{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-117-20621
 
| Well ID: 37-117-20621
| style="height=100%; align=center" rowspan="14" | {{#display_map: 41.689756, -77.560883 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 41.689756, -77.560883 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Active
 
| License Status: Active
 
|-
 
|-
| Spud Date: 09/28/2010
+
| Spud Date: 2010-09-28
 
|-
 
|-
| Permit Date: 3/23/2010
+
| Permit Date: 2010-03-23
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
| 1
 +
| 2011-04-17
 +
| 2011-04-17
 +
| style="text-align: right;" | 6217.00
 +
| style="text-align: right;" | 5,116,923.0
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|- valign="top"
 +
| rowspan="15"| 1
 +
| rowspan="4"| A264 Corrosion Inhibitor
 +
| rowspan="4"| Schlumberger
 +
| rowspan="4"| Corrosion Inhibitor
 +
| Methanol
 +
| 67-56-1
 +
| style="text-align: right;" | 40.00
 +
| style="text-align: right;" | 0.00016000
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic acids
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00012000
 +
| style="text-align: right;" |
 +
|-
 +
| Aliphatic alcohols, ethoxylated #1
 +
|
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.00012000
 +
| style="text-align: right;" |
 +
|-
 +
| Propargyl alcohol
 +
| 107-19-7
 +
| style="text-align: right;" | 10.00
 +
| style="text-align: right;" | 0.00004000
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| L058
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Iron Control
 +
| Sodium erythorbate
 +
| 6381-77-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00025800
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| J609
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Friction Reducer
 +
| Ammonium sulfate
 +
| 7783-20-2
 +
| style="text-align: right;" | 30.00
 +
| style="text-align: right;" | 0.03
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| Scale Inhibitor B317
 +
| rowspan="2"| Schlumberger
 +
| rowspan="2"| Scale Inhibitor
 +
| Trisodium phosphate
 +
| 7601-54-9
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00075300
 +
| style="text-align: right;" |
 +
|-
 +
| Ethylene glycol
 +
| 107-21-1
 +
| style="text-align: right;" | 5.00
 +
| style="text-align: right;" | 0.00075300
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Sand
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Proppant
 +
| Quartz
 +
| 14808-60-7
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 11.82
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| J218 Breaker
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Breaker
 +
| Peroxydisulfuric acid, diammonium salt
 +
| 7727-54-0
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00097700
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="2"| BioRid 20L
 +
| rowspan="2"| Tetra
 +
| rowspan="2"| Biocide
 +
| 2,2-Dibromo-3-nitrilopropionamide
 +
| 10222-01-2
 +
| style="text-align: right;" | 20.00
 +
| style="text-align: right;" | 0.00280600
 +
| style="text-align: right;" |
 +
|-
 +
| Sodium bromide
 +
| 7647-15-6
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.00210500
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Gelling Agent J580
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Gelling Agent
 +
| Carbohydrate polymer
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 0.00936700
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| Water
 +
| rowspan="1"|
 +
| rowspan="1"|
 +
|
 +
|
 +
| style="text-align: right;" | 100.00
 +
| style="text-align: right;" | 87.77
 +
| style="text-align: right;" |
 +
|-
 +
|- valign="top"
 +
| rowspan="1"| 15 HCl
 +
| rowspan="1"| Schlumberger
 +
| rowspan="1"| Acid
 +
| Hydrochloric Acid
 +
|
 +
| style="text-align: right;" | 15.00
 +
| style="text-align: right;" | 0.07
 +
| style="text-align: right;" |
 +
|-
 +
|}
 +
For data sources see<ref>{{cite web
 +
| title =FracFocus Fracking Chemicals Database
 +
| date = 2019-04-02
 +
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 +
| accessdate = 2019-06-19 }}</ref>
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 165: Line 332:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 188.00 Bbl
 
| style="text-align: right;" | 188.00 Bbl
Line 171: Line 338:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2013-2
+
| 2013-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 249.80 Bbl
 
| style="text-align: right;" | 249.80 Bbl
Line 177: Line 344:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2014-1
+
| 2014-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 265.50 Bbl
 
| style="text-align: right;" | 265.50 Bbl
Line 183: Line 350:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2015-1
+
| 2015-S01
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 80.00 Bbl
 
| style="text-align: right;" | 80.00 Bbl
Line 189: Line 356:
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Fracing Fluid Waste (in Barrels)
 
| Fracing Fluid Waste (in Barrels)
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 195: Line 362:
 
|  
 
|  
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 0.30 Bbl
 
| style="text-align: right;" | 0.30 Bbl
Line 201: Line 368:
 
| WVD988782532
 
| WVD988782532
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 14.23 Bbl
 
| style="text-align: right;" | 14.23 Bbl
Line 207: Line 374:
 
| 7-3115-00193
 
| 7-3115-00193
 
|-
 
|-
| 2015-2
+
| 2015-S02
 
| Produced Fluid (in Barrels)
 
| Produced Fluid (in Barrels)
 
| style="text-align: right;" | 100.50 Bbl
 
| style="text-align: right;" | 100.50 Bbl
Line 213: Line 380:
 
|  
 
|  
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 9.16 Bbl
 
| style="text-align: right;" | 9.16 Bbl
Line 219: Line 386:
 
| 7-3115-00193
 
| 7-3115-00193
 
|-
 
|-
| 2016-1
+
| 2016-S01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 152.50 Bbl
 
| style="text-align: right;" | 152.50 Bbl
Line 225: Line 392:
 
|  
 
|  
 
|-
 
|-
| 2016-2
+
| 2016-S02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 475.00 Bbl
 
| style="text-align: right;" | 475.00 Bbl
Line 231: Line 398:
 
|  
 
|  
 
|-
 
|-
| 2017-02
+
| 2017-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 24.99 Bbl
 
| style="text-align: right;" | 24.99 Bbl
Line 237: Line 404:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 5.29 Bbl
 
| style="text-align: right;" | 5.29 Bbl
Line 243: Line 410:
 
| 7-3115-00193
 
| 7-3115-00193
 
|-
 
|-
| 2017-03
+
| 2017-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 75.00 Bbl
 
| style="text-align: right;" | 75.00 Bbl
Line 249: Line 416:
 
|  
 
|  
 
|-
 
|-
| 2017-04
+
| 2017-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 125.25 Bbl
 
| style="text-align: right;" | 125.25 Bbl
Line 255: Line 422:
 
|  
 
|  
 
|-
 
|-
| 2017-05
+
| 2017-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 27.50 Bbl
 
| style="text-align: right;" | 27.50 Bbl
Line 261: Line 428:
 
| WMGR123NC022
 
| WMGR123NC022
 
|-
 
|-
| 2017-06
+
| 2017-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 125.00 Bbl
 
| style="text-align: right;" | 125.00 Bbl
Line 267: Line 434:
 
|  
 
|  
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 20.00 Bbl
 
| style="text-align: right;" | 20.00 Bbl
Line 273: Line 440:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 279: Line 446:
 
|  
 
|  
 
|-
 
|-
| 2017-10
+
| 2017-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 51.45 Bbl
 
| style="text-align: right;" | 51.45 Bbl
Line 285: Line 452:
 
|  
 
|  
 
|-
 
|-
| 2018-01
+
| 2018-M01
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 40.00 Bbl
 
| style="text-align: right;" | 40.00 Bbl
Line 291: Line 458:
 
|  
 
|  
 
|-
 
|-
| 2018-03
+
| 2018-M03
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 297: Line 464:
 
|  
 
|  
 
|-
 
|-
| 2018-04
+
| 2018-M04
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 114.45 Bbl
 
| style="text-align: right;" | 114.45 Bbl
Line 303: Line 470:
 
|  
 
|  
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 28.04 Bbl
 
| style="text-align: right;" | 28.04 Bbl
Line 309: Line 476:
 
| WMGR123
 
| WMGR123
 
|-
 
|-
| 2018-05
+
| 2018-M05
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 52.70 Bbl
 
| style="text-align: right;" | 52.70 Bbl
Line 315: Line 482:
 
| WMGR123NC010
 
| WMGR123NC010
 
|-
 
|-
| 2018-06
+
| 2018-M06
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 150.00 Bbl
 
| style="text-align: right;" | 150.00 Bbl
Line 321: Line 488:
 
|  
 
|  
 
|-
 
|-
| 2018-07
+
| 2018-M07
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 327: Line 494:
 
|  
 
|  
 
|-
 
|-
| 2018-08
+
| 2018-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 15.15 Bbl
 
| style="text-align: right;" | 15.15 Bbl
Line 333: Line 500:
 
|  
 
|  
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 50.00 Bbl
 
| style="text-align: right;" | 50.00 Bbl
Line 339: Line 506:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-09
+
| 2018-M09
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 146.25 Bbl
 
| style="text-align: right;" | 146.25 Bbl
Line 345: Line 512:
 
|  
 
|  
 
|-
 
|-
| 2018-10
+
| 2018-M10
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 60.00 Bbl
 
| style="text-align: right;" | 60.00 Bbl
Line 351: Line 518:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 357: Line 524:
 
| WMGR123NW011
 
| WMGR123NW011
 
|-
 
|-
| 2018-12
+
| 2018-M12
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 25.00 Bbl
 
| style="text-align: right;" | 25.00 Bbl
Line 363: Line 530:
 
|  
 
|  
 
|-
 
|-
| 2019-02
+
| 2019-M02
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 45.00 Bbl
 
| style="text-align: right;" | 45.00 Bbl
Line 388: Line 555:
 
| 1916292
 
| 1916292
 
| Primary Facility
 
| Primary Facility
| 09/29/2010
+
| 2010-09-29
 
| Drilling/Alteration
 
| Drilling/Alteration
 
| No Violations Noted
 
| No Violations Noted
Line 395: Line 562:
 
| 1965575
 
| 1965575
 
| Primary Facility
 
| Primary Facility
| 04/12/2011
+
| 2011-04-12
 
| Follow-up Inspection
 
| Follow-up Inspection
 
| Violation(s) Noted
 
| Violation(s) Noted
Line 402: Line 569:
 
| 2039718
 
| 2039718
 
| Primary Facility
 
| Primary Facility
| 01/31/2012
+
| 2012-01-31
 
| Compliance Evaluation
 
| Compliance Evaluation
 
| No Violations Noted
 
| No Violations Noted
Line 409: Line 576:
 
| 2054149
 
| 2054149
 
| Primary Facility
 
| Primary Facility
| 03/21/2012
+
| 2012-03-21
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 416: Line 583:
 
| 2081848
 
| 2081848
 
| Primary Facility
 
| Primary Facility
| 07/09/2012
+
| 2012-07-09
 
| Routine/Complete Inspection
 
| Routine/Complete Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 423: Line 590:
 
| 2210699
 
| 2210699
 
| Primary Facility
 
| Primary Facility
| 10/07/2013
+
| 2013-10-07
 
| Routine/Partial Inspection
 
| Routine/Partial Inspection
 
| No Violations Noted
 
| No Violations Noted
Line 471: Line 638:
 
| 608858
 
| 608858
 
| 04/12/2011
 
| 04/12/2011
| 01/31/2012
+
| 2011-04-12
 
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste.
 
| SWMA301 - Failure to properly store, transport, process or dispose of a residual waste.
 
| Environmental Health & Safety
 
| Environmental Health & Safety
Line 479: Line 646:
 
| 608859
 
| 608859
 
| 04/12/2011
 
| 04/12/2011
| 01/31/2012
+
| 2011-04-12
 
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution.
 
| 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution.
 
| Environmental Health & Safety
 
| Environmental Health & Safety
Line 487: Line 654:
 
| 608860
 
| 608860
 
| 04/12/2011
 
| 04/12/2011
| 01/31/2012
+
| 2011-04-12
 
| 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances.
 
| 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances.
 
| Administrative
 
| Administrative
Line 511: Line 678:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
| 1
 
| 04/17/2011
 
| 04/17/2011
 
| style="text-align: right;" | 6217.00
 
| style="text-align: right;" | 5,116,923.0
 
| style="text-align: right;" |
 
|-
 
|}
 
==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|- valign="top"
 
| rowspan="15"| 1
 
| rowspan="4"| A264 Corrosion Inhibitor
 
| rowspan="4"| Schlumberger
 
| rowspan="4"| Corrosion Inhibitor
 
| Methanol
 
| 67-56-1
 
| style="text-align: right;" | 40.00
 
| style="text-align: right;" | 0.00016000
 
| style="text-align: right;" |
 
|-
 
| Aliphatic acids
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00012000
 
| style="text-align: right;" |
 
|-
 
| Aliphatic alcohols, ethoxylated #1
 
|
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.00012000
 
| style="text-align: right;" |
 
|-
 
| Propargyl alcohol
 
| 107-19-7
 
| style="text-align: right;" | 10.00
 
| style="text-align: right;" | 0.00004000
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| L058
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Iron Control
 
| Sodium erythorbate
 
| 6381-77-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00025800
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| J609
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Friction Reducer
 
| Ammonium sulfate
 
| 7783-20-2
 
| style="text-align: right;" | 30.00
 
| style="text-align: right;" | 0.03
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| Scale Inhibitor B317
 
| rowspan="2"| Schlumberger
 
| rowspan="2"| Scale Inhibitor
 
| Trisodium phosphate
 
| 7601-54-9
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00075300
 
| style="text-align: right;" |
 
|-
 
| Ethylene glycol
 
| 107-21-1
 
| style="text-align: right;" | 5.00
 
| style="text-align: right;" | 0.00075300
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Sand
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Proppant
 
| Quartz
 
| 14808-60-7
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 11.82
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| J218 Breaker
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Breaker
 
| Peroxydisulfuric acid, diammonium salt
 
| 7727-54-0
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00097700
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="2"| BioRid 20L
 
| rowspan="2"| Tetra
 
| rowspan="2"| Biocide
 
| 2,2-Dibromo-3-nitrilopropionamide
 
| 10222-01-2
 
| style="text-align: right;" | 20.00
 
| style="text-align: right;" | 0.00280600
 
| style="text-align: right;" |
 
|-
 
| Sodium bromide
 
| 7647-15-6
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.00210500
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Gelling Agent J580
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Gelling Agent
 
| Carbohydrate polymer
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 0.00936700
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| Water
 
| rowspan="1"|
 
| rowspan="1"|
 
|
 
|
 
| style="text-align: right;" | 100.00
 
| style="text-align: right;" | 87.77
 
| style="text-align: right;" |
 
|-
 
|- valign="top"
 
| rowspan="1"| 15 HCl
 
| rowspan="1"| Schlumberger
 
| rowspan="1"| Acid
 
| Hydrochloric Acid
 
|
 
| style="text-align: right;" | 15.00
 
| style="text-align: right;" | 0.07
 
| style="text-align: right;" |
 
|-
 
|}
 
For data sources see<ref>{{cite web
 
| title =FracFocus Fracking Chemicals Database
 
| date = 2019-04-02
 
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
| accessdate = 2019-06-19 }}</ref>
 
 
==References==
 
==References==
 
<references/>
 
<references/>

Revision as of 13:06, 2 August 2019

Well Details

Well ID: 37-117-20621
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Gaines Township
Operator Name: TILDEN MARCELLUS LLC
Well Pad ID: 149057
Farm/Lease Name: PIERSON 810 6H
License Status: Active
Spud Date: 2010-09-28
Permit Date: 2010-03-23
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.689756
Longitude: -77.560883

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-04-17 2011-04-17 6217.00 5,116,923.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 A264 Corrosion Inhibitor Schlumberger Corrosion Inhibitor Methanol 67-56-1 40.00 0.00016000
Aliphatic acids 30.00 0.00012000
Aliphatic alcohols, ethoxylated #1 30.00 0.00012000
Propargyl alcohol 107-19-7 10.00 0.00004000
L058 Schlumberger Iron Control Sodium erythorbate 6381-77-7 100.00 0.00025800
J609 Schlumberger Friction Reducer Ammonium sulfate 7783-20-2 30.00 0.03
Scale Inhibitor B317 Schlumberger Scale Inhibitor Trisodium phosphate 7601-54-9 5.00 0.00075300
Ethylene glycol 107-21-1 5.00 0.00075300
Sand Schlumberger Proppant Quartz 14808-60-7 100.00 11.82
J218 Breaker Schlumberger Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00097700
BioRid 20L Tetra Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00280600
Sodium bromide 7647-15-6 15.00 0.00210500
Gelling Agent J580 Schlumberger Gelling Agent Carbohydrate polymer 100.00 0.00936700
Water 100.00 87.77
15 HCl Schlumberger Acid Hydrochloric Acid 15.00 0.07

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ULTRA RESOURCES INC 0.00 0 0.00 0 0.00 0
2011 ULTRA RESOURCES INC 286,951.00 253 0.00 0 0.00 0
2012 ULTRA RESOURCES INC 272,753.00 366 0.00 0 0.00 0
2013 ULTRA RESOURCES INC 221,629.00 355 0.00 0 0.00 0
2014 ULTRA RESOURCES INC 192,657.25 319 0.00 0 0.00 0
2015 SWEPI LP 53,271.64 58 0.00 0 0.00 0
2016 SWEPI LP 233,406.14 296 0.00 0 0.00 0
2017 SWEPI LP 164,285.79 336 0.00 0 0.00 0
2018 SWEPI LP 146,908.19 337 0.00 0 0.00 0
2019 SWEPI LP 39,057.52 86 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-S02 Produced Fluid (in Barrels) 188.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-S02 Produced Fluid (in Barrels) 249.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014-S01 Produced Fluid (in Barrels) 265.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-S01 Produced Fluid (in Barrels) 80.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Fracing Fluid Waste (in Barrels) 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 0.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WVD988782532
2015-S02 Produced Fluid (in Barrels) 14.23 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2015-S02 Produced Fluid (in Barrels) 100.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S01 Produced Fluid (in Barrels) RWC 802 9.16 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2016-S01 Produced Fluid (in Barrels) RWC 802 152.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-S02 Produced Fluid (in Barrels) RWC 802 475.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017-M02 Produced Fluid (in Barrels) RWC 802 24.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M03 Other Oil & Gas Wastes (in Barrels) RWC 899 5.29 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2017-M03 Produced Fluid (in Barrels) RWC 802 75.00 Bbl REUSE (AT WELL PAD)
2017-M04 Produced Fluid (in Barrels) RWC 802 125.25 Bbl REUSE (AT WELL PAD)
2017-M05 Produced Fluid (in Barrels) RWC 802 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-M06 Produced Fluid (in Barrels) RWC 802 125.00 Bbl REUSE (AT WELL PAD)
2017-M07 Produced Fluid (in Barrels) RWC 802 20.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2017-M10 Produced Fluid (in Barrels) RWC 802 51.45 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 114.45 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 28.04 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-M05 Produced Fluid (in Barrels) RWC 802 52.70 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 150.00 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 15.15 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M09 Produced Fluid (in Barrels) RWC 802 146.25 Bbl REUSE (AT WELL PAD)
2018-M10 Produced Fluid (in Barrels) RWC 802 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M12 Produced Fluid (in Barrels) RWC 802 25.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-M12 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 45.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1916292 Primary Facility 2010-09-29 Drilling/Alteration No Violations Noted
1965575 Primary Facility 2011-04-12 Follow-up Inspection Violation(s) Noted High sp con on pad surface puddles.
2039718 Primary Facility 2012-01-31 Compliance Evaluation No Violations Noted
2054149 Primary Facility 2012-03-21 Routine/Partial Inspection No Violations Noted A routine inspection was conducted at the Pierson 810 pad on Mar. 21, 2012. Seven wells are drilled (1H, 2H, 3H, 4H, 5H, 6H, and 8H) and one additional well is permitted (7H). The Fox pad has not yet been constructed. The erosion control BMPs were inspected and wer found to be functioning and maintained. Several puddles around the pad were monitored with a conductivity probe. No elevated readings for specific conductivity were found outside containment. A reading of 3,200 µS was taken from inside the secondary containment for the production tanks. This material should be recovered and disposed of properly. Both cut and fill slopes were showing signs of sporadic vegetative growth. These areas need to be assessed to determine if re-seeding is warranted. No violations were cited during this inspection. - MRN
2081848 Primary Facility 2012-07-09 Routine/Complete Inspection No Violations Noted
2210699 Primary Facility 2013-10-07 Routine/Partial Inspection No Violations Noted On October 7, 2013 an inspection was conducted at the Pierson 810 pad in Gaines Township, Tioga County. The last inspection conducted on behalf of the operator was on 10/4/13. During this inspection the following was noted: The silt sock installed at this has degraded over time and is in need of maintenance or replacement prior to any additional earth disturbance activities. Several area of the site are in need of additional stabilization. No evidence of sediment transport off-site was observed during this inspection. Several puddles were screened and no exhibited elevated conductance. No violations were cited during this inspection.
2468108 Primary Facility 2016-03-17 Routine/Complete Inspection No Violations Noted The Department of Environmental Protection (DEP) inspected the SWEPI LP – Pierson 810 site on 3/17/2016 @ 1300 hours. The weather was 54°, partly sunny 41% humidity. An adequate site ID sign was observed at the entrance of the access road. A copy of the well permits was posted on the back of the sign. The site was last inspected by company personnel on 3/9/2016 with “no visible issues” noted in the comments section. The Pierson 810 pad is located ~6500’ past the Thomas 808 pad, along the same access road. The access road appears stable. A compressor station is located on the pad. Eight well heads were visible on the pad surface during the inspection; four appear to be in production. The cut slope of the pad appears well stabilized and well vegetated. The cut slope appears rocky with vegetation in some areas. Silt sock was observed below the fill slope. No fluid was observed in the secondary containment surrounding the produced fluid tanks. No violations are noted at this time. I departed the site @ 1345 h
2624236 Primary Facility 2017-08-09 Site Restoration No Violations Noted On 8/9/17 at 1240 hrs I conducted an inspection of the Pierson 810 well site. Dan Oakes, SWEPI Production Operator, arrived during the inspection. It was mostly sunny and 78 degrees F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The site consists of the access road and well pad. Eight wells, the Pierson 810 1H - 8H, (Photos #1 & 2), have been drilled. According to DEP records, the 1H, 3H, 5H and 6H wells are in production. The 2H, 4H, 7H and 8H wells were placed on inactive status on 3/14/12.

Produced water is stored production tanks, which are staged in secondary containment (Photo #3). Routine secondary containment inspections are being completed; the last inspection was on 8/9/17. Water in the containment structure had a field measured specific conductance reading of 763 micro Siemens/cm.

The well site has been restored and post-construction stormwater management (PCSM) BMPs ha

2721549 Primary Facility 2018-04-23 Routine/Complete Inspection No Violations Noted The site consists of the access road and well pad. Eight wells, the Pierson 810 1H - 8H have been drilled. According to DEP records, the 1H, 3H, 5H and 6H wells are in production. The 2H, 4H, 7H and 8H wells were placed on inactive status on 3/14/12. No erosion issues were noted during this inspection. The site appears to be permanently stabilized. The overall pad size has been reduced and post construction Stormwater management BMPs have been installed. The access road to the Fox 813 well pad has been restored it is stabilized No violations were cited during this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1965575 608858 04/12/2011 2011-04-12 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
1965575 608859 04/12/2011 2011-04-12 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
1965575 608860 04/12/2011 2011-04-12 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative