If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: 2001- | + | | License Date: 2001-03-06 |
|- | |- | ||
| Spud Date: 2001-04-05 | | Spud Date: 2001-04-05 |
Well ID: 34-035-21719 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.46256896,"lon":-81.65848106,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Cleveland | |
Operator Name: DUCK CREEK ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: LTV STEEL UNIT | |
License Status: Producing | |
License Date: 2001-03-06 | |
Spud Date: 2001-04-05 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2001-04-08 | |
Well Total Depth: 3010 ft | |
Configuration: Vertical | |
Latitude: 41.462568960 | |
Longitude: -81.65848106 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2001-03-06 | 1902 DUCK CREEK ENERGY INC Proposed Formation CLINTON Issued Date 3/6/01 Expired Date 3/6/02 6:00:00 AM |
Original Spud | 2001-04-05 | RBDMS Rec |
Completed | 2001-04-08 | RBDMS Rec |
Reached Total Depth | 2001-04-08 | RBDMS Rec |
Completion Report Received | 2001-09-10 | RBDMS Rec |
Construction Permit Expires | 2002-03-06 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2001-10-26 | 2828 | 2892 | 32 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 60000 Gal | 0 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | DUCK CREEK ENERGY INC | 4035 | 0 | 112 |
2002 | DUCK CREEK ENERGY INC | 6603 | 36 | 365 |
2003 | DUCK CREEK ENERGY INC | 4804 | 41 | 365 |
2004 | DUCK CREEK ENERGY INC | 2899 | 0 | 365 |
2005 | DUCK CREEK ENERGY INC | 2197 | 56 | 365 |
2006 | DUCK CREEK ENERGY INC | 1908 | 0 | 365 |
2007 | DUCK CREEK ENERGY INC | 1547 | 0 | 365 |
2008 | DUCK CREEK ENERGY INC | 1254 | 0 | 365 |
2009 | DUCK CREEK ENERGY INC | 1300 | 0 | 365 |
2010 | DUCK CREEK ENERGY INC | 1128 | 0 | 365 |
2011 | DUCK CREEK ENERGY INC | 842 | 0 | 365 |
2012 | DUCK CREEK ENERGY INC | 780 | 0 | 366 |
2013 | DUCK CREEK ENERGY INC | 179 | 0 | 365 |
2014 | DUCK CREEK ENERGY INC | 431 | 0 | 365 |
2015 | DUCK CREEK ENERGY INC | 200 | 0 | 365 |
2016 | DUCK CREEK ENERGY INC | 679 | 0 | 365 |
2017 | DUCK CREEK ENERGY INC | 47 | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | 330 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2001 | DUCK CREEK ENERGY INC | Brine | 228 | 112 |
2002 | DUCK CREEK ENERGY INC | Brine | 529 | 365 |
2003 | DUCK CREEK ENERGY INC | Brine | 393 | 365 |
2004 | DUCK CREEK ENERGY INC | Brine | 73 | 365 |
2005 | DUCK CREEK ENERGY INC | Brine | 122 | 365 |
2006 | DUCK CREEK ENERGY INC | Brine | 74 | 365 |
2007 | DUCK CREEK ENERGY INC | Brine | 75 | 365 |
2008 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2009 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 0 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 20 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 80 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 747 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0269954015 | 2010-08-17 | Preliminary Restoration | No Violations | |
0816890903 | 2017-09-14 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous inspection and compliance notice in which I had noted The well is located in a largely heavy industrial area. At the time of this inspection, fittings and connnections at the well and battery were secure. The load-line valves were plugged and locked. The secondary containment was intact. The tank which I had observed with holes had been removed. I observed no other signs or problems or issues. |
1371832148 | 2013-06-21 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead in a chain-link enclosure and an above-ground storage tank (AST) battery also in a chain-link enclosure. The battery is comprised of 1 210-barrel steel AST, 1 100-barrel AST, mechanical separator. ID is missing. Secondary containment is adequate. The wellhead is fitted with a mechanical plunger lift system and is producing. The wellhead is not enclosed. I did not observe any leaks or problems. |
1416846352 | 2014-11-24 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well is located in a heavy industrial portion of Cleveland between I-77 and the Cuyahoga River. The wellhead plunger lift system is functioning and free of signs of leakage or other problems. The battery is located near the well, next to train tracks. Fittings and connections are intact and free from signs of leakage or other problems. The missing ID signage has been fixed. The secondary containment is present. The battery enclosure is locked. Production reports are current.. |
1479310995 | 2016-11-16 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: A well with pump jack system and associated tank battery. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The tank battery was enclosed in a chain-link enclosure which was locked and secure. Secondary containment was intact and free from signs of spills or leaks. I noted the following deficiency: the 210-barrel steel production tank was severely corroded with numerous perforating holes which indicates failure of the tank integrity. The well owner must remove the tank from service and replace with a competent tank. These activities must be completed by 12/16/2016. Please contact Inspector Stephen Tompkins at 330-907-4647 regarding this inspection. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1479310995 | US-OH-113691 | 2017-12-04 | 9-1-07 | Well operation causing pollution and contamination |
For data sources see[9]