| County: [[Trumbull_County,_Ohio|Trumbull]] | | County: [[Trumbull_County,_Ohio|Trumbull]] | ||
|- | |- | ||
− | | Municipality: [[ | + | | Municipality: [[Newton Township,_Trumbull_County,_Ohio|Newton Township]] |
|- | |- | ||
| Operator Name: [[ERIC PETROLEUM CORP]] | | Operator Name: [[ERIC PETROLEUM CORP]] |
Well ID: 34-155-22358 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.18947745,"lon":-80.91525442,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Newton Township | |
Operator Name: ERIC PETROLEUM CORP | |
Well Pad ID: | |
Farm/Lease Name: BAILEY | |
License Status: Producing | |
License Date: 1983-06-22 | |
Spud Date: 1983-07-09 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1983-07-13 | |
Well Total Depth: 4588 ft | |
Configuration: Vertical | |
Latitude: 41.189477450 | |
Longitude: -80.91525442 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1983-06-22 | Issued Date 6/22/83 Expired Date 12/19/83 Acres 0050000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04588 Proposed Drill Depth 04588 |
Original Spud | 1983-07-09 | |
Completed | 1983-07-13 | |
Reached Total Depth | 1983-07-13 | |
CO | 1983-10-17 | 1100 GM/DELPHI PACKARD ELEC. GeoDate 6/22/83 |
Completion Report Received | 1983-11-14 | |
Construction Permit Expires | 1983-12-19 | |
CO | 1996-07-11 | 4884 EASTERN STATES OIL & GAS GeoDate 6/22/83 |
Change of Owner | 2005-06-07 | Operator changed from 4884, EASTERN STATES OIL & GAS INC to 7849, NCL NATURAL RESOURCES LLC |
Change of Owner | 2017-02-21 | Operator changed from 7849, NCL NATURAL RESOURCES LLC to 5054, ERIC PETROLEUM CORP |
Record Last Modified | 2017-02-21 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4416 | 4488 | 0 |
2006-09-11 | 4422 | 4486 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 75000 Gal | 60000 | |||
ACID | 0 | 500 Gal | 0 | FRAC;75MG H2O,60M# SD,500GAL ACID |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000000936 | 2002-10-01 | Salt Water Injection Well | Violations Noted | The piles of contaminated material have not been removed as yet. Theburied vault has not been done and the MIT test has not been done. Case pends. |
0000PL3891 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1395420816 | 2014-03-21 | Production Wells | No Violations | My inspection found the well production. The well was equipped with a plunger lift unit. The tank battery consisted of a 100 barrel production tank and a heat, treated separator. The dike met containment requirements. A bull plug was installed on the load line. An identification sign was properly posted. A domestic gas line came off the sales line at the separator. All production equipment spacing was in compliance. The lease road was in stable condition with a closed gate. The well was placed into production prior to House Bill 278. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0000000936 | US-OH-130712 | 2002-10-04 | Pollution/Contamination | |
0000000936 | US-OH-130713 | 2002-10-04 | Mechanical failure/contamination |