Revision as of 16:17, 25 July 2019

Well Details

Well ID: 34-085-21282
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Kirtland
Operator Name: PETRO EVALUATION SERV INC
Well Pad ID:
Farm/Lease Name: KNAPP ROY & DONNA
License Status: Producing
License Date: 2008-07-07
Spud Date: 2008-09-16
Spud Drilling Contractor: GREAT PLAINS EXPLORATION LLC
Final Drill Date: 2008-09-23
Well Total Depth: 3434 ft
Configuration: Vertical
Latitude: 41.640134172
Longitude: -81.31156061

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-07-07 Proposed Formations:CLINTON, Issued Date:7/7/2008, Expired Date:7/7/2009 6:00:00 AM, Drilling unit acres:24.15, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-09-23
Construction Permit Expires 2009-07-07
Completion Report Received 2010-02-17
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2010-05-17 3282 3356 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1125 Bbl 30000 TREATMENT AND RESERVOIR PRESSURES WERE NOT REPORTED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PETRO EVALUATION SERV INC 0 0 70
2009 PETRO EVALUATION SERV INC 13180 0 365
2010 PETRO EVALUATION SERV INC 7363 95 365
2011 PETRO EVALUATION SERV INC 3996 0 365
2012 PETRO EVALUATION SERV INC 3412 0 366
2013 PETRO EVALUATION SERV INC 2310 74 365
2014 PETRO EVALUATION SERV INC 1069 0 365
2015 PETRO EVALUATION SERV INC 505 0 365
2016 PETRO EVALUATION SERV INC 674 0 365
2017 PETRO EVALUATION SERV INC 861 61 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PETRO EVALUATION SERV INC Brine 327 70
2009 PETRO EVALUATION SERV INC Brine 688 365
2010 PETRO EVALUATION SERV INC Brine 264 365
2011 PETRO EVALUATION SERV INC Brine 216 365
2012 PETRO EVALUATION SERV INC Brine 288 366
2013 PETRO EVALUATION SERV INC Brine 184 365
2014 PETRO EVALUATION SERV INC Brine 0 365
2015 PETRO EVALUATION SERV INC Brine 138 365
2016 PETRO EVALUATION SERV INC Brine 70 365
2017 PETRO EVALUATION SERV INC Brine 90 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0602791785 2017-06-16 Production Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery located in a small clearing of a larger residential parcel. Fittings at the wellhead and tank battery were secure and free from signs of leakage or problems. Tank lids were closed. Load lines were closed, plugged and secure. The was intact secondary containment which was dry and free from any significant signs of spills, leakage, or other problems. I walked the areas surrounding the well and battery and observed grassy and wooded areas with no signs of impact or degradation to the natural greenscape. The gravel-paved access road was in good condition with no erosional deficits. Production data was current and there were no indications of problems or deficiencies regarding bonding and insurance.
0799769644 2008-09-17 Drill / Deepen / Reopen No Violations making location
0810196399 2018-03-15 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with pump jack system and associated tank battery located in a small clearing of a larger residential parcel. At the time of this inspection, I observed the following: Fittings at the wellhead and tank battery were secure and free from signs of leakage or problems. Tank lids were closed. Load lines were closed, plugged and secure. The was intact secondary containment which was dry and free from any significant signs of spills, leakage, or other problems. Ingress and egress to the well and battery were in good condition.
1156620356 2009-01-20 Preliminary Restoration No Violations
1316136944 2014-08-12 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 09/23/2008. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and electric pump jack system and aboveground storage tank (AST) battery. The wellhead and battery are located in a wooded residential area of Kirtland Twp. There is a short (250 ft.) dedicated lease road that accesses both the wellhead and battery from Little Mountain Road. The access road is gravel paved and in good condition. The battery is comprised of 1 steel 100-barrel production tank, 1 100-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-out is bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. The ID placard at the battery is not readable. I notified Petro Evaluation about the ID placard deficiency.
1325201734 2014-11-03 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead pump jack and battery are located on a short, dedicated access road from Little Mountain Road. Fittings and connections at the wellhead are secure and free from signs of leakage or problems. The battery is comprised of 2 100-barrel steel tanks and a separator, with a domestic meter. Fittings and connections at the battery are free from signs of leakage or problems. The well elements are not enclosed. I observed the ID sign to be significantly faded. I contacted Steve Franks with Petro Evaluation Serv. And advised him about the need for a new sign.
1487168845 2010-04-19 Production Wells No Violations There were no violations at the time of inspection.

For data sources see[9]

References