X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "34-151-25853"

m
m
Line 21: Line 21:
 
| License Status: Producing
 
| License Status: Producing
 
|-
 
|-
| License Date: 2014-06-10
+
| License Date: 2014-01-28
 
|-
 
|-
 
| Spud Date: 2014-06-10
 
| Spud Date: 2014-06-10

Revision as of 05:52, 26 July 2019

Well Details

Well ID: 34-151-25853
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Paris Township
Operator Name: C & T ENERGY OF EAST CANTON IN
Well Pad ID:
Farm/Lease Name: HOSMER UNIT
License Status: Producing
License Date: 2014-01-28
Spud Date: 2014-06-10
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2014-06-16
Well Total Depth: 5499 ft
Configuration: Vertical
Latitude: 40.808817906
Longitude: -81.15604814

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-01-28 Proposed Formations:CLINTON, Issued Date:1/28/2014, Expired Date:1/28/2016 12:00:00 PM, Drilling unit acres:47.35, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2014-06-16
Completion Report Received 2014-09-08
Construction Permit Expires 2016-01-28
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-09-09 5283 5366 73

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2014-06-26 H2O 8 131000 Gal 65000 OTHER Nabors Completion Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 C & T ENERGY OF EAST CANTON IN 337 1099 161
2015 C & T ENERGY OF EAST CANTON IN 1974 1711 365
2016 C & T ENERGY OF EAST CANTON IN 1336 1156 365
2017 C & T ENERGY OF EAST CANTON IN 774 1046 365
2018 C & T ENERGY OF EAST CANTON IN 662 862 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 C & T ENERGY OF EAST CANTON IN Brine 3225 161
2015 C & T ENERGY OF EAST CANTON IN Brine 980 365
2016 C & T ENERGY OF EAST CANTON IN Brine 420 365
2017 C & T ENERGY OF EAST CANTON IN Brine 350 365
2018 C & T ENERGY OF EAST CANTON IN Brine 210 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1402681491 2014-06-11 Casing String Witnessed No Violations I was on location to witness the cementing of the 11.75 43# Limited Service casing installed to 598. A 14.75 hole was drilled with a PDC bit to 622. There was an issue installing the casing into the hole. At the 2nd joint of casing around 38 in the ground the casing would no longer fall into the hole. The casing was attempted to be worked into the hole but it got stuck on a ledge and would no longer move. It was decided that the casing be brought out of the hole and laid down. Advent Drilling ran back into the hole with a 14.75 trichone bit to ream the hole to bottom and eliminate the ledges present in the hole. After the bit run the casing was then installed into the hole again and was able to reach bottom. Petroset was on location to cement the casing and circulated the well before pumping cement. They pumped 400sks of Class A cement with 3% CaCl. The well circulated the entire job during cementing and a total of 9 bbls of cement were returned to surface. There are no violations at this time.
1542814947 2018-11-21 Preliminary Restoration No Violations My inspection found the pits have been filled and the land restored around the well and tank battery locations. There are no signs of active erosion at either location. The preliminary restoration is compliant with Ohio Revised Code 1509.072(A). The preliminary restoration is passed. The well is equipped with a pumpjack with a domestic gas connection. The tank battery consists of a steel production tank, a steel brine tank, a vertical separator and a meter. The well is legibly identified. No compliance issues are cited.
1851052093 2014-06-10 Drill / Deepen / Reopen No Violations I was on location to check the status of Advent drilling. The rig is currently drilling on fresh water mud at 190. The surface casing is not going to be set at the 750 on the permit, but instead will be set at 600. The Big Injun formation will have a bottom of around 450 and the offset wells and logs in the area show 600 as being 50 below the base of any freshwater. The erosion controls on location are installed properly and working properly to prevent sedimentation from entering the creek behind the well. There are no violations at this time.

For data sources see[9]