If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 21: | Line 21: | ||
| License Status: Producing | | License Status: Producing | ||
|- | |- | ||
− | | License Date: | + | | License Date: 1986-11-22 |
|- | |- | ||
| Spud Date: 1987-01-01 | | Spud Date: 1987-01-01 |
Well ID: 34-099-22082 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.990121461,"lon":-80.63689534,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: EVERFLOW EASTERN PTNS L P | |
Well Pad ID: | |
Farm/Lease Name: OHLIN | |
License Status: Producing | |
License Date: 1986-11-22 | |
Spud Date: 1987-01-01 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1987-01-06 | |
Well Total Depth: 5946 ft | |
Configuration: Vertical | |
Latitude: 40.990121461 | |
Longitude: -80.63689534 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1987-01-01 | |
Completed | 1987-01-06 | |
Reached Total Depth | 1987-01-06 | |
Completion Report Received | 1987-04-24 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1998-09-21 | 5741 | 5810 | 20 |
1998-09-21 | 5898 | 5908 | 11 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 115000 Gal | 64000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
001216i609 | 2002-05-29 | Production Wells | No Violations | Obtained GPS coordinates for the wellhead only. Unable to locate the tank battery at this time. |
0102324873 | 2007-04-10 | Production Wells | No Violations | I had Dave Claus give me his opinion on the tank battery that the Boardman fire departments had complained on. Dave also found no reason for a fence to go around tank battery or increase of the dikes. There were no violations at this time. |
0710335322 | 2018-06-13 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2082. RBDMS indicated reported production was current. Well and tank battery access remained stable and drivable through a commercial parking lot. The well was located within a board on board fence enclosure that contained correct identification. The 8.625 well head was plumbed above grade and open to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. The master gate valve was closed. No leaks were observed. A stable earthen dike that was free of fluid was present around the production equipment. Mature evergreens and neighboring privacy shielded the equipment from view. Equipment on location consisted of one (1) horizontal separator The separator remained in good repair and contained correct identification. No violations were observed during this inspection. |
1327392638 | 2004-03-19 | Production Wells | No Violations | The tank battery consists of 1-25 bbl storage tank, 1-separator and a dike. |
1562915824 | 2007-03-28 | Production Wells | No Violations | This inspection was due to the Boardman Township Fire Departments request. Tank battery was GPSd. Tank battery had cedar fence around 2 sides of battery with the other 2 sides of pine trees. The battery had inside a mound of dirt 6 foot high. Talked to condo owner to the north of tank battery. She said she has heard of no complaints. ID sign posted. There were no violations at this time. |
For data sources see[9]