X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-24925"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-24925
 
| Well ID: 37-125-24925
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.051541, -80.319113 | width=100% | height=100% }}  
+
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.051542, -80.319114 | width=100% | height=100% }}
 
|-
 
|-
| County: [[Washington County, Pennsylvania|Washington]]
+
| Country: United States
 
|-
 
|-
| Municipality: [[Morris Township, Washington County, Pennsylvania|Morris Township]]
+
| State: Pennsylvania
 
|-
 
|-
| Operator Name: [[CNX GAS CO LLC]]
+
| County: [[Washington_County,_Pennsylvania|Washington]]
 
|-
 
|-
| Well Pad ID: [[145656|145656]]
+
| Municipality: [[Morris Township,_Washington_County,_Pennsylvania|Morris Township]]
 +
|-
 +
| Operator Name: [[HG ENERGY II APPALACHIA LLC]]
 +
|-
 +
| Well Pad ID: [[145656]]
 
|-
 
|-
 
| Farm/Lease Name: COFFIELD/GOTTSCHALK NV34CHS
 
| Farm/Lease Name: COFFIELD/GOTTSCHALK NV34CHS
 
|-
 
|-
| First Permit Date: 2012-12-17
+
| License Status: Active
 
|-
 
|-
| Last Permit Date: 2013-02-06
+
| Spud Date: 06/19/2013
 +
|-
 +
| Permit Date: 12/17/2012
 +
|-
 +
| Unconventional Well: Y
 +
|-
 +
| Configuration: Horizontal Well
 +
|-
 +
| Latitude: 40.051542
 +
|-
 +
| Longitude: -80.319114
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title = Permits Issued Detail Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref><ref>{{cite web
 +
| title = Spud Data Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-04-30
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-16 }}</ref><ref>{{cite web
 +
| title = Oil and Gas Well Pad Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Production Data ==
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Period
 +
!scope="col" | Operator Name
 +
!scope="col" | Gas Quantity (mcf)
 +
!scope="col" | Gas Production Days
 +
!scope="col" | Oil Quantity (bbl)
 +
!scope="col" | Oil Production Days
 +
!scope="col" | Water Quantity (bbl)
 +
!scope="col" | Water Production Days
 
|-
 
|-
| Spud Date: 2013-06-19
+
| 2013
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Unconventional: Yes
+
| 2014
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Horizontal: Yes
+
| 2015
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 1,368,507.53
 +
| style="text-align: right;" | 327
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Well Status: ACTIVE
+
| 2016
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 1,096,493.65
 +
| style="text-align: right;" | 364
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Violations: 0
+
| 2017
 +
| [[CNX GAS CO LLC]]
 +
| style="text-align: right;" | 900,645.04
 +
| style="text-align: right;" | 363
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Latitude: 40.051541
+
| 2018
 +
| [[HG ENERGY II APPALACHIA LLC]]
 +
| style="text-align: right;" | 854,691.00
 +
| style="text-align: right;" | 365
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
| Longitude: -80.319113
+
| 2019
 +
| [[HG ENERGY II APPALACHIA LLC]]
 +
| style="text-align: right;" | 98,320.00
 +
| style="text-align: right;" | 59
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 +
| style="text-align: right;" | 0.00
 +
| style="text-align: right;" | 0
 
|-
 
|-
 
|}
 
|}
== Production Data ==
+
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Production Reports
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-03-31
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
!scope="col" | PERIOD
+
!scope="col" | Period
!scope="col" | GAS QUANTITY
+
!scope="col" | Waste Type
!scope="col" | GAS PRODUCTION DAYS
+
!scope="col" | Quantity
!scope="col" | CONDENSATE QUANTITY
+
!scope="col" | Disposal Method
!scope="col" | CONDENSATE PRODUCTION DAYS
+
!scope="col" | Waste Facility ID
!scope="col" | OIL QUANTITY
+
|-
!scope="col" | OIL PRODUCTION DAYS
+
| 15AUGU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,194.97 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15DECU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 1,822.80 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15JULU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,272.09 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15NOVU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2,225.49 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 15OCTU
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2,389.36 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-1
+
| 15SEPU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels)
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 2,505.74 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16APRU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,455.05 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16AUGU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,167.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2013-2
+
| 16DECU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 381.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|
| style="text-align:right;" | 0.0
+
|-
| style="text-align:right;" | 0.0
+
| 16FEBU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,451.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16JANU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,749.81 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16JULU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 936.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16JUNU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 62.06 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 16JUNU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 24.60 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 16JUNU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 214.05 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 16JUNU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 885.80 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16MARU
 +
| Fracturing Fluid Waste (in Barrels) RWC 805
 +
| style="text-align: right;" | 10.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16MARU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,431.36 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 +
|-
 +
| 16MAYU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.27 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 16MAYU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 11.20 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 
|-
 
|-
 +
| 16MAYU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.17 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2014-1
+
| 16MAYU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 1,076.60 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16NOVU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 125.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2014-2
+
| 16NOVU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 12.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-119-28780
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16NOVU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 134.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2015-02
+
| 16NOVU
| style="text-align:right;" | 172337.41
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 21.0
+
| style="text-align: right;" | 523.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 275.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 
|-
 
|-
| 2015-01
+
| 16OCTU
| style="text-align:right;" | 0.0
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 0.0
+
| style="text-align: right;" | 21.00 Bbl
| style="text-align:right;" | 0.0
+
| INJECTION DISPOSAL WELL
| style="text-align:right;" | 0.0
+
| 34-119-28780
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
 +
| 16OCTU
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 312.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2015-03
+
| 16OCTU
| style="text-align:right;" | 124034.9
+
| Produced Fluid (in Barrels) RWC 802
| style="text-align:right;" | 31.0
+
| style="text-align: right;" | 272.00 Bbl
| style="text-align:right;" | 0.0
+
| REUSE OTHER THAN ROAD SPREADING
| style="text-align:right;" | 0.0
+
|  
| style="text-align:right;" | 0.0
 
| style="text-align:right;" | 0.0
 
 
|-
 
|-
|}
+
| 16SEPU
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Production Report
+
| style="text-align: right;" | 1,155.00 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| REUSE OTHER THAN ROAD SPREADING
| date = 2015-05-26
+
|  
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Production
 
| accessdate = 2015-05-27 }}</ref>
 
== Waste Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | PERIOD
 
!scope="col" | TYPE
 
!scope="col" | QUANTITY
 
!scope="col" | UNITS
 
!scope="col" | DISPOSAL METHOD
 
!scope="col" | WASTE FACILITY PERMIT ID
 
!scope="col" | WASTE FACILITY NAME
 
!scope="col" | FACILITY CITY
 
!scope="col" | FACILITY STATE
 
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 194.82
+
| style="text-align: right;" | 194.82 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| PAD059087072
 
| PAD059087072
| MAX ENVIRONMENTAL TECHNOLOGIES INC BULGER FACILITY
 
| BULGER
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 210.33
+
| style="text-align: right;" | 210.33 Tons
| Tons
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
| PAD004835146
+
| 301071
| MAX ENVIRONMENTAL TECHNOLOGIES INC YUKON FACILITY
 
| YUKON
 
| PA
 
|-
 
 
|-
 
|-
 
| 2013-2
 
| 2013-2
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 92.0
+
| style="text-align: right;" | 92.00 Bbl
| Bbl
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
| PAD004835146
+
| 301071
| MAX ENVIRONMENTAL TECHNOLOGIES INC YUKON FACILITY
 
| YUKON
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 45.7
+
| style="text-align: right;" | 45.70 Tons
| Tons
 
 
| LANDFILL
 
| LANDFILL
 
| PAD059087072
 
| PAD059087072
| MAX ENVIRONMENTAL TECHNOLOGIES INC BULGER FACILITY
 
| BULGER
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILL CUTTINGS
+
| Drill Cuttings (in Tons)
| style="text-align:right;" | 465.34
+
| style="text-align: right;" | 465.34 Tons
| Tons
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
| PAD004835146
+
| 301071
| MAX ENVIRONMENTAL TECHNOLOGIES INC YUKON FACILITY
 
| YUKON
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-1
 
| 2014-1
| DRILLING FLUID WASTE
+
| Drilling Fluid Waste (in Barrels)
| style="text-align:right;" | 0.25
+
| style="text-align: right;" | 0.25 Bbl
| Bbl
 
 
| RESIDUAL WASTE TRANSFER FACILITY
 
| RESIDUAL WASTE TRANSFER FACILITY
| PAD004835146
+
| 301071
| MAX ENVIRONMENTAL TECHNOLOGIES INC YUKON FACILITY
 
| YUKON
 
| PA
 
|-
 
 
|-
 
|-
 
| 2014-2
 
| 2014-2
| FRACING FLUID WASTE
+
| Fracing Fluid Waste (in Barrels)
| style="text-align:right;" | 3.0
+
| style="text-align: right;" | 3,134.18 Bbl
| Bbl
 
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
| REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY
+
|-
 +
| 2015-07
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,272.09 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-08
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 3,194.97 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
|}
+
| 2015-09
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels)
| title = Oil and Gas Historical Waste Report
+
| style="text-align: right;" | 2,505.74 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| REUSE OTHER THAN ROAD SPREADING
| date = 2015-05-26
+
|  
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Waste
 
| accessdate = 2015-05-26 }}</ref>
 
== Inspection Data ==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | INSPECTION ID
 
!scope="col" | DATE
 
!scope="col" | DESCRIPTION
 
!scope="col" | COMMENT
 
!scope="col" | VIOLATION ID
 
!scope="col" | VIOLATION CODE
 
!scope="col" | VIOLATION_COMMENT
 
 
|-
 
|-
| 2168339
+
| 2015-1
| 2013-05-20
+
| Fracing Fluid Waste (in Barrels)
| No Violations Noted
+
| style="text-align: right;" | 587.95 Bbl
| Pre-operational inspection.  No violations but rocking and stabilizing work needs to be done.
+
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-1
 +
| Fracturing Fluid Waste (in Tons)
 +
| style="text-align: right;" | 12.69 Tons
 +
| LANDFILL
 +
| 100172
 +
|-
 +
| 2015-1
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 13,256.19 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2015-10
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2,389.36 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2015-11
 +
| Produced Fluid (in Barrels)
 +
| style="text-align: right;" | 2,225.49 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2182087
+
| 2015-12
| 2013-06-26
+
| Produced Fluid (in Barrels)
| No Violations Noted
+
| style="text-align: right;" | 1,822.80 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,749.81 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,451.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-03
 +
| Fracturing Fluid Waste (in Barrels) RWC 805
 +
| style="text-align: right;" | 10.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,431.36 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 +
|
 
|-
 
|-
| 2199958
+
| 2016-04
| 2013-08-07
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 1,455.05 Bbl
| On August 7, 2013, I conducted a follow-up inspection of CONSOL's NV-34 site; I met primarily with Dave Fedrick of CONSOL.
+
| REUSE OTHER THAN ROAD SPREADING
 
 
For the most part the site's vegetation is doing well.  There seems to be a lot of dead vegetation on the upper slope of the access road but Dave will work with the contractor to establish growth there also.
 
 
 
Any run-off would be contained within the LOD.
 
 
 
|  
 
 
|  
 
|  
 +
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.27 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 11.20 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 32.17 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2016-05
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,076.60 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 62.06 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 24.60 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 2016-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 214.05 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2204362
+
| 2016-06
| 2013-09-11
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 885.80 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 936.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,167.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 1,155.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 275.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 21.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 2016-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 312.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 2222555
+
| 2016-10
| 2013-10-30
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 272.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 125.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-013-20609
 +
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 12.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28780
 +
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 134.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2016-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 523.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2016-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 381.00 Bbl
 +
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 +
|-
 +
| 2017-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 423.84 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2017-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 369.61 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2231182
+
| 2017-05
| 2013-12-09
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 289.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2017-06
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 439.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2017-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 352.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2017-08
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 691.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2017-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 562.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2017-10
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 565.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2017-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 565.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
 +
| 2017-12
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 742.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 2343194
+
| 2018-01
| 2015-02-08
+
| Produced Fluid (in Barrels) RWC 802
| No Violations Noted
+
| style="text-align: right;" | 362.00 Bbl
| CNX bringing entire pad online to production. Currently flaring large volume of gas to bring up pressure from well to producing pressure. NOVIO
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-02
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 351.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 +
|-
 +
| 2018-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 320.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 +
|-
 +
| 2018-04
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 256.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 
|  
 
|  
 
|-
 
|-
|}
+
| 2018-05
For data sources see<ref>{{cite web
+
| Produced Fluid (in Barrels) RWC 802
| title = Oil and Gas Historical Inspection Report
+
| style="text-align: right;" | 219.00 Bbl
| publisher = [[Pennsylvania Department of Environmental Protection]]
+
| INJECTION DISPOSAL WELL
| date = 2015-05-26
+
| 34-119-28803
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources#Inspections
 
| accessdate = 2015-05-27 }}</ref>
 
[[Category:Has Chemical Data]]
 
==Chemical Data==
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | HF Fluid Concentration
 
!scope="col" | Ingredient
 
!scope="col" | Additive Concentration
 
!scope="col" | Trade Name
 
!scope="col" | Purpose
 
!scope="col" | CAS number
 
!scope="col" | Supplier
 
 
|-
 
|-
| 68953.0
+
| 2018-06
| Quaternary ammonium compounds
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 161.00 Bbl
| Sand (Proppant)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| DWP-111
+
|  
| bis(hydrogenated ta
 
| DAP-903
 
 
|-
 
|-
 +
| 2018-07
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 177.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 0.00016
+
| 2018-08
| Ammonium Persulfate
+
| Produced Fluid (in Barrels) RWC 802
| 100.0
+
| style="text-align: right;" | 172.00 Bbl
| Sand (Proppant)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| DWP-111
+
|  
| 7727-54-0
 
| DAP-903
 
 
|-
 
|-
 +
| 2018-09
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 159.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 68951.0
+
| 2018-10
| Alcohols
+
| Produced Fluid (in Barrels) RWC 802
| 0.0
+
| style="text-align: right;" | 147.00 Bbl
| Sand (Proppant)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| DWP-111
+
|  
| C14-15
 
| DAP-903
 
 
|-
 
|-
 +
| 2018-11
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 147.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 6e-05
+
| 2018-12
| Sodium chloride
+
| Produced Fluid (in Barrels) RWC 802
| 0.1
+
| style="text-align: right;" | 139.00 Bbl
| Sand (Proppant)
+
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
| DWP-111
+
|  
| 7647-14-5
 
| DAP-903
 
 
|-
 
|-
 +
| 2019-01
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 265.00 Bbl
 +
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
 +
|
 
|-
 
|-
| 60.0
+
| 2019-02
| 2-Propenoic acid
+
| Produced Fluid (in Barrels) RWC 802
| 71050.0
+
| style="text-align: right;" | 277.00 Bbl
| Sand (Proppant)
+
| INJECTION DISPOSAL WELL
| DWP-111
+
| 34-119-28803
| polymer with sodium
 
| DAP-903
 
 
|-
 
|-
 +
| 2019-03
 +
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 310.00 Bbl
 +
| INJECTION DISPOSAL WELL
 +
| 34-119-28803
 
|-
 
|-
| 0.0
+
|}
| Oxirane
+
For data sources see<ref>{{cite web
| 0.0
+
| title =Oil and Gas Waste Reports
| Sand (Proppant)
+
|publisher = [[Pennsylvania Department of Environmental Protection]]
| DWP-111
+
| date = 2019-03-31
2-methyl-
+
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
| DAP-903
+
  | accessdate = 2019-05-21 }}</ref>
 +
== Inspection Data ==
 +
==== Inspections Performed ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Inspection Category
 +
!scope="col" | Inspection Date
 +
!scope="col" | Inspection Type
 +
!scope="col" | Inspection Result
 +
!scope="col" | Inspection Comments
 
|-
 
|-
 +
| 2168339
 +
| Primary Facility
 +
| 05/20/2013
 +
| Routine/Complete Inspection
 +
| No Violations Noted
 +
| Pre-operational inspection.  No violations but rocking and stabilizing work needs to be done.
 
|-
 
|-
| 0.0129
+
| 2182087
| Polyethylene glycol mixture
+
| Primary Facility
| 70.0
+
| 06/26/2013
| Sand (Proppant)
+
| Drilling/Alteration
| DWP-111
+
| No Violations Noted
| 25322-68-3
+
|  
|  DAP-903
 
 
|-
 
|-
 +
| 2199958
 +
| Primary Facility
 +
| 08/07/2013
 +
| Follow-up Inspection
 +
| No Violations Noted
 +
| On August 7, 2013, I conducted a follow-up inspection of CONSOL's NV-34 site; I met primarily with Dave Fedrick of CONSOL.
 
|-
 
|-
| 68607.0
+
| 2204362
| Dimethylcocoamine
+
| Primary Facility
| 0.0
+
| 09/11/2013
| Sand (Proppant)
+
| Drilling/Alteration
| DWP-111
+
| No Violations Noted
| bis(chloroethyl) et
+
|  
|  DAP-903
 
 
|-
 
|-
 +
| 2222555
 +
| Primary Facility
 +
| 10/30/2013
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
|
 
|-
 
|-
| 0.00156
+
| 2231182
| Diallyldimethylammonium chloride
+
| Primary Facility
| 5.0
+
| 12/09/2013
| Sand (Proppant)
+
| Drilling/Alteration
| DWP-111
+
| No Violations Noted
| 7398-69-8
+
|  
|  DAP-903
 
 
|-
 
|-
 +
| 2343194
 +
| Primary Facility
 +
| 02/08/2015
 +
| Drilling/Alteration
 +
| No Violations Noted
 +
| CNX bringing entire pad online to production.  Currently flaring large volume of gas to bring up pressure from well to producing pressure.  NOVIO
 
|-
 
|-
| 0.38965
+
| 2783487
| Hydrochloric acid
+
| Primary Facility
| 35.0
+
| 2018-09-27
| Sand (Proppant)
+
| Routine/Complete Inspection
| DWP-111
+
| No Violations Noted
| 7647-01-0
+
| On Thursday September 27, 2018, I conducted a routine-complete inspection at the NV34 Well Site located in Morris Township, Washington County.
|  DAP-903
+
 
 +
Gas well NV34CHS (125-24925) and the associated infrastructure appeared to be in good condition and functioning properly.  The well was tagged with identification.
 +
 
 +
No violations were identified during the inspection.
 
|-
 
|-
 +
|}
 +
<!--==== Violations Commited ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Inspection ID
 +
!scope="col" | Violation ID
 +
!scope="col" | Violation Date
 +
!scope="col" | Date Resolved
 +
!scope="col" | Violation Code
 +
!scope="col" | Violation Type
 +
!scope="col" | Violation Comments
 
|-
 
|-
| 25987.0
+
|}-->
| 2-Propenoic acid
+
<!--==== Penalties Applied ====
| 0.0
+
{| class="wikitable sortable" width="95%"
| Sand (Proppant)
+
!scope="col" | Violation ID
| DWP-111
+
!scope="col" | Penalty ID
| polymer with 2-prop
+
!scope="col" | Penalty Code
| DAP-903
+
!scope="col" | Penalty Status
 +
!scope="col" | Penalty Date
 +
!scope="col" | Enforcement Date
 +
!scope="col" | Penalty Amount
 +
!scope="col" | Amount Collected
 
|-
 
|-
 +
|}-->
 +
For data sources see<ref>{{cite web
 +
| title =Oil and Gas Compliance Report
 +
|publisher = [[Pennsylvania Department of Environmental Protection]]
 +
| date = 2019-05-20
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|-
| 60.0
+
| 1
| Distillates (petroleum)
+
| 10/09/2014
| 64742.0
+
| 11/14/2014
| Sand (Proppant)
+
| style="text-align: right;" | 7602
| DWP-111
+
| style="text-align: right;" | 12,660,800.0
| hydrotreated middle
+
| style="text-align: right;" | 0
| DAP-903
 
 
|-
 
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 
|-
 
|-
| 0.1
+
|- valign="top"
| Alkenes
+
| rowspan="31"| 1
| 64743.0
+
| rowspan="1"| Water
| Sand (Proppant)
+
| rowspan="1"| Customer & CWS
| DWP-111
+
| rowspan="1"| Base Fluid & Mix Water
| C>10 a-
+
| Water
| DAP-903
+
| 7732-18-5
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 89.1222
 +
| style="text-align: right;" | 105,672,000.0
 
|-
 
|-
 +
|- valign="top"
 +
| rowspan="30"| Sand (Proppant), DAP-903, DWP-111, DWP-614, DWP-901, BioClear 2000, DWP-NE1, Spearhead Acid
 +
| rowspan="30"| CWS
 +
| rowspan="30"| Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations
 +
| Poly(oxyethylene)nonylphenol ether
 +
| 9016-45-9
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00472
 +
| style="text-align: right;" | 5596.6
 
|-
 
|-
| 0.01246
+
| Methanol
| Isopropanol
+
| 67-56-1
| 40.0
+
| style="text-align: right;" | 15
| Sand (Proppant)
+
| style="text-align: right;" | 0.00801
| DWP-111
+
| style="text-align: right;" | 9500.66
| 67-63-0
 
| DAP-903
 
 
|-
 
|-
 +
| Ilmenite
 +
| 98072-94-7
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00207
 +
| style="text-align: right;" | 2457
 
|-
 
|-
| 0.00056
 
 
| Propargyl Alcohol
 
| Propargyl Alcohol
| 0.1
 
| Sand (Proppant)
 
|  DWP-111
 
 
| 107-19-7
 
| 107-19-7
| DAP-903
+
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00056
 +
| style="text-align: right;" | 660.02
 +
|-
 +
| 2-Propenoic acid, polymer with sodium phosphonate
 +
| 71050-62-9
 +
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00657
 +
| style="text-align: right;" | 7790.58
 
|-
 
|-
 +
| Sorbitan monooleate
 +
| 1338-43-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00472
 +
| style="text-align: right;" | 5596.6
 
|-
 
|-
| 0.00167
+
| Alcohols, C14-15, ethoxylated
| Modified thiourea polymer
+
| 68951-67-7
| 0.1
+
| style="text-align: right;" | 0.1
| Sand (Proppant)
+
| style="text-align: right;" | 0.00167
| DWP-111
+
| style="text-align: right;" | 1980.05
| 68527-49-1
+
|-
| DAP-903
+
| Illite
 +
| 12173-60-3
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.00559
 +
| style="text-align: right;" | 6633.9
 +
|-
 +
| Biotite
 +
| 1302-27-8
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0029
 +
| style="text-align: right;" | 3436.28
 +
|-
 +
| Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt
 +
| 68607-28-3
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.01246
 +
| style="text-align: right;" | 14774.8
 
|-
 
|-
 +
| Diallyldimethylammonium chloride
 +
| 7398-69-8
 +
| style="text-align: right;" | 5
 +
| style="text-align: right;" | 0.00156
 +
| style="text-align: right;" | 1846.85
 
|-
 
|-
| 0.00011
+
| Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite
| Formaldehyde
+
| 68953-58-2
| 0.1
+
| style="text-align: right;" | 5
| Sand (Proppant)
+
| style="text-align: right;" | 0.00046
| DWP-111
+
| style="text-align: right;" | 547.64
| 50-00-0
 
| DAP-903
 
 
|-
 
|-
 +
| Polyethylene glycol mixture
 +
| 25322-68-3
 +
| style="text-align: right;" | 70
 +
| style="text-align: right;" | 0.0129
 +
| style="text-align: right;" | 15290.1
 
|-
 
|-
| 20.0
+
| Isopropanol
| 2
+
| 67-63-0
| 10222.0
+
| style="text-align: right;" | 40
| Sand (Proppant)
+
| style="text-align: right;" | 0.01246
| DWP-111
+
| style="text-align: right;" | 14774.8
| 2-Dibromo-3-Nitrilop
 
| DAP-903
 
 
|-
 
|-
 +
| 2-Propenoic acid, polymer with 2-propenamide, sodium salt
 +
| 25987-30-8
 +
| style="text-align: right;" | 40
 +
| style="text-align: right;" | 0.03776
 +
| style="text-align: right;" | 44772.8
 
|-
 
|-
| 0.00472
+
| Hydrochloric acid
| Poly(oxyethylene)nonylphenol ether
+
| 7647-01-0
| 5.0
+
| style="text-align: right;" | 35
| Sand (Proppant)
+
| style="text-align: right;" | 0.38965
| DWP-111
+
| style="text-align: right;" | 462012
| 9016-45-9
 
| DAP-903
 
 
|-
 
|-
 +
| Fatty acids, tall-oil
 +
| 61790-12-3
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00167
 +
| style="text-align: right;" | 1980.05
 
|-
 
|-
| 0.00801
+
| Ammonium Persulfate
| Methanol
+
| 7727-54-0
| 15.0
+
| style="text-align: right;" | 100
| Sand (Proppant)
+
| style="text-align: right;" | 0.00016
| DWP-111
+
| style="text-align: right;" | 190
| 67-56-1
 
| DAP-903
 
 
|-
 
|-
 +
| Crystalline silica (Quartz)
 +
| 14808-60-7
 +
| style="text-align: right;" | 100
 +
| style="text-align: right;" | 10.2912
 +
| style="text-align: right;" | 12,202,300.0
 
|-
 
|-
| 0.00207
+
| Distillates (petroleum), hydrotreated middle
| Ilmenite
+
| 64742-46-7
| 0.1
+
| style="text-align: right;" | 60
| Sand (Proppant)
+
| style="text-align: right;" | 0.03386
| DWP-111
+
| style="text-align: right;" | 40151.3
| 98072-94-7
 
| DAP-903
 
 
|-
 
|-
 +
| Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether
 +
| 37251-67-5
 +
| style="text-align: right;" | 1.5
 +
| style="text-align: right;" | 0.00014
 +
| style="text-align: right;" | 164.29
 
|-
 
|-
| 0.0029
 
 
| Apatite
 
| Apatite
| 0.1
 
| Sand (Proppant)
 
|  DWP-111
 
 
| 64476-38-6
 
| 64476-38-6
| DAP-903
+
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.0029
 +
| style="text-align: right;" | 3436.28
 
|-
 
|-
 +
| Sodium chloride
 +
| 7647-14-5
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00006000
 +
| style="text-align: right;" | 66
 
|-
 
|-
| 0.00455
 
 
| Goethite
 
| Goethite
| 0.1
 
| Sand (Proppant)
 
|  DWP-111
 
 
| 1310-14-1
 
| 1310-14-1
| DAP-903
+
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00455
 +
| style="text-align: right;" | 5394.84
 
|-
 
|-
|-
 
| 0.1
 
| Fatty acids
 
| 61790.0
 
| Sand (Proppant)
 
|  DWP-111
 
|  tall-oil
 
|  DAP-903
 
|-
 
|-
 
| 0.00554
 
 
| Guar gum
 
| Guar gum
| 60.0
 
| Sand (Proppant)
 
|  DWP-111
 
 
| 9000-30-0
 
| 9000-30-0
| DAP-903
+
| style="text-align: right;" | 60
 +
| style="text-align: right;" | 0.00554
 +
| style="text-align: right;" | 6571.67
 
|-
 
|-
 +
| Calcite
 +
| 471-34-1
 +
| style="text-align: right;" | 1
 +
| style="text-align: right;" | 0.01734
 +
| style="text-align: right;" | 20564.9
 
|-
 
|-
| 0.00559
+
| Alkenes, C>10 a-
| Illite
+
| 64743-02-8
| 1.0
+
| style="text-align: right;" | 0.1
| Sand (Proppant)
+
| style="text-align: right;" | 0.00167
| DWP-111
+
| style="text-align: right;" | 1980.05
| 12173-60-3
 
| DAP-903
 
 
|-
 
|-
 +
| Modified thiourea polymer
 +
| 68527-49-1
 +
| style="text-align: right;" | 0.1
 +
| style="text-align: right;" | 0.00167
 +
| style="text-align: right;" | 1980.05
 
|-
 
|-
| 0.00472
+
| Formaldehyde
| Sorbitan monooleate
+
| 50-00-0
| 5.0
+
| style="text-align: right;" | 0.1
| Sand (Proppant)
+
| style="text-align: right;" | 0.00011
| DWP-111
+
| style="text-align: right;" | 132
| 1338-43-8
 
| DAP-903
 
|-
 
 
|-
 
|-
| 89.1222
+
| 2,2-Dibromo-3-Nitrilopropionamide
| Water
+
| 10222-01-2
| 100.0
+
| style="text-align: right;" | 20
| Water
+
| style="text-align: right;" | 0.0129
| Base Fluid & Mix Water
+
| style="text-align: right;" | 15290.1
| 7732-18-5
 
| Customer & CWS
 
 
|-
 
|-
 
|}
 
|}
For data sources see<ref>{{cite web | title = FracFocus Chemical Disclosure Registry |publisher = [http://www.fracfocusdata.org/DisclosureSearch/]| date = 2015-08-10 | url = http://wellwiki.org/wiki/Well_Chemicals_Data_Sources | accessdate = 2015-08-10 }}</ref>
+
For data sources see<ref>{{cite web
== References ==
+
| title =FracFocus Fracking Chemicals Database
{{reflist}}
+
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 +
==References==
 +
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
[[Category:Wells]]
+
[[Category:Pennsylvania Wells]]
 +
[[Category:FracFocus]]

Revision as of 12:01, 15 July 2019

Well Details

Well ID: 37-125-24925
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: Morris Township
Operator Name: HG ENERGY II APPALACHIA LLC
Well Pad ID: 145656
Farm/Lease Name: COFFIELD/GOTTSCHALK NV34CHS
License Status: Active
Spud Date: 06/19/2013
Permit Date: 12/17/2012
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.051542
Longitude: -80.319114

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2014 CNX GAS CO LLC 0.00 0 0.00 0 0.00 0
2015 CNX GAS CO LLC 1,368,507.53 327 0.00 0 0.00 0
2016 CNX GAS CO LLC 1,096,493.65 364 0.00 0 0.00 0
2017 CNX GAS CO LLC 900,645.04 363 0.00 0 0.00 0
2018 HG ENERGY II APPALACHIA LLC 854,691.00 365 0.00 0 0.00 0
2019 HG ENERGY II APPALACHIA LLC 98,320.00 59 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
15AUGU Produced Fluid (in Barrels) 3,194.97 Bbl REUSE OTHER THAN ROAD SPREADING
15DECU Produced Fluid (in Barrels) 1,822.80 Bbl REUSE OTHER THAN ROAD SPREADING
15JULU Produced Fluid (in Barrels) 3,272.09 Bbl REUSE OTHER THAN ROAD SPREADING
15NOVU Produced Fluid (in Barrels) 2,225.49 Bbl REUSE OTHER THAN ROAD SPREADING
15OCTU Produced Fluid (in Barrels) 2,389.36 Bbl REUSE OTHER THAN ROAD SPREADING
15SEPU Produced Fluid (in Barrels) 2,505.74 Bbl REUSE OTHER THAN ROAD SPREADING
16APRU Produced Fluid (in Barrels) RWC 802 1,455.05 Bbl REUSE OTHER THAN ROAD SPREADING
16AUGU Produced Fluid (in Barrels) RWC 802 1,167.00 Bbl REUSE OTHER THAN ROAD SPREADING
16DECU Produced Fluid (in Barrels) RWC 802 381.00 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 1,451.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JANU Produced Fluid (in Barrels) RWC 802 1,749.81 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 936.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JUNU Produced Fluid (in Barrels) RWC 802 62.06 Bbl INJECTION DISPOSAL WELL 34-013-20609
16JUNU Produced Fluid (in Barrels) RWC 802 24.60 Bbl INJECTION DISPOSAL WELL 34-119-28780
16JUNU Produced Fluid (in Barrels) RWC 802 214.05 Bbl INJECTION DISPOSAL WELL 34-119-28803
16JUNU Produced Fluid (in Barrels) RWC 802 885.80 Bbl REUSE OTHER THAN ROAD SPREADING
16MARU Fracturing Fluid Waste (in Barrels) RWC 805 10.00 Bbl REUSE OTHER THAN ROAD SPREADING
16MARU Produced Fluid (in Barrels) RWC 802 1,431.36 Bbl REUSE OTHER THAN ROAD SPREADING
16MAYU Produced Fluid (in Barrels) RWC 802 12.27 Bbl INJECTION DISPOSAL WELL 34-013-20609
16MAYU Produced Fluid (in Barrels) RWC 802 11.20 Bbl INJECTION DISPOSAL WELL 34-119-28780
16MAYU Produced Fluid (in Barrels) RWC 802 32.17 Bbl INJECTION DISPOSAL WELL 34-119-28803
16MAYU Produced Fluid (in Barrels) RWC 802 1,076.60 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 125.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
16NOVU Produced Fluid (in Barrels) RWC 802 12.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
16NOVU Produced Fluid (in Barrels) RWC 802 134.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
16NOVU Produced Fluid (in Barrels) RWC 802 523.00 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 275.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
16OCTU Produced Fluid (in Barrels) RWC 802 21.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
16OCTU Produced Fluid (in Barrels) RWC 802 312.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
16OCTU Produced Fluid (in Barrels) RWC 802 272.00 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 1,155.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Drill Cuttings (in Tons) 194.82 Tons LANDFILL PAD059087072
2013-2 Drill Cuttings (in Tons) 210.33 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2013-2 Drilling Fluid Waste (in Barrels) 92.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 301071
2014-1 Drill Cuttings (in Tons) 45.70 Tons LANDFILL PAD059087072
2014-1 Drill Cuttings (in Tons) 465.34 Tons RESIDUAL WASTE TRANSFER FACILITY 301071
2014-1 Drilling Fluid Waste (in Barrels) 0.25 Bbl RESIDUAL WASTE TRANSFER FACILITY 301071
2014-2 Fracing Fluid Waste (in Barrels) 3,134.18 Bbl REUSE OTHER THAN ROAD SPREADING
2015-07 Produced Fluid (in Barrels) 3,272.09 Bbl REUSE OTHER THAN ROAD SPREADING
2015-08 Produced Fluid (in Barrels) 3,194.97 Bbl REUSE OTHER THAN ROAD SPREADING
2015-09 Produced Fluid (in Barrels) 2,505.74 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Fracing Fluid Waste (in Barrels) 587.95 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Fracturing Fluid Waste (in Tons) 12.69 Tons LANDFILL 100172
2015-1 Produced Fluid (in Barrels) 13,256.19 Bbl REUSE OTHER THAN ROAD SPREADING
2015-10 Produced Fluid (in Barrels) 2,389.36 Bbl REUSE OTHER THAN ROAD SPREADING
2015-11 Produced Fluid (in Barrels) 2,225.49 Bbl REUSE OTHER THAN ROAD SPREADING
2015-12 Produced Fluid (in Barrels) 1,822.80 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 1,749.81 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 1,451.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-03 Fracturing Fluid Waste (in Barrels) RWC 805 10.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-03 Produced Fluid (in Barrels) RWC 802 1,431.36 Bbl REUSE OTHER THAN ROAD SPREADING
2016-04 Produced Fluid (in Barrels) RWC 802 1,455.05 Bbl REUSE OTHER THAN ROAD SPREADING
2016-05 Produced Fluid (in Barrels) RWC 802 12.27 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-05 Produced Fluid (in Barrels) RWC 802 11.20 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-05 Produced Fluid (in Barrels) RWC 802 32.17 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-05 Produced Fluid (in Barrels) RWC 802 1,076.60 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 62.06 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-06 Produced Fluid (in Barrels) RWC 802 24.60 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-06 Produced Fluid (in Barrels) RWC 802 214.05 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-06 Produced Fluid (in Barrels) RWC 802 885.80 Bbl REUSE OTHER THAN ROAD SPREADING
2016-07 Produced Fluid (in Barrels) RWC 802 936.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-08 Produced Fluid (in Barrels) RWC 802 1,167.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-09 Produced Fluid (in Barrels) RWC 802 1,155.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-10 Produced Fluid (in Barrels) RWC 802 275.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-10 Produced Fluid (in Barrels) RWC 802 21.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-10 Produced Fluid (in Barrels) RWC 802 312.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-10 Produced Fluid (in Barrels) RWC 802 272.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 125.00 Bbl INJECTION DISPOSAL WELL 34-013-20609
2016-11 Produced Fluid (in Barrels) RWC 802 12.00 Bbl INJECTION DISPOSAL WELL 34-119-28780
2016-11 Produced Fluid (in Barrels) RWC 802 134.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2016-11 Produced Fluid (in Barrels) RWC 802 523.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-12 Produced Fluid (in Barrels) RWC 802 381.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 423.84 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-02 Produced Fluid (in Barrels) RWC 802 369.61 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-05 Produced Fluid (in Barrels) RWC 802 289.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-06 Produced Fluid (in Barrels) RWC 802 439.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-07 Produced Fluid (in Barrels) RWC 802 352.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-08 Produced Fluid (in Barrels) RWC 802 691.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-09 Produced Fluid (in Barrels) RWC 802 562.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2017-10 Produced Fluid (in Barrels) RWC 802 565.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-11 Produced Fluid (in Barrels) RWC 802 565.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017-12 Produced Fluid (in Barrels) RWC 802 742.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-01 Produced Fluid (in Barrels) RWC 802 362.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-02 Produced Fluid (in Barrels) RWC 802 351.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-03 Produced Fluid (in Barrels) RWC 802 320.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-04 Produced Fluid (in Barrels) RWC 802 256.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-05 Produced Fluid (in Barrels) RWC 802 219.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-06 Produced Fluid (in Barrels) RWC 802 161.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-07 Produced Fluid (in Barrels) RWC 802 177.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-08 Produced Fluid (in Barrels) RWC 802 172.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-09 Produced Fluid (in Barrels) RWC 802 159.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2018-10 Produced Fluid (in Barrels) RWC 802 147.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-11 Produced Fluid (in Barrels) RWC 802 147.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018-12 Produced Fluid (in Barrels) RWC 802 139.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-01 Produced Fluid (in Barrels) RWC 802 265.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2019-02 Produced Fluid (in Barrels) RWC 802 277.00 Bbl INJECTION DISPOSAL WELL 34-119-28803
2019-03 Produced Fluid (in Barrels) RWC 802 310.00 Bbl INJECTION DISPOSAL WELL 34-119-28803

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2168339 Primary Facility 05/20/2013 Routine/Complete Inspection No Violations Noted Pre-operational inspection. No violations but rocking and stabilizing work needs to be done.
2182087 Primary Facility 06/26/2013 Drilling/Alteration No Violations Noted
2199958 Primary Facility 08/07/2013 Follow-up Inspection No Violations Noted On August 7, 2013, I conducted a follow-up inspection of CONSOL's NV-34 site; I met primarily with Dave Fedrick of CONSOL.
2204362 Primary Facility 09/11/2013 Drilling/Alteration No Violations Noted
2222555 Primary Facility 10/30/2013 Drilling/Alteration No Violations Noted
2231182 Primary Facility 12/09/2013 Drilling/Alteration No Violations Noted
2343194 Primary Facility 02/08/2015 Drilling/Alteration No Violations Noted CNX bringing entire pad online to production. Currently flaring large volume of gas to bring up pressure from well to producing pressure. NOVIO
2783487 Primary Facility 2018-09-27 Routine/Complete Inspection No Violations Noted On Thursday September 27, 2018, I conducted a routine-complete inspection at the NV34 Well Site located in Morris Township, Washington County.

Gas well NV34CHS (125-24925) and the associated infrastructure appeared to be in good condition and functioning properly. The well was tagged with identification.

No violations were identified during the inspection.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/09/2014 11/14/2014 7602 12,660,800.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 89.1222 105,672,000.0
Sand (Proppant), DAP-903, DWP-111, DWP-614, DWP-901, BioClear 2000, DWP-NE1, Spearhead Acid CWS Propping Agent, Scale Inhibitor, Gel Slurry, Viscosifier, Breaker, Biocide, Non-Emulsifier, Clean Perforations Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.00472 5596.6
Methanol 67-56-1 15 0.00801 9500.66
Ilmenite 98072-94-7 0.1 0.00207 2457
Propargyl Alcohol 107-19-7 0.1 0.00056 660.02
2-Propenoic acid, polymer with sodium phosphonate 71050-62-9 60 0.00657 7790.58
Sorbitan monooleate 1338-43-8 5 0.00472 5596.6
Alcohols, C14-15, ethoxylated 68951-67-7 0.1 0.00167 1980.05
Illite 12173-60-3 1 0.00559 6633.9
Biotite 1302-27-8 0.1 0.0029 3436.28
Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt 68607-28-3 40 0.01246 14774.8
Diallyldimethylammonium chloride 7398-69-8 5 0.00156 1846.85
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite 68953-58-2 5 0.00046 547.64
Polyethylene glycol mixture 25322-68-3 70 0.0129 15290.1
Isopropanol 67-63-0 40 0.01246 14774.8
2-Propenoic acid, polymer with 2-propenamide, sodium salt 25987-30-8 40 0.03776 44772.8
Hydrochloric acid 7647-01-0 35 0.38965 462012
Fatty acids, tall-oil 61790-12-3 0.1 0.00167 1980.05
Ammonium Persulfate 7727-54-0 100 0.00016 190
Crystalline silica (Quartz) 14808-60-7 100 10.2912 12,202,300.0
Distillates (petroleum), hydrotreated middle 64742-46-7 60 0.03386 40151.3
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether 37251-67-5 1.5 0.00014 164.29
Apatite 64476-38-6 0.1 0.0029 3436.28
Sodium chloride 7647-14-5 0.1 0.00006000 66
Goethite 1310-14-1 0.1 0.00455 5394.84
Guar gum 9000-30-0 60 0.00554 6571.67
Calcite 471-34-1 1 0.01734 20564.9
Alkenes, C>10 a- 64743-02-8 0.1 0.00167 1980.05
Modified thiourea polymer 68527-49-1 0.1 0.00167 1980.05
Formaldehyde 50-00-0 0.1 0.00011 132
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 20 0.0129 15290.1

For data sources see[7]

References