X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-055-21565"

m
m
Line 1: Line 1:
__TOC__
+
__TOC__
 
== Well Details ==
 
== Well Details ==
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 34-055-21565
 
| Well ID: 34-055-21565
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.37019852, -81.14501382 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="17" | {{#display_map: 41.370144007, -81.14519255 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Geauga County, Ohio|Geauga]]
+
| Country: United States
 
|-
 
|-
| Municipality:  
+
| State: Ohio
 
|-
 
|-
| Operator Name: [[P & S ENERGY INC]]
+
| County: [[Geauga_County,_Ohio|Geauga]]
 +
|-
 +
| Municipality: [[Troy_Township,_Geauga_County,_Ohio|Troy Township]]
 +
|-
 +
| Operator Name: [[PIN OAK ENERGY PARTNERS LLC]]
 
|-
 
|-
 
| Well Pad ID:  
 
| Well Pad ID:  
 
|-
 
|-
| Farm/Lease Name:  
+
| Farm/Lease Name: CLIFFORD UNIT
 
|-
 
|-
| First Permit Date:  
+
| License Status: Producing
 
|-
 
|-
| Last Permit Date:  
+
| License Date: 1988-07-29
 
|-
 
|-
 
| Spud Date: 1988-09-14
 
| Spud Date: 1988-09-14
 
|-
 
|-
| Unconventional: No
+
| Spud Drilling Contractor: [[CUBBY DRLG]]
 +
|-
 +
| Final Drill Date: 1988-09-21
 +
|-
 +
| Well Total Depth: 4195 ft
 
|-
 
|-
 
| Configuration: Vertical
 
| Configuration: Vertical
 
|-
 
|-
| Well Status: Producing
+
| Latitude: 41.370144007
 +
|-
 +
| Longitude: -81.14519255
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well, tblLocational, tblPlugWell, tblInspection, tblCivilTownships and tblPad Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Well History ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Well Status
 +
!scope="col" style="width: 15%;text-align: center"| Well Status Date
 +
!scope="col" style="text-align: center"| Comment
 +
|-
 +
| CO
 +
| 1988-07-29
 +
| 2816  P & S ENERGY INC  GeoDate  7/29/88
 +
|-
 +
| Oil and Gas
 +
| 1988-07-29
 +
| Issued Date 7/29/88 Expired Date 7/29/89 Acres 0080000 Tool Type RTAF Proposed Formation CL/ROSE RUN Proposed Depth 04195 Proposed Drill Depth 04195
 +
|-
 +
| Original Spud
 +
| 1988-09-14
 +
 +
|-
 +
| Completed
 +
| 1988-09-21
 +
 +
|-
 +
| Reached Total Depth
 +
| 1988-09-21
 +
 +
|-
 +
| Completion Report Received
 +
| 1988-09-29
 +
 +
|-
 +
| Construction Permit Expires
 +
| 1989-07-29
 +
 +
|-
 +
| Change of Owner
 +
| 2019-02-26
 +
| Operator changed from 2816, P & S ENERGY INC to 9722, PIN OAK ENERGY PARTNERS LLC
 
|-
 
|-
| Violations: 0
+
| Record Last Modified
 +
| 2019-02-26
 +
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Well and WellHistry Tables
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Perforation Treatments ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Perforation Date
 +
!scope="col" style="text-align: center"| Interval Top (ft)
 +
!scope="col" style="text-align: center"| Interval Base (ft)
 +
!scope="col" style="text-align: center"| Number of Shots
 
|-
 
|-
| Latitude: 41.37019852
+
| 1997-06-29
 +
| style="text-align: right;" | 4002
 +
| style="text-align: right;" | 4110
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Longitude: -81.14501382
+
| 2006-09-11
 +
| style="text-align: right;" | 4004
 +
| style="text-align: right;" | 4106
 +
| style="text-align: right;" | 23
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - Perfs Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Job Start Date
 +
!scope="col" style="text-align: center"| Job End Date
 +
!scope="col" style="text-align: center"| True Vertical Depth (ft)
 +
!scope="col" style="text-align: center"| Total Water Volume (gal)
 +
!scope="col" style="text-align: center"| Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" style="width: 100%"
 +
!scope="col" style="text-align: center"| Job Number
 +
!scope="col" style="text-align: center"| Trade Name
 +
!scope="col" style="text-align: center"| Supplier
 +
!scope="col" style="text-align: center"| Purpose
 +
!scope="col" style="text-align: center"| Ingredient Name
 +
!scope="col" style="white-space: nowrap;text-align: center"| CAS Number
 +
!scope="col" style="text-align: center"| Additive Percentage by Mass
 +
!scope="col" style="text-align: center"| Job Percentage by Mass
 +
!scope="col" style="text-align: center"| Mass Used (lb)
 +
|-
 +
|}-->
 +
== Stimulations Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" style="text-align: center"| Stimulation Date
!scope="col" | GAS QUANTITY
+
!scope="col" style="text-align: center"| Chemical Agent
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Chemical Agent Concentration (%)
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" style="text-align: center"| Fracking Fluid Volume
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Mass of Proppant Used (lb)
!scope="col" | OIL QUANTITY
+
!scope="col" style="text-align: center"| Fracking Company
!scope="col" | OIL PRODUCTION DAYS
+
!scope="col" style="text-align: center"| Comments
 
|-
 
|-
| 1989-0
 
| style="text-align:right;" | 16367.0
 
 
|  
 
|  
 +
| H2O
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 72020 Gal
 +
| style="text-align: right;" | 50000
 
|  
 
|  
 +
| FRAC:WATER/SAND/N2
 +
|-
 
|  
 
|  
| style="text-align:right;" | 2453.0
+
| N2
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 230 Mscf
 +
| style="text-align: right;" | 0
 
|  
 
|  
 +
| 49.2 BPM @ 2496#.
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Risk Based Data Management System - tblStimulation Table
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date =  2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Gas Quantity (mcf)
 +
!scope="col" style="text-align: center"| Oil Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 +
|-
 +
| 1989
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 16367
 +
| style="text-align: right;" | 2453
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1990
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 8299
 +
| style="text-align: right;" | 895
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1991
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 7447
 +
| style="text-align: right;" | 762
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1992
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 9031
 +
| style="text-align: right;" | 312
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1993
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3458
 +
| style="text-align: right;" | 381
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1994
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3281
 +
| style="text-align: right;" | 309
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1995
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3157
 +
| style="text-align: right;" | 310
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1996
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3467
 +
| style="text-align: right;" | 516
 +
| style="text-align: right;" | 365
 +
|-
 +
| 1997
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 4083
 +
| style="text-align: right;" | 422
 +
| style="text-align: right;" | 354
 +
|-
 +
| 1998
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3589
 +
| style="text-align: right;" | 507
 +
| style="text-align: right;" | 365
 
|-
 
|-
 +
| 1999
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 4430
 +
| style="text-align: right;" | 362
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1990-0
+
| 2000
| style="text-align:right;" | 8299.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 4027
|  
+
| style="text-align: right;" | 276
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 895.0
+
|-
|  
+
| 2001
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3323
 +
| style="text-align: right;" | 235
 +
| style="text-align: right;" | 365
 
|-
 
|-
 +
| 2002
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2814
 +
| style="text-align: right;" | 273
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1991-0
+
| 2003
| style="text-align:right;" | 7447.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 3235
|
+
| style="text-align: right;" | 176
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 762.0
 
|
 
 
|-
 
|-
 +
| 2004
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2308
 +
| style="text-align: right;" | 316
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1992-0
+
| 2005
| style="text-align:right;" | 9031.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2254
|
+
| style="text-align: right;" | 222
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 312.0
 
|
 
 
|-
 
|-
 +
| 2006
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2745
 +
| style="text-align: right;" | 173
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1993-0
+
| 2007
| style="text-align:right;" | 3458.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2730
|
+
| style="text-align: right;" | 233
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 381.0
 
|
 
 
|-
 
|-
 +
| 2008
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2844
 +
| style="text-align: right;" | 206
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1994-0
+
| 2009
| style="text-align:right;" | 3281.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2588
|
+
| style="text-align: right;" | 236
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 309.0
 
|
 
 
|-
 
|-
 +
| 2010
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 3026
 +
| style="text-align: right;" | 191
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1995-0
+
| 2011
| style="text-align:right;" | 3157.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2390
|
+
| style="text-align: right;" | 270
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 310.0
 
|
 
 
|-
 
|-
 +
| 2012
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2702
 +
| style="text-align: right;" | 226
 +
| style="text-align: right;" | 366
 
|-
 
|-
| 1996-0
+
| 2013
| style="text-align:right;" | 3467.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2581
|
+
| style="text-align: right;" | 232
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 516.0
 
|
 
 
|-
 
|-
 +
| 2014
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 2268
 +
| style="text-align: right;" | 207
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1997-0
+
| 2015
| style="text-align:right;" | 4083.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 2386
|
+
| style="text-align: right;" | 199
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 422.0
 
|
 
 
|-
 
|-
 +
| 2016
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 1920
 +
| style="text-align: right;" | 175
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1998-0
+
| 2017
| style="text-align:right;" | 3589.0
+
| [[P & S ENERGY INC]]
|  
+
| style="text-align: right;" | 1915
|
+
| style="text-align: right;" | 156
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 507.0
 
|
 
 
|-
 
|-
 +
| 2018
 +
| [[P & S ENERGY INC]]
 +
| style="text-align: right;" | 1640
 +
| style="text-align: right;" | 175
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 1999-0
+
|}
| style="text-align:right;" | 4430.0
+
For data sources see<ref>{{cite web
|  
+
| title = Risk Based Data Management System - Production Table - Oil and Gas Data
|  
+
|publisher = [[Ohio Department of Natural Resources]]
|  
+
| date =  2019-05-07
| style="text-align:right;" | 362.0
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
|
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Oil and Gas Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
| date = 2019-05-07
 +
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 +
{| class="wikitable sortable"
 +
!scope="col" style="text-align: center"| Period
 +
!scope="col" style="text-align: center"| Operator Name
 +
!scope="col" style="text-align: center"| Waste Type
 +
!scope="col" style="text-align: center"| Quantity (bbl)
 +
!scope="col" style="text-align: center"| Production Days
 
|-
 
|-
 +
| 1989
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 821
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2000-0
+
| 1990
| style="text-align:right;" | 4027.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 283
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 276.0
 
|
 
 
|-
 
|-
 +
| 1991
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 200
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2001-0
+
| 1992
| style="text-align:right;" | 3323.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 100
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 235.0
 
|
 
 
|-
 
|-
 +
| 1993
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 65
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2002-0
+
| 1994
| style="text-align:right;" | 2814.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 60
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 273.0
 
|
 
 
|-
 
|-
 +
| 1995
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 80
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2003-0
+
| 1996
| style="text-align:right;" | 3235.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 215
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 176.0
 
|
 
 
|-
 
|-
 +
| 1997
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 240
 +
| style="text-align: right;" | 354
 
|-
 
|-
| 2004-0
+
| 1998
| style="text-align:right;" | 2308.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 156
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 316.0
 
|
 
 
|-
 
|-
 +
| 1999
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 150
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2005-0
+
| 2000
| style="text-align:right;" | 2254.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 70
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 222.0
 
|
 
 
|-
 
|-
 +
| 2001
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 65
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2006-0
+
| 2002
| style="text-align:right;" | 2745.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 150
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 173.0
 
|
 
 
|-
 
|-
 +
| 2003
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 73
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2007-0
+
| 2004
| style="text-align:right;" | 2730.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 156
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 233.0
 
|
 
 
|-
 
|-
 +
| 2005
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 64
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2008-0
+
| 2006
| style="text-align:right;" | 2844.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 156
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 206.0
 
|
 
 
|-
 
|-
 +
| 2007
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 82
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2009-0
+
| 2008
| style="text-align:right;" | 2588.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 123
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 236.0
 
|
 
 
|-
 
|-
 +
| 2009
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 70
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2010-0
+
| 2010
| style="text-align:right;" | 3026.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 164
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 191.0
 
|
 
 
|-
 
|-
 +
| 2011
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 84
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2011-0
+
| 2012
| style="text-align:right;" | 2390.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 217
|
+
| style="text-align: right;" | 366
| style="text-align:right;" | 270.0
 
|
 
 
|-
 
|-
 +
| 2013
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 89
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2012-0
+
| 2014
| style="text-align:right;" | 2702.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 0
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 226.0
 
|
 
 
|-
 
|-
 +
| 2015
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 165
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2013-0
+
| 2016
| style="text-align:right;" | 2581.0
+
| [[P & S ENERGY INC]]
|
+
| Brine
|
+
| style="text-align: right;" | 236
|
+
| style="text-align: right;" | 365
| style="text-align:right;" | 232.0
 
|
 
 
|-
 
|-
 +
| 2017
 +
| [[P & S ENERGY INC]]
 +
| Brine
 +
| style="text-align: right;" | 236
 +
| style="text-align: right;" | 365
 
|-
 
|-
| 2014-0
+
| 2018
| style="text-align:right;" | 2268.0
+
| [[P & S ENERGY INC]]
| style="text-align:right;" | 365.0
+
| Brine
|  
+
| style="text-align: right;" | 80
|  
+
| style="text-align: right;" | 365
| style="text-align:right;" | 207.0
 
| style="text-align:right;" | 365.0
 
 
|-
 
|-
 
|}
 
|}
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - Production Table - Brine Data
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
|publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date =  2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Production
+
| url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
| accessdate = 2019-05-21 }}</ref>
 +
<ref>{{cite web
 +
| title = Combined Production - Brine Data
 +
|publisher = [[Ohio Department of Natural Resources]]
 +
  | date = 2019-05-07
 +
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
 +
  | accessdate = 2019-05-21 }}</ref>
 
== Inspection Data ==
 
== Inspection Data ==
 +
==== Inspections Performed ====
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | INSPECTION ID
+
!scope="col" style="text-align: center"| Inspection ID
!scope="col" | DATE
+
!scope="col" style="text-align: center"| Inspection Date
!scope="col" | DESCRIPTION
+
!scope="col" style="text-align: center"| Inspection Type
!scope="col" | COMMENT
+
!scope="col" style="text-align: center"| Inspection Result
!scope="col" | VIOLATION ID
+
!scope="col" style="text-align: center"| Inspection Comments
!scope="col" | VIOLATION CODE
+
|-
!scope="col" | VIOLATION COMMENT
+
| 0910359334
 +
| 2018-01-25
 +
| Production Wells
 +
| No Violations
 +
| At the time of this inspection, the well was equipped with a pumpjack and the annulus and flow line valves on the well were open.  Production for this well was current.  The tank battery consisted of one 140 BBL production tank, one 100 BBL brine tank, and a heater treater separator,  Valves on the separator were open and the chart showed production.  There was a domestic line plumbed off of the separator with a meter, drip bottle and regulator.  Valves on the domestic line were open.  The tank battery was diked and had legible signage.  The lease access was stable.  No violations observed.
 
|-
 
|-
 
| 1347368311
 
| 1347368311
 
| 2012-09-10
 
| 2012-09-10
|  
+
| Production Wells
 +
| No Violations
 
| I observed the unit to consist of a tank battery (TB) and wellhead located west of RT. 700, and accessed via an ungated, lease road directly from the main road.  The TB is located approximately 75 feet from the main road, and consists of one  210 barrel (BBL) production tank, one 110 BBL brine tank, and a mechanical seperator unit. The dike construction appears to be adequate. I observed the spacing between the the production tank and the brine tank to be less than 2 feet. Otheriwse, the spacing of the tanks and mechanicals within the unit looks good.  There is some vegetation growth in the dike ballast area. I observed some oil staining around the tank loadout fittings, but did not observe any active leaking or detectable gas vapors. The TB is not fenced or enclosed. Identification at the TB is present and in good condition.  The tanks are not fitted with spark arrestors, low-presssure-relief valves, or carbon filters. The unit appears to be actively producing. The mechanicals appear to be in a reasonable state of repair and maintenance. The wellhead is located approximately 200 feet to the southwest. The wellhead is fitted with a pumpjack system which was in operation. The wellhead is not fenced or enclosed. There is no identification at the wellhead. There was some oil staining around the wellhaed casing and some of the valving, but did not appear to be actively leaking. There were no gas vapors deteted on the handheld gas meter (Honeywell PHD6).
 
| I observed the unit to consist of a tank battery (TB) and wellhead located west of RT. 700, and accessed via an ungated, lease road directly from the main road.  The TB is located approximately 75 feet from the main road, and consists of one  210 barrel (BBL) production tank, one 110 BBL brine tank, and a mechanical seperator unit. The dike construction appears to be adequate. I observed the spacing between the the production tank and the brine tank to be less than 2 feet. Otheriwse, the spacing of the tanks and mechanicals within the unit looks good.  There is some vegetation growth in the dike ballast area. I observed some oil staining around the tank loadout fittings, but did not observe any active leaking or detectable gas vapors. The TB is not fenced or enclosed. Identification at the TB is present and in good condition.  The tanks are not fitted with spark arrestors, low-presssure-relief valves, or carbon filters. The unit appears to be actively producing. The mechanicals appear to be in a reasonable state of repair and maintenance. The wellhead is located approximately 200 feet to the southwest. The wellhead is fitted with a pumpjack system which was in operation. The wellhead is not fenced or enclosed. There is no identification at the wellhead. There was some oil staining around the wellhaed casing and some of the valving, but did not appear to be actively leaking. There were no gas vapors deteted on the handheld gas meter (Honeywell PHD6).
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1486393156
 
| 1486393156
 
| 2012-09-10
 
| 2012-09-10
|  
+
| Production Wells
 +
| No Violations
 
| The unit is comprised of a two-tank battery (TB) (1, 210-barrel production and 1, 100-bbl brine) and a wellhead with pump jack. The well is currently in production. The wellhead is located 200 feet west of the TB. Well and tank spacing look good. Unit identification is present and legible at the tank battery.  The tank battery dike is in good condition.  I did not observe any leaks, spills, or other signs of contamination. No violations noted.
 
| The unit is comprised of a two-tank battery (TB) (1, 210-barrel production and 1, 100-bbl brine) and a wellhead with pump jack. The well is currently in production. The wellhead is located 200 feet west of the TB. Well and tank spacing look good. Unit identification is present and legible at the tank battery.  The tank battery dike is in good condition.  I did not observe any leaks, spills, or other signs of contamination. No violations noted.
|
 
|
 
|
 
|-
 
 
|-
 
|-
 
| 1525954263
 
| 1525954263
 
| 2013-05-20
 
| 2013-05-20
|  
+
| Production Wells
 +
| No Violations
 
| My inspection found the well to be equipped with a pump jack. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
 
| My inspection found the well to be equipped with a pump jack. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
|
 
|
 
|
 
 
|-
 
|-
 
|}
 
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" style="text-align: center"| Inspection ID
 +
!scope="col" style="text-align: center"| Violation ID
 +
!scope="col" style="text-align: center"| Violation Date
 +
!scope="col" style="text-align: center"| Violation Code
 +
!scope="col" style="text-align: center"| Violation Comments
 +
|-
 +
|}-->
 
For data sources see<ref>{{cite web
 
For data sources see<ref>{{cite web
  | title = Ohio Department of Natural Resources RBDMS
+
  | title = Risk Based Data Management System - tblInspection, tblInspFail and tblinspFlDesc Tables
  | publisher = [http://oilandgas.ohiodnr.gov/]
+
  |publisher = [[Ohio Department of Natural Resources]]
  | date = 2015-06-19
+
  | date = 2019-05-07
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources#Inspection
+
  | url = http://wellwiki.org/wiki/Ohio_Oil_and_Gas_Data_Sources
  | accessdate = 2015-06-20 }}</ref>
+
  | accessdate = 2019-05-21 }}</ref>
== References ==
+
==References==
{{reflist}}
+
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Ohio Wells]]

Revision as of 07:49, 25 July 2019

Well Details

Well ID: 34-055-21565
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Troy Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: CLIFFORD UNIT
License Status: Producing
License Date: 1988-07-29
Spud Date: 1988-09-14
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1988-09-21
Well Total Depth: 4195 ft
Configuration: Vertical
Latitude: 41.370144007
Longitude: -81.14519255

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1988-07-29 2816 P & S ENERGY INC GeoDate 7/29/88
Oil and Gas 1988-07-29 Issued Date 7/29/88 Expired Date 7/29/89 Acres 0080000 Tool Type RTAF Proposed Formation CL/ROSE RUN Proposed Depth 04195 Proposed Drill Depth 04195
Original Spud 1988-09-14
Completed 1988-09-21
Reached Total Depth 1988-09-21
Completion Report Received 1988-09-29
Construction Permit Expires 1989-07-29
Change of Owner 2019-02-26 Operator changed from 2816, P & S ENERGY INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2019-02-26

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4002 4110 0
2006-09-11 4004 4106 23

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72020 Gal 50000 FRAC:WATER/SAND/N2
N2 0 230 Mscf 0 49.2 BPM @ 2496#.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 P & S ENERGY INC 16367 2453 365
1990 P & S ENERGY INC 8299 895 365
1991 P & S ENERGY INC 7447 762 365
1992 P & S ENERGY INC 9031 312 365
1993 P & S ENERGY INC 3458 381 365
1994 P & S ENERGY INC 3281 309 365
1995 P & S ENERGY INC 3157 310 365
1996 P & S ENERGY INC 3467 516 365
1997 P & S ENERGY INC 4083 422 354
1998 P & S ENERGY INC 3589 507 365
1999 P & S ENERGY INC 4430 362 365
2000 P & S ENERGY INC 4027 276 365
2001 P & S ENERGY INC 3323 235 365
2002 P & S ENERGY INC 2814 273 365
2003 P & S ENERGY INC 3235 176 365
2004 P & S ENERGY INC 2308 316 365
2005 P & S ENERGY INC 2254 222 365
2006 P & S ENERGY INC 2745 173 365
2007 P & S ENERGY INC 2730 233 365
2008 P & S ENERGY INC 2844 206 365
2009 P & S ENERGY INC 2588 236 365
2010 P & S ENERGY INC 3026 191 365
2011 P & S ENERGY INC 2390 270 365
2012 P & S ENERGY INC 2702 226 366
2013 P & S ENERGY INC 2581 232 365
2014 P & S ENERGY INC 2268 207 365
2015 P & S ENERGY INC 2386 199 365
2016 P & S ENERGY INC 1920 175 365
2017 P & S ENERGY INC 1915 156 365
2018 P & S ENERGY INC 1640 175 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 P & S ENERGY INC Brine 821 365
1990 P & S ENERGY INC Brine 283 365
1991 P & S ENERGY INC Brine 200 365
1992 P & S ENERGY INC Brine 100 365
1993 P & S ENERGY INC Brine 65 365
1994 P & S ENERGY INC Brine 60 365
1995 P & S ENERGY INC Brine 80 365
1996 P & S ENERGY INC Brine 215 365
1997 P & S ENERGY INC Brine 240 354
1998 P & S ENERGY INC Brine 156 365
1999 P & S ENERGY INC Brine 150 365
2000 P & S ENERGY INC Brine 70 365
2001 P & S ENERGY INC Brine 65 365
2002 P & S ENERGY INC Brine 150 365
2003 P & S ENERGY INC Brine 73 365
2004 P & S ENERGY INC Brine 156 365
2005 P & S ENERGY INC Brine 64 365
2006 P & S ENERGY INC Brine 156 365
2007 P & S ENERGY INC Brine 82 365
2008 P & S ENERGY INC Brine 123 365
2009 P & S ENERGY INC Brine 70 365
2010 P & S ENERGY INC Brine 164 365
2011 P & S ENERGY INC Brine 84 365
2012 P & S ENERGY INC Brine 217 366
2013 P & S ENERGY INC Brine 89 365
2014 P & S ENERGY INC Brine 0 365
2015 P & S ENERGY INC Brine 165 365
2016 P & S ENERGY INC Brine 236 365
2017 P & S ENERGY INC Brine 236 365
2018 P & S ENERGY INC Brine 80 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0910359334 2018-01-25 Production Wells No Violations At the time of this inspection, the well was equipped with a pumpjack and the annulus and flow line valves on the well were open. Production for this well was current. The tank battery consisted of one 140 BBL production tank, one 100 BBL brine tank, and a heater treater separator, Valves on the separator were open and the chart showed production. There was a domestic line plumbed off of the separator with a meter, drip bottle and regulator. Valves on the domestic line were open. The tank battery was diked and had legible signage. The lease access was stable. No violations observed.
1347368311 2012-09-10 Production Wells No Violations I observed the unit to consist of a tank battery (TB) and wellhead located west of RT. 700, and accessed via an ungated, lease road directly from the main road. The TB is located approximately 75 feet from the main road, and consists of one 210 barrel (BBL) production tank, one 110 BBL brine tank, and a mechanical seperator unit. The dike construction appears to be adequate. I observed the spacing between the the production tank and the brine tank to be less than 2 feet. Otheriwse, the spacing of the tanks and mechanicals within the unit looks good. There is some vegetation growth in the dike ballast area. I observed some oil staining around the tank loadout fittings, but did not observe any active leaking or detectable gas vapors. The TB is not fenced or enclosed. Identification at the TB is present and in good condition. The tanks are not fitted with spark arrestors, low-presssure-relief valves, or carbon filters. The unit appears to be actively producing. The mechanicals appear to be in a reasonable state of repair and maintenance. The wellhead is located approximately 200 feet to the southwest. The wellhead is fitted with a pumpjack system which was in operation. The wellhead is not fenced or enclosed. There is no identification at the wellhead. There was some oil staining around the wellhaed casing and some of the valving, but did not appear to be actively leaking. There were no gas vapors deteted on the handheld gas meter (Honeywell PHD6).
1486393156 2012-09-10 Production Wells No Violations The unit is comprised of a two-tank battery (TB) (1, 210-barrel production and 1, 100-bbl brine) and a wellhead with pump jack. The well is currently in production. The wellhead is located 200 feet west of the TB. Well and tank spacing look good. Unit identification is present and legible at the tank battery. The tank battery dike is in good condition. I did not observe any leaks, spills, or other signs of contamination. No violations noted.
1525954263 2013-05-20 Production Wells No Violations My inspection found the well to be equipped with a pump jack. The annulus valve is closed. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.

For data sources see[9]