X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-015-22202"

m
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-015-22202
 
| Well ID: 37-015-22202
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.602181, -76.400728 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.602181, -76.400728 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 06/11/2012
+
| Spud Date: 2012-06-11
 
|-
 
|-
| Permit Date: 5/2/2012
+
| Permit Date: 2012-05-02
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2013-01-12
 +
| 2013-01-12
 +
| style="text-align: right;" | 8038.00
 +
| style="text-align: right;" | 5,460,126.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="23"| 1
 +
| rowspan="1"| 100 Mesh Sand
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Proppant - Natural
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 1.40
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| 10.1 - 15 HCL
 +
| rowspan="2"| FTS International
 +
| rowspan="2"| Acid
 +
| Hydrochloric acid
 +
| 7647-01-0
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 85.00
 +
| style="text-align: right;" | 0.18
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Recycled Produced Water
 +
| rowspan="2"|
 +
| rowspan="2"| Carrier/Base Fluid
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 28.12
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| B84, SC30
 +
| rowspan="1"| X-Chem
 +
| rowspan="1"| Anti-Bacterial Agent, Scale Inhibitor
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| B-84
 +
| rowspan="4"| X-Chem
 +
| rowspan="4"| Antibacterial Agent
 +
| Quaternary ammonium compounds,<br/> benzyl-C12-16-alkyldimethyl, chlorides
 +
| 68424-85-1
 +
| style="text-align: right;" | 6.00
 +
| style="text-align: right;" | 0.00149000
 +
| style="text-align: right;" |
 +
|-
 +
| Glutaraldehyde
 +
| 111-30-8
 +
| style="text-align: right;" | 27.00
 +
| style="text-align: right;" | 0.00733000
 +
| style="text-align: right;" |
 +
|-
 +
| Didecyl dimethyl ammonium chloride
 +
| 7173-51-5
 +
| style="text-align: right;" | 8.00
 +
| style="text-align: right;" | 0.00217000
 +
| style="text-align: right;" |
 +
|-
 +
| Ethanol
 +
| 64-17-5
 +
| style="text-align: right;" | 4.00
 +
| style="text-align: right;" | 0.00109000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FRW-600
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Friction Reducer
 +
| Distillates, petroleum, hydrotreated light
 +
| 64742-47-8
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.01
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Fresh Water
 +
| rowspan="1"|
 +
| rowspan="1"| Carrier/Base Fluid
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 57.22
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="4"| CI-150 (Corrosion Inhibitor)
 +
| rowspan="4"| FTS International
 +
| rowspan="4"| Corrosion Inhibitor
 +
| N,N-Dimethylformamide
 +
| 68-12-2
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
| Isopropanol
 +
| 67-63-0
 +
| style="text-align: right;" | 60.00
 +
| style="text-align: right;" | 0.00040000
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Organic Amine Resin Salt
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00020000
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Aromatic Aldehyde
 +
|
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00007000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="3"| CI-150, FE-100L, FRW-600
 +
| rowspan="3"| FTS International
 +
| rowspan="3"| Corrosion Inhibitor, Friction Reducer, Iron Control Agent
 +
| Proprietary Corrosion Inhibitor Additive (CI-150)
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Proprietary Friction Reducer Additive (FRW-600)
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
| Water
 +
| 7732-18-5
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| SC-30
 +
| rowspan="1"| X-Chem
 +
| rowspan="1"| Scale Inhibitor
 +
| Sodium polyacrylate
 +
| 9003-04-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00891000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Northern White Sand
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Proppant - Natural
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 12.93
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| FE 100L (Iron Chelator)
 +
| rowspan="1"| FTS International
 +
| rowspan="1"| Iron Control Agent
 +
| Citric acid
 +
| 77-92-9
 +
| style="text-align: right;" | 55.00
 +
| style="text-align: right;" | 0.00064000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Additional Ingredients Not Listed on MSDS
 +
| rowspan="1"|
 +
| rowspan="1"|
 +
|
 +
|
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 142: Line 369:
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Period
 
!scope="col" | Period
 +
!scope="col" | Operator
 
!scope="col" | Waste Type
 
!scope="col" | Waste Type
 
!scope="col" | Quantity
 
!scope="col" | Quantity
Line 147: Line 375:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2012-2
+
| 2012
| Drill Cuttings (in Tons)
+
| [[CHESAPEAKE APPALACHIA LLC]]
| style="text-align: right;" | 719.43 Tons
 
| LANDFILL
 
| 8-0728-0004/013
 
|-
 
| 2012-2
 
 
| Drill Cuttings (in Tons)
 
| Drill Cuttings (in Tons)
 
| style="text-align: right;" | 521.07 Tons
 
| style="text-align: right;" | 521.07 Tons
Line 159: Line 382:
 
| THR029
 
| THR029
 
|-
 
|-
| 2012-2
+
| 2012
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Drilling Fluid Waste (in Barrels)
 
| Drilling Fluid Waste (in Barrels)
 
| style="text-align: right;" | 1,329.29 Bbl
 
| style="text-align: right;" | 1,329.29 Bbl
Line 165: Line 389:
 
|  
 
|  
 
|-
 
|-
| 2012-2
+
| 2012
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 +
| Drill Cuttings (in Tons)
 +
| style="text-align: right;" | 719.43 Tons
 +
| LANDFILL
 +
| 8-0728-0004/013
 +
|-
 +
| 2012
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 1,206.62 Bbl
 
| style="text-align: right;" | 1,206.62 Bbl
Line 171: Line 403:
 
|  
 
|  
 
|-
 
|-
| 2013-1
+
| 2013
| Produced Fluid (in Barrels)
+
| [[CHESAPEAKE APPALACHIA LLC]]
| style="text-align: right;" | 52.00 Bbl
 
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
 
| WMGR119
 
|-
 
| 2013-1
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 5,843.60 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2013-2
 
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 216.00 Bbl
 
| style="text-align: right;" | 216.00 Bbl
Line 189: Line 410:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2013-2
+
| 2013
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 1,281.00 Bbl
+
| style="text-align: right;" | 52.00 Bbl
| REUSE OTHER THAN ROAD SPREADING
+
| CENTRALIZED TREATMENT PLANT FOR RECYCLE
|  
+
| WMGR119
 
|-
 
|-
| 2014-1
+
| 2013
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 564.19 Bbl
+
| style="text-align: right;" | 7,124.60 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2014-2
+
| 2014
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 207.48 Bbl
+
| style="text-align: right;" | 771.67 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-1
+
| 2015
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
| style="text-align: right;" | 115.50 Bbl
+
| style="text-align: right;" | 260.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2016
| Produced Fluid (in Barrels)
+
| [[CHESAPEAKE APPALACHIA LLC]]
| style="text-align: right;" | 144.50 Bbl
+
| Produced Fluid (in Barrels) RWC 802
 +
| style="text-align: right;" | 157.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
| REUSE OTHER THAN ROAD SPREADING
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 67.50 Bbl
 
| style="text-align: right;" | 67.50 Bbl
Line 225: Line 452:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2016-2
+
| 2018
| Produced Fluid (in Barrels) RWC 802
+
| [[CHESAPEAKE APPALACHIA LLC]]
| style="text-align: right;" | 157.00 Bbl
 
| REUSE OTHER THAN ROAD SPREADING
 
|
 
|-
 
| 2018-03
 
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 108.00 Bbl
 
| style="text-align: right;" | 108.00 Bbl
Line 237: Line 459:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 +
| Waste Water Treatment Sludge (in Tons) RWC 804
 +
| style="text-align: right;" | 2.18 Tons
 +
| LANDFILL
 +
| 301626
 +
|-
 +
| 2018
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 8.50 Bbl
 
| style="text-align: right;" | 8.50 Bbl
Line 243: Line 473:
 
| WMGR123NC008
 
| WMGR123NC008
 
|-
 
|-
| 2018-05
+
| 2018
 +
| [[CHESAPEAKE APPALACHIA LLC]]
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 46.50 Bbl
 
| style="text-align: right;" | 46.50 Bbl
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| RESIDUAL WASTE PROCESSING FACILITY
 
| WMGR123NC008
 
| WMGR123NC008
|-
 
| 2018-05
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 1.50 Tons
 
| LANDFILL
 
| 301626
 
|-
 
| 2018-06
 
| Waste Water Treatment Sludge (in Tons) RWC 804
 
| style="text-align: right;" | 0.68 Tons
 
| LANDFILL
 
| 301626
 
 
|-
 
|-
 
|}
 
|}
Line 280: Line 499:
 
| 2070322
 
| 2070322
 
| Primary Facility
 
| Primary Facility
| 05/23/2012
+
| 2012-05-23
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 287: Line 506:
 
| 2084459
 
| 2084459
 
| Primary Facility
 
| Primary Facility
| 07/12/2012
+
| 2012-07-12
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 294: Line 513:
 
| 2084577
 
| 2084577
 
| Primary Facility
 
| Primary Facility
| 07/19/2012
+
| 2012-07-19
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 301: Line 520:
 
| 2103342
 
| 2103342
 
| Primary Facility
 
| Primary Facility
| 09/27/2012
+
| 2012-09-27
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 308: Line 527:
 
| 2109994
 
| 2109994
 
| Primary Facility
 
| Primary Facility
| 10/15/2012
+
| 2012-10-15
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Outstanding Violations - No Viols Req'd
 
| Outstanding Violations - No Viols Req'd
Line 315: Line 534:
 
| 2140079
 
| 2140079
 
| Primary Facility
 
| Primary Facility
| 01/31/2013
+
| 2013-01-31
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| Outstanding Violations - No Viols Req'd
 
| Outstanding Violations - No Viols Req'd
Line 322: Line 541:
 
| 2146531
 
| 2146531
 
| Primary Facility
 
| Primary Facility
| 03/07/2013
+
| 2013-03-07
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Outstanding Violations - No Viols Req'd
 
| Outstanding Violations - No Viols Req'd
Line 329: Line 548:
 
| 2307895
 
| 2307895
 
| Primary Facility
 
| Primary Facility
| 09/24/2014
+
| 2014-09-24
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 376: Line 595:
 
| 650315
 
| 650315
 
| 09/27/2012
 
| 09/27/2012
| 04/12/2013
+
| 2012-09-27
 
| 78.81D1 - Failure to maintain control of anticipated gas storage reservoir pressures while drilling through reservoir or protective area
 
| 78.81D1 - Failure to maintain control of anticipated gas storage reservoir pressures while drilling through reservoir or protective area
 
| Administrative
 
| Administrative
Line 400: Line 619:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 01/12/2013
 
| 01/12/2013
 
| style="text-align: right;" | 8038.00
 
| style="text-align: right;" | 5,460,126.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="23"| 1
 
| rowspan="1"| 100 Mesh Sand
 
| rowspan="1"| FTS International
 
| rowspan="1"| Proppant - Natural
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 1.40
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| 10.1 - 15 HCL
 
| rowspan="2"| FTS International
 
| rowspan="2"| Acid
 
| Hydrochloric acid
 
| 7647-01-0
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.03
 
| style="text-align: right;" |
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 85.00
 
| style="text-align: right;" | 0.18
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Recycled Produced Water
 
| rowspan="2"|
 
| rowspan="2"| Carrier/Base Fluid
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 28.12
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| B84, SC30
 
| rowspan="1"| X-Chem
 
| rowspan="1"| Anti-Bacterial Agent, Scale Inhibitor
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="4"| B-84
 
| rowspan="4"| X-Chem
 
| rowspan="4"| Antibacterial Agent
 
| Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides
 
| 68424-85-1
 
| style="text-align: right;" | 6.00
 
| style="text-align: right;" | 0.00149000
 
| style="text-align: right;" |
 
|-
 
| Glutaraldehyde
 
| 111-30-8
 
| style="text-align: right;" | 27.00
 
| style="text-align: right;" | 0.00733000
 
| style="text-align: right;" |
 
|-
 
| Didecyl dimethyl ammonium chloride
 
| 7173-51-5
 
| style="text-align: right;" | 8.00
 
| style="text-align: right;" | 0.00217000
 
| style="text-align: right;" |
 
|-
 
| Ethanol
 
| 64-17-5
 
| style="text-align: right;" | 4.00
 
| style="text-align: right;" | 0.00109000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| FRW-600
 
| rowspan="1"| FTS International
 
| rowspan="1"| Friction Reducer
 
| Distillates, petroleum, hydrotreated light
 
| 64742-47-8
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.01
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Fresh Water
 
| rowspan="1"|
 
| rowspan="1"| Carrier/Base Fluid
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 57.22
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="4"| CI-150 (Corrosion Inhibitor)
 
| rowspan="4"| FTS International
 
| rowspan="4"| Corrosion Inhibitor
 
| N,N-Dimethylformamide
 
| 68-12-2
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00007000
 
| style="text-align: right;" |
 
|-
 
| Isopropanol
 
| 67-63-0
 
| style="text-align: right;" | 60.00
 
| style="text-align: right;" | 0.00040000
 
| style="text-align: right;" |
 
|-
 
| Proprietary Organic Amine Resin Salt
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00020000
 
| style="text-align: right;" |
 
|-
 
| Proprietary Aromatic Aldehyde
 
|
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00007000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="3"| CI-150, FE-100L, FRW-600
 
| rowspan="3"| FTS International
 
| rowspan="3"| Corrosion Inhibitor, Friction Reducer, Iron Control Agent
 
| Proprietary Corrosion Inhibitor Additive (CI-150)
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Proprietary Friction Reducer Additive (FRW-600)
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
| Water
 
| 7732-18-5
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| SC-30
 
| rowspan="1"| X-Chem
 
| rowspan="1"| Scale Inhibitor
 
| Sodium polyacrylate
 
| 9003-04-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00891000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Northern White Sand
 
| rowspan="1"| FTS International
 
| rowspan="1"| Proppant - Natural
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 12.93
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| FE 100L (Iron Chelator)
 
| rowspan="1"| FTS International
 
| rowspan="1"| Iron Control Agent
 
| Citric acid
 
| 77-92-9
 
| style="text-align: right;" | 55.00
 
| style="text-align: right;" | 0.00064000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Additional Ingredients Not Listed on MSDS
 
| rowspan="1"|
 
| rowspan="1"|
 
|
 
|
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 11:29, 20 August 2019

Well Details

Well ID: 37-015-22202
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Albany Township
Operator Name: CHESAPEAKE APPALACHIA LLC
Well Pad ID: 145323
Farm/Lease Name: SCHLAPFER N BRA 2H
License Status: Active
Spud Date: 2012-06-11
Permit Date: 2012-05-02
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.602181
Longitude: -76.400728

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-01-12 2013-01-12 8038.00 5,460,126.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 100 Mesh Sand FTS International Proppant - Natural Quartz 14808-60-7 100.00 1.40
10.1 - 15 HCL FTS International Acid Hydrochloric acid 7647-01-0 15.00 0.03
Water 7732-18-5 85.00 0.18
Recycled Produced Water Carrier/Base Fluid
Water 7732-18-5 100.00 28.12
B84, SC30 X-Chem Anti-Bacterial Agent, Scale Inhibitor Water 7732-18-5
B-84 X-Chem Antibacterial Agent Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 6.00 0.00149000
Glutaraldehyde 111-30-8 27.00 0.00733000
Didecyl dimethyl ammonium chloride 7173-51-5 8.00 0.00217000
Ethanol 64-17-5 4.00 0.00109000
FRW-600 FTS International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Fresh Water Carrier/Base Fluid Water 7732-18-5 100.00 57.22
CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor N,N-Dimethylformamide 68-12-2 10.00 0.00007000
Isopropanol 67-63-0 60.00 0.00040000
Proprietary Organic Amine Resin Salt 30.00 0.00020000
Proprietary Aromatic Aldehyde 10.00 0.00007000
CI-150, FE-100L, FRW-600 FTS International Corrosion Inhibitor, Friction Reducer, Iron Control Agent Proprietary Corrosion Inhibitor Additive (CI-150)
Proprietary Friction Reducer Additive (FRW-600)
Water 7732-18-5
SC-30 X-Chem Scale Inhibitor Sodium polyacrylate 9003-04-7 100.00 0.00891000
Northern White Sand FTS International Proppant - Natural Quartz 14808-60-7 100.00 12.93
FE 100L (Iron Chelator) FTS International Iron Control Agent Citric acid 77-92-9 55.00 0.00064000
Additional Ingredients Not Listed on MSDS

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHESAPEAKE APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHESAPEAKE APPALACHIA LLC 1,739,725.00 227 0.00 0 0.00 0
2014 CHESAPEAKE APPALACHIA LLC 1,736,934.00 362 0.00 0 0.00 0
2015 CHESAPEAKE APPALACHIA LLC 1,432,420.00 365 0.00 0 0.00 0
2016 CHESAPEAKE APPALACHIA LLC 1,236,298.00 345 0.00 0 0.00 0
2017 CHESAPEAKE APPALACHIA LLC 1,005,467.00 331 0.00 0 0.00 0
2018 CHESAPEAKE APPALACHIA LLC 954,144.00 352 0.00 0 0.00 0
2019 CHESAPEAKE APPALACHIA LLC 226,475.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHESAPEAKE APPALACHIA LLC Drill Cuttings (in Tons) 521.07 Tons LANDFILL THR029
2012 CHESAPEAKE APPALACHIA LLC Drilling Fluid Waste (in Barrels) 1,329.29 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHESAPEAKE APPALACHIA LLC Drill Cuttings (in Tons) 719.43 Tons LANDFILL 8-0728-0004/013
2012 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 1,206.62 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 216.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 52.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 7,124.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 771.67 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) 260.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 157.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 67.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 108.00 Bbl REUSE (AT WELL PAD)
2018 CHESAPEAKE APPALACHIA LLC Waste Water Treatment Sludge (in Tons) RWC 804 2.18 Tons LANDFILL 301626
2018 CHESAPEAKE APPALACHIA LLC Other Oil & Gas Wastes (in Barrels) RWC 899 8.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008
2018 CHESAPEAKE APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 46.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC008

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2070322 Primary Facility 2012-05-23 Routine/Complete Inspection No Violations Noted
2084459 Primary Facility 2012-07-12 Drilling/Alteration No Violations Noted NOMAC 112, Comp. Man - Brad Merryfield drilling @ 6480'
2084577 Primary Facility 2012-07-19 Drilling/Alteration No Violations Noted NOMAC 112, Comp. Man - Dustin Smith, drilling at 12,083' TD @ 13,988'
2103342 Primary Facility 2012-09-27 Follow-up Inspection Violation(s) Noted Recieved notification of bubbles in cond X 13 3/8" annular space on Sept 24, 2012(e-mail from Jennifer Hoffman, Chesapeake). Bubbles are visible. Was able to get a reading of 11% LEL on MSA Altair multi-meter. (cellar is about 15' deep). I got a reading of XXX LEL(100%) and 100% methane from the 9 5/8 X 13 3/8" vent. Plastic containment with waste needs to be removed from site.
2109994 Primary Facility 2012-10-15 Follow-up Inspection Outstanding Violations - No Viols Req'd Cap has been installed on cond x surf = 20 X 13 3/8" annulus.
2140079 Primary Facility 2013-01-31 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Frac tanks on site. Some water on site.
2146531 Primary Facility 2013-03-07 Follow-up Inspection Outstanding Violations - No Viols Req'd On site to monitor csg annuli for gas.
2307895 Primary Facility 2014-09-24 Routine/Complete Inspection No Violations Noted
2505904 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2569024 Primary Facility 2017-03-08 Routine/Complete Inspection No Violations Noted Two Wells in production phase. To each sand and water separators. No leaks detected from production equipment. Site stable. No violations noted.
2712082 Primary Facility 2018-03-29 Routine/Complete Inspection No Violations Noted Two wells staged for production phase. Two each sand and water separators. No leaks detected from production equipment. No violations noted.
2712085 Primary Facility 2018-03-29 Routine/Complete Inspection No Violations Noted Two wells staged for production phase. Two each sand and water separators. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2103342 650315 09/27/2012 2012-09-27 78.81D1 - Failure to maintain control of anticipated gas storage reservoir pressures while drilling through reservoir or protective area Administrative

For data sources see[7]

References