & Outstanding Violations | 627330 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Failure to maintain -- this citation is consistent with the inspection form. Culverts are blocked with sediment. There is a growing erosion feature coming from the edge of the rock apron. | |
2028173 | 2011-12-06 | Violation(s) & Outstanding Violations | 627331 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Drawing needed for location on east side of access road where water jumped to natural trench. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629792 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(i). Failure to depict topographic features -- natural trench to the east of access road. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629792 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(i). Failure to depict topographic features -- natural trench to the east of access road. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629793 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(v) Failure to describe and depict waters of the Commonwealth -- natural ditch not shown on E&S plan. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629793 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(v) Failure to describe and depict waters of the Commonwealth -- natural ditch not shown on E&S plan. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629794 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(i). Failure to depict topographical features. UNT to West of location not depicted. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629794 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(i). Failure to depict topographical features. UNT to West of location not depicted. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629795 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(v) Failure to describe and depict waters that may receive run-off. UNT to the west of the access road not depicted on E&S plan. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629795 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)5(v) Failure to describe and depict waters that may receive run-off. UNT to the west of the access road not depicted on E&S plan. | |
2035597 | 2012-01-18 | Violation(s) Noted | 629796 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Previous inspection report 11/16/11, 2021872 requested angineered plan modification to address natural trench. Modified plan or notice of modification not received by DEP | |
2035597 | 2012-01-18 | Violation(s) Noted | 629796 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Previous inspection report 11/16/11, 2021872 requested angineered plan modification to address natural trench. Modified plan or notice of modification not received by DEP |
For data sources see[3]