| County: [[Lake_County,_Ohio|Lake]] | | County: [[Lake_County,_Ohio|Lake]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Perry Township,_Lake_County,_Ohio|Perry Township]] |
|- | |- | ||
| Operator Name: [[RONALD A GIBSON & ASSOC INC]] | | Operator Name: [[RONALD A GIBSON & ASSOC INC]] |
Well ID: 34-085-20914 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.762740632,"lon":-81.16039719,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Perry Township | |
Operator Name: RONALD A GIBSON & ASSOC INC | |
Well Pad ID: | |
Farm/Lease Name: CARY | |
License Status: Producing | |
License Date: 1987-07-31 | |
Spud Date: 1988-01-30 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1988-02-02 | |
Well Total Depth: 3145 ft | |
Configuration: Vertical | |
Latitude: 41.762740632 | |
Longitude: -81.16039719 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-07-31 | 198 VIKING RESOURCES CORP GeoDate 7/31/87 |
Oil and Gas | 1987-07-31 | Issued Date 7/31/87 Expired Date 7/30/88 Acres 0020000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03145 Proposed Drill Depth 03145 |
Original Spud | 1988-01-29 | |
Completed | 1988-02-02 | |
Reached Total Depth | 1988-02-02 | |
Construction Permit Expires | 1988-07-30 | |
Completion Report Received | 1991-05-20 | |
Change of Owner | 1998-10-06 | Operator changed from 198, VIKING RESOURCES CORP to 4908, GIBSON RONALD A & ASSOC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2908 | 2972 | 26 |
1997-06-29 | 2911 | 2972 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 54400 Gal | 30000 | FRAC W/54,400 GAL H20 & 30M# SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL14190 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0161547313 | 2016-11-03 | UrbanProduction Wells | No Violations | I inspected this producing well as part of routine inspection activity. At the time of this inspection, the following elements were present: pump jack system and tank battery system in separate, chain-link enclosures. Fittings and connections at the wellhead were secure from leakage or problems. The areas surrounding the wellhead were comprised of an open agricultural field within a larger commercial nursery facility. I walked the area surrounding the wellhead and did not observe any signs of impact or problems. The associated tank battery is located near the main roadway and is shared with the #-2-917 unit. The load-lines were plugged and secure. The tank lids were closed. The secondary containment was dry and free from signs of leakage, spills or other problems. The access road to the battery and well is a shared-use road with the nursery facility and was in good condition. There were no issues or problems requiring attention at the time of this inspection. I noted that there was no apparent production report filed for the 2015 reporting period. I contacted the well owner and he indicated that he would investigate to determine where the missing information was. As of 11/04/2016, the owner had electronically transmitted the Form 10 annual production data for 2015 to ODNR in Columbus. |
0326819802 | 2014-11-10 | UrbanProduction Wells | No Violations | I inspected this location has part of routine inspection activity. The well is producing and production records are current. The fittings and connections at the pump jack are free from signs of leakage or other problems. The chain-link enclosure is intact and locked. Fittings at the tank battery are free from signs of leakage or problems. The load-outs are bull-plugged and locked. Safety equipment is present. Secondary containment is intact. ID Signage is present. The lease road, shared with the nursery facility, is comprised of hard-packed dirt and is dry and stable currently. The battery is shared with the #2-917 unit. |
0342480311 | 2012-02-09 | UrbanProduction Wells | No Violations | Well is a pump jack unit, unit is fenced. Tank battery is fenced. There are two 100 BBL production tanks and a mechical separtor in the battery. Dike is in good repair. |
0700719478 | 2017-11-17 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection I found the following: wellhead with pump jack and adjacent tank battery located within the nursery facility, and access roads shared with the nursery. The fittings and connections were secure, Enclosure gates were locked. Load lines were plugged and secure. I walked and inspected the areas surrounding the well and battery and found normal greenscape with no signs of problems or impacts. I had noted during a previous inspection that one of the stock tanks was severely rusted, with several holes. I had advised Ron Gibson that the tank must not be produced into to, and must be removed. He had advised that production into the tank had stopped, and removal of the tank was pending. |
0717738538 | 2013-03-01 | UrbanProduction Wells | No Violations | The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead is comprised of a pumpjack unit, not enclosed. The tank battery is comprised of 2 210-barrel (BBL) tanks, mechanical separator, and associated piping and appurtenances, not enclosed. The tank battery system is shared with the #848 producing unit. The ID sign for this unit is in poor condition. I did not observe any leaks, releases, or problems. In contacted Ron Gibson as advised him about the need for a new sign. |
1029863516 | 2018-12-18 | UrbanProduction Wells | No Violations | I conducted an inspection on this well location. The well was equipped with a pumping unit and in production, at the time of this inspection. The well was surrounded by a fence with a locked man door. The diked tank battery was comprised of one 140 BBL tank, one 100 BBL tank and a mechanical separator. The 140 BBL tank has been emptied, cleaned out and disconnected from the other production equipment, but was still inside the diked battery. Signage was located at the well and tank battery. The tank battery was also fenced with a locked man door and shared with well 2-0917. I contacted Ron Gibson of Ronald A. Gibson & Assoc Inc. regarding the removal of the 140 BBL tank. |
1091147198 | 2010-02-03 | Production Wells | No Violations | There were no violations at the time of inspection. |
1604986296 | 2013-10-02 | UrbanProduction Wells | No Violations | The producing unit consists of a pump jack unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 2 100-barrel steel production tanks and a separator unit. The elements are enclosed in separate chain-link enclosures. There is adequate secondary containment and signage at the battery but the wellhead needs a placard. No other problems noted. The battery is shared with the #917 unit. |
2027033337 | 2017-06-08 | Production Wells | No Violations | I inspected this well as part of routine inspection activity. The well with pump-jack system and associated tank battery located within the confines of an active commercial nursery operation. The tank battery is shared with the Cary #1 (#2-0917). The fittings and connecitons at the wellhead and battery were secure. I walked the areas around the well and battery and found so indications or signs of problems. I noted that the signage had become faded and notified Ron Gibson about the need for maintenance. Production reports were current and there were no indications of deficiencies with bonding or insurance in a review of electronic file information conducted on this date. |
For data sources see[9]