If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: | + | | License Date: 1982-12-21 |
|- | |- | ||
| Spud Date: 1983-01-08 | | Spud Date: 1983-01-08 |
Well ID: 34-119-26168 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.901794722,"lon":-82.0719332,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Muskingum | |
Municipality: Springfield Township | |
Operator Name: STONEBRIDGE OPERATING CO LLC | |
Well Pad ID: | |
Farm/Lease Name: FRANCE MARY & CARL | |
License Status: Producing | |
License Date: 1982-12-21 | |
Spud Date: 1983-01-08 | |
Spud Drilling Contractor: BEVERLY DRLG | |
Final Drill Date: 1983-01-12 | |
Well Total Depth: 3547 ft | |
Configuration: Vertical | |
Latitude: 39.901794722 | |
Longitude: -82.07193320 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-12-21 | 631 BT ENERGY CORP GeoDate 12/21/82 |
Oil and Gas | 1982-12-21 | Issued Date 12/21/82 Expired Date 6/19/83 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03547 Proposed Drill Depth 03547 |
Original Spud | 1983-01-08 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Completed | 1983-01-12 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Reached Total Depth | 1983-01-12 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Completion Report Received | 1983-02-17 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Construction Permit Expires | 1983-06-19 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Change of Owner | 2007-10-12 | Operator changed from 631, BT ENERGY CORP to 2070, STONEBRIDGE OPERATING CO |
Last Compliance Report | 2017-10-02 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
Record Last Modified | 2017-10-02 | R.I. R.L. 12-25-82 R.I. R. I. 12/25/1982 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3423 | 3431 | 0 |
2006-09-11 | 3424 | 3430 | 7 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 800 Bbl | 60000 | FRAC: 800 BBL H2O, 60M SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL8603 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0046964345 | 2010-08-25 | Production Wells | No Violations | Well is still in violation. A new sign has been put up near the well. A 31 day chart has been put on the meter (7/23/2010) but the clock has stopped and the flowline is still parted so there can be no sales. |
0076502367 | 2009-05-13 | Production Wells | No Violations | |
0209825803 | 2017-08-31 | Production Wells | No Violations
[1]100 barrel steel tank and a vertical separator with a domestic hook- | |
0240983513 | 2014-02-14 | Production Wells | No Violations | On the day of my inspection I witnessed that the tank battery consisted of a 100bbl tank, vertical separator and domestic gas meter. Valves were closed on the flow line going into the separator and on the domestic gas service. The well was equipped with 4.5 inch casing, 2.375 inch tubing, rods and a gasoline powered pumping unit valves were open at the well head. Identification was present at the well and on the tank. Tank identification was faded but legible. Production records were up to date. |
0304761994 | 2005-09-20 | Production Wells | No Violations | Chiefs order. Unit leveled, prime mover installed. Tanks painted. Line from Separator to tank replaced. Well selling ~6 thru a 1/8 plate. |
0333251494 | 2004-10-19 | Production Wells | No Violations | |
0362666057 | 2011-04-19 | Production Wells | No Violations | Still feeding gas, chart just changed. |
0461083628 | 2007-03-14 | Production Wells | No Violations | FOLLOW UP TO NOV # -1805174785 Well is not producing. Zero on meter has been adjusted to show production. No gas is being sold and the unit is not running. No royalties paid. No sales |
0480549035 | 2004-09-23 | Annular Disposal | No Violations | AD not in use. |
0496223371 | 2004-07-08 | Production Wells | Violations Noted | Unit ascew, not able to pump. Chart not changed for years. Flowline leaking around repair clamp |
0498328640 | 2012-05-15 | Production Wells | No Violations | Well is producing. Id is in place and makes gas. NOV is resolved. |
0551577970 | 2010-11-10 | Production Wells | No Violations | Well is still shut in with a parted flow line. |
0624741996 | 2009-02-18 | Production Wells | No Violations | Well is still idle. Flowline has been severed apparently when electric and phone line were run to new housing development. Well cannot produce until this is repaired. Pictures. NOV has been ignored. Will request Chiefs Order again. |
0634880801 | 2007-06-28 | Production Wells | No Violations | no sales. No place for gas to go. Landowners have not received any royalties. Valve where ties in to Sidwell is closed. That line is only used for house gas so there would be no sales anyway. Pics |
0728980154 | 2010-03-15 | Production Wells | No Violations | Flowline still parted near well. Still in violation. |
0841227434 | 2010-02-04 | Production Wells | No Violations | Well is still shut in. Agreement pending with operator. |
0912666947 | 2006-12-20 | Production Wells | No Violations | Producing |
1028271122 | 2017-08-31 | Temporary Abandoned Annular Disposal | No Violations | On the day of my inspection the annular disposal is not hooked up. |
1120842714 | 2005-07-05 | Production Wells | No Violations | Still shut in. Written NOV issued 6/21/05. |
1123695787 | 2005-08-10 | Production Wells | No Violations | No Action on produce or plug NOV sent 6/22/2005. Complaintant called again. |
1141155209 | 2010-09-08 | Production Wells | No Violations | Flowline still parted. Well still incapable of production. |
1170010288 | 2011-03-01 | Production Wells | No Violations | Well has been worked over recently. Gas moving thru separator and meter. NOV Satisfied. |
1173887759 | 2005-02-08 | Production Wells | Violations Noted | |
1204304982 | 2008-02-29 | Production Wells | Violations Noted | All findings of 3/14/2007 still apply. No gas sales. Unit has not been run. Flowline still shut in. No domestic gas use. No royalties paid. Request Chiefs Order. Pictures. Produce or plug |
1258402900 | 2009-11-09 | Production Wells | No Violations | Still shut in |
1293577258 | 2010-07-07 | Production Wells | No Violations | The well is still shut in. Flowline is still parted. No sales. The well is still in violation. |
1346060062 | 2012-08-09 | Production Wells | No Violations | Company and I met on well. The well was equipped with artificial lift system was cycling gas on day of inspection. Well was making 3.7 MCF on flow meter on day of inspection with Keith Kreagor. The inspection was due to getting letter from Graham and Graham Law Firm. No violations noted. |
1698357865 | 2005-01-26 | Production Wells | No Violations | |
1744656533 | 2005-09-22 | Production Wells | No Violations | Met pumper there and looked of=ver everything. Well is back on line and in compliance with Chiefs order. |
1805174785 | 2007-03-14 | Production Wells | Violations Noted | Well is not producing. Zero on meter has been adjusted to show production. No gas is being sold and the unit is not running. No royalties paid. No sales |
1926819786 | 2007-02-28 | Production Wells | No Violations | producing? Looks like zero has been tweaked to show that the well is producing. |
2074218724 | 2017-08-31 | Temporary Abandoned Annular Disposal | No Violations | On the day of inspection, I accompanied ODNR Inspector Pat Shreve. Please refer to his comments for a detailed report. We found no indication of annular disposal connected. The well is equipped with a pumping unit, Honda engine, 4 1/2 inch diameter casing, tubing head, 2 3/8 inch diameter tubing, and the tubing annulus is open. The production equipment consists of (1) 100-barrel steel tank, (1) vertical separator, (1) methanol drip tank, (1) chart meter, and (1) domestic meter. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0496223371 | US-OH-125425 | 2004-07-08 | Well insufficiently equipped to prevent escape of oil and gas | |
0496223371 | US-OH-125426 | 2004-07-08 | Failure to legibly identify well | |
0496223371 | US-OH-125427 | 2004-07-08 | Well shall be plugged | |
1173887759 | US-OH-104590 | 2005-06-21 | Well shall be plugged | |
1204304982 | US-OH-105336 | 2008-02-29 | Well shall be plugged | |
1805174785 | US-OH-118027 | 2007-03-22 | Well shall be plugged |
For data sources see[9]