If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 9: | Line 9: | ||
| State: Ohio | | State: Ohio | ||
|- | |- | ||
− | | County: | + | | County: <County> |
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Plain Township,_Wayne_County,_Ohio|Plain Township]] |
|- | |- | ||
| Operator Name: [[MFC DRILLING INC]] | | Operator Name: [[MFC DRILLING INC]] |
Well ID: 34-169-24770 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.73142902,"lon":-82.02791837,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: Plain Township | |
Operator Name: MFC DRILLING INC | |
Well Pad ID: | |
Farm/Lease Name: SIDLE CARL | |
License Status: Producing | |
License Date: 1990-04-25 | |
Spud Date: 1990-05-15 | |
Spud Drilling Contractor: KIDD DRILLING | |
Final Drill Date: 1990-06-25 | |
Well Total Depth: 3153 ft | |
Configuration: Vertical | |
Latitude: 40.731429020 | |
Longitude: -82.02791837 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1990-04-25 | Issued Date 4/25/90 Expired Date 4/25/91 Acres 0020000 Tool Type CT Proposed Formation CLINTON Proposed Depth 03153 Proposed Drill Depth 03153 |
Original Spud | 1990-05-15 | |
Completed | 1990-06-25 | |
Reached Total Depth | 1990-06-25 | |
CO | 1990-06-29 | 73 HOOVER FRANK W PRODUCER GeoDate 4/25/90 |
Completion Report Received | 1990-08-08 | |
Construction Permit Expires | 1991-04-25 | |
Change of Owner | 2010-09-10 | Operator changed from 73, HOOVER F dba CHEROKEE DRILLING to 3059, MFC DRILLING INC |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1300 Bbl | 25000 | FRAC:WATER/SAND |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0379600312 | 2017-06-30 | Preliminary Restoration | No Violations | Inspected production well on 06/30/2017. All drilling equipment and debris have been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
0856565198 | 2015-07-15 | Production Wells | No Violations | This pumping unit well appears to have no problems nor compliance issues at this time. |
0914575716 | 2016-05-17 | Production Wells | No Violations | Inspected production well on 05/17/2016. The tank battery consists of 1-100 bbl steel tank, located within a partial earthen dike. The dike needs built-up in order to effectively serve as containment in the case of a release. Additionally, the well identification that is posted at the tank battery is mostly torn off and needs replaced. Jeff Harmon, with MFC Drilling, was notified of these issues and will address them promptly. The well is equipped with a pump jack with an electric motor. No other problems were noted at the time of the inspection. |
1091865274 | 2018-06-20 | Production Wells | No Violations | Inspected production well on 06/20/2018. The well is equipped with a pump jack with an electric motor, and 1-100 bbl steel tank. Well identification is clearly displayed at both the wellhead and the tank battery. No problems were noted at the time of the inspection. |
1172904036 | 2014-07-09 | Production Wells | No Violations | Pumping unit well that appears to have no problems at this time. |
1309357476 | 2016-10-13 | Preliminary Restoration | No Violations | Inspected production well on 10/13/2016. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1932846787 | 2017-06-30 | Production Wells | No Violations | Inspected production well on 06/30/2017. The well is equipped with a pump jack with an electric motor, and 1-100 bbl steel tank. Well identification is clearly displayed at both the tank and the wellhead. No problems were noted at the time of the inspection. |
1947811087 | 2016-10-13 | Production Wells | No Violations | Inspected production well on 10/13/2016. The tank battery consists of 1-100 bbl steel tank-no earthen dike is present. Jeff Harmon, with MFC, was notified of this issue and will address it with management promptly. The well is equipped with a pump jack with an electric motor. Well identification has been posted at both the tank battery and the wellhead, as requested after the previous inspection. No other problems were noted at the time of the inspection. |
1974552511 | 2013-07-17 | Production Wells | No Violations | This pumping unit well has no apparent problems at time of inspection. |
For data sources see[8]