X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-085-20224"

m
m
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2003-06-11
+
| License Date: 1977-03-02
 
|-
 
|-
 
| Spud Date: 1977-03-03
 
| Spud Date: 1977-03-03

Revision as of 13:26, 25 July 2019

Well Details

Well ID: 34-085-20224
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Mentor
Operator Name: ROCKEFELLER OIL COMPANY LLC
Well Pad ID:
Farm/Lease Name: OSBORNE INC
License Status: Producing
License Date: 1977-03-02
Spud Date: 1977-03-03
Spud Drilling Contractor:
Final Drill Date: 1978-01-19
Well Total Depth: 3100 ft
Configuration: Vertical
Latitude: 41.664963862
Longitude: -81.36842538

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-03-02 425 OSBORNE MICHAEL E GeoDate 3/2/77
Original Spud 1977-03-03 GL=640.5, DF=645.5, KB=646.5
Completed 1978-01-19 GL=640.5, DF=645.5, KB=646.5
Reached Total Depth 1978-01-19 GL=640.5, DF=645.5, KB=646.5
Change of Owner 2007-04-03 Operator changed from 425, MENTOR ENERGY & RESOURCES to 7447, GREAT PLAINS EXPLORATION LLC
Change of Owner 2016-12-05 Operator changed from 7447, GREAT PLAINS EXPLORATION LLC to 9828, ROCKEFELLER OIL COMPANY LLC
Record Last Modified 2016-12-05 GL=640.5, DF=645.5, KB=646.5

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3007 3051 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1675 Bbl 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 MENTOR ENERGY & RESOURCES 10942 102 365
2007 GREAT PLAINS EXPLORATION LLC 6425 0 365
2008 GREAT PLAINS EXPLORATION LLC 3893 30 365
2009 GREAT PLAINS EXPLORATION LLC 5101 47 365
2010 GREAT PLAINS EXPLORATION LLC 4507 0 365
2011 GREAT PLAINS EXPLORATION LLC 5332 16 365
2012 GREAT PLAINS EXPLORATION LLC 3074 12 366
2013 MENTOR ENERGY & RESOURCES 5087 13 365
2014 MENTOR ENERGY & RESOURCES 4929 35 365
2015 MENTOR ENERGY & RESOURCES 2513 0 365
2016 GREAT PLAINS EXPLORATION LLC 465 0 304

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 MENTOR ENERGY & RESOURCES Brine 60 365
2007 GREAT PLAINS EXPLORATION LLC Brine 120 365
2008 GREAT PLAINS EXPLORATION LLC Brine 80 365
2009 GREAT PLAINS EXPLORATION LLC Brine 160 365
2010 GREAT PLAINS EXPLORATION LLC Brine 80 365
2011 GREAT PLAINS EXPLORATION LLC Brine 240 365
2012 GREAT PLAINS EXPLORATION LLC Brine 200 366
2013 MENTOR ENERGY & RESOURCES Brine 80 365
2014 MENTOR ENERGY & RESOURCES Brine 80 365
2015 MENTOR ENERGY & RESOURCES Brine 0 365
2016 GREAT PLAINS EXPLORATION LLC Brine 0 304

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0436324892 2017-04-06 UrbanProduction Wells No Violations I inspected this well location as a follow-up to a previously-issued Compliance Notice. At the time of this inspection, I found the following: Fittings and connections at the wellhead were secure and free from leakage. The tank battery was comprised of a 210-barrel steel production tank with separator unit located on a narrow grassy, landscaped area, surrounded by surface roadways and parking for a commercial and light industrial office park development. Load-lines had been secured with locks. The company has made no attempt to establish secondary containment around the existing tank battery. There is a storm drain inlet located 40 feet down-gradient from the 210-barrel production tank. The owner has indicated that the deficiencies will be fixed but will not provide a timetable.
0506694726 2014-12-04 UrbanProduction Wells No Violations The secondary containment at the battery remains missing at the time of this inspection. Tim Reilly representing Great Plains Exploration reports that this issue is being worked on.
0794320165 2015-03-03 UrbanProduction Wells No Violations I inspected this well as a routine inspection and follow-up to a previously-issued Compliance Notice for violation of 1501:9-9-05(A)(9) which stipulates the requirement to have secondary containment at tank battery storage . Fittings and connections at the wellhead and battery are secure. At the time of this inspection, the well owner has not addressed the existing secondary containment deficiency.
0838151555 2016-02-17 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of my inspection I observed the following elements: a wellhead with mechanical plunger lift system, mechanical separator, and tank battery comprised of one 210-barrel, steel storage tank. The well was located within the gated FedEx facility but otherwise, the individual elements were not enclosed. Fittings and connections at the wellhead and battery were secure and free from signs of leakage or problems. The tank lid was closed and secure. The load-line valve was locked.
1067001569 2003-10-24 Production Wells Violations Noted no violation in fieild Bonding violation columbus office.
1186710974 2017-12-06 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previously-issued compliance notice for the following deficiencies: the load-line valves were not locked, there was no secondary containment. At the time of this inspection, I observed the following: the load-line valves were locked. However, there remains no secondary containment. In addition, the ID signage has not been updated to reflect the change of ownership that occurred over 12 months prior to this inspection. I have contacted the company on several occasions since the issuance of the compliance notice. The company has reported that problems with personnel and/or lack of funds, have prevented them from being in compliance.
1244683760 2017-09-12 UrbanProduction Wells No Violations I inspected this well as a follow-up to a previous inspection and associated compliance notice issued for the following issues: the load-lines were no secured with locks. At the time of this inspection, the load lone valve had been locked but the tank remains lacking any type of secondary containment. In addition, the identifying signage had remained unchanged since the previous change of ownership and had not been updated to reflect new ownership. Repeated calls to the owner have not produced any demonstrable action or results.
1964190452 2003-07-24 Production Wells Violations Noted found tank battery not well ;one 210 BBL ,seperator,EOG Drip tank, meter box. Adminative violation bonding.
2068250097 2012-12-17 UrbanProduction Wells Violations Noted The unit is comprised of a one-tank battery (1 210-barrel) and a wellhead with mechanical plunger lift, and mechanical separator, which is not enclosed. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . The loadouts need locked. Unit identification is present and legible at the tank battery. There is no secondary containment at the tank battery. I did not observe any leaks, spills, or other signs of contamination. I called Tim Reilly and advised him about the need for loadout locks and a dike.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1067001569 US-OH-101366 2004-01-22 Failure to legibly identify well
1964190452 US-OH-119837 2003-08-11 Well shall be plugged
2068250097 US-OH-121084 2013-01-04 LOCKS
2068250097 US-OH-121085 2013-01-04 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References