If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 11: | Line 11: | ||
| County: [[Licking_County,_Ohio|Licking]] | | County: [[Licking_County,_Ohio|Licking]] | ||
|- | |- | ||
− | | Municipality: [[St._Albans_Township,_Licking_County,_Ohio|St. | + | | Municipality: [[St._Albans_Township,_Licking_County,_Ohio|St. Albans Township]] |
|- | |- | ||
| Operator Name: [[ENERVEST OPERATING LLC]] | | Operator Name: [[ENERVEST OPERATING LLC]] |
Well ID: 34-089-25551 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.107136481,"lon":-82.62229375,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Licking | |
Municipality: St. Albans Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: HOLBROOK A | |
License Status: Producing | |
License Date: 1995-07-21 | |
Spud Date: 1995-08-14 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 1995-08-20 | |
Well Total Depth: 4264 ft | |
Configuration: Vertical | |
Latitude: 40.107136481 | |
Longitude: -82.62229375 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1995-07-21 | Issued Date 7/21/95 Expired Date 7/20/96 Acres 0040000 Tool Type RTAF Proposed Formation BE thru CPRG Proposed Depth 04264 Proposed Drill Depth 04264 |
Original Spud | 1995-08-14 | FDT=LOWER |
Completed | 1995-08-20 | FDT=LOWER |
Reached Total Depth | 1995-08-20 | FDT=LOWER |
CO | 1995-10-30 | 28 CGAS EXPLORATION,INC GeoDate 7/21/95 |
Completion Report Received | 1995-11-30 | FDT=LOWER |
Construction Permit Expires | 1996-07-20 | FDT=LOWER |
Change of Owner | 2007-04-27 | Operator changed from 28, CGAS EXPLORATION to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2015-09-24 | FDT=LOWER |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3866 | 3904 | 0 |
2006-09-11 | 2872 | 3922 | 86 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 2000 Gal | 0 | W/ADDITIVES. | ||
ACID | 0 | 300 Gal | 0 | TREATED W/2300 GAL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | CGAS EXPLORATION | 8363 | 0 | 365 |
1996 | CGAS EXPLORATION | 174866 | 146 | 365 |
1997 | CGAS EXPLORATION | 139239 | 2275 | 365 |
1998 | CGAS EXPLORATION | 103611 | 3815 | 365 |
1999 | CGAS EXPLORATION | 55300 | 1672 | 365 |
2000 | CGAS EXPLORATION | 36388 | 452 | 365 |
2001 | CGAS EXPLORATION | 26304 | 75 | 365 |
2002 | CGAS EXPLORATION | 21383 | 66 | 365 |
2003 | CGAS EXPLORATION | 19047 | 95 | 365 |
2004 | CGAS EXPLORATION | 7416 | 31 | 365 |
2005 | CGAS EXPLORATION | 3574 | 0 | 365 |
2006 | CGAS EXPLORATION | 3748 | 13 | 365 |
2007 | ENERVEST OPERATING LLC | 3470 | 23 | 365 |
2008 | ENERVEST OPERATING LLC | 2985 | 17 | 365 |
2009 | ENERVEST OPERATING LLC | 7291 | 929 | 365 |
2010 | ENERVEST OPERATING LLC | 5981 | 774 | 365 |
2011 | ENERVEST OPERATING LLC | 3250 | 472 | 0 |
2012 | ENERVEST OPERATING LLC | 4112 | 551 | 366 |
2013 | ENERVEST OPERATING LLC | 3031 | 487 | 365 |
2014 | ENERVEST OPERATING LLC | 2756 | 481 | 365 |
2015 | ENERVEST OPERATING LLC | 2182 | 508 | 365 |
2016 | ENERVEST OPERATING LLC | 2818 | 477 | 366 |
2017 | ENERVEST OPERATING LLC | 2029 | 335 | 365 |
2018 | ENERVEST OPERATING LLC | 989 | 397 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1995 | CGAS EXPLORATION | Brine | 0 | 365 |
1996 | CGAS EXPLORATION | Brine | 15 | 365 |
1997 | CGAS EXPLORATION | Brine | 26 | 365 |
1998 | CGAS EXPLORATION | Brine | 7 | 365 |
1999 | CGAS EXPLORATION | Brine | 70 | 365 |
2000 | CGAS EXPLORATION | Brine | 30 | 365 |
2001 | CGAS EXPLORATION | Brine | 92 | 365 |
2002 | CGAS EXPLORATION | Brine | 0 | 365 |
2003 | CGAS EXPLORATION | Brine | 61 | 365 |
2004 | CGAS EXPLORATION | Brine | 0 | 365 |
2005 | CGAS EXPLORATION | Brine | 0 | 365 |
2006 | CGAS EXPLORATION | Brine | 0 | 365 |
2007 | ENERVEST OPERATING LLC | Brine | 37 | 365 |
2008 | ENERVEST OPERATING LLC | Brine | 2 | 365 |
2009 | ENERVEST OPERATING LLC | Brine | 704 | 365 |
2010 | ENERVEST OPERATING LLC | Brine | 541 | 365 |
2011 | ENERVEST OPERATING LLC | Brine | 472 | |
2012 | ENERVEST OPERATING LLC | Brine | 426 | 366 |
2013 | ENERVEST OPERATING LLC | Brine | 505 | 365 |
2014 | ENERVEST OPERATING LLC | Brine | 362 | 365 |
2015 | ENERVEST OPERATING LLC | Brine | 346 | 365 |
2016 | ENERVEST OPERATING LLC | Brine | 362 | 366 |
2017 | ENERVEST OPERATING LLC | Brine | 236 | 365 |
2018 | ENERVEST OPERATING LLC | Brine | 264 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000005328 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 12/6/95 INSPECTOR LEWIS BELL DATE 12/0619/95 DATA FROM OLD VAX INFO | |
0329004367 | 2015-09-23 | Production Wells | No Violations | Inspect well in regards to complaint alleging an oil/sulfur odor in the area. The complainant, Mr. Daniel Downing, lives on the east side of Northridge Road and stated that the odor is strongest on cool stagnant nights. The well was equipped with a pumping unit and motor. Identification was posted at the well. The well was not pumping during inspection. The tank battery consisted of (1) 210 barrel tank and (2) 100 barrel tanks inside an earthen dike. This well produces into a shared tank battery with #5669. Identification was posted at the tank battery. The gas detector was used at the tank battery and did not detect any levels of LELs, H2S, or methane. It was observed that the tanks did not have charcoal filters on them. The company will be contacted regarding this inspection and charcoal filters will be recommended. No violations noted during inspection. Time of inspection: 5:14 PM. Weather: 79*F, Sunny |
0477491584 | 2010-08-30 | Production Wells | No Violations | The inspection revealed that the well was actively pumping. I talked with Mark McConnahay with Enervest who was on location to check the wells and tanks. This well shares a tank battery with the Dysart well, permit 5669. There is proper display of identification posted at the tank battery. The tank battery consists of two 210 barrel tanks and one 100 barrel tank. There is also two horizontal separators. They are all contained within an earthen dike. Mark said that both wells are pumped daily. There are no violations noted this date. |
0509360448 | 2015-10-01 | Production Wells | No Violations | Inspect tank battery regarding complaint. Inspection revealed charcoal filter has not been installed as of this date. Will check again within the next week. Time of inspection: 3:30 PM. |
0575620391 | 2013-06-25 | Production Wells | No Violations | Was on site to update GPS coordinates. |
0842948289 | 2015-10-28 | Production Wells | No Violations | Check tank battery for filters. The inspection revealed that the 210 barrel tank did not have a filter on it. A phone call was placed to Tim McConeghey. Mr. McConeghey was not sure if that tank was in use and said that might be the reason a filter was not installed on that tank. Mr. Coneghey said he would find out and let me know. Time of inspection: 9:15 AM. |
1041342902 | 2002-12-31 | Production Wells | No Violations | Inspection revealed no violations noted this date. Updated Lat / Lon this date. WEATHER CONDITIONS: Cloudy and 49 degrees. |
1335596916 | 2015-09-25 | Administrative Inspection | No Violations | Spoke with complainant Mr. Daniel Downing at 2:53 PM. Mr. Daniel Downing was informed that the company was contacted and that they volunteered to install a charcoal filter on the tank battery. A follow-up inspection will be conducted at the tank battery to see when filter is installed. |
1356031557 | 2012-10-11 | Production Wells | No Violations | I inspected this well today accompanied by Mr. Eric Daugstrup. The well was equipped with a pumping unit but was not pumping during inspection. Proper identification was posted at the well and at the tanks. The valves at the well head were in the open position. The tank battery consisted of 3 tanks inside of a dike and 2 horizontal seperators approximately 50 feet from the tanks. No violations. |
1443728046 | 2015-09-25 | Administrative Inspection | No Violations | Placed phone call at 9:24 AM to Tim McConeghey with Enervest Operating regarding complaint. Mr. McConeghey was made aware of the complaint concerning an oil/sulfur odor. Mr. McConeghey stated that he would install a charcoal filter on the tank battery. |
1450731769 | 2015-11-10 | Production Wells | No Violations | Inspect tank battery. A filter was not observed on the 210 barrel tank. The company will be contacted regarding this inspection. A voicemail message was left for Mr. Daniel Downing. Time of inspection: 1:35 PM. Weather: 45*F, Overcast |
1497892861 | 2017-06-19 | Production Wells | No Violations | Inspect tank battery to close out complaint. The 210 barrel tank had plugs installed in the top of the tank. No violations. Time of inspection: 1:00 PM. |
1865281442 | 2015-10-15 | Production Wells | No Violations | Inspect tank battery. A charcoal filter has been installed on one of the 100 barrel tanks. A filter was not observed on the 210 barrel tank. I will make a phone call and ask for one to be installed on the 210 barrel tank as well. Time of inspection: 4:35 PM. Weather: 64*F, Sunny |
For data sources see[9]